Gaqqee QH-VISG2

Contents

Gaqqee Handheld Signal Generator User Manual

Model: QH-VISG2-ED (With battery) / QH-VISG2-EN (Without battery)

1. Introduction

This manual provides detailed instructions for the operation, setup, and maintenance of your Gaqqee Handheld Signal Generator. This high-precision device is designed to generate both positive/negative voltage (±0-5-10V) and current (0-4-20mA) analog signals, serving as a versatile signal source and calibrator for various electrical and industrial applications. Please read this manual thoroughly before use to ensure safe and correct operation.

2. Package Contents

Please check the package carefully to ensure all items are present:

  • Calibration Instrument: 1 unit
  • Charging Cable (USB): 1 unit
  • Screwdriver: 1 unit
  • Crocodile Clips: 4 units
  • Cold-Press Terminal Connectors: 6 units
Gaqqee Handheld Signal Generator and included accessories

Figure 2.1: Contents of the package, including the signal generator, USB cable, screwdriver, alligator clips, and terminal connectors.

3. Technical Specifications

FeatureSpecification
Power Supply ModesExternal DC 15-30V, External MicroUSB-5V, Internal 3.7V Lithium Battery (1000mAh, optional)
External DC Power Consumption1W (without charging) / 4W (charging)
MicroUSB-5V Current0.2A (no charging) / 0.8A (charging)
Lithium Battery Usage Time1-5 hours (depending on output load)
Voltage Output RangeAdjustable ±10V
Voltage Output AccuracyError <0.05V after calibration, 0.01V adjustment precision
Voltage Driving Current<20mA (Max 20mA, short circuit protection)
Current Output RangeAdjustable 0-22mA
Current Output AccuracyError <0.05mA after calibration, 0.01mA adjustment precision
Current Sampling Resistance<500 Ω (load sampling resistor), 10500 ohms (internal)
Digital Display4 digits, 2 decimal places, high brightness
Encoder Knob1 rotation = 20 pulses
Working Environment0-40°C, Relative Humidity <80%
Dimensions (Shell)100mm x 60mm x 20mm (plug protruding 9mm, knob protruding 15mm)

4. Setup

4.1. Wiring Diagram

Before connecting any wires, ensure the device is powered off. Refer to the diagram and table below for correct wiring configurations for voltage, current, and passive current modes.

Wiring diagram and operation panel layout from user manual

Figure 4.1: Excerpt from the user manual showing the wiring diagram and operation panel details.

PinLabelDescription
1GNDPower supply negative (input) / Signal ground (connect to 1-GND)
224VPower supply positive (input)
3AI+Current passive mode 24V+ input
4AIOCurrent signal output
5AVOVoltage signal output

4.1.1. Voltage Signal Output

Connect pin 5 (AVO) and pin 6 (GND) for voltage signal output.

4.1.2. Common Active Mode Current Output

Our output pins 4 (AIO) and 6 (GND) correspond to PLC I+ and I- connections.

4.1.3. Current Passive Mode

Connect pin 3 (AI+) externally to 24V+. The output from pin 4 (AIO) then controls the external 24V current. The meter acts as an adjustable resistance in this mode. Direct current measurement may not be possible; it can directly replace the wiring of a passive two-wire pressure sensor.

5. Operating Instructions

5.1. Operation Panel Overview

Familiarize yourself with the controls and indicators on the device:

  1. Connection Plug (Terminal Block)
  2. Digit Tube Display (4-digit LED)
  3. Adj/Set the Knob (Rotary encoder with push-button function)
  4. USB Power Plug (MicroUSB-5V)
  5. Battery Indicator LED
  6. V Adjust Indicator LED (Voltage mode)
  7. I Adjust Indicator LED (Current mode)
  8. Battery Switch (ON/OFF)

5.2. Switching Between Voltage (V) and Current (I) Modes

To switch between Voltage (V) and Current (I) display/adjustment modes, press the "MODE" key (the knob). The corresponding indicator light (V or I) will illuminate to show the active mode. The output will continue to function in the previously set value even after switching modes, but it will not be in adjustment status until the knob is turned.

5.3. Battery Status Indicator

Turn on the battery switch to check the battery status and quantity. The LED indicator provides the following information:

Battery IndicatorCapacity
Green≥80%
Yellow≥40%
Red>0%
TwinkleCharging...
Green (not Twinkling, External power)Full

To display the battery voltage, hold the "MODE" key for 1 second. The digital tube will flash for 5 seconds showing the battery voltage.

5.4. Digital Adjustment and Parameter Setting

Important: When adjusting parameters, pushing down the knob acts as "OK" (Confirm). Clockwise rotation is "+", and counter-clockwise rotation is "-".

5.4.1. Saving Output Value

Short press "OK" (push the knob) to save the current output value. The digital tube will display "..." briefly, indicating successful save. This value will be loaded upon the next boot. When debugging, you can adjust the output randomly; as long as the knob is not pressed, the value will remain saved after rebooting.

5.4.2. Entering Setting State

Hold "OK" for 2 seconds to enter the setting state. The display will show "F001" (Parameter Number 001).

5.4.3. Changing Parameter Number

Turn the knob to change the parameter number. You may need to enter a password for F002 or F100:

  • F001 -> F002: Enter password "+--+" (turn the knob), then press the knob to enter.
  • F001 -> F100: Enter password "+-+-" (turn the knob), then press the knob to enter.

5.4.4. Modifying Parameters

Press "OK" to enter the setting of the corresponding parameter value, then turn the knob to modify the parameter.

5.4.5. Saving Parameters and Exiting

Press "OK" to save the parameter, exit the parameter setting, and display the next parameter number. (If F001 is set without entering a password, the normal operation screen will appear).

Rotate the knob directly to the last parameter number, press "OK" to complete the setting.

If no operation occurs on the parameter setting screen for over 10 seconds, it will automatically exit the setting state.

5.5. Voltage Setting Parameters

Refer to the table below for voltage setting parameters. Passwords are required for certain settings as noted above.

NumberDescriptionNoteDefault
F001Adjust Mode0:Coarse 1:Fine 2:Point Mode (Need to set F100>0)0
F002Output Mode0:±10V 1:±5V 2:0-10V 3:2-10V 4:0-5V 5:1-5V 6:0-3.3V 7:0-2.5V 8:0-1V 9:-10V-0V2
F003Display Mode0:Real Voltage 1:Percentage 0-100.0% 2:50HZ 3:15000
F004Add Or Sub Num For Knob's Pulse (Coarse)1-50, No Decimal Point Concept (1-50)×101
F005Add Or Sub Num For Knob's Pulse (Fine)1-50, No Decimal Point Concept (1-50)×11
F006-10V Calibration Value-199 - +199, Internal Reference, Please Be Careful
F0070V Calibration Value-199 - +199, Internal Reference, Please Be Careful
F008+10V Calibration Value-199 - +199, Internal Reference, Please Be Careful
F100Point Mode Num0:Point Mode Not Use 2-9:Point Num0
F101...F109Point Output ValueRange: -10V to 10V. You can set as many values as there are points.

5.6. Current Setting Parameters

Refer to the table below for current setting parameters. Passwords are required for certain settings as noted above.

NumberDescriptionNoteDefault
F001Adjust Mode0:Coarse 1:Fine 2:Point Mode (Need to set F100>0)0
F002Output Mode0:0-20mA 1:4-20mA 2:0-22mA0
F003Display Mode0:Real Voltage 1:Percentage 0-100.0% 2:50HZ0
F004Add Or Sub Num For Knob's Pulse (Coarse)1-50, No Decimal Point Concept (1-50)×101
F005Add Or Sub Num For Knob's Pulse (Fine)1-50, No Decimal Point Concept (1-50)×11
F008Calibration Value-999 - +999, Internal Reference, Please Be Careful
F100Point Mode Num0:Point Mode Not Use 2-9:Point Num0
F101...F109Point Output ValueRange: 0-22mA. You can set as many values as there are points.

6. Maintenance

To ensure the longevity and reliable performance of your signal generator, follow these maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: If your model includes a built-in lithium battery, ensure it is charged regularly, especially if stored for extended periods. A full charge typically takes more than 4 hours. Avoid over-discharging the battery.
  • Handling: Handle the device with care to prevent physical damage.

7. Troubleshooting

7.1. Current Output Issues

If the current output is not functioning as expected, consider the following:

  • Multimeter Check: The possibility of the current not outputting is very small. You can measure the voltage between 4-AIO and 6-GND with a multimeter.
  • Multimeter Malfunction: If the measured voltage is >20V, it indicates that your multimeter's current fuse might be broken or the gear setting is incorrect. There must be current for voltage to be present.
  • Troubleshooting Steps: Try changing to a different multimeter. Be aware that the current fuse inside multimeters can easily burn out.

8. User Tips

No specific user tips were available from customer reviews or Q&A for this product.

9. Frequently Asked Questions (FAQ)

No specific frequently asked questions were available for this product.

10. Warranty and Support

For warranty information and technical support, please refer to the seller's policies or contact the point of purchase. Keep your proof of purchase for any warranty claims.