Important Safety Precautions
⚠ Warning: To ensure safe and correct installation and operation, please read this manual carefully before installation and keep it for future reference.
- To prevent electric shock, ALWAYS turn OFF the power supply during installation or replacement.
- Do not overtighten the cover to avoid damaging the waterproof gasket.
- The surface of the product becomes extremely hot (above 70°C) during and immediately after operation. Allow it to cool completely before touching.
- Do NOT use in submerged environments or where flammable gases are present.
- Ensure all wiring is performed by a qualified electrician and complies with local electrical codes.
1. Setup and Installation
1.1 Unpacking
Carefully remove all components from the packaging. Inspect the floodlight and accessories for any signs of damage. If any damage is found, do not proceed with installation and contact your retailer.
1.2 Mounting
The floodlight features an adjustable sturdy mount for flexible installation. It can be mounted on walls, eaves, or other suitable surfaces. Ensure the mounting surface is strong enough to support the weight of the fixture.
- Position the floodlight to cover the desired area.
- Secure the mounting bracket firmly using appropriate screws and anchors (not included).
- Adjust the angle of the floodlight and the PIR sensor as needed. The sensor can rotate vertically by 180 degrees.
1.3 Wiring Instructions
Before wiring, ensure the main power supply is turned OFF at the circuit breaker.

Figure 1: Wiring Diagram
- Connect the Ground Cable (usually green/yellow) from your power supply to the ground wire of the floodlight.
- Connect the Neutral Cable (usually blue or white) from your power supply to the neutral wire of the floodlight.
- Connect the Live Cable (usually brown or black) from your power supply to the live wire of the floodlight.
- Ensure all connections are secure and properly insulated.
1.4 PIR Sensor Adjustment
The PIR motion sensor can be adjusted to optimize detection. The sensor head can be rotated vertically by 180 degrees to fine-tune its detection area. The typical detection range is 8-10 meters with a 180-degree detection angle.

Figure 2: PIR Sensor Detection Range and Angle
2. Operating Instructions
The floodlight is controlled via an infrared (IR) remote control (AAA batteries not included for remote).

Figure 3: Remote Control Functions
2.1 Remote Control Functions
- ON Button: Turns the light ON. In Constant-On Mode, it disables the sensor function.
- OFF Button: Turns the light OFF.
- AUTO Button: Activates Auto-Sensing Mode. The light will turn on when motion is detected according to other sensor settings.
- Day/Night Mode Button (Sun/Moon Icon): Activates Day/Night sensing mode. The light illuminates whenever someone passes by, regardless of daytime or nighttime.
- Night Mode Button (Moon Icon): Activates Night sensing mode. The light illuminates only at night when someone passes by.
- PIR Timer Buttons (10S, 30S, 2Min, 5Min, 10Min): Adjusts the illumination duration after motion is detected.
2.2 PIR Motion Sensor Settings
When in AUTO mode, the following PIR settings can be adjusted via the remote control:
- Ambient Illuminance Detection:
- Sun/Moon Icon: Day/night detection disabled (always active).
- Moon Icon: Activates when illuminance is below 20 LUX (night mode).
- Sensitivity Setting:
- High Sensitivity Icon: For maximum detection range.
- Low Sensitivity Icon: For reduced detection range.
- Lighting Delay Time: Select 10 seconds, 30 seconds, 2 minutes, 5 minutes, or 10 minutes for how long the light stays on after motion is no longer detected.
2.3 Manual Initialization Mode
This mode is for emergency settings or to reset the sensor. Default values: Activates at 20 LUX / Lighting duration 1 minute / High sensitivity.
Operation Steps: While the product is operating, switch the power ON and OFF twice at 0.5-2 second intervals (OFF → ON → OFF → ON) to start the manual initialization mode.
Note: All setting changes can only be made via remote control operation.
3. Maintenance
- Cleaning: To maintain optimal performance and appearance, clean the floodlight with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Inspection: Periodically check the mounting hardware and wiring connections to ensure they are secure.
- No User-Serviceable Parts: The LED chips and internal components are not user-serviceable. Do not attempt to open or repair the fixture, as this will void the warranty.
4. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on | No power; Sensor settings incorrect; Ambient light too high (in night mode) | Check power supply; Adjust sensor sensitivity/mode; Switch to Day/Night mode or adjust LUX setting. |
| Light stays on continuously | Constant-On mode activated; Sensor detecting continuous motion; Sensor faulty | Deactivate Constant-On mode; Adjust sensor placement/sensitivity; Contact support if sensor is faulty. |
| Remote control not working | Remote batteries dead/missing; Obstruction between remote and sensor; Remote faulty | Replace batteries; Ensure clear line of sight; Contact support if remote is faulty. |
| Light flickers | Unstable power supply; Loose wiring connection | Check power source stability; Inspect and secure all wiring connections (power off first). |
5. Specifications
| Feature | Specification |
|---|---|
| Product Type | PIR Motion Sensor LED Floodlight |
| Rated Power | 30W / 60W / 100W |
| Input Voltage | AC 220V, 50/60Hz |
| LED Chip Model | SMD 3030 |
| Luminous Flux | 2000-82000 lm (depending on wattage) |
| Color Temperature | 6500K (Cool White) |
| Color Rendering Index (CRI) | Ra > 85+ |
| Beam Angle | 120° |
| Protection Level | IP66 (Dust-tight & Protected against strong water jets) |
| Operating Temperature | -20°C to +60°C |
| Lifespan | Approx. 30,000 hours |
| Body Material | Aluminum Alloy, Tempered Glass |
| Control Method | IR Remote (Battery not included) |
| Cable Length | 0.9m |
| Certification | RoHS, LVD, CE |
5.1 Dimensions
| Wattage | Dimensions (L x H x D) |
|---|---|
| 30W | 150mm x 170mm x 40mm |
| 60W | 186mm x 190mm x 42mm |
| 100W | 240mm x 210mm x 48mm |

Figure 4: 30W Model Specifications

Figure 5: 60W Model Specifications

Figure 6: 100W Model Specifications
6. User Tips
- Optimal Sensor Placement: For best results, position the PIR sensor where it has an unobstructed view of the area you wish to monitor. Avoid pointing it directly at heat sources or highly reflective surfaces that could cause false triggers.
- Remote Control Line of Sight: Ensure there is a clear line of sight between the remote control and the floodlight's sensor for reliable operation.
- Test Settings: After installation, test different PIR timer and sensitivity settings to find the optimal configuration for your specific environment and needs.
7. Warranty and Support
7.1 Compliance Statement
This product complies with the following EU directives:
- 2014/35/EU Low Voltage Directive
- 2014/30/EU Electromagnetic Compatibility Directive
- 2011/65/EU RoHS 2.0 Directive
The product carries the CE mark and is approved for safe use within the European Union.
7.2 Warranty Information
For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your retailer. Keep your proof of purchase for any warranty claims.
7.3 Customer Support
If you encounter any issues not covered in this manual or require further assistance, please contact the seller or your point of purchase for support.