1. General Information
The EMS Body Sculpt series utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.
1.1 Indications for Use
The MYoslim EMS Body Sculpt machine is intended for:
- Improvement of abdominal tone, strengthening of the abdominal muscles, development of fitter abdomen.
- Strengthening, toning, and firming of buttocks, thighs, and calves.
- Improvement of muscle tone and firmness, for strengthening muscles in arms.
1.2 Operating Environment
The operating environment of the EMS Body Sculpt instrument series is crucial to ensuring the effectiveness and safety of the device.
- Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
- Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
- Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
- Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
- Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
- Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
- Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.
1.3 Patient Profile
This machine is suitable for adults who are seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies.
1.4 Description of the Device
The EMS Body Sculpt enables a simple and effective treatment process by adjusting the digital energy selection treatment plan or diagnostic procedure. Treatment parameters can be manually adjusted via the touch screen. Precise and effective treatment plans can be configured by selecting the age group and gender of the person being treated.
The touch-controlled display simplifies operation and offers clear visibility. Its brightness is adjustable for different lighting conditions. The screen guides you through the entire treatment process, showing remaining time, utilized channels, treatment methods, and attachments used.
The EMS Body Sculpt series offers flexible upgrade options to meet future treatment requirements.
2. Safety Precautions and Warnings
Precautions Before Use:
- Do not use when feeling full; wait at least one hour after meals.
- Before using the instrument, remove any metal jewelry.
- Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
- Start at the lowest intensity level and gradually increase it according to the user's skin tolerance.
- It is forbidden to eat or drink during the operation. Avoid eating for at least one hour after the operation.
1.5 Contraindications:
Do not use the device if any of the following conditions apply:
- Wounds on the skin (or avoid wounds when using).
- Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
- Cancer patients.
- Patients with infectious diseases.
- Pregnant women, lactating women, or during menstrual period.
- Major surgery patients, diabetic patients.
- Individuals with any metal implants in the body.
- People with cerebrovascular disease (stroke patients).
1.6 Possible Side Effects:
These effects may include but are not limited to:
- Muscle soreness.
- Reduction in muscle fat.
- Temporary muscle spasms.
- Transient joint or muscle tendon pain.
- Localized redness or skin flushing.
3. Device and Accessories
3.1 Front and Rear Panel of the Main Unit
The main unit features a display screen, EMS handles, and an On/OFF button on the front. The rear panel includes connections for the handles, a fuse, and the power plug.
Front view of the MYoslim EMS Body Sculpt machine with its touchscreen display and two handles.
Rear view of the MYoslim EMS Body Sculpt machine showing power input and handle connections.
3.2 Handle
The device uses specialized handles for treatment. Note: The handle can only be used by the original machine and cannot be used interchangeably.
Close-up of the MYoslim EMS handle with 'myoslim' branding.
3.3 List of Accessories
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host | 1 set | ![]() |
| 2 | Handle | 2 | ![]() |
| 3 | Belt | 2 | |
| 4 | Power cable | 1 | |
| 5 | Electronic manual | 1 copy |
4. Device Installation
-
Install the handle bracket
Need a screwdriver to install the handle bracket on both sides of the machine. Ensure successful installation.
-
Handle film
Stick the black film to the working part of the handle.
-
Installing the handle
Align the hole and fasten the clip. Lock the key ring to secure the handle.
-
Connect power
Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the same socket.
-
Press on the back switch
Press the back switch to turn the machine on (light will be on) or off (light will be off).
-
Press the front switch
Single-click the front button to power on. Long press to power off.
5. Basic Device Operation
5.1 Handle Exchange
The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
5.2 Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the "o" position.
- Press the button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
5.3 Navigation Controls
5.3.1 Setting the Therapy by Controls
Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:
MYoslim machine screen showing Pattern 1 treatment settings with energy and time adjustments.
- Navigation controls
- Channels selector
- Stop therapy
- Start/pause therapy
- Setting up therapy parameters
5.4 Unit Settings
The device offers various unit settings accessible via the main menu:
- Language settings: Adjust the display language.
- Sound adjustment: Control the device's audio feedback.
- Brightness adjustment: Modify screen brightness for optimal visibility.
- Set date time: Configure the current date and time.
- System adjustment: Access advanced system configurations.
- Technician: Password-protected access for service technicians.
Operating Mode 1: This mode allows adjustment of energy and RF levels, and treatment time. Select the desired pattern, adjust parameters, and press play. You can also select gender, region (abdomen, buttocks, other), and age group (<30, 40-49, 50-59, 60+).
Operating Mode 2: This mode allows adjustment of energy, F1, F2, F3 frequencies, RF, and treatment time. It features three different periods of frequency for free adjustment. Adjust the corresponding intensity/stage frequency/time according to customer needs, then click the start/pause button to begin. If a pause is needed, click the start/pause button. After completion, click the return key.
Video demonstrating the MYoslim EMS Body Sculpt machine's touchscreen interface and operation.
6. Therapy
6.1 Preparing the Therapy
- Communicate with patients.
- Ensure good health.
- Stay hydrated.
- Wear appropriate clothing.
- Avoid eating in large quantities.
- Familiarize yourself with the treatment process.
- Avoid drinking alcohol.
6.2 Placing the Handle
Proper placement of the handles is crucial for effective treatment. Please refer to the images below for guidance on handle placement for different body areas.
Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.
7. Maintenance and Repair
7.1 Maintenance
7.1.1 Daily Inspection
Managers must regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Please check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.
7.1.2 Cleaning
Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off.
7.1.3 Replacing the Fuse
When replacing the fuse, to prevent electric shock, turn off the power and unplug the power plug.
7.2 Repair
After purchasing the instrument, you need to fill in the warranty card and send it to the manufacturer or agent for warranty. From the date of purchase, if a product quality problem occurs, a free warranty is provided for one year (warranty requires a warranty card and purchase bill, and is limited to the instrument host, excluding accessories and other consumables). After the warranty period, contact the manufacturer directly for paid after-sales service. Do not repair the machine without authorization. Any unauthorized unpacking will void the warranty.
8.1 Fuse Replacement
The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included.
8.2 Cleaning of the Surface of the Device
The logo of the machine is painted by silk screen printing process. The rest of the parts are painted with a spray painting technique. Use cotton paper towels or ordinary toilet paper moistened with water to wipe clean; do not use alcohol-based detergents.
8.3 Cleaning of Accessories that Come into Contact with Patient
The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole; wipe with pure cotton material.
8.4 Transport and Storage
Storage: The instrument should be stored in the original packaging box, placed in a well-ventilated room. The packaging box should be padded. The ambient temperature should be -10°C to 40°C, and the relative humidity should not be greater than 93%. It is not allowed to be placed near flammable, explosive substances, and corrosive gases.
Transportation: The instrument, under packaging conditions, is suitable for road, railway, air, and water transportation. During loading, unloading, and transportation, it should prevent severe vibration and shock, and should not be affected by moisture. It should not be mixed with flammable and corrosive substances. Specific requirements are specified in the order contract.
8.5 Term of Use
- The warranty period of this instrument is 1 year (note: man-made damage is excluded).
- The warranty period for accessories is 3 months (note: man-made damage is excluded).
- The continued use of the instrument beyond the service period shall be subject to the approval of the engineer, and the engineer shall conduct a performance test of the instrument periodically in the subsequent use.
- Scrap instruments and accessories beyond their useful life should be disposed of according to local regulations.
8.6 Common Faults and Troubleshooting Methods
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working |
|
|
| Handle not working | Check the handle for loose connection. | Reseat the handle. |
9. Technical Specifications
| Name | Value |
|---|---|
| Model | E-14 |
| Input power supply | AC110V-220V 50/60Hz |
| Output maximum power | 0-6500W |
| Frequency | 5-200Hz |
| Screen size | 15 inches |
| Machine color | White/Black |
| Number of Lamp Heads | 1 |
| Power Type | Electric |
| Power Source | Electric |
| Use | BODY |
| Origin | Mainland China |
| Warranty | 1 years |
| Style | PORTABLE |
| Packaging Details | Air Box |
| Intensity | 15 Tesla |
| Feature | Weight Loss |
| Cooling system | intelligent air cooling system |
| Target area | body, legs/arms, hands, abdomen, buttocks |
| Function 1 | Shape |
| Function 2 | Slimming |
| Function 3 | Body shaping |
9.1 Electromagnetic Compatibility
The device complies with IEC 61000-4-3:2020 for radiated electromagnetic field immunity test. Test level: 30V/m with 80% AM, 1kHz Modulation.
Test Equipment:
| Description | Manufacturer | Model | Identifier | Cal. Date | Cal. Due |
|---|---|---|---|---|---|
| Signal Generator | IFA | 2023B | N/A | 15/03/2022 | 14/03/2023 |
| Power Amplifier | AR | 150W1000 | N/A | 15/03/2022 | 14/03/2023 |
| Power Antenna | AR | 25S1G4A | N/A | 15/03/2022 | 14/03/2023 |
10. Warranty and Support
Warranty Card Information
The machine can be replaced with a new one within 7 days from the date of purchase (with the receipt) if it has an intact appearance. The main machine is guaranteed for one year (except for fragile parts, and other non-warranty scope or expired warranty period). Maintenance and updates may be provided, with appropriate charges. If the instrument is broken and needs to be sent back for repair, the buyer shall bear the return shipping cost within six months from the date of purchase, and the seller shall bear the shipping cost. After six months, the buyer bears all shipping costs.
Free warranty service is not provided for failures caused by personal reasons, including:
- Faults caused by unauthorized disassembly and modification of this product.
- Faults caused by accidental fall.
- Failure caused by lack of reasonable maintenance.
- Failure to operate according to the correct instructions in this instruction manual.
Manufacturer
Guangzhou Xinwei Electronic Technology Co., Ltd.
After-Sale Service
We have a professional technology supporting team for your timely services. You can get the help you need in time by telephone, webcam, online chat (Google talk, Facebook, Skype). Please contact us once the machine has any problem. Best service will be offered.
We can provide a complete user manual and usage video for instruction and application. And 24/7 online consultant service ensure you whatever problem and whenever you meet, you can solve easily. It is easy to operate by anyone with the instructions.
User Tips
- The MYoslim sculpt device offers non-invasive results, helping to build lean muscle and tighten sagging skin without downtime or side effects.
- Adjustable intensity settings make the treatment safe and comfortable for various clients.
- Consistent sessions contribute to long-lasting fat reduction results.
- The machine's sleek, professional design and responsive touchscreen are user-friendly and enhance the client experience.
- Multilingual settings can be beneficial for serving a diverse clientele.
- The EMS technology can reduce muscle recovery time by up to 40%, making it suitable for sports recovery programs.
- Ergonomic handles ensure comfort for both the client and the operator during treatments.
- The strong and stable energy output leads to faster and more noticeable results.
- For home users, the 30-minute sessions are convenient and effective for body care, with visible results like firmer thighs after consistent use.
- The device is durable, runs quietly, and is built with outstanding quality.
- Many users have reported visible waistline reduction and hip lifting effects, with before and after photos showing reduced belly fat and tighter thigh skin.
- It is also effective for post-pregnancy body recovery, helping to tighten the abdomen and build core strength safely.
Frequently Asked Questions (FAQ)
- Q: What certifications does the machine have?
- A: All of our machines have CE certification, ensuring quality and safety. Our machines are under strict quality management.
- Q: Is training provided on how to use the machine?
- A: Yes, a complete user manual and usage video are provided for instruction and application. Additionally, 24/7 online consultant service is available to help with any problems.
- Q: Why should I choose this machine?
- A: This machine comes from a powerful factory, offering competitive pricing and strong technology support. It benefits from 10 years of experience in beauty machine production, strong R&D, a 1-year warranty, and 24/7 online after-sale service. It also has CE Certification and offers diversity in customized services (OEM & ODM capability).