PowMr POW-HVM10.2M

Contents

PowMr 48DC 10.2KW Inverter Pure Sine Wave Hybrid Inverter

Model: POW-HVM10.2M

User Manual

1. Introduction

This PowMr multi-function inverter/charger combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support in a compact size. Its comprehensive LCD display allows for user-configurable and easily accessible button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage, adapting to various applications.

1.1 Key Features

  • Pure Sine Wave Inverter
  • Configurable input voltage range for home appliances and personal computers via LCD setting
  • Configurable battery charging current based on applications via LCD setting
  • Configurable AC/Solar Charger priority via LCD setting
  • Compatible with mains voltage or generator power
  • Auto restart while AC is recovering
  • Overload, Over temperature, and Short circuit protection
  • Smart battery charger design for optimized battery performance
  • Cold start function
  • Dual AC output (Main and Second load)
  • Equipped with 3 cooling fans for efficient heat dissipation
  • Demountable insect screen for easy cleaning
  • Built-in MPPT charging control module
  • Wide PV input voltage range of 90-500V
  • Dual-channel AC output configuration of up to 10.2KW

1.2 Basic System Architecture

The inverter/charger is designed to integrate seamlessly into various power systems. A complete running system typically includes the inverter/charger, a generator or utility power source, and PV modules. Consult with your system integrator for specific architectural needs. This inverter can power a wide range of appliances in home or office environments, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners.

PowMr 10.2KW 220V On&Off Grid Inverter features
Figure 1: PowMr 10.2KW 220V On&Off Grid Inverter highlighting key features like 50/60Hz frequency, 48VDC battery voltage, MPPT 160A PV charge current, and 90-450VDC MPPT voltage range.
Hybrid Power System Diagram
Figure 2: Diagram illustrating the hybrid power system, showing connections between solar power, solar inverter, generator/utility, external battery packs, and home appliances.
Energy Cost Reduction Modes
Figure 3: Illustration of charging modes to reduce energy cost: Solar First, Solar and Utility, and Only Solar Charging.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  3. To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  4. CAUTION - Only qualified personnel can install this device with a battery.
  5. NEVER charge a frozen battery.
  6. For optimum operation of this inverter/charger, please follow the required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  7. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
  8. Please strictly follow the installation procedure when you want to disconnect AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
  9. One piece of 150A fuse is provided as over-current protection for the battery supply.
  10. GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  11. NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
  12. Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.

3. Installation

3.1 Unpacking and Inspection

Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain the following items:

  • The unit x 1
  • User manual x 1
  • Ring terminal x 1
  • MC4 terminal head x 2
Video: Unboxing and initial overview of the PowMr Solar Inverter Charger, showing included accessories like the user manual, MC4 connectors, and grounding terminal.

3.2 Product Overview

Product Overview Diagram with labeled components
Figure 4: Detailed product overview diagram with numbered components for easy identification.
  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Touch Function buttons
  6. Power on/off switch
  7. AC input
  8. Main output
  9. Second output
  10. PV1 and PV2 input
  11. WIFI communication/RS-232 port
  12. Battery communication/RS-485 port
  13. Battery input
  14. Anti dust kit

3.3 Preparation

Before connecting any lines, remove the screws under the machine and detach the bottom cover plate.

3.4 Mounting the Unit

Consider the following points when selecting a mounting location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm on both sides and above the equipment, and 50 cm below the unit.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Ensure enough space from other objects and surfaces for adequate heat dissipation and room to remove wires.

! SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing two M4 or M5 screws into the wall.

Mounting dimensions for the solar inverter
Figure 5: Mounting dimensions for the solar inverter, showing a width of 255mm, height of 500.5mm, and depth of 390.5mm.

3.5 Battery Connection

CAUTION: For safety and regulation compliance, it's recommended to install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the table below for typical amperage as required fuse or breaker size.

WARNING! All wiring must be performed by qualified personnel.

WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce the risk of injury, use the proper recommended cable as below.

Recommended Battery Cable Size
ModelWire SizeCable (mm²)Torque value (max)
8.2KW/10.2KW1 x 2AWG252 Nm

Follow these steps for battery connection:

  1. Remove 18 mm of insulation sleeve for positive and negative conductors.
  2. It is recommended to use bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the diagram below.
  4. Insert the battery wires flatly into the battery connectors of the inverter and ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify that the polarity at both the battery and the inverter/charger is correctly connected and that conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
Battery Connection Diagram
Figure 6: Diagram showing the connection of multiple 12V battery packs in series to the inverter.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure that positive (+) is connected to positive (+) and negative (-) is connected to negative (-).

3.6 AC Input/Output Connection

CAUTION!! Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and fully protected from overcurrent of AC input. The recommended spec for the AC breaker is 63A for 8.2KW/10.2KW.

CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.

WARNING! All wiring must be performed by qualified personnel.

WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce the risk of injury, use the proper recommended cable size as below.

Suggested Cable Requirement for AC Wires
ModelGaugeCable (mm²)Torque Value
8.2KW/10.2KW10 AWG61.2 Nm

Follow these steps to implement AC input/output connection:

  1. Before making AC input/output connection, ensure the DC protector or disconnector is open.
  2. Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3 mm.
  3. Insert AC input wires according to the polarities indicated on the terminal block and tighten the terminal screws. Ensure to connect the PE protective conductor (ground) first.
    • Ground (yellow-green)
    • L → LINE (brown or black)
    • N → Neutral (blue)
AC Input Wiring Diagram
Figure 7: Diagram illustrating the correct wiring for AC input connections, showing terminal block and wire colors.

WARNING: Ensure that the AC power source is disconnected before attempting to hardwire it to the unit.

  1. Then, insert AC output wires according to the polarities indicated on the terminal block and tighten the terminal screws.
    • L → LINE (brown or black)
    • N → Neutral (blue)
  2. Make sure the wires are securely connected.
AC Output Wiring Diagram
Figure 8: Diagram illustrating the correct wiring for AC output connections, showing terminal block and wire colors.

3.7 PV Connection

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce the risk of injury, use the proper recommended cable size as below.

Suggested Cable Requirement for PV Wires
ModelWire SizeCable (mm²)Torque value (max)
8.2KW/10.2KW1 x 10AWG61.2 Nm

PV Module Selection

When selecting PV modules, consider these parameters:

  1. Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
  2. Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
Inverter PV Specifications
INVERTER MODEL8.2KW/10.2KW
Max. PV Array Open Circuit Voltage500Vdc
PV Array MPPT Voltage Range90Vdc~450Vdc

Example: For a 250Wp PV module (Vmp: 30.1Vdc, Imp: 8.3A, Voc: 37.7Vdc, Isc: 8.4A, Cells: 60), recommended module configurations are:

Solar Panel Configuration (250Wp reference)
SOLAR INPUT (Min in serial: 6 pcs, max. in serial: 13 pcs)Q'ty of panelsTotal input power
6 pcs in serial6 pcs1500W
8 pcs in serial8 pcs2000W
12 pcs in serial12 pcs3000W
13 pcs in serial13 pcs3250W
12 pieces in serial and 3 sets in parallel36 pcs8200W
10 pieces in serial and 4 sets in parallel40 pcs10200W

PV Module Wire Connection

Step 1: Check the input voltage of the PV array modules. The acceptable input voltage of the inverter is 90VDC-500VDC. Ensure that the maximum current load of each PV input connector is 18A.

CAUTION: Exceeding the maximum input voltage can destroy the unit!! Check the system before wire connection.

Step 2: Disconnect the DC circuit breaker.

Step 3: Assemble the provided PV connectors with PV modules using the following steps:

Components for PV Connectors and Tools
ComponentImage
Female connector housingFemale connector housing
Female terminalFemale terminal
Male connector housingMale connector housing
Male terminalMale terminal
Crimping tool and spannerCrimping tool and spanner

Cable Preparation and Connector Assembly Process

Strip one cable 8 mm on both ends, being careful not to nick conductors.

Cable stripping diagram
Figure 9: Diagram showing the cable stripping length of 8mm.

Insert the striped cable into the female terminal and crimp it as shown in the diagrams. Then, insert the assembled cable into the female connector housing.

Female connector assembly steps
Figure 10: Step-by-step visual guide for assembling the female PV connector.

Insert the striped cable into the male terminal and crimp it as shown in the diagrams. Then, insert the assembled cable into the male connector housing.

Male connector assembly steps
Figure 11: Step-by-step visual guide for assembling the male PV connector.

Use a spanner to screw the pressure dome tightly to the female and male connectors. Check the correct polarity of the connection cable from PV modules and PV input connectors. Connect positive pole (+) of the connection cable to positive pole (+) of the PV input connector. Connect negative pole (-) of the connection cable to negative pole (-) of the PV input connector.

PV input connector polarity diagram
Figure 12: Diagram showing the correct polarity for connecting PV input cables to the inverter.

3.8 Final Assembly

After connecting all wirings, replace the bottom cover by screwing in the two screws.

3.9 Communication Connection

Wi-Fi Cloud Communication (Optional)

Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the "SMARTESS" app from the App Store or Google Play. Refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be displayed via the mobile phone app or a computer webpage.

Remote Monitoring via App
Figure 13: Remote monitoring and control via the "SMARTESS" app, showing download options for App Store and Google Play. Note: WiFi module and GPRS data need to be purchased separately.

GPRS Cloud Communication (Optional)

Use the supplied communication cable to connect to the inverter and GPRS module, then apply external power to the GPRS module. Download the app and install it from the app store. Refer to the "GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be displayed via the mobile phone app or a computer webpage.

Battery Communication

Communication between the battery and the inverter is achieved through the battery communication interface, allowing the inverter and lithium battery to exchange information (Baud rate: 9600).

Lithium Battery and Inverter Connection

If using a lithium battery, only lithium batteries matched with the BMS communication protocol are allowed.

  1. Connect the battery according to the recommended battery cable specifications.
  2. Insert the ring terminal of the battery cable into the battery connector of the inverter flatly, and ensure that the bolts are tightened with a torque of 2-3 Nm. Verify that the polarities of the battery and inverter are correctly connected, and that the ring terminal is tightened with the battery terminal.
  3. Connect one side of the RJ45 cable to the BMS communication port of the inverter.
  4. Insert the other side of the RJ45 cable into the RS485 communication port on the lithium battery.

NOTE: If you choose a lithium battery, ensure to connect the battery and inverter with a BMS communication cable, and select the battery type as "LIB-485" mode.

Communication and Setting of Lithium Battery

Connect the RJ45 communication cable between the inverter and battery. Confirm that the lithium battery BMS port's PIN corresponds with the inverter BMS communication port. The inverter BMS port PIN definition is as below:

Inverter BMS Port PIN Definition
Pin numberPort definitions
1RS485B
2RS485A
3NG
4NG
5NG
6NG
7RS485A
8RS485B
RJ45 Connector Pinout
Figure 14: Diagram of an RJ45 connector with numbered pins (1-8).

To communicate with the lithium battery BMS, press and hold the "ENTER" button for a long time, and set the battery type as "LIB-485" in program 05. Then select the matching battery protocol in Program 43.

CAUTION: When the battery type is set to "LIB-485", the setting items 12, 13, and 29 are displayed in percentage. The user cannot modify the maximum charging current. If communication fails, the inverter will cut off the output.

4. Operation

4.1 Power ON/OFF

Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

Side view of inverter showing power switch
Figure 15: Side view of the inverter, indicating the location of the power on/off switch.

4.2 Operation and Display Panel

The operation and display panel is located on the front of the inverter. It includes three indicators, four function keys, and an LCD display, showing operating status and input/output power information.

LCD Display and Function Keys
Figure 16: LCD display and function keys for operating the inverter.

LED Indicator

LED Indicator Messages
IndicatorLED StatusMessages
INV/ACGreen Solid OnOutput is powered by utility in Line mode.
Green FlashingOutput is powered by battery or PV in battery mode.
CHGGreen Solid OnBattery is fully charged.
Green FlashingBattery is charging.
FAULTRed Solid OnFault occurs in the inverter.
Red FlashingWarning condition occurs in the inverter.

Function Keys

Function Key Descriptions
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

4.3 LCD Display Icons

LCD Display Icons Overview
Figure 17: Overview of LCD display icons.
LCD Display Icons and Descriptions
IconFunction description
AC Input IconIndicates the AC input.
PV Input IconIndicates the PV input.
Input Voltage/Frequency/PV Voltage/Charger Current/Power/Battery VoltageIndicates input voltage, input frequency, PV voltage, charger current (if PV in charging for 10.2KW models), charger power, battery voltage.
Setting Programs IconIndicates the setting programs.
Warning/Fault Codes IconIndicates the warning and fault codes. Flashing with warning code, solid with fault code.
Output Voltage/Frequency/Load Percent/Load in VA/Load in Watt/Discharging CurrentIndicates output voltage, output frequency, load percent, load in VA, load in Watt, and discharging current.
Battery Information IconIndicates battery information.
Overload IconIndicates overload.
Mains Connection IconIndicates unit connects to the mains.
PV Panel Connection IconIndicates unit connects to the PV panel.
AC Bypass IconIndicates load is supplied by utility power.
Utility Charger Circuit IconIndicates the utility charger circuit is working.
DC/AC Inverter Circuit IconIndicates the DC/AC inverter circuit is working.
Mute Alarm IconIndicates unit alarm is disabled.

4.4 LCD Setting

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the "UP" or "DOWN" button to select setting programs, then press "ENTER" to confirm the selection or "ESC" to exit.

The LCD display information will switch by pressing "UP" or "DOWN" key. The selectable information includes input voltage, input frequency, PV voltage, charging current, charging power, battery voltage, output voltage, output frequency, load percentage, load in Watt, load in VA, DC discharging current, and main CPU Version.

4.5 Operating Mode Description

The inverter supports various operating modes to optimize power usage and battery life.

Standby Mode / Power Saving Mode

  • Standby Mode: The inverter is not turned on yet, but it can charge the battery without AC output.
  • Power Saving Mode: If enabled, the inverter's output will be off when the connected load is very low or not detected.

Line Mode

The unit will provide output power from the mains. It will also charge the battery in line mode.

Grid-Tie Operation

When operating in Grid-Tie mode, the grid icon will flash every 3 seconds.

Battery Mode

The unit will provide output power from the battery and solar power.

4.6 Battery Equalization Description

The equalization function is integrated into the charge controller. It reverses the buildup of negative chemical effects like stratification, where acid concentration is higher at the bottom of the battery. Equalization also helps remove sulfate crystals that may have built up on the plates. If left unchecked, this condition (sulfation) will reduce the overall capacity of the battery. Therefore, it's recommended to equalize the battery periodically.

How to Apply Equalization Function

You must enable the battery equalization function in monitoring LCD setting program 30 first. Then, you can apply this function in the device using one of the following methods:

  1. Setting the equalization interval in program 35.
  2. Activating equalization immediately in program 36.

When to Equalize

In the float stage, when the set equalization interval (battery equalization cycle) is reached, or if equalization is activated immediately, the controller will enter the Equalize stage.

Battery Equalization Graph
Figure 18: Graph illustrating the battery equalization process, showing Bulk, Absorption, Float, and Equalize stages.

Equalize Charging Time and Timeout

In the Equalize stage, the controller will supply power to charge the battery until the battery voltage reaches the battery equalization voltage. Then, constant-voltage regulation is applied to maintain the battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until the set battery equalized time is reached.

However, if the battery equalized time expires and the battery voltage does not rise to the battery equalization voltage point, the charge controller will extend the battery equalized time until the battery voltage achieves the battery equalization voltage. If the battery voltage is still lower than the battery equalization voltage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.

Battery Equalization Charging Timeout Graph
Figure 19: Graph illustrating the battery equalization charging timeout process.

Mains and Lithium Battery Activation Function

  1. After 90 seconds of mains power connection to the inverter, the machine connects to the mains and starts to work.
  2. If the inverter is in lithium battery mode (item 05 is LIB or LIB-485), and the mains are connected but the battery is not, the mains activation function is automatically enabled.

5. Maintenance

5.1 Clearance and Maintenance for Anti-Dust Kit

Every inverter comes with an anti-dust kit installed from the factory. The inverter automatically detects this kit and activates an internal thermal sensor to adjust the internal temperature. This kit helps keep dust out of your inverter and increases product reliability in harsh environments.

Step 1: Loosen the screw in a counterclockwise direction on the top of the inverter.

Loosening screw for anti-dust kit
Figure 20: Diagram showing the location of the screw to loosen for anti-dust kit access.

Step 2: The dustproof case can then be removed, and the air filter foam taken out as shown below.

Removing dustproof case and air filter foam
Figure 21: Diagram illustrating how to remove the dustproof case and air filter foam.

Step 3: Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back into the inverter.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

6. Troubleshooting

6.1 Fault Reference Code

Fault Codes and Events
Fault CodeFault EventIcon on
01Fan is locked when inverter is off.01 ERROR
02Over temperature02 ERROR
03Battery voltage is too high03 ERROR
04Battery voltage is too low04 ERROR
05Output short circuited or over temperature is detected by internal converter components.05 ERROR
06Output voltage is too high.06 ERROR
07Overload time out07 ERROR
08Bus voltage is too high08 ERROR
09Bus soft start failed09 ERROR
51Over current or surge51 ERROR
52Bus voltage is too low52 ERROR
53Inverter soft start failed53 ERROR
55Over DC voltage in AC output55 ERROR
57Current sensor failed57 ERROR
58Output voltage is too low58 ERROR
59PV voltage is over limitation59 ERROR

6.2 Warning Indicator

Warning Codes and Events
Warning CodeWarning EventAudible AlarmIcon flashing
01Fan is locked when inverter is on.Beep three times every second01
03Battery is over-chargedBeep once every second03
04Low batteryBeep once every second04
07OverloadBeep once every 0.5 second07
10Output power deratingBeep twice every 3 seconds10
15PV energy is low.Beep twice every 3 seconds15
E9Battery equalizationNoneE9
bPBattery is not connectedNonebP

6.3 Troubleshooting Table

Troubleshooting Guide
ProblemLCD/LED/BuzzerExplanation / Possible causeWhat to do
Unit shuts down automatically during startup process.LCD/LEDs and buzzer will be active for 3 seconds and then complete off.The battery voltage is too low (<1.91V/Cell)1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. The battery voltage is far too low. (<1.4V/Cell)
2. Internal fuse tripped.
1. Contact repair center for replacing the fuse.
2. Re-charge battery.
3. Replace battery.
Input voltage is displayed as 0 on the LCD and green LED is flashing.Input protector is trippedCheck if AC breaker is tripped and AC wiring is connected well.
Mains exist but the unit works in battery mode.Green LED is flashing.Insufficient quality of AC power. (Shore or Generator)1. Check if AC wires are too thin and/or too long.
2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS/Appliance)
Green LED is flashing.Set "Solar First" as the priority of output source.Change output source priority to Utility first.
When the unit is turned on, internal relay is switched on and off repeatedly.LCD display and LEDs are flashingBattery is disconnected.Check if battery wires are connected well.
Fault code 07Overload error. The inverter is overload 110% and time is up.Reduce the connected load by switching off some equipment.
Output short circuited.Check if wiring is connected well and remove abnormal load.
Fault code 05Temperature of internal converter component is over 120°C.Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.
Fault code 02Internal temperature of inverter component is over 100°C.Return to repair center.
Buzzer beeps continuously and red LED is on.Fault code 03Battery is over-charged.Check if spec and quantity of batteries are meet requirements.
The battery voltage is too high.
Fault code 01Fan faultReplace the fan.
Fault code 06/58Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac)1. Reduce the connected load.
2. Return to repair center
Fault code 08/09/53/57Internal components failed.Return to repair center.
Fault code 51Over current or surge.Restart the unit, if the error happens again, please return to repair center.
Fault code 52Bus voltage is too low.
Fault code 55Output voltage is unbalanced.

7. Specifications

7.1 Line Mode Specifications

Table 1: Line Mode Specifications
INVERTER MODEL8.2KW10.2KW
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage180Vac±7V (UPS); 100Vac±7V (Appliances)
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

Output Power Derating

When the AC input voltage drops to 170V, the output power will be derated.

Output Power Derating Graph
Figure 22: Graph showing output power derating based on input voltage.

7.2 Inverter Mode Specifications

Table 2: Inverter Mode Specifications
INVERTER MODEL8.2KW10.2KW
Rated Output Power8.2KW10.2KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50Hz
Peak Efficiency93%
Overload Protection3s@≥150% load; 5s@101%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage48Vdc
Cold Start Voltage46.0Vdc
Low DC Warning Voltage @ load < 50%44.0Vdc
Low DC Warning Voltage @ load ≥ 50%42.0Vdc
Low DC Warning Return Voltage @ load < 50%45.0Vdc
Low DC Warning Return Voltage @ load ≥ 50%44.0Vdc
Low DC Cut-off Voltage @ load < 50%41.0Vdc
Low DC Cut-off Voltage @ load ≥ 50%40.0Vdc
High DC Recovery Voltage62Vdc
High DC Cut-off Voltage63Vdc
No Load Power Consumption70W75W

7.3 Two Load Output Power

Table 3: Two Load Output Power
INVERTER MODEL8.2KW10.2KW
Full Load8200W10200W
Maximum Main Load8200W10200W
Second Load Range1640W~5740W2040W~7140W
Main Load Cut Off Voltage52VDC
Main Load Return Voltage54VDC

7.4 Charge Mode Specifications

Table 4: Charge Mode Specifications
Utility Charging Mode8.2KW10.2KW
Charging Algorithm3-Step
AC Charging Current (Max)140Amp140Amp
Bulk Charging Flooded Battery Voltage58.4
Bulk Charging AGM / Gel Battery Voltage56.4
Floating Charging Voltage54Vdc

7.5 MPPT Solar Charging Mode

Table 5: MPPT Solar Charging Mode Specifications
INVERTER MODEL8.2KW10.2KW
Max. PV Array Power PV1 Channel5400W5400W
Max. PV Array Power PV2 Channel5400W5400W
IMax.PV PV1 Channel18A
IMax.PV PV2 Channel18A
Nominal PV Voltage360Vdc
PV Array MPPT Voltage Range90Vdc-450Vdc
Max. PV Array Open Circuit Voltage500Vdc
Max Charging Current (AC charger plus solar charger)160Amp

7.6 Grid-Tie Operation

Table 6: Grid-Tie Operation Specifications
INVERTER MODEL8.2KW10.2KW
Nominal Output Voltage220/230/240 VAC
Feed-in Grid Voltage Range195~253VAC
Feed-in Grid Frequency Range50±1Hz/60±1Hz
Nominal Output Current35.6A44.3A
Power Factor Range>0.99
Maximum Conversion Efficiency (DC/AC)98%

7.7 General Specifications

Table 7: General Specifications
INVERTER MODEL8.2KW10.2KW
Safety CertificationCE
Operating Temperature Range-10°C to 50°C
Storage temperature-15°C~60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm500*390*136mm
Net Weight, kg14.514.7

7.8 Approximate Back-up Time Table

Table 8: Approximate Back-up Time Table
ModelLoad (W)Backup Time @ 48Vdc 100Ah (min)Backup Time @ 48Vdc 200Ah (min)
8.2KW/10.2KW5006131288
1000268613
1500158402
2000111271
250090215
320076182
350065141
400050112
450044100
50004090
62003680
72003270
82002860
92002450
102002040

Note:

  1. Backup time depends on the quality, age, and type of battery. Specifications of batteries may vary depending on different manufacturers.
  2. The final interpretation right of this product belongs to the company.

8. User Tips

  • Fan Noise: During operation, especially under load, the inverter's cooling fans may produce audible noise. This is generally normal for efficient heat dissipation. Ensure proper ventilation around the unit to aid cooling and prevent excessive fan operation.

9. Warranty and Support

For technical support, warranty claims, or any inquiries regarding your PowMr Solar Inverter Charger, please contact the manufacturer directly.

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD

  • Tel/Fax: +86755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

For additional information and documents, you may refer to the official user manual PDF: View User Manual (PDF)