Myoslim Myoslim EMS + Inner Ball Roller 2-in1 Body Sculpting Machine

Contents

Myoslim EMS + Inner Ball Roller Body Sculpting Machine User Manual

Model: Myoslim EMS + Inner Ball Roller 2-in1 Body Sculpting Machine

1. Introduction

Thank you for choosing the Myoslim EMS + Inner Ball Roller Body Sculpting Machine. This instrument is designed to provide effective body shaping, muscle stimulation, and cellulite reduction through a combination of Electrical Muscle Stimulation (EMS) and mechanical compression micro-vibration with infrared treatment. Please read this manual carefully before use to ensure safe and optimal operation.

1.1. Product Overview

This instrument is a two-in-one body shaping device, primarily composed of a main machine, an EMS handle, and an inner ball roller handle. It is designed for general human body shaping.

1.2. Working Principles

1.2.1. EMS Handle Principle

The EMS handle utilizes HI-EMT (High Energy Focused Electromagnetic Waves) technology. This technology continuously expands and contracts muscles, performing extreme training that deeply remodels the internal structure of muscles. This process leads to the growth of myofibrils (muscle enlargement) and the generation of new protein chains and muscle fibers (muscle hyperplasia), thereby increasing muscle density and volume. The intense muscle contraction induced by HI-EMT technology can also trigger significant fat breakdown, where fatty acids are decomposed and released from triglycerides, accumulating in adipocytes. High levels of fatty acids cause fat cells to die and be naturally excreted by the body within weeks.

1.2.2. Inner Ball Roller Handle Principle

The inner ball roller handle employs a non-invasive method combining mechanical compression micro-vibration with infrared treatment. The mechanical compression micro-vibration principle involves a ball rotating 360 degrees along its axis. This rotation and rolling generate compression micro-vibration. As the ball rotates and exerts pressure on the skin, it creates a "pulsating compression" effect, facilitating continuous push-pull and kneading motions. This process gently and effectively tightens skin tissue without causing damage. The infrared therapy component releases infrared rays, promoting cell metabolism, enhancing oxygen-blood combination, reducing cellulite, and alleviating muscle stiffness and soreness, ultimately promoting cell activity and reshaping the body.

1.2.3. Benefits of Inner Ball Roller Handle

  • Reshapes body contour and smooths wrinkles.
  • Enhances muscle toughness and tightens skin.
  • Improves blood oxygen binding degree and relieves muscle fatigue.
  • Reduces toxins through lymphatic drainage.
  • Promotes blood circulation and cell metabolism.
Product efficacy icons: gain muscle, lose weight, scientific slimming, lazy fitness

Product efficacy: Gain muscle, lose weight, scientific slimming, lazy fitness.

Diagram showing the inner ball roller working principle at different depths: subcutaneous fat layer (6mm), superficial muscular layer (10mm), middle muscular layer (18mm), deep muscular layer (35mm).

Inner Ball Roller Working Principle: Non-invasive mechanical compression micro-vibration plus infrared treatment, reaching various tissue depths.

Benefits of the machine: Improve lymphatic drainage and circulation, deep detoxification, reduce muscle stiffness and soreness, decompose subcutaneous fat deposits, eliminate orange peel tissue, reduce fat mass and shape contours.

Key benefits of using the Myoslim machine.

1.3. Characteristics of Inner Ball Roller Handle

  1. Unique 360° intelligent rotating drum handle, ensuring continuous long-term operation, safe and stable.
  2. An LED display on the handle shows the current speed.
  3. The roller handle includes a key for controlling start or pause.
  4. The steel balls are flexible and smooth, providing effortless and gentle rolling without stinging, ensuring smooth and even pressure for optimal massage and lifting results.
  5. No need for the user to massage hard; operation is simple and safe.

2. Safety Information & Contraindications

2.1. General Safety

Our company is responsible for the safety and reliability of the instrument under the following conditions:

  • Installation, reorganization, modification, and maintenance are carried out by professionals designated or authorized by the company.
  • Electrical equipment connected to the instrument meets the technical parameters specified in this manual.
  • Operation is performed strictly according to this user manual.

Failure to use the instrument normally may lead to malfunction or endanger human health. All consequences arising from use outside the specified operations are the user's responsibility.

2.2. Precautions Before Use

  • Do not use the instrument immediately after a full meal; wait at least one hour.
  • Remove any metal jewelry before using the instrument.
  • Before starting operation, position the EMS handle vertically on the treatment area. Adjust the intensity using the main switch, starting from the lowest level and gradually increasing according to skin tolerance.
  • Do not eat or drink during operation. Wait at least one hour after operation before consuming food or beverages.

2.3. Contraindications

The instrument should NOT be used by individuals with:

  • Large wounds or ulcers on the skin.
  • Heart disease (e.g., arrhythmia), especially those with pacemakers.
  • Cancer.
  • Infectious diseases.
  • Pregnancy, lactation, or menstruation.
  • Major surgical history or diabetes.
  • Any metal implants in their body.
  • Cerebrovascular disease (e.g., stroke).

2.4. Precautions During and After Use

  • Replenish water promptly after use.
  • Avoid overeating; maintain a balanced diet and adequate sleep.
  • Strengthen moisturizing and sun protection after use.
  • Avoid spicy foods.
  • Avoid hot springs and saunas for three days after use.

3. Product Components & Diagrams

3.1. Packing List

SerialNameQuantity
1Host Machine1 set
2EMS Handle2
3Inner Ball Roller Handle (Big)1
4Inner Ball Roller Handle (Small)1
5Bandage (100*7cm)2
6Power Cable1
7Abdominal Muscle Piece and Connecting Line1
8Electronic Manual1 copy

3.2. Instrument Views

3.2.1. Front View

Front view of the Myoslim machine showing the main screen, EMS handles, and inner ball roller handles.

Front view of the Myoslim machine with main screen, EMS handles, and inner ball roller handles.

  • Host Machine: The central unit housing the control panel and power.
  • Touch Screen: 10.4-inch resistance screen for interface control.
  • EMS Handle: Used for muscle stimulation.
  • Inner Ball Roller Handle (Big/Small Wheel): Used for mechanical compression and infrared treatment.
  • On/OFF Button: Main power control.

Note: All handles can only be operated by professional operators.

3.2.2. Back View

Back view of the Myoslim machine showing ports for EMS handles, roller handles, and power plug.

Back view of the Myoslim machine, highlighting connection ports and handle hangers.

  • Port of EMS Handle: Connection points for the EMS handles.
  • Port of Roller Handle: Connection points for the inner ball roller handles.
  • Handle Hanger: Storage for the handles when not in use.
  • Power Plug: Main power input.
  • Switch: Power switch.

3.2.3. Handle Display

Image showing the EMS handle and inner ball roller handle designs.

EMS handle and inner ball roller handle designs.

4. Setup

  1. Unpacking: Carefully remove all components from the packaging. Retain the original packing box for future storage or transportation.
  2. Placement: Place the main machine on a stable, flat surface in a well-ventilated room, away from direct sunlight, moisture, and harmful gases.
  3. Handle Attachment: Connect the EMS handles and inner ball roller handles to their respective ports on the back of the main machine. Ensure connections are secure.
  4. Power Connection: Connect the power cable to the power plug on the back of the machine and then to a suitable AC 110V-220V 50/60Hz power outlet. Ensure the power switch is in the OFF position before plugging in.
  5. Initial Check: Before turning on, ensure all connections are firm and the handles are properly seated in their hangers.

5. Operation

5.1. Power On/Off

  1. Power On: Press the On/OFF button on the front of the machine. The touch screen will light up, displaying the Myoslim logo and then the main function selection interface.
  2. Power Off: From the main interface, press the On/OFF button. A prompt will appear asking "Are you sure you want to shut down the device?". Confirm to shut down.

Video demonstrating the power-on sequence and basic interface navigation.

5.2. Interface Overview and Function Selection

The main interface allows you to select between two primary functions: EMS and WHEELS (Inner Ball Roller).

Newly upgraded HD touch screen interface showing language, EMS interface, Home, and Roller interface options.

Newly upgraded HD touch screen interface with various settings and mode selections.

5.3. EMS Handle Operation

  1. Select EMS: From the main function selection interface, tap on "EMS". This function has two working modes: List and Pattern.
  2. User Information Setting (Pattern Mode): If using Pattern mode, you can set training type, gender, position, and age. After setting, click the confirmation button to return to the main interface, and the EMS handle will start working.
  3. Parameter Adjustment: On the EMS operation interface, you can adjust the following parameters:
    • Time: 1-60 minutes.
    • Speed (Intensity): 0-100%.
    • Light: Blue light / Red light (if available).
  4. Start/Pause: Use the Start/Pause button to begin or temporarily stop the treatment.
  5. Stop Therapy: Select "Shut down the handle" to end the session.
  6. Save Settings: You can save custom settings for future use.

5.4. Inner Ball Roller Handle Operation (WHEELS)

  1. Select WHEELS: From the main function selection interface, tap on "WHEELS". This function has two handle modes: Big Wheel and Small Wheel.
  2. Parameter Adjustment: On the Inner Ball Roller operation interface, you can adjust the following parameters:
    • Time: 1-60 minutes.
    • Speed (Intensity): RF, 0-50.
    • Rotational Speed: 0-10 (rpm).
    • Rotation Direction: FWD (clockwise) / REV (counterclockwise).
  3. Application: Apply a suitable gel or cream to the treatment area. Gently press the inner ball roller handle against the skin. When the handle contacts the skin, the blue light will turn red, indicating proper contact.
  4. Start/Pause: Use the Start/Pause button to begin or temporarily stop the treatment.
  5. Stop Therapy: Select "Shut down the handle" to end the session.
  6. Save Settings: You can save custom settings for future use.

5.5. Applicable Areas

The Myoslim machine can be applied to various body parts for shaping and muscle stimulation:

Diagram showing various body areas for treatment: Face, Neck, Shoulder, Arm, Chest, Back, Abdomen, Hips, Legs.

Applicable body areas for treatment.

  • Face
  • Neck
  • Shoulder
  • Arm
  • Chest
  • Back
  • Abdomen
  • Hips
  • Legs
  • Loin
  • Buttock
  • Calf
  • Thigh

6. Maintenance

6.1. Daily Inspection

  • Check instruments and components regularly for any visible damage or wear.
  • Regularly check whether the connection between the power socket and the grounding wire is reliable.

6.2. Cleaning

  • Clean the instrument regularly to ensure sanitary conditions and normal operation.
  • Before cleaning, turn off the power of the instrument and unplug it.
  • Wipe the equipment shell with a soft cloth dampened with soapy water or a neutral detergent.
  • Do not clean internal circuits with liquids.

6.3. Fuse Replacement

  • To prevent electric shock, always turn off the power supply and unplug the instrument before replacing the fuse.
  • Refer to the specifications for the correct fuse type (500V 3A Φ6×30).

7. Troubleshooting

Fault PhenomenonCausesExclusions and Workarounds
Device not working
  • Power plug not inserted into the socket.
  • Power switch not on.
  • Power fuse failure.
  • Check the power connection.
  • Check the power switch.
  • Replace the fuse.
Handle not workingHandle is loose.Reposition the handle firmly.

8. Specifications

8.1. Main Machine Technical Parameters

ParameterValue
Input PowerAC 110V-220V 50/60Hz
Screen Size10.4 inches
Screen TypeResistance Screen
Screen Resolution1024*768
Equipment Size52 x 32 x 43 cm
Net Weight of Equipment16.6 kg
Packing Size59 x 50 x 52 cm
Packing Weight38 kg
Fuse500V 3A Φ6×30

8.2. EMS Handle Parameters

ParameterValue
Input Maximum Power1500 VA
Frequency10-200Hz
Magnetic Flux Density5T

8.3. Roller Handle Parameters

ParameterValue
Input Maximum Power200 VA
Frequency448KHz
Small Handle Speed400rpm
Large Handle Speed400rpm

9. User Tips

  • For best results, maintain a consistent treatment schedule and combine with a healthy diet and regular exercise.
  • Always apply a conductive gel or cream to the skin before using the inner ball roller handle to ensure smooth gliding and effective treatment.
  • Start with lower intensity settings and gradually increase as your body adapts. Comfort is key.
  • Hydration is crucial; drink plenty of water before and after sessions to support lymphatic drainage and overall well-being.
  • Pay attention to your body's signals. If you experience any discomfort or adverse reactions, stop the treatment immediately.

10. Warranty & Support

10.1. Warranty Information

  • The mainframe of this instrument is guaranteed for one year from the date of purchase (excluding fragile parts and other non-warranty parts or expired warranty periods).
  • Accessories have a warranty period of 3 months.
  • Free warranty service is not provided for failures caused by personal reasons, including:
    • Unauthorized disassembly and modification of the product.
    • Accidental falls.
    • Lack of reasonable maintenance.
    • Failure to follow the correct instructions in the manual.
  • If the instrument is damaged and requires repair, the company will cover all freight costs within six months from the date of receipt. For periods between six months and one year, freight costs will be shared equally between the buyer and the company. After one year, the buyer is responsible for all freight costs.
  • Continued use of the instrument after the warranty period must be approved by an engineer, with regular performance tests.

10.2. Storage and Transportation Management

  • Storage: Store the instrument in its original packing box in a well-ventilated room. Maintain an ambient temperature of -10°C to 40°C and relative humidity not exceeding 93%. Avoid storing near harmful gases, flammable, explosive, or corrosive substances.
  • Transportation: The instrument, in its original packaging, is suitable for road, railway, air, and water transportation. Prevent serious vibration during loading, unloading, and transportation. Protect from moisture and avoid mixing with flammable or corrosive substances.

10.3. Disposal

Abandoned instruments and accessories that have exceeded their service life should be disposed of according to local laws and regulations.

10.4. Contact Support

If you have any questions, require service, or need further information, please contact your supplier or the manufacturer directly.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.