1. Important Safety Information
Please read all instructions carefully before using this product. Failure to follow these instructions may result in damage to the product or personal injury.
- Keep the device and its cord out of reach of children under 3 years old.
- Keep away from children unless supervised by an adult.
- Do not use this product for purposes other than its intended use.
- Inspect the product before each use; do not use if damaged.
- Follow installation and operation guidelines to avoid injury.
- Do not expose to water or moisture.
- Handle with care to avoid cuts or injuries, especially with the measuring jaws.
2. Product Overview
The Aramox Digital Electronic Caliper is a precision measuring tool designed for various applications, including schools, carpentry, farms, and homes. It features a high-strength carbon fiber composite material construction, making it lightweight and easy to carry. The digital display provides clear and accurate readings.
Key Features:
- High-strength carbon fiber composite material.
- Lightweight and portable design.
- Capable of measuring magnetic objects without damage.
- Clear digital display for accurate readings.
- Available in 150mm and 300mm sizes.
- Metric/Imperial conversion.
- Zero calibration function.
Components:
- External Measuring Jaws
- Internal Measuring Jaws
- Depth Measuring Blade
- Step Measuring Face
- Digital Display Screen
- ON/OFF Button
- ZERO Button
- inch/mm Conversion Button
- Thumb Roller (for fine adjustment)
- Locking Screw (to hold measurement)
3. Specifications
| Attribute | Value |
|---|---|
| Item Type | Electronic Caliper |
| Material | Carbon Fiber Composite |
| Measurement Range | 0-150mm or 0-300mm (optional) |
| Accuracy | 0.1mm |
| Operating Temperature | 27-40℃ |
| Battery | 1 x CR2032/LR44 Button Cell (Not Included) |
| Certification | CE |
| DIY Supplies | Electrical |
4. Setup
- Battery Installation: Open the battery compartment cover (usually located on the digital display unit). Insert one CR2032/LR44 button cell battery, ensuring correct polarity (+/-). Close the cover securely.
- Remove Protective Films: Before first use, carefully remove any protective films from the digital display and the measuring surfaces.
5. Operation
- Power On/Off: Press and hold the ON/OFF button for approximately 3 seconds to turn the caliper on or off.
- Zero Calibration: Close the measuring jaws completely. Press the ZERO button. The display should now read "0.00" (or "0.000" depending on units). This sets the zero reference point.
- Unit Conversion: Short press the inch/mm button to switch between metric (mm) and imperial (inch) units.
- Taking Measurements:
- **External Measurement:** Place the object between the external measuring jaws. Slide the jaws until they firmly contact the object. Read the measurement on the digital display.
- **Internal Measurement:** Insert the internal measuring jaws into the opening of the object. Expand the jaws until they firmly contact the inner surfaces. Read the measurement on the digital display.
- **Depth Measurement:** Place the end of the caliper on the top surface of the object. Extend the depth measuring blade into the hole or recess until it touches the bottom. Read the measurement on the digital display.
- **Step Measurement:** Place the step measuring face on the higher surface of the object. Extend the main beam until its end touches the lower surface. Read the measurement on the digital display.
Figure 5.1: External measurement.
Figure 5.2: Internal measurement.
Figure 5.3: Depth measurement.
Figure 5.4: Step measurement. - Locking Measurement: Use the locking screw to fix the jaws in place for repeated measurements or to transfer a measurement.
6. Maintenance
- Cleaning: Wipe the caliper with a clean, dry, soft cloth after each use. Do not use solvents or harsh chemicals.
- Storage: Turn off the device and store it in a dry place, away from direct sunlight and extreme temperatures. Keep it away from children.
- Battery Replacement: When the display becomes dim or erratic, replace the battery with a new CR2032/LR44 button cell.
- Avoid Impact: Handle the caliper with care to prevent dropping or impact, which can affect its accuracy.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is blank or dim | Low or dead battery; incorrect battery installation. | Replace battery; ensure correct polarity. |
| Inaccurate readings | Jaws not clean; not zeroed correctly; physical damage. | Clean jaws thoroughly; perform zero calibration; inspect for damage. |
| Display shows erratic numbers | Low battery; electromagnetic interference. | Replace battery; move away from strong electromagnetic fields. |
8. User Tips
No specific user tips were available from provided reviews or Q&A. However, general tips for digital calipers include:
- Always clean the measuring surfaces before taking a measurement to ensure accuracy.
- Perform a zero calibration frequently, especially after turning the caliper on or changing batteries.
- Avoid applying excessive force when closing the jaws on an object, as this can lead to inaccurate readings or damage.
- For very precise measurements, take multiple readings and average them.
9. Warranty and Support
For warranty information or technical support, please refer to the seller's policies or contact the manufacturer directly. A user manual in PDF format is also available for download: View User Manual (PDF).