1. Introduction
Thank you for purchasing the TahLiTech IPC CCTV Tester Monitor. This manual provides detailed instructions for the safe and proper use of your device. Please read it thoroughly before operation and keep it for future reference.
The 8-inch touch screen IP camera monitor is designed for maintenance and installation of various camera types, including IP, analog, 8MP TVI, 8MP CVI, and 8MP AHD cameras. It supports 4K H.264 camera testing via mainstream. Its high resolution allows for clear display of network HD and analog cameras. The combination of a touch screen and physical buttons ensures a user-friendly experience.
This tester is also an excellent tool for Ethernet network testing, capable of testing PoE power voltage, protocols, PING, and IP address searching. It includes a blue cable tracer for locating individual cables and testing LAN cable termination. Additional features include 90W PoE++ power output, HDMI IN, simultaneous IP and analog testing, an LED flashlight, DC 12V 3A, DC 24V 2A power output, and more. Its portability and comprehensive functions make it an essential tool for installers and technicians.
Video: Unboxing and overview of the TahLiTech IPC CCTV Tester Monitor and its accessories.
2. Safety Information
- The tester must be used in compliance with local electrical regulations. Avoid use in environments unsuitable for electrical devices, such as hospitals or gas stations.
- To prevent functional decline or failure, do not expose the product to sprinkles or dampness.
- Keep the exposed parts of the tester free from dust and liquids.
- Avoid violent collision and vibration during transportation and use to prevent damage to components.
- Do not leave the tester unattended while charging. If the battery becomes severely hot, immediately power off the device and disconnect it from the power source. Do not charge for more than 8 hours.
- Avoid using the tester in high humidity environments. If the tester becomes damp, power it off immediately and disconnect all connected cables.
- Do not use the tester in environments with flammable gases.
- Do not disassemble the instrument. User-serviceable components are not inside. For necessary disassembly, contact our technical department.
- Avoid using the instrument in environments with strong electromagnetic interference.
- Do not touch the tester with wet hands or watery objects.
- Clean the tester with a dry, soft cloth. If dirt is difficult to remove, a soft cloth dampened with water or neutral detergent (wrung out sufficiently) can be used.
3. Packing List
The package includes the following items:
- Tester Unit
- Adaptor DC15V 1.6A
- Network Cable Tester
- Polymer Lithium Ion Battery (11.1V DC 5200mAh)
- BNC Cable
- RS485 Cable
- Output Power Cable
- Audio Cable
- 8GB TF Card
- Safety Cord
- Tool Bag
- User Manual (PDF - View PDF)
4. Setup
4.1 Installing the Battery
The tester comes with a built-in lithium-ion polymer rechargeable battery. For safety during transportation, the battery cable inside the battery compartment may be disconnected. Before initial use, ensure the battery cables are properly connected. Under normal use, it is not necessary to disconnect the cable.
To power on/off the tester, press and hold the POWER key for more than 3 seconds.
Notice:
- Always use the original adapter and connected cable provided with the device.
- Battery charging is complete when the battery icon is full or the charge indicator turns off automatically.
- When the charge indicator turns off, the battery is approximately 90% charged. The charging time can be extended by about 1 hour, and charging within 12 hours will not damage the battery.
- If the instrument works abnormally, press and hold the POWER key for several seconds to restore default settings.
4.2 Function Interface Overview
Familiarize yourself with the tester's physical interface and controls.

Figure: Front view of the IPC CCTV Tester Monitor, showing the 8-inch screen and control buttons.
| No. | Function | Description |
|---|---|---|
| 1 | Charge Indicator | Lights red during charging, turns off when charging is complete. |
| 2 | Sleep Indicator | Lights red when the tester is in sleep mode. |
| 3 | POWER Key | Press >3 seconds to turn on/off. Short press to toggle menu display. |
| 4 | MENU Key | Accesses the menu. |
| 5 | ENTER Key | Confirms selections. |
| 6 | RETURN Key | Returns or cancels current settings. |

Figure: Top interface of the IPC CCTV Tester, showing various ports.
| No. | Function | Description |
|---|---|---|
| 7 | DC12V 3A OUT | DC power output for provisional power supply. |
| 8 | SFP | SFP optical module slot. |
| 9 | PSE IN / LAN Test | PSE power supply input interface / LAN test interface. |
| 10 | PoE++ OUT / LAN Test | PoE++ power supply output / LAN test interface. |
| 11 | HDMI IN | HDMI input port. |
| 12 | LED Lamp | Integrated LED flashlight. |

Figure: Bottom interface of the IPC CCTV Tester, showing various ports.
| No. | Function | Description |
|---|---|---|
| 13 | Video IN | Video image / AHD / TVI / CVI signal input (BNC interface). |
| 14 | Reset | Reboot machine. |
| 15 | DC 15V 1.6A IN | Charging interface. |
| 16 | DC 24V 2A OUT | DC 24V 2A power output. |
| 17 | USB 5V 2A OUT | USB 5V 2A power output, for data transmission. |
| 18 | RS485 Interface | RS485 communication for PTZ control. |
| 19 | UTP Cable Port | UTP cable tester port. |
| 20 | VGA IN | VGA input. |
| 21 | Audio IN/OUT | Audio input/output and earphone interface. |
| 22 | Audio OUT | Audio output and earphone interface. |
| 23 | TF Card Slot | Supports TF card up to 32GB (default 8GB). |
| 24 | Microphone | Built-in microphone. |
5. Operation
5.1 Instrument Connection
5.1.1 IP Camera Connection
To connect an IP camera, ensure it has an independent power supply. Connect the IP camera to the IPC tester's LAN port. A green link indicator and flickering data indicator on the tester's LAN port confirm communication. If indicators do not flicker, check if the IP camera is powered on or if the network cable is faulty.

Figure: IP camera connected to the IPC Tester's LAN port.
Note on PoE:
- If the IP camera requires PoE power, connect it to the IP tester's LAN port. The tester will supply PoE power. Tap the POE icon to toggle PoE power on/off.
- If the tester's PoE power supply is turned off via the menu, a PoE switch or power sourcing equipment (PSE) can be connected to the tester's PSE port. The tester's LAN port will then supply PoE power to the IP camera. In this configuration, the tester cannot receive data from the IP camera, but a computer connected to the PoE switch can receive data via the tester.
- Warning: PoE switch or PSE power sourcing equipment should ONLY be connected to the tester's "PSE IN" port. Connecting to other ports will damage the tester.
5.1.2 Analog Camera Connection (*Optional)
Connect the analog camera's video output to the IP tester's VIDEO IN port. The image will appear on the tester after pressing the PTZ icon.
The CCTV IP Tester's "VIDEO OUT" interface can connect to a monitor's video input or an optical video transmitter/receiver. The image will display on both the tester and the monitor.
Connect the camera or speed dome's RS485 controller cable to the tester's RS485 interface. (Ensure correct positive and negative connection).
5.1.3 HD Coaxial Camera Connection (*Optional)
CVI, TVI, and AHD cameras are classified as HD coaxial cameras. Connect the CVI camera's video output to the IP tester's "CVI, TVI, AHD IN" interface. The image will display on the tester. The tester only supports CVI, TVI, AHD input interfaces. Connect the CVI camera or speed dome's RS485 controller cable to the tester's RS485 interface.

Figure: HD Coaxial 4.0 Test setup and resolution comparison table.
5.1.4 HDMI IN (*Optional)
Connect a DVR or other device's HDMI output port to the tester's HDMI IN port. The tester will display the input image.
5.3 NET TOOL PRO
The NET TOOL PRO offers various network testing functionalities, including Cable Test, Wireless Tool, Link Tool, Full Duplex Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, and LLLDP.
5.3.1 IP Address Scan
Connect the cable to the LAN port. Set your IP address search range (Start and End IP addresses). Click "Start" to scan. You can also input an IP address in "Port Number Scan" to scan for open ports.
5.3.2 PING Test
This is a conventional network debugging tool to check if the connected IP camera or other network equipment's Ethernet port is working and if the IP address is correct.
Connect a network cable to the LAN port and click the PING icon. Set Local IP, Remote IP (e.g., camera IP), Packet count, Packet Size, Packet time, and Timeout. Press "Start". If the device is not configured or plugged in correctly, it will show "Destination host unreachable" or "100% packet loss". A 0% packet loss indicates a successful connection.
Note:
It is normal for the first data packet to be lost when the test starts.
5.3.3 Network Test (Ethernet Bandwidth Test)
This test requires two IP testers: one as a Server and one as a Client. Both must be on the same network segment.
- Start the server: Click "Start Server" to use the tester as a server. Its IP address will be displayed.
- Start send packet test: On the other IP tester (client), enter the Server's IP address. Click "Start" to send packets and test network speed.
Network bandwidth can also be tested with a computer running compatible network bandwidth testing software. The computer can act as either a Client or Server for mutual testing with the tester.
5.3.4 Port Flashing
Connect a network cable to the tester's "LAN" port and click the Port Flashing app icon. Click "Start". The IP tester sends a unique signal to make the connected LAN port of the switch flash. This helps quickly locate cables and prevents incorrect connections.
5.3.5 DHCP Server
Click the DHCP icon to open the DHCP server app. Select "Start" and make desired network changes. Click "Save" to assign dynamic IP addresses. Click "Refresh" to check the Client list.
5.3.6 Trace Route
Determines the path of IP packet access to a target. Click the icon to enter. Input the tracking IP address or domain name in "Remote Host IP". Set maximum hop count (default 30). Click "Start" to trace.
Note:
Trace route results are for reference only. For accurate tracking, use a professional Ethernet tester.
5.3.7 Link Monitor
Click the icon to open the Link Monitor app. This app checks if an IP address is occupied by other network devices, preventing conflicts. Click "Add" to enter desired IP addresses. Click "Settings" to change IP settings for different network segments. A check mark indicates an occupied IP; an "X" indicates an available IP. Click "Stop" to end testing.
Application: Add an IP camera or network device to the current network group. Ensure the new IP address is not occupied to avoid conflicts. Link monitor verifies this.
5.4 Power Output Functions
5.4.1 PoE++ Power / DC12V 3A and DC 5V 2A USB Power Output
DC 12V and DC 5V power output functions are automatically enabled when the tester is turned on. The DC 5V USB can still power external USB devices even when the tester is off.
To use PoE Power Output, click the icon and toggle "ON" or "OFF". Connect the IP camera to the LAN port before turning on PoE. If the camera supports PoE, power is delivered via pins 1, 2, 3, and 6 (or 4, 5, 7, and 8) on the LAN port. "POE++ ON" will display on screen when active.
Notes:
- This test measures voltage drawn by the PoE node. The IP tester must be between the PoE switch and the PoE node.
- The PoE switch must be connected to the PSE IN port. The powered device (e.g., IP camera) must be connected to the LAN port.
- Do not connect PoE power supply equipment to the tester's UTP/SCAN port; it will damage the tester.
- PSE transmission: When testing PoE/PSE voltage, connect PoE/PSE to the tester's PSE "IN" port and the camera to the LAN port. The tester transmits voltage and data. A computer connected to the PoE/PSE can log in to the connected camera.
5.4.2 DC 24V 2A Power Output
The "DC24V ON/0W" interface is for power output.
Application: Used for camera field demonstration and testing. Provides temporary power if no power outlet is available.
Notices:
- Do not input power into the "DC24V/2A OUTPUT" port.
- Man-made damage is not covered by warranty.
- Do not output DC24V/2A power to the DC12V/IN port; it will damage the tester.
- The IPC tester's power output is approximately 2A. If the camera's power exceeds 2A, the tester will enter protection mode. Disconnect all connections, then reconnect the tester with the power adapter to resume.
- Ensure the tester is fully charged (or >80% charged); otherwise, it may show "low power" or "not able to supply power".
5.5 Cable Test
5.5.1 RJ45 Cable TDR Test
Click the icon to enter the RJ45 cable TDR test app.
Connect LAN or telephone cable to the CCTV tester and cable tester. It displays connection status, cable type, wire sequence, and the serial number of the cable tester kit (default 255).
Single test: Tests cable status, length, and attenuation.
Repeat test: Continues to test cable status, length, and attenuation.
Status: "online" if linked; "open circuit" if not linked or open; "short circuit" if shorted.
Length: Max 180 meters. Accurate for open/short circuits; less accurate for "online" status.
Cable quality test: Green for good, Yellow for poor, Red for water-damaged. Attenuation value displayed for cables over 10 meters.
Advanced Test: Tests cable pair status, length, attenuation, reflectivity, impedance, skew, and other parameters.
- Attenuation reflectivity: 0 indicates best quality.
- Impedance: 100Ω indicates best quality (range 85-135Ω).
- Skew: 0ns indicates best quality for 1000M link. >50ns causes Bit Error Rate.
Cable sequence diagram: Displays straight-through and cross-over cable diagrams for reference.
Click "Help" to check instructions for all parameters.
5.6 Other Functions
5.6.1 15V Power Input Test
Connect a 15V power adapter to the tester's charging port. Click the "power management" icon to enter the voltage measurement app. The screen displays the current adapter input voltage and power. This measured power includes battery charging and device working power, varying with battery level and backlight brightness.
Warning:
Do not connect devices with input power over 17V to the tester's "15V IN" port; it will damage the machine.
5.6.2 Audio Record
Connect an audio device to the tester's audio input port. Click the icon to enter the Audio Recorder app. Click the red button to stop and save the recording.
5.6.3 Data Monitor
Click the icon to enter. Choose the RS485 baud rate to match the DVR or control keyboard. If the code can be read, the protocol will be shown. The RS485 port displays PTZ control codes. Check RS485 transmission status via the code on the display (RS485 communication rate must match).
Application: Checks RS485 communication states of video optical transmitters. Helps engineers analyze protocols and data.
5.6.4 Audio Player
Click the icon to enter. The audio player supports MP3 format audio files.
5.6.5 Media Player
The Media player browses video and image files, supporting MP4, H.264, MPEG4, and MKV formats. Recorded files can be played directly. It automatically displays video files from the SD card. Click to play, RETURN to exit.
To rename or delete a file, long press the filename until the options appear.
5.6.6 RTSP Player
The RTSP Player app views RTSP video streams from IP cameras. If you cannot view your camera via ONVIF or IPC Test apps, it may have an RTSP stream.
From the main menu, select the "APP Tool" folder and then select the "RTSP Player" to open the app. If the IP camera uses MJPEG, select the RTSP icon. If the IP camera uses H.264, select the "RTSP HD" icon.
- Local IP: Tester's IP address.
- RTSP Add: Manually enter the IP camera's RTSP URL or click "Search".
- IPC Username: Enter IP camera's username.
- IPC Password: Enter IP camera's password.
- After entering information, click "Enter" to view the RTSP stream.
- Note: If the tester doesn't auto-detect the RTSP stream, search online for the specific camera model's RTSP stream URL.
6. Maintenance
6.1 Hik Test Tool
This app is designed for activating and debugging Hikvision cameras. It auto-identifies inactivated Hikvision cameras and can display their images.
Tap the icon to enter.
- Activation: Select "online detection" to display inactivated cameras and click "activate". "Activation" and "Batch activation" are optional.
- Auto open ONVIF protocol: After activation, new HIK cameras can click "play", modify channel name, network info, or user info to auto-open the selected camera's ONVIF protocol.
- Play: For activated cameras, enter the correct password and click "play" to pop up "private protocol" or "speed ONVIF" options. Select the protocol to view camera images.
- Modify channel name: Click "Modify channel name" for OSD settings (time, channel name, etc.). Edit channel name, display position, and font size. Click "OK" to apply.
- Modify network information: Supports "modify" and "batch modify" camera IP address, subnet mask, and other parameters. Enter new IP and subnet mask; gateway auto-modifies. Click "OK" to save.
- Modify user information: Modify camera username and password (onvif, Dahua test tool, IPC TESTE username/password, not web username/password).
- Factory Reset: Resets camera software to factory settings. Other settings are retained.
6.2 Dahua Test Tool
This tool is for installing and debugging Dahua IP cameras. It displays images and allows modification of IP, username, and password.
Activation: Select "online detection" to display inactivated cameras and click "activate".
Play: For activated cameras, input the correct password and click "Play" to view the camera image via "private protocol" or "ONVIF". Select the corresponding protocol.
6.3 System Update
Copy the downloaded update file to the "update" directory on the SD card (create if it doesn't exist).
Click the icon to open the Update menu. Select "Local Update" for SD card updates or "Online Update" to check for internet updates. Applications needing updates will be listed.
Update online: Register first via settings-user management. Connect to the Internet for system updates.
6.4 Office App
The Quick Office app supports editable Excel, Word, and PPT formats.
6.5 LED Flashlight
Useful for installation or maintenance in low-light conditions. Click the icon to enter. Click the red button to turn the LED lamp on/off. If the red button is not pressed to turn off the lamp, it will remain on. Set a timer via the "Time Setting" button for automatic shut-off.
6.6 Browser
Click the icon to enter. Type the camera's IP address and press "Go" to access its interface.
NOTE:
Live video cannot be viewed in the web browser. Use the IP tester's live camera view apps for this. The IP camera and tester must be on the same network segment for the browser to interface. If not, click the button or "RETURN" to exit. Change the tester's network settings via the "Settings" app to match the camera's.
6.7 Notepad
Use the Notepad to record important testing results. Click "Save" to save content. It auto-records the storage date and time. Click to view saved notes. Long press a record bar to delete.
6.8 Professional WIFI Analyzer
Detects surrounding Wi-Fi signals and strength, supporting the 2.4G frequency band. Displays Wi-Fi channel, frequency, signal strength, device information, and distance in a list format.
6.9 System Settings
Click the icon to enter system settings.
- Language: Select desired language (English, Chinese, Korean, Russian, Italian, Polish, Spanish, French, Japanese, German, Turkish, etc.).
- Typewriting: Select or install typewriting options.
- Date/Time: Set the tester's date and time.
- IP setting: Manually set IP address, Subnet Mask, Default Gateway, and DNS address, or use DHCP ("Dynamic allocation"). For multiple network segments, click "Advanced" then "Add" to enter additional IP addresses.
- WLAN Net: Turn Wi-Fi on/off. Once on, click connected Wi-Fi to scan for networks. Select and long press Wi-Fi to set static IP address.
- Wi-Fi hotspot: Input SSID and password, then click "ok" to create a Wi-Fi hotspot.
- Brightness: Adjust screen brightness and sleep time.
- Volume: Set volume level.
- SD Card: Displays capacity. Can format or unmount.
- FTP server: Once connected to a network, a computer can read SD card files via FTP. Start the FTP server and input the tester's FTP address in the PC's address bar.
- Version Information: Shows app version info. Long press app icons to uninstall.
- Screen display rotation: Flips the display 180 degrees, useful for connecting LAN cables without flipping the unit.
- PTZ address scan: Toggle on/off before entering the PTZ controller app to use the PTZ Scan feature.
- Online Registration: Register after connecting to network.
- User Feedback: Send comments or suggestions.
- Lock Screen: Choose password lock, pattern lock, or "NO". Set password/pattern to enter. Modify or reset lock screen password/pattern.
- Restore the factory settings: Removes all personal files and apps.
6.10 File Explorer
Click "File" on the top bar to select internal or external storage. The icon in the upper right corner opens a menu for other operations or exit. It manages Music, Videos, Pictures, Documents, zip files, etc.
6.11 SFP Optical Module Connection
Connect an SFP optical module to the SFP slot. Use an optical fiber jumper to connect to a switch's SFP module or other equipment for network connection and detection. Supports SFP module hot-plugging.
Note:
- Do not look directly into the optical fiber hole of the SFP module to avoid laser damage (many lasers are invisible).
- Cover the SFP fiber hole with a dust cap when not in use to prevent damage.
- After successful connection, the fiber connection mark appears on the screen. Network data can be sent/received. Avoid IP conflicts by modifying the tester's IP via "System Settings" → "IP Settings".
6.12 Audio Test
Test audio input from pickup devices by connecting them to the tester with the supplied audio cable.
7. Specifications
7.1 General Specifications
| Feature | Description |
|---|---|
| Model | IP Camera Tester (E88, E89, E90 models optional) |
| Display | New 8-inch IPS touch screen |
| Network Port | 10/100/1000M auto adjust, RJ45, Dual LAN port |
| Wi-Fi | Built-in Wi-Fi, speeds 150M, connects to wireless networks, views IP cameras, Operating Frequencies: 2.4G |
| 4K H.265 Mainstream Test | New hardware decoding, 4K H.264 camera image display by mainstream testing |
| IP Discovery | Auto-scan whole network segment camera IP |
| Rapid ONVIF | Searches cameras quickly, auto logs in and displays images, activates Hikvision cameras |
| Hik Test Tool | Batch activates Hikvision cameras, displays images, modifies Channel, batch modifies IP, username, and password parameters |
| DH Test Tool | Batch activates Dahua cameras, displays images, modifies Channel, username, and password parameters |
| IP Camera Type Support | ONVIF, ONVIF PTZ, Dahua IPC-HFW2100P, Hikvision DS-2CD864-E13, Samsung SNZ-5200, Tiandy TD-NC9200S2, Kodak IPC120L, Honeywell HICC-2300T, RTSP Viewer |
| AutoHD* (Optional) | Auto-recognizes resolution and displays image, coaxial PTZ control, OSD menu, supports up to 8MP TVI/CVI/AHD and CVBS cameras |
| CVI Video Signal Test* (Optional) | 1 channel CVI input (BNC interface), resolution support 720P 25/30/50/60fps, 1080P 25/30fps, 2560x1440P 25/30fps, 2592x1944 20fps, 2960x1920 20fps, 3840 x 2160 12.5/15 fps. UTC control and call OSD menu |
| TVI Video Signal Test* (Optional) | 1 channel TVI input (BNC interface), resolution support 720P 25/30/50/60fps, 1080P 25/30/50/60fps, 2048x1536P 18/25/30fps, 2688x1520P 15fps, 2560x1440P 15/25/30fps, 2560x1944P 12.5/20fps, 3840 x 2160 12.5/15 fps. UTC control and call OSD menu |
| AHD Video Signal Test* (Optional) | 1 channel AHD input (BNC interface), resolution support 720P 25/30fps, 1080P 25/30fps, 2048x1536P 18/25/30fps, 2560x1440P 15/25/30fps, 2560x1944P 12.5/20fps, 3840 x 2160P 15 fps. UTC control and call OSD menu |
| Zoom Image | Supports Analog and IP camera image zooming & movement |
| Snapshot, Video Record and Playback | Captures images and records live video as JPG file. Media player views photos and plays back video |
| HDMI IN* (Optional) | HDMI IN, Support 4K 30FPS, 3840x2160P 30FPS, 720x480P / 720x576P / 1280x720P / 1920x1080P / 1024x768P / 1280x1024P / 1280x900P / 1440x900P. |
| VGA IN* (Optional) | 1 channel VGA Input, support resolution: 1280x1024/960/800/768/720P 60FPS, 1152x870P 60FPS, 1024x768P 60FPS, 800x600P 60FPS, 640x480P 60FPS |
| RJ45 Cable TDR Test | RJ45 cable TDR test and cable quality test, to test cable pair status, length, attenuation reflectivity, impedance, skew and other parameters. |
| 24V 2A Power Output | Output DC24V/2A power to camera |
| 12V 3A Power Output | Output DC12V/3A power to camera |
| USB 5V Power Output | 5V 2A power output |
| PoE++ Power Output | 55V PoE++ power output, Max power 90W |
| Screen Management | Change icon sequence and self-define number of icons in each page |
| Drop-down Menu | PoE power switch, IP setting, WLAN switch, HDMI IN functions etc. Screen lock: password lock screen or pattern lock |
| Audio Test | 1 channel audio signal input |
| PTZ Control | Supports RS485 control, Baud 600-115200bps, Compatible with more than 30 protocols such as PELCO-D/P, Samsung, Panasonic, Lilin, Yaan, etc |
| UTP Cable Tester | Tests UTP cable connection status and displays on screen. Reads the number on the screen |
| Data Monitor | Captures and analyzes command data from controlling device, can send hexadecimal |
| NET TOOL PRO | Cable Test, Wireless Tool, Link Tool, Full Duplex Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, LLLDP. |
| External Power Supply | DC 15V 1.6A |
| Battery | Built-in 11.1V Lithium polymer battery, 5200mAh |
| Rechargeable | Fast charging, after charging 3.5 hours, normal working time 11 hours |
| Operation Setting | Capacitive touch screen, OSD menu, select desired language: English, Chinese, Korean, Russian, Italian or Polish, etc. |
| Auto Off | 1-30 (mins) |
| Working Temperature | -10℃ to +50℃ |
| Working Humidity | 30%-90% |
| Dimension/Weight | 276mm x 163mm x 44mm / 1.14Kg |
8. Troubleshooting
- Tester not powering on: Ensure the battery cables are properly connected inside the battery compartment. Press and hold the POWER key for more than 3 seconds. If still unresponsive, try connecting the original adapter to charge.
- Abnormal operation / Tester frozen: Press and hold the POWER key for several seconds to force a reset.
- IP camera not communicating: Check if the IP camera is powered on. Verify the network cable is functioning correctly. Ensure the tester's LAN port indicators (green link, flickering data) are active.
- "Network Error" when testing IP camera: This indicates an incorrect IP address setting or the IP camera is not connected. Verify IP settings and physical connection.
- PoE power not supplied: Ensure the IP camera supports PoE. Connect the IP camera to the tester's LAN port BEFORE turning on PoE power. Check if the tester is fully charged (>80%).
- "low power" or "not able to supply power" message: The tester's battery may be low. Ensure it is fully charged (or >80% charged).
- "Destination host unreachable" or "100% packet loss" during PING test: The IP camera or network device is not configured properly or is not plugged in. Check network settings and physical connections.
- RTSP stream not detected: If the tester doesn't auto-detect the RTSP stream, search online for the specific camera model's RTSP stream URL.
- Browser not interfacing with IP camera: Ensure the IP camera and tester are on the same network segment. Adjust the tester's network settings via the "Settings" app if needed.
- Image not clear in HDMI IN mode: For analog video input, the resolution is 720*480, so the zoomed image may not be clear. For network digital video input, it supports up to 1280*960, which should be clear.
- Battery severely hot during charging: Immediately power off the device and disconnect it from the power source. Do not charge for more than 8 hours.
9. User Tips
- For quick access to frequently used apps, long-press them in the "All Applications" list to add them to the shortcut menu.
- When working in low-light conditions, utilize the built-in LED flashlight. Remember to set a timer for it if you need it to turn off automatically.
- To avoid IP conflicts in your network, use the "Link Monitor" app to check if an IP address is already in use before assigning it to a new device.
- If you need to connect LAN cables to the bottom ports of the tester, use the "Screen display rotation" feature in System Settings to flip the display 180 degrees for easier viewing without having to physically turn the unit upside down.
- Always keep the S/N label for warranty purposes.
- For any questions or problems, contact the technical department.
10. Warranty and Support
Keep the product's S/N (Serial Number) label for after-sale service within the warranty period. Products without a valid S/N label will incur charges for repair services.
If you encounter any questions or problems while using the IPC camera tester, or if any damages occur to the product, please contact our technical department for assistance.
Man-made damage is not covered under the company's warranty.