1. Introduction
The WeAct Power Monitor V1 is a versatile DC voltage and current meter designed for monitoring power delivery (PD) and Quick Charge (QC) protocols. It features a compact design with an OLED display, supporting input voltages up to 36V and currents up to 10A. This manual provides essential information for the safe and effective use of your Power Monitor V1.

2. Product Contents
Please check the package contents upon receipt. If any items are missing or damaged, contact customer support.
- WeAct Power Monitor V1
- XT60 connectors (for external power connections)
- Plastic protective sheets
- Small buttons (for assembly)
- USB-C cable (for power and data)

3. Safety & Warnings
Important Safety Information:
Read all instructions before use. Failure to follow these instructions may result in damage to the product or personal injury.
- Warning: Keep the device and its cord out of reach of children under 3 years old.
- Keep away from children unless supervised by an adult.
- Do not use this product for purposes other than its intended use.
- Inspect the product before each use; do not use if damaged.
- Follow installation and operation guidelines to avoid injury.
- Do not expose to water or moisture.
4. Specifications
| Feature | Specification |
|---|---|
| Product Name | Power Monitor |
| Model Number | Power Monitor V1 |
| Input Voltage Range | 5-36V |
| Max Current | 10A |
| Shunt Resistance | 5mΩ ±1% |
| Voltage Error | ±0.1% 50ppm/°C |
| Current Error (0.01A) | ±44.07% @25°C |
| Current Error (1A) | ±1.1% @25°C |
| Current Error (10A) | ±1.01% @25°C |
| PD Request | FIX + PPS PDO, 5-20V |
| QC Request | 5V/9V/12V/20V |
| UART Communication | 9600-460800bps, 3.3V TTL |
| Measurement IC | INA226 Voltage Current mAh mWh Uptime |
| Dimensions (PCB) | 36.49mm x 33.50mm |

5. Setup
5.1. Before First Use
- Remove Protective Films: Each plastic sheet is covered with two layers of protective film on both sides. Peel off all films before assembly.
- Assembly: Attach the plastic sheets to the device using the provided small buttons. This protects the PCB and components.

5.2. Connecting Power
The Power Monitor V1 can be powered and measure via its USB-C port or through the IN+/OUT+ solder pads.
- USB-C Connection: Connect a standard USB-C cable to a certified power adapter. The device will power on and display voltage and current information.
- External Power (IN+/OUT+): For higher voltage/current applications (up to 36V/10A), use the IN+ and OUT+ solder pads. Ensure correct polarity when connecting external power sources or loads. XT60 connectors are provided for convenience with these connections.

6. Operation
6.1. Display Modes
The device features an OLED display that shows real-time voltage (V), current (A), power (W), mAh, mWh, and uptime. You can navigate through different display screens and settings using the small buttons on the side of the device.
6.2. PD/QC Negotiation
When connected to a Power Delivery (PD) or Quick Charge (QC) compatible source via USB-C, the Power Monitor V1 can negotiate various voltage and current profiles. The display will show the negotiated voltage and current settings (e.g., 5V/3A, 9V/3A, 12V/3A, 15V/3A, 20V/5A for PD, or 5V/9V/12V/20V for QC).
6.3. UART Communication
The Power Monitor V1 supports UART communication for data logging and control. It operates at baud rates from 9600 to 460800bps with 3.3V TTL logic. This allows connection to a computer or microcontroller for advanced monitoring and data analysis. Software is available for displaying data on a larger screen, including graphs.
7. User Tips
- For RC enthusiasts, this monitor is excellent for tracking charging of 2S RC car batteries, providing real-time milliamp-hour and voltage readings.
- The OLED screen offers a clear and informative display.
- When using the provided plastic covers, remember to peel off the protective films from both sides for optimal clarity.
- Consider the small size of the buttons; for projects requiring frequent interaction, external buttons might be beneficial, though soldering points for these are not explicitly designed for easy external wiring.
- The device can be powered via USB-C or directly through the IN+/OUT+ terminals, offering flexibility for various applications.
8. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use harsh chemicals or abrasive materials.
- Storage: When not in use, turn off the device and store it in a dry place, away from direct sunlight and extreme temperatures.
- Inspection: Regularly inspect the device for any signs of damage, especially the connectors and solder points.
9. Troubleshooting
- Device Not Powering On: Ensure the USB-C cable is securely connected to a certified power adapter, or that external power is correctly supplied to the IN+/OUT+ terminals with correct polarity.
- No Display: Check power connection. If using external power, verify voltage is within the 5-36V range.
- Inaccurate Readings: Ensure all connections are secure and free from corrosion. For precise measurements, ensure the device is operating within its specified temperature range.
- UART Communication Issues: Verify baud rate settings match between the device and your computer/microcontroller. Check wiring for TX, RX, 5V, and G connections.
10. Warranty & Support
For technical support, warranty claims, or further inquiries, please contact the manufacturer:
- Manufacturer: Dongguan Dongcheng Weixing Electronic Studio
- Address: Room 206, Cluster 504593TB, Building 6, No.1 Dongke Road, Dongcheng Street, Dongguan City, Guangdong Province, China
- Email: WeAct_TC@163.com
- EU Authorized Representative: Apex CE Specialists GmbH, Grafenberger Allee 277, 40237 Düsseldorf, Germany
- EU Representative Email: Info@apex-ce.com
A detailed user manual in PDF format is also available for download: User manual (PDF)