1. Introduction
This PowMr multi-function inverter/charger combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support in a compact size. Its comprehensive LCD display allows for user-configurable and easily accessible button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage, adapting to various applications.
1.1 Key Features
- Pure Sine Wave Inverter
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible with mains voltage or generator power
- Auto restart while AC is recovering
- Overload, Over temperature, and Short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
- Dual AC output (Main and Second load)
- Equipped with 3 cooling fans for efficient heat dissipation
- Demountable insect screen for easy cleaning
- Built-in MPPT charging control module
- Wide PV input voltage range of 90-500V
- Dual-channel AC output configuration of up to 10.2KW
1.2 Basic System Architecture
The inverter/charger is designed to integrate seamlessly into various power systems. A complete running system typically includes the inverter/charger, a generator or utility power source, and PV modules. Consult with your system integrator for specific architectural needs. This inverter can power a wide range of appliances in home or office environments, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners.



2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION - Only qualified personnel can install this device with a battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow the required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
- Please strictly follow the installation procedure when you want to disconnect AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.
3. Installation
3.1 Unpacking and Inspection
Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain the following items:
- The unit x 1
- User manual x 1
- Ring terminal x 1
- MC4 terminal head x 2
3.2 Product Overview

- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Touch Function buttons
- Power on/off switch
- AC input
- Main output
- Second output
- PV1 and PV2 input
- WIFI communication/RS-232 port
- Battery communication/RS-485 port
- Battery input
- Anti dust kit
3.3 Preparation
Before connecting any lines, remove the screws under the machine and detach the bottom cover plate.
3.4 Mounting the Unit
Consider the following points when selecting a mounting location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm on both sides and above the equipment, and 50 cm below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Ensure enough space from other objects and surfaces for adequate heat dissipation and room to remove wires.
! SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two M4 or M5 screws into the wall.

3.5 Battery Connection
CAUTION: For safety and regulation compliance, it's recommended to install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the table below for typical amperage as required fuse or breaker size.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce the risk of injury, use the proper recommended cable as below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 8.2KW/10.2KW | 1 x 2AWG | 25 | 2 Nm |
Follow these steps for battery connection:
- Remove 18 mm of insulation sleeve for positive and negative conductors.
- It is recommended to use bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram below.
- Insert the battery wires flatly into the battery connectors of the inverter and ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify that the polarity at both the battery and the inverter/charger is correctly connected and that conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure that positive (+) is connected to positive (+) and negative (-) is connected to negative (-).
3.6 AC Input/Output Connection
CAUTION!! Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and fully protected from overcurrent of AC input. The recommended spec for the AC breaker is 63A for 8.2KW/10.2KW.
CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce the risk of injury, use the proper recommended cable size as below.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 8.2KW/10.2KW | 10 AWG | 6 | 1.2 Nm |
Follow these steps to implement AC input/output connection:
- Before making AC input/output connection, ensure the DC protector or disconnector is open.
- Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3 mm.
- Insert AC input wires according to the polarities indicated on the terminal block and tighten the terminal screws. Ensure to connect the PE protective conductor (ground) first.
- Ground (yellow-green)
- L → LINE (brown or black)
- N → Neutral (blue)

WARNING: Ensure that the AC power source is disconnected before attempting to hardwire it to the unit.
- Then, insert AC output wires according to the polarities indicated on the terminal block and tighten the terminal screws.
- L → LINE (brown or black)
- N → Neutral (blue)
- Make sure the wires are securely connected.

3.7 PV Connection
CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce the risk of injury, use the proper recommended cable size as below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 8.2KW/10.2KW | 1 x 10AWG | 6 | 1.2 Nm |
PV Module Selection
When selecting PV modules, consider these parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| INVERTER MODEL | 8.2KW/10.2KW |
|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc |
| PV Array MPPT Voltage Range | 90Vdc~450Vdc |
Example: For a 250Wp PV module (Vmp: 30.1Vdc, Imp: 8.3A, Voc: 37.7Vdc, Isc: 8.4A, Cells: 60), recommended module configurations are:
| SOLAR INPUT (Min in serial: 6 pcs, max. in serial: 13 pcs) | Q'ty of panels | Total input power |
|---|---|---|
| 6 pcs in serial | 6 pcs | 1500W |
| 8 pcs in serial | 8 pcs | 2000W |
| 12 pcs in serial | 12 pcs | 3000W |
| 13 pcs in serial | 13 pcs | 3250W |
| 12 pieces in serial and 3 sets in parallel | 36 pcs | 8200W |
| 10 pieces in serial and 4 sets in parallel | 40 pcs | 10200W |
PV Module Wire Connection
Step 1: Check the input voltage of the PV array modules. The acceptable input voltage of the inverter is 90VDC-500VDC. Ensure that the maximum current load of each PV input connector is 18A.
CAUTION: Exceeding the maximum input voltage can destroy the unit!! Check the system before wire connection.
Step 2: Disconnect the DC circuit breaker.
Step 3: Assemble the provided PV connectors with PV modules using the following steps:
| Component | Image |
|---|---|
| Female connector housing | ![]() |
| Female terminal | ![]() |
| Male connector housing | ![]() |
| Male terminal | ![]() |
| Crimping tool and spanner | ![]() |
Cable Preparation and Connector Assembly Process
Strip one cable 8 mm on both ends, being careful not to nick conductors.

Insert the striped cable into the female terminal and crimp it as shown in the diagrams. Then, insert the assembled cable into the female connector housing.

Insert the striped cable into the male terminal and crimp it as shown in the diagrams. Then, insert the assembled cable into the male connector housing.

Use a spanner to screw the pressure dome tightly to the female and male connectors. Check the correct polarity of the connection cable from PV modules and PV input connectors. Connect positive pole (+) of the connection cable to positive pole (+) of the PV input connector. Connect negative pole (-) of the connection cable to negative pole (-) of the PV input connector.

3.8 Final Assembly
After connecting all wirings, replace the bottom cover by screwing in the two screws.
3.9 Communication Connection
Wi-Fi Cloud Communication (Optional)
Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the "SMARTESS" app from the App Store or Google Play. Refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be displayed via the mobile phone app or a computer webpage.

GPRS Cloud Communication (Optional)
Use the supplied communication cable to connect to the inverter and GPRS module, then apply external power to the GPRS module. Download the app and install it from the app store. Refer to the "GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be displayed via the mobile phone app or a computer webpage.
Battery Communication
Communication between the battery and the inverter is achieved through the battery communication interface, allowing the inverter and lithium battery to exchange information (Baud rate: 9600).
Lithium Battery and Inverter Connection
If using a lithium battery, only lithium batteries matched with the BMS communication protocol are allowed.
- Connect the battery according to the recommended battery cable specifications.
- Insert the ring terminal of the battery cable into the battery connector of the inverter flatly, and ensure that the bolts are tightened with a torque of 2-3 Nm. Verify that the polarities of the battery and inverter are correctly connected, and that the ring terminal is tightened with the battery terminal.
- Connect one side of the RJ45 cable to the BMS communication port of the inverter.
- Insert the other side of the RJ45 cable into the RS485 communication port on the lithium battery.
NOTE: If you choose a lithium battery, ensure to connect the battery and inverter with a BMS communication cable, and select the battery type as "LIB-485" mode.
Communication and Setting of Lithium Battery
Connect the RJ45 communication cable between the inverter and battery. Confirm that the lithium battery BMS port's PIN corresponds with the inverter BMS communication port. The inverter BMS port PIN definition is as below:
| Pin number | Port definitions |
|---|---|
| 1 | RS485B |
| 2 | RS485A |
| 3 | NG |
| 4 | NG |
| 5 | NG |
| 6 | NG |
| 7 | RS485A |
| 8 | RS485B |

To communicate with the lithium battery BMS, press and hold the "ENTER" button for a long time, and set the battery type as "LIB-485" in program 05. Then select the matching battery protocol in Program 43.
CAUTION: When the battery type is set to "LIB-485", the setting items 12, 13, and 29 are displayed in percentage. The user cannot modify the maximum charging current. If communication fails, the inverter will cut off the output.
4. Operation
4.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

4.2 Operation and Display Panel
The operation and display panel is located on the front of the inverter. It includes three indicators, four function keys, and an LCD display, showing operating status and input/output power information.

LED Indicator
| Indicator | LED Status | Messages |
|---|---|---|
| INV/AC | Green Solid On | Output is powered by utility in Line mode. |
| Green Flashing | Output is powered by battery or PV in battery mode. | |
| CHG | Green Solid On | Battery is fully charged. |
| Green Flashing | Battery is charging. | |
| FAULT | Red Solid On | Fault occurs in the inverter. |
| Red Flashing | Warning condition occurs in the inverter. |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3 LCD Display Icons

| Icon | Function description |
|---|---|
| AC Input Icon | Indicates the AC input. |
| PV Input Icon | Indicates the PV input. |
| Input Voltage/Frequency/PV Voltage/Charger Current/Power/Battery Voltage | Indicates input voltage, input frequency, PV voltage, charger current (if PV in charging for 10.2KW models), charger power, battery voltage. |
| Setting Programs Icon | Indicates the setting programs. |
| Warning/Fault Codes Icon | Indicates the warning and fault codes. Flashing with warning code, solid with fault code. |
| Output Voltage/Frequency/Load Percent/Load in VA/Load in Watt/Discharging Current | Indicates output voltage, output frequency, load percent, load in VA, load in Watt, and discharging current. |
| Battery Information Icon | Indicates battery information. |
| Overload Icon | Indicates overload. |
| Mains Connection Icon | Indicates unit connects to the mains. |
| PV Panel Connection Icon | Indicates unit connects to the PV panel. |
| AC Bypass Icon | Indicates load is supplied by utility power. |
| Utility Charger Circuit Icon | Indicates the utility charger circuit is working. |
| DC/AC Inverter Circuit Icon | Indicates the DC/AC inverter circuit is working. |
| Mute Alarm Icon | Indicates unit alarm is disabled. |
4.4 LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the "UP" or "DOWN" button to select setting programs, then press "ENTER" to confirm the selection or "ESC" to exit.
The LCD display information will switch by pressing "UP" or "DOWN" key. The selectable information includes input voltage, input frequency, PV voltage, charging current, charging power, battery voltage, output voltage, output frequency, load percentage, load in Watt, load in VA, DC discharging current, and main CPU Version.
4.5 Operating Mode Description
The inverter supports various operating modes to optimize power usage and battery life.
Standby Mode / Power Saving Mode
- Standby Mode: The inverter is not turned on yet, but it can charge the battery without AC output.
- Power Saving Mode: If enabled, the inverter's output will be off when the connected load is very low or not detected.
Line Mode
The unit will provide output power from the mains. It will also charge the battery in line mode.
Grid-Tie Operation
When operating in Grid-Tie mode, the grid icon will flash every 3 seconds.
Battery Mode
The unit will provide output power from the battery and solar power.
4.6 Battery Equalization Description
The equalization function is integrated into the charge controller. It reverses the buildup of negative chemical effects like stratification, where acid concentration is higher at the bottom of the battery. Equalization also helps remove sulfate crystals that may have built up on the plates. If left unchecked, this condition (sulfation) will reduce the overall capacity of the battery. Therefore, it's recommended to equalize the battery periodically.
How to Apply Equalization Function
You must enable the battery equalization function in monitoring LCD setting program 30 first. Then, you can apply this function in the device using one of the following methods:
- Setting the equalization interval in program 35.
- Activating equalization immediately in program 36.
When to Equalize
In the float stage, when the set equalization interval (battery equalization cycle) is reached, or if equalization is activated immediately, the controller will enter the Equalize stage.

Equalize Charging Time and Timeout
In the Equalize stage, the controller will supply power to charge the battery until the battery voltage reaches the battery equalization voltage. Then, constant-voltage regulation is applied to maintain the battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until the set battery equalized time is reached.
However, if the battery equalized time expires and the battery voltage does not rise to the battery equalization voltage point, the charge controller will extend the battery equalized time until the battery voltage achieves the battery equalization voltage. If the battery voltage is still lower than the battery equalization voltage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.

Mains and Lithium Battery Activation Function
- After 90 seconds of mains power connection to the inverter, the machine connects to the mains and starts to work.
- If the inverter is in lithium battery mode (item 05 is LIB or LIB-485), and the mains are connected but the battery is not, the mains activation function is automatically enabled.
5. Maintenance
5.1 Clearance and Maintenance for Anti-Dust Kit
Every inverter comes with an anti-dust kit installed from the factory. The inverter automatically detects this kit and activates an internal thermal sensor to adjust the internal temperature. This kit helps keep dust out of your inverter and increases product reliability in harsh environments.
Step 1: Loosen the screw in a counterclockwise direction on the top of the inverter.

Step 2: The dustproof case can then be removed, and the air filter foam taken out as shown below.

Step 3: Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back into the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
6. Troubleshooting
6.1 Fault Reference Code
| Fault Code | Fault Event | Icon on |
|---|---|---|
| 01 | Fan is locked when inverter is off. | 01 ERROR |
| 02 | Over temperature | 02 ERROR |
| 03 | Battery voltage is too high | 03 ERROR |
| 04 | Battery voltage is too low | 04 ERROR |
| 05 | Output short circuited or over temperature is detected by internal converter components. | 05 ERROR |
| 06 | Output voltage is too high. | 06 ERROR |
| 07 | Overload time out | 07 ERROR |
| 08 | Bus voltage is too high | 08 ERROR |
| 09 | Bus soft start failed | 09 ERROR |
| 51 | Over current or surge | 51 ERROR |
| 52 | Bus voltage is too low | 52 ERROR |
| 53 | Inverter soft start failed | 53 ERROR |
| 55 | Over DC voltage in AC output | 55 ERROR |
| 57 | Current sensor failed | 57 ERROR |
| 58 | Output voltage is too low | 58 ERROR |
| 59 | PV voltage is over limitation | 59 ERROR |
6.2 Warning Indicator
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second | 01 |
| 03 | Battery is over-charged | Beep once every second | 03 |
| 04 | Low battery | Beep once every second | 04 |
| 07 | Overload | Beep once every 0.5 second | 07 |
| 10 | Output power derating | Beep twice every 3 seconds | 10 |
| 15 | PV energy is low. | Beep twice every 3 seconds | 15 |
| E9 | Battery equalization | None | E9 |
| bP | Battery is not connected | None | bP |
6.3 Troubleshooting Table
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but the unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS/Appliance) |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. The inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. | |
| Output short circuited. | Check if wiring is connected well and remove abnormal load. | ||
| Fault code 05 | Temperature of internal converter component is over 120°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Fault code 02 | Internal temperature of inverter component is over 100°C. | Return to repair center. | |
| Buzzer beeps continuously and red LED is on. | Fault code 03 | Battery is over-charged. | Check if spec and quantity of batteries are meet requirements. |
| The battery voltage is too high. | |||
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center | |
| Fault code 08/09/53/57 | Internal components failed. | Return to repair center. | |
| Fault code 51 | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 52 | Bus voltage is too low. | ||
| Fault code 55 | Output voltage is unbalanced. |
7. Specifications
7.1 Line Mode Specifications
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | |
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Circuit Breaker | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
Output Power Derating
When the AC input voltage drops to 170V, the output power will be derated.

7.2 Inverter Mode Specifications
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Rated Output Power | 8.2KW | 10.2KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz | |
| Peak Efficiency | 93% | |
| Overload Protection | 3s@≥150% load; 5s@101%~150% load | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 48Vdc | |
| Cold Start Voltage | 46.0Vdc | |
| Low DC Warning Voltage @ load < 50% | 44.0Vdc | |
| Low DC Warning Voltage @ load ≥ 50% | 42.0Vdc | |
| Low DC Warning Return Voltage @ load < 50% | 45.0Vdc | |
| Low DC Warning Return Voltage @ load ≥ 50% | 44.0Vdc | |
| Low DC Cut-off Voltage @ load < 50% | 41.0Vdc | |
| Low DC Cut-off Voltage @ load ≥ 50% | 40.0Vdc | |
| High DC Recovery Voltage | 62Vdc | |
| High DC Cut-off Voltage | 63Vdc | |
| No Load Power Consumption | 70W | 75W |
7.3 Two Load Output Power
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Full Load | 8200W | 10200W |
| Maximum Main Load | 8200W | 10200W |
| Second Load Range | 1640W~5740W | 2040W~7140W |
| Main Load Cut Off Voltage | 52VDC | |
| Main Load Return Voltage | 54VDC | |
7.4 Charge Mode Specifications
| Utility Charging Mode | 8.2KW | 10.2KW |
|---|---|---|
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) | 140Amp | 140Amp |
| Bulk Charging Flooded Battery Voltage | 58.4 | |
| Bulk Charging AGM / Gel Battery Voltage | 56.4 | |
| Floating Charging Voltage | 54Vdc | |
7.5 MPPT Solar Charging Mode
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Max. PV Array Power PV1 Channel | 5400W | 5400W |
| Max. PV Array Power PV2 Channel | 5400W | 5400W |
| IMax.PV PV1 Channel | 18A | |
| IMax.PV PV2 Channel | 18A | |
| Nominal PV Voltage | 360Vdc | |
| PV Array MPPT Voltage Range | 90Vdc-450Vdc | |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| Max Charging Current (AC charger plus solar charger) | 160Amp | |
7.6 Grid-Tie Operation
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Nominal Output Voltage | 220/230/240 VAC | |
| Feed-in Grid Voltage Range | 195~253VAC | |
| Feed-in Grid Frequency Range | 50±1Hz/60±1Hz | |
| Nominal Output Current | 35.6A | 44.3A |
| Power Factor Range | >0.99 | |
| Maximum Conversion Efficiency (DC/AC) | 98% | |
7.7 General Specifications
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | -10°C to 50°C | |
| Storage temperature | -15°C~60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 500*390*136mm | |
| Net Weight, kg | 14.5 | 14.7 |
7.8 Approximate Back-up Time Table
| Model | Load (W) | Backup Time @ 48Vdc 100Ah (min) | Backup Time @ 48Vdc 200Ah (min) |
|---|---|---|---|
| 8.2KW/10.2KW | 500 | 613 | 1288 |
| 1000 | 268 | 613 | |
| 1500 | 158 | 402 | |
| 2000 | 111 | 271 | |
| 2500 | 90 | 215 | |
| 3200 | 76 | 182 | |
| 3500 | 65 | 141 | |
| 4000 | 50 | 112 | |
| 4500 | 44 | 100 | |
| 5000 | 40 | 90 | |
| 6200 | 36 | 80 | |
| 7200 | 32 | 70 | |
| 8200 | 28 | 60 | |
| 9200 | 24 | 50 | |
| 10200 | 20 | 40 |
Note:
- Backup time depends on the quality, age, and type of battery. Specifications of batteries may vary depending on different manufacturers.
- The final interpretation right of this product belongs to the company.
8. User Tips
- Fan Noise: During operation, especially under load, the inverter's cooling fans may produce audible noise. This is generally normal for efficient heat dissipation. Ensure proper ventilation around the unit to aid cooling and prevent excessive fan operation.
9. Warranty and Support
For technical support, warranty claims, or any inquiries regarding your PowMr Solar Inverter Charger, please contact the manufacturer directly.