PowMr Keeper Series

Contents

PowMr Keeper Series MPPT Solar Charge Controller User Manual

Model: Keeper Series (20A, 30A, 40A)

1. Introduction and Overview

Thank you for choosing the PowMr Keeper Series MPPT Solar Charge Controller. This controller utilizes an advanced Maximum Power Point Tracking (MPPT) algorithm to efficiently track the maximum power point of your photovoltaic (PV) array, ensuring optimal energy harvest from your solar panels in various environmental conditions. This significantly improves the energy utilization of your solar system.

1.1 Key Features

  • 12V/24V automatic voltage recognition.
  • Compatible with multiple battery types: GEL, SLD, FLD, and LiFePO4 lithium batteries.
  • Multiple load control modes: General mode, Light control mode, Light & Time control mode, and Reverse Light Control Mode.
  • Equipped with battery temperature compensation function.
  • Ultra-fast maximum power point tracking speed while ensuring tracking accuracy.
  • Two 5V/1A USB ports for powering mobile devices.
  • LCD screen dynamically displays operating data and working status.
  • High MPPT charging efficiency of 97%.
  • Maximum charging current up to 40A (depending on model).
  • Three-stage charging algorithm to optimize battery performance and extend battery life.
  • Maximum PV input voltage of 100V.
  • Built-in DC output port delivers up to 30A of direct current, suitable for powering DC loads.

1.2 Product Appearance

The following diagram illustrates the main components of the solar charge controller:

Front view of PowMr Keeper Series Solar Charge Controller

Figure 1: Front view of the PowMr Keeper Series Solar Charge Controller, showing the LCD display, MPPT and SET buttons, and USB ports.

Table 1: Product Component Description
No. Component
①LCD
②Temperature sensor interface
③PV input port
④Battery port
⑤Load port
⑥Menu button
⑦Set button
⑧USB output

For a visual overview of the product and its features, please watch the following video:

Video: An overview of the PowMr Keeper Series Solar Charge Controller, detailing its components, available models (20A, 30A, 40A), MPPT charging efficiency, maximum charging current, 3-stage charging algorithm, maximum PV input voltage, system voltage compatibility (12V/24V), DC output, load output modes, temperature compensation, and protection features.

2. Setup and Installation

2.1 Installation Guidelines

Install the controller vertically with its ports facing downward. Secure it to the wall using screws through the four mounting holes.

Diagram showing how to wire the solar charge controller

Figure 2: Wiring diagram for the solar energy system, illustrating the connection sequence for battery, solar panels, and load.

Important Notices:

  • Install the controller in a space with good natural ventilation/exhaust.
  • Avoid direct sunlight.
  • Ensure there is ample clearance around the controller for proper heat dissipation.
  • Install the controller on a non-combustible wall and ensure there are no flammable materials nearby. An increase in temperature during controller operation is a normal occurrence.

2.2 Wiring Precautions

Follow these steps to connect cables and install them correctly:

  1. **Open the cover first:** Locate the screw terminals.
  2. **Wire the battery first:** Connect the battery cables to the designated battery port.
  3. **Then PV:** Connect the solar panel cables to the PV input port.

This series of MPPT controllers uses a common positive design, meaning the positive poles of the PV array, battery, and load can be grounded simultaneously.

Wiring Safety:

  • To avoid short-circuits and polarity reversal, ensure the positive (+) cable is connected to the device's positive (+) terminal and the negative (-) cable to the device's negative (-) terminal.
  • Loose or incomplete connections can lead to cable or terminal overheating. Tighten all cables to minimize transition resistance, using cable sizes appropriate for the specific circuit's current rating.
  • If an inverter or other device with a starting current is used in the system, connect it directly to the battery, not to the controller's load terminal.
  • If a lithium battery is used, set the system voltage and battery type before use. (Refer to Section 3.7 and 3.8 for details).

3. Operation Guide

3.1 LCD Screen Interface

The LCD screen provides real-time operating data and status information. Below are the icons and their meanings:

LCD display interface showing various parameters and settings

Figure 3: At-a-glance display interface, showing main interface, system voltage selection, total charge power, load mode, load disconnect voltage, float voltage, and load reconnect voltage.

Table 2: LCD Status Icons and Meanings
Item Icon Status
PV array(Sun icon)Day
PV array(Moon/Stars icon)Night
PV array(Sun to Battery with MPPT)Charging
Battery(Battery icon)Uncharged/Battery capacity
Battery(LiPo/LiFe)Battery type
Load(Lightbulb on)Load on
Load(Lightbulb off)Load off

3.2 Button Functions

Table 3: Button Definitions
Button Function
MENU (Up Arrow)Short Press: Switch down/next parameter. Hold for 3 seconds: Enter the next interface.
SET (Down Arrow)Short Press: Switch up/previous parameter. Hold for 3 seconds: Exit without saving.

Boot Screen: When the system is powered on, the LCD will display a starting interface, then battery voltage, and finally software revision. This is normal.

Note: From the first interface, long press the "MENU" button to enter the secondary interface. It will automatically switch back to the first interface if no action is taken for 15 seconds.

3.3 Load Switch On/Off

On the main page, a short press of the "SET" button will switch the load on or off. This function is available in any load operating mode.

3.4 Main Loop Pages

After the controller is powered on, the LCD screen will display the main page. Short press "MENU" or "SET" to switch between the main loop pages, which include:

  • Main page (showing current battery voltage)
  • Battery temperature
  • Charging current
  • Discharging current
  • Accumulated charging AH
  • Accumulated discharging AH

3.5 Setting Pages

From the main page, long press "MENU" for 3 seconds to enter the setting page. Then, short press "MENU" or "SET" to navigate through the setting pages. After making changes, long press "MENU" for 3 seconds to save. To exit without saving, long press "SET" for 3 seconds.

Setting pages include:

  • Resume charge voltage
  • Constant voltage charge (CV)
  • Equalization charge
  • Absorption charge
  • System voltage (AUTO, 12V, 24V)
  • Battery type (USE1, GEL, SLD, FLD, 4*3.2, 5*3.2, 3*3.7, 4*3.7, USE2)
  • Low voltage recovery
  • Low voltage protection
  • Float charge voltage
  • Temperature compensation
  • Load working mode

3.6 Battery Type Configuration

To set the battery type:

  1. From the main page, long press "MENU" for 3 seconds to enter the setting page.
  2. Short press "MENU" to navigate to the battery type page (User mode 1).
  3. Once on the battery type page, long press "MENU" for 3 seconds to enter the battery type selection pages.
  4. Short press "MENU" or "SET" to switch between GEL, Sealed, Flooded, and Lithium battery types.

For lithium batteries, you can also set the capacity:

  1. On any lithium battery page, long press "MENU" for 3 seconds to enter the capacity setting program. The parameters on the screen will start flashing.
  2. Keep long pressing "MENU" for 3 seconds until the parameter becomes battery capacity.
  3. Short press "MENU" or "SET" to adjust the capacity of the connected lithium batteries.
  4. After setting, long press "MENU" for 3 seconds to save the data.

Important: For lithium batteries, always set the system voltage before selecting the battery type.

3.7 System Voltage Setting

After configuring the battery type, proceed to set the system voltage. "AUTO" indicates automatic detection of the system voltage.

  1. Enter the setting pages (long press "MENU" for 3 seconds from the main page).
  2. Navigate to the system voltage page.
  3. Long press "MENU" for 3 seconds until "AUTO" starts to flash.
  4. Short press "MENU" or "SET" to select 12V or 24V.

3.8 Load Working Modes

The controller offers four load working modes:

Diagram showing load working modes on the LCD

Figure 4: Load working mode settings, including Manual Mode (24H), Solar Light Control Mode, and Solar Light + Time control.

Table 4: Load Working Modes
Mode Description
LD1 (Manual Mode)The load works normally and can be turned on or off manually.
LD2 (Light Control Mode)The load automatically turns on at dark and turns off at dawn.
LD3 (Light & Time Control Mode)Load working hours after dark, load working hours before dawn. (Automatically identifies dark and light according to local environment). If selected, you can configure the duration of DC output. Select "on" or "off" to activate/deactivate.
LD4 (Reverse Light Control Mode)Load automatically turns on at dawn, load automatically turns off at dark.

In Light Control, Light & Time Control, and Reverse Light Control modes, the controller will start or stop the load with approximately a 30-second delay after light is detected or disappears. The load on/off button on the main page remains functional in any load operating mode.

3.9 PV Voltage Page

Long press "SET" for 3 seconds to switch between the main page and the PV voltage page, which displays the current voltage from the solar panels.

3.10 Setting Equalization and Absorption Charging Duration

To adjust the duration for equalization and absorption charging:

  1. Navigate to the equalization or absorption charging page from the main page.
  2. Long press "MENU" for 3 seconds until the parameter starts to flash.
  3. Keep pressing "MENU" for 3 seconds to enter the duration setting page.
  4. Short press "MENU" or "SET" to increase or decrease the time.

4. Maintenance

Regular maintenance ensures the longevity and optimal performance of your solar charge controller. Consider the following:

  • Cleaning: Periodically clean the controller's exterior to prevent dust buildup, especially on cooling fins, which can impede heat dissipation. Use a soft, dry cloth.
  • Connections: Annually check all wiring connections (PV, battery, load) for tightness. Loose connections can cause resistance, heat, and potential system malfunction.
  • Ventilation: Ensure the installation area maintains good ventilation and is free from obstructions that could block airflow to the controller.
  • Environmental Check: Verify that the controller is not exposed to direct sunlight, excessive moisture, or extreme temperatures outside its operating range.
  • Battery Health: Monitor battery voltage and performance. Ensure the battery type settings in the controller match your installed battery.

5. Troubleshooting and Fault Management

The controller features various protection functions and displays error codes to help diagnose issues. The fault code consists of an "E" followed by two digits. The first digit represents the current error count, and the second digit indicates the specific fault condition. For example, "E-2" means there is one error, and the specific reason is overvoltage in the battery.

5.1 Protection Functions

Table 5: Protection Functions
Protection Condition Status
Solar panel reversedSolar panel can be reversed if battery is not connected.Controller isn't broken.
Battery is reversedBattery can be reversed if PV is unconnected.Controller isn't broken.
Battery over-voltageBattery voltage reaches the over-voltage point.Stop charging and discharging.
Battery over-dischargeBattery voltage drops below the under-voltage point.Stop discharging.
Over-loadThe load current exceeds the rated current.Turn off the output.

5.2 Fault Management Table

Table 6: Error Codes and Solutions
Error Code Cause Correction
PV array indicator is off when sunlight is enough.Solar panel is disconnected.Check whether PV array connection is proper or not.
No sign on the LCD when connection is right.1. Battery voltage is less than 8V.
2. Voltage of solar panel is less than battery voltage.
1. Check battery voltage (at least 8V to activate the controller).
2. The voltage of PV must be higher than battery voltage.
E1 (Ex1)Battery over discharge.The load will stop automatically and recover when battery voltage reaches 12.6V (LVR).
E2 (Ex2)Battery over voltage.Make sure the settled value of high voltage disconnection voltage is over battery voltage and reconnect PV array.
E3 (Ex3)Over load.Reduce load or check load connection.
E5 (Ex5)Controller overheating.The controller will restart after it cools down.
E6 (Ex6)Input voltage of solar panel is too high.Check voltage of solar panel and reduce quantities of solar panel in series.
E7 (Ex7)No operation.Controller will restart after setting system voltage.

6. Specifications

Table 7: Technical Data
Parameter 20A Model 30A Model 40A Model
PV Input
Max. open voltage of PV array<60V<75V<100V
System rated voltage12/24V Auto recognized
Battery voltage range8V~32V
Maximum input power260W(12V)
520W(24V)
390W(12V)
780W(24V)
520W(12V)
1040W(24V)
DC Output
Rated Charge Current20A30A40A
Rated Discharge Current20A20A30A
Battery typeUser default, Sealed, Flooded, GEL, LiFePO4, Li(NiCoMn)O2
Equalize charging voltage*Maintenance-free lead-acid battery: 14.6V; GEL: 14.2V; Flooded battery: 14.6V. Duration: 2 hours.
Absorption charging voltage*Maintenance-free lead-acid battery: 14.4V; GEL: No; Flooded battery: 14.8V. Duration: 2 hours.
Float charging voltage*Maintenance-free lead-acid battery, GEL, Flooded battery: 13.8V.
LVR* (Low Voltage Recovery)Maintenance-free lead-acid battery, GEL, Flooded battery: 12.6V.
LVD* (Low Voltage Disconnect)Maintenance-free lead-acid battery, GEL, Flooded battery: 10.8V.
Static loss≤50mA
HVD (High Voltage Disconnect)Lead acid battery 16V
Light control voltage5V/10A
Temperature compensation coefficient-4mV/°C/2V (25°C)
Discharge loop voltage drop≤0.2V
LCD temperature-20°C ~ +70°C
Operating temperature-20°C ~ +55°C
Storage temperature-30°C ~ +80°C
Working humidity≤90%, No condensation
Protection classIP30
Grounded typePositive grounded
Aperture for installationΦ5mm

*Note: Above parameters are for 12V system at 25°C; values are twice for 24V system.

7. User Tips

  • Ensure all connections are secure and follow the correct wiring sequence (battery first, then PV) to prevent damage.
  • Verify battery type and system voltage settings are correctly configured for your specific battery bank to optimize charging and prolong battery life.
  • Regularly check the LCD display for operational status and any error codes to quickly identify and resolve potential issues.

8. Warranty and Support

For technical support, warranty claims, or any inquiries regarding your PowMr Keeper Series Solar Charge Controller, please contact the manufacturer using the details below:

  • Manufacturer: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
  • Email: support@powmr.com
  • Website: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
  • Tel/Fax: +86 755-28219903

A user manual in PDF format is also available for download: PowMr Keeper Series User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.