1. Introduction
Thank you for choosing the BOAYAL Laser Distance Meter. This manual provides detailed instructions for the safe and effective use of your device. Please read it carefully before operation to prevent damage to the instrument or injury to yourself or others. Keep this manual for future reference.

2. Safety Instructions
To ensure safe operation and prevent potential hazards, please adhere to the following safety guidelines:
- The laser distance meter is a Class 2 laser product. Avoid looking directly into the laser beam at any time.
- Do not direct the instrument towards the sun.
- Do not use the device in inflammable or explosive environments.
- Do not attempt to disassemble or repair this instrument yourself.
- This device is not a toy; children should not use the laser distance meter.
- Avoid using this product in unstable situations where it might fall or be damaged.
- Do not store the instrument in high temperature or high humidity environments for extended periods.
- Keep the surface of the instrument clean. Wipe with a wet soft cloth; do not use corrosive liquids.
- If you encounter any quality issues or have questions, contact your local dealer or the manufacturer for assistance.
3. Product Overview
3.1. Device Components

The BOAYAL P80 Laser Distance Meter features a compact design with intuitive controls. It includes a dual-switch design for convenient operation from both the front and the side of the instrument.
3.2. Display Symbol Indication
| Symbol | Indication |
|---|---|
| Battery capacity icon | Battery capacity level |
| Area/volume icon | Indicates Area or Volume measurement mode |
| Laser Indication icon | Laser beam is active |
| Fore Basis icon | Measurement taken from the front of the device |
| Back Basis icon | Measurement taken from the rear of the device |
| MAX/MIN icon | Maximum/Minimum value in continuous measurement |
| Historical Data icon | Indicates historical data record |
| Measuring Unit (m/in/ft) | Current unit of measurement |
4. Setup
4.1. Battery Installation
The device requires 2 AAA alkaline batteries (not rechargeable). Follow these steps to install or replace batteries:
- Remove the battery compartment lid.
- Insert or change 2 AAA batteries, ensuring correct polarity as indicated inside the compartment.
- Install the battery and close the lid tightly.
Note: Do not mix old and new batteries. Replace batteries promptly when the low power indicator appears. If the instrument will not be used for a long time, remove the batteries to prevent leakage and damage.
5. Operation
5.1. Power On/Off
- To Power On: Short press the Power button/Measurement button to turn on the instrument. It will automatically enter single measurement mode, and the laser point will activate.
- To Power Off: Long press the Power button/Measurement button to shut down the device. The device also features an auto-off function after 180 seconds of inactivity.
5.2. Switching Measurement Basis (Fore/Back)
The device can measure from its front edge (Fore Basis) or its rear edge (Back Basis). This is useful for different measurement scenarios.
- Short press the Function Mode switch/Shut-down button five times. The screen will display "REF".
- Press the Function Mode switch/Shut-down button again to toggle between "Fore Basis" (measurement from the front) and "Back Basis" (measurement from the rear).

5.3. Unit Switching
The device supports measurement in meters (m), feet (ft), and inches (in).
- Short press the Function Mode switch/Shut-down button six times to enter the unit switching mode.
- Press the Function Mode switch/Shut-down button again to cycle through the available units (m, ft, in).
6. Measurement Modes

6.1. Single Measurement
This is the default mode upon power-on.
- Ensure the laser point is active (if not, short press the Power button/Measurement button).
- Aim the laser point at the target.
- Short press the Power button/Measurement button again to trigger a single measurement. The result will be displayed immediately.
6.2. Continuous Measurement (Tracking)
This mode allows for dynamic measurement, displaying real-time distance updates, as well as maximum and minimum values.
- In measurement state, long press the Power button/Measurement button to activate continuous measurement.
- The continuous measurement identifier will appear on the display. The screen will show MIN (minimum value), MAX (maximum value), and the current real-time distance.
- To exit, short press the Power button/Measurement button again.
6.3. Area Measurement
To calculate the area of a surface:
- Short press the Function Mode switch/Shut-down button once to enter area measurement mode.
- Measure the length by pressing the Power button/Measurement button.
- Measure the width by pressing the Power button/Measurement button again.
- The device will automatically calculate and display the area.
6.4. Volume Measurement
To calculate the volume of a space:
- Short press the Function Mode switch/Shut-down button twice to enter volume measurement mode.
- Measure the length, width, and height sequentially by pressing the Power button/Measurement button for each dimension.
- The device will automatically calculate and display the volume.
6.5. Pythagorean Theorem Measurement
This mode is used to calculate indirect distances (e.g., height) using the Pythagorean theorem.
- Short press the Function Mode switch/Shut-down button three times to enter Pythagorean theorem measurement mode.
- Measure the hypotenuse (c) by pressing the Power button/Measurement button.
- Measure one leg (b) by pressing the Power button/Measurement button again.
- The device will automatically calculate and display the other leg (a) or height.
7. Data Management
7.1. Data Query Function
The device can store up to 30 groups of historical measurement data.
- Short press the Function Mode switch/Shut-down button four times to enter the data query mode.
- Press the Function Mode switch/Shut-down button again to scroll through the stored data groups.

8. Maintenance
- Keep the instrument's surface clean. Wipe it with a wet soft cloth. Do not use corrosive liquids.
- If the device will not be used for an extended period, remove the batteries to prevent leakage and damage.
- Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
- Recycle waste batteries according to national or local regulations.
9. Troubleshooting
If you encounter any issues, refer to the table below for common error codes and solutions:
| Error Code | Indication | Solution |
|---|---|---|
| Err10 | Low battery | Replace the batteries. |
| Err26 | Miscalculation / Out of display range | Ensure measurements are within the device's range and follow instructions carefully. |
| Err15 | Out of range | Measure the target within the specified distance range of the device. |
| Err16 | Body shaking / Incorrect signal | Improve measurement conditions: ensure stable hand, increase target reflectivity, reduce ambient light, or adjust distance to target. |
10. Specifications
| Feature | Specification |
|---|---|
| Brand Name | INORM (BOAYAL) |
| Model Number | P80 |
| Measuring Range | 0.164 - 262 ft (0.05 - 80m) |
| Measurement Accuracy | ±1/16in (±2mm) |
| Laser Type | 620-690nm |
| Laser Hazard Level | Class 2 (<1mW) |
| Power Type | Battery-Powered |
| Battery Type | 2 x 1.5V AAA Alkaline Batteries |
| Batteries Included | Yes |
| Measured Times (Full Power) | >5000 |
| Laser Auto On/Off | 30 seconds |
| Auto On/Off (Device) | 180 seconds |
| Historical Data Record | 30 groups |
| Distance Unit | m / ft / in |
| Area Unit | m² / ft² |
| Volume Unit | m³ / ft³ |
| Operating Temperature | 0°C ~ +40°C (32°F ~ 104°F) |
| Storage Temperature | -20°C ~ +65°C (-4°F ~ 149°F) |
| Size (L x W x H) | 101 x 42 x 26 mm |
| Weight (Without battery) | Approx. 72g |
| Certification | CE, FCC, RoHS |
| Origin | Mainland China |
Note: For different measurement targets and environments, the range and accuracy may be affected. The stated accuracy is based on factory test environments meeting industry standards.
11. User Tips
- For best accuracy, ensure the measurement surface is flat and perpendicular to the laser beam.
- When measuring long distances or in bright sunlight, using a reflective target plate can improve accuracy.
- Always double-check your measurement basis (Fore or Back) before taking critical measurements.
- Utilize the continuous measurement mode for quickly finding maximum or minimum distances, such as when positioning objects.
12. Warranty and Support
12.1. Warranty Information
This product comes with a one-year warranty from the date of purchase. To claim warranty service, the warranty card and invoice must be provided.
12.2. Warranty Exclusions
The warranty does not cover:
- Unauthorized disassembly of the instrument.
- Damage caused by incorrect operation or human error.
- Damage resulting from not using original accessories.
- Repairs performed by unauthorized personnel or service centers.
- Products with altered or deleted serial numbers.
12.3. Support
For repair, replacement, or any questions regarding the instrument, please contact your local dealer or the manufacturer directly. You can also refer to the official user manual PDF for more details: User Manual (PDF).