1. Important Safety Information
WARNING
This product does not feature an explosion-proof structure and must not be used in flammable environments, such as those containing flammable gases, liquids, or explosives.
SAFETY INFORMATION
- Please use this product in accordance with the instructions in this manual.
- Do not disassemble this product by yourself.
- Pay attention to the rated voltage for use.
2. Product Overview
The EARU DPN-32 Mini Circuit Breaker (MCB) is a residual current circuit breaker (RCBO) with overcurrent protection. It is an electrical protection device that integrates the functions of a residual current device (RCD) and a circuit breaker, providing comprehensive safety for your electrical circuits.

3. Setup and Installation
3.1 Mounting
The DPN-32 Mini Circuit Breaker is designed for quick and easy installation on a standard 35mm Din Rail. Ensure the rail is securely fastened within your electrical enclosure.

3.2 Wiring
Refer to the wiring diagram below for correct connection. Always ensure power is disconnected before performing any wiring work. Connect the Neutral (N) and Live (L) wires to the designated terminals as indicated on the device and in the diagram. Securely tighten all terminal screws to prevent loose connections and potential hazards.

4. Operating Instructions
The circuit breaker functions to protect against electrical overloads and short circuits. The red operating handle controls the ON/OFF state of the circuit.
- To turn ON: Push the operating handle upwards.
- To turn OFF: Push the operating handle downwards.
- Automatic Trip: If an overload or short circuit occurs, the handle will automatically move to the OFF position, disconnecting power to the circuit. Investigate the cause of the trip before resetting the breaker.
5. Maintenance
The EARU DPN-32 Mini Circuit Breaker is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended:
- Visual Inspection: Regularly inspect the circuit breaker for any signs of physical damage, discoloration, or overheating.
- Connection Check: Periodically verify that all wiring connections are secure and that terminal screws are tight.
- Cleanliness: Ensure the area around the device is clean and free from dust or obstructions that could impede ventilation or operation.
- Functionality Test: If your electrical system allows for safe testing, occasionally test the trip mechanism by simulating a fault (only to be performed by qualified personnel).
For any concerns or complex maintenance, consult a qualified electrician.
6. Troubleshooting
If you encounter issues with your DPN-32 Mini Circuit Breaker, consider the following:
- Frequent Tripping: If the circuit breaker trips frequently, it indicates an issue within the protected circuit. This could be due to an overloaded circuit (too many devices drawing power), a short circuit (faulty wiring or appliance), or a ground fault.
- No Power: If the breaker is ON but there is no power, check the main power supply to your electrical panel.
- Resetting: After a trip, ensure the fault is cleared before attempting to reset the breaker. Push the handle fully to the OFF position, then back to ON.
If troubleshooting steps do not resolve the issue, or if you are unsure about the cause of a problem, always consult a qualified electrician.
7. Specifications
Detailed technical specifications for the EARU DPN-32 Mini Circuit Breaker are provided below. For comprehensive information, please refer to the original user manual PDF.

| Parameter | Value |
|---|---|
| Product Series | DZ30-32 |
| Product Characteristics | C type |
| Rated Voltage | AC230V |
| Electric Current Range | 6A-32A |
| Mechanical Lifespan | 20,000 cycles |
| Product Certification | CE |
| Compliant With Standards | IEC60898-1 |
| Breaking Capacity | 6000A |
| Function | Overload/short circuit protection |
| Mounting | 35mm Din Rail |
| Dimensions (H x W x D) | 72mm x 18mm x 60mm |
| Feature | Specification |
|---|---|
| Rated current In | 6A, 10A, 16A, 20A, 25A, 32A |
| Rated voltage Ue | 230/240 V |
| Insulation voltage Ui | 500 V |
| Rated frequency | 50/60 Hz |
| Rated breaking capacity | 4000/6000 A |
| Rated impulse withstand voltage (Uimp) | 4000 V |
| Dielectric test voltage (1 min) | 2 kV |
| Pollution degree | 2 |
| Energy limiting class | 3 |
| Electrical life | 8,000 cycles |
| Mechanical life | 20,000 cycles |
| Protection degree | IP20 |
| Reference temperature for thermal element | 30 °C |
| Ambient temperature | -5°C to +40°C |
| Storage temperature | -25°C to +70°C |
| Terminal connection type | Cable/Pin-type busbar |
| Terminal size for cable | 16 mm² (18-5 AWG) |
| Terminal size for busbar | 10 mm² (18-8 AWG) |
| Tightening torque | 2 N·m |

8. User Tips
Users have noted this product is reliable and conforms to expectations. For optimal performance and safety, always ensure correct installation and wiring according to the provided diagrams and specifications. Regular visual checks of the device and connections can help maintain long-term safety and functionality.
9. Warranty and Support
For warranty information, technical support, or any inquiries regarding your EARU DPN-32 Mini Circuit Breaker, please contact your seller or the manufacturer directly. A detailed user manual in PDF format is available for download from the product page for further reference.