1. Introduction

The Gaqqee 10G LD1020 Microwave Radar Induction Module is a low-power micro/motion sensing module designed around an X-band radar chip with a center frequency of 10.525GHz. This module integrates IF demodulation, signal amplification, and digital processing functions, offering independent parameter adjustment capabilities including delay settings. It boasts advantages such as no wall penetration, strong anti-interference, compact size, effective clutter suppression, high stability, and consistency.

The module's internal algorithm directly outputs detection results, eliminating the need for an external microcontroller. Its microampere-level power consumption makes it ideal for low-cost and low-power applications. Designed for embedded installation, it is resilient to environmental factors like temperature, humidity, oil smoke, and water mist, making it suitable for various lighting fixtures (e.g., bulb lamps, downlights, ceiling lamps) and low-power scenarios such as visual doorbells, cat's eyes, door locks, and low-power cameras.

2. Product Overview

The LD1020 module is a compact and efficient solution for presence and motion detection. Below are visual representations of the module and its pinout.

Front view of the LD1020 Microwave Radar Induction Module

Figure 1: Front view of the LD1020 Microwave Radar Induction Module.

Back view of the LD1020 Microwave Radar Induction Module, showing the HLK-LD1020 marking

Figure 2: Back view of the LD1020 Microwave Radar Induction Module, showing the HLK-LD1020 marking.

2.1 Pinout Diagram

Product diagram showing the VOG pinout for the LD1020 module

Figure 3: Product diagram showing the VOG pinout for the LD1020 module.

The module features a 3-pin interface (2.0/2.54mm spacing between holes) with the following connections:

  • O (IO detection output): This pin provides the detection signal.
  • G (GND): Ground connection.
  • V (5V): Power supply input (3.3V to 12V).

3. Specifications

Parameter Value
Operating Frequency 10.525GHz (10.40~10.65GHz)
Working Voltage 3.3V ~ 12.0V
Working Current 16mA (Max, VCC=3.3~12.0V)
Detection Angle Ceiling mounted / 3dB beam width / 110° ± 10°
Sensing Distance 2~8 meters (at a hanging height of 3 meters)
Output Voltage 3.3V (3.2~3.4V)
Power-on Stability Time 15S (13-17S)
Working Environment Temperature 20°C ~ +70°C
Working Environment Humidity 10~95% Rh
Blocking/Delay Time 2S/5S (Typical)
ESD Characteristics Contact discharge/air discharge 2KV (Typical)
External Dimension 15x15x2.4mm

4. Setup and Installation

4.1 Power Supply Considerations

  • Ensure to use a stable drive power supply that meets the specified output voltage, current, and ripple coefficient.
  • Unstable power supply or strong electromagnetic radiation can lead to false alarms, no perception, or continuous self-start cycles of the radar module.
  • The supporting drive power supply should be between 3.3V and 12V.
  • The driving current should not be less than 1mA (or 100mA).
  • The power ripple amplitude must be controlled within 100mV, and the power frequency fluctuation amplitude should be minimal.
  • When assembling the drive power supply and the radar module, avoid placing the drive power supply module directly beneath the radar module or its antenna surface.
  • Keep the module away from rectifier bridges, switch transformers, and other sources of power frequency interference within the drive power supply module.

4.2 Installation Environment

  • Install devices equipped with radar modules away from areas with strong vibration, such as ventilation pipes, fire pipes, drainage pipes, mechanical vibration sources, or large metal equipment, as these can affect the radar reflection wave and detection performance.
  • Avoid direct sunlight and rain to prevent damage and extend service life.
  • The device must be installed away from strong electromagnetic fields to prevent misoperation caused by electromagnetic interference.
  • Avoid installation near objects that rotate or swing, such as electric fans, swaying leaves, or clothes drying in the wind, to prevent misoperation.
  • When fixing multiple built-in radar module components, ensure a spacing of at least 0.5m between them.
  • The antenna surface of the radar module is recommended to be 3~5mm away from the product shell; otherwise, the sensing distance may be affected.
  • After installation, position the built-in radar module horizontally or vertically within its effective sensing range.
  • Avoid installing two or more built-in radar module devices face-to-face.
  • Avoid placing other interfering light sources (e.g., emergency lights, pilot lights) near devices with built-in radar modules to prevent false light sensitivity judgments, which could cause the devices to malfunction (e.g., always off or misjudged as daytime).

5. Configuration and Debugging

The LD1020 module allows for adjustment of light sensing, delay time, and blocking time to suit specific application requirements.

Configuration debugging diagram for the LD1020 module

Figure 4: Configuration debugging diagram for the LD1020 module.

  • Light Sense: Can be set and adjusted according to the actual needs of the application.
  • Delay Time: This is the duration the output state remains active after triggering. The default value is 5 seconds, but it can be adjusted as required.
  • Blocking Time: This refers to the period after the output state changes during which no new response is triggered. The default value is 2 seconds.

5.1 Adjusting Delay Time (R16)

The delay time can be adjusted by modifying the external resistance value (R16). A greater resistance value for R16 results in a longer delay time. The default setting corresponds to the first gear.

Table detailing the relationship between external resistance value (R16) and delay time for the LD1020 module

Figure 5: Relation between external configuration resistance value (R16) and delay time.

5.2 Adjusting Sensitivity (R14)

The sensitivity level, which influences the sensing distance, can be adjusted by modifying the external resistance value (R14). A smaller resistance value for R14 indicates higher sensitivity and a farther sensing distance. The default setting corresponds to the third gear (93.1K).

Table detailing the relationship between external resistance value (R14) and sensitivity level for the LD1020 module

Figure 6: Relationship between external configuration resistance value (R14) and sensitivity.

6. Operation

The LD1020 module operates by detecting micro-motion or presence within its sensing range. Upon detection, the 'O' (IO detection output) pin will provide a high-level signal (3.2-3.4V). This signal can then be used to trigger external devices or systems, such as turning on lights or activating alarms, based on the configured delay and blocking times.

For a visual demonstration of the product, please refer to the official product video:

Play video
Watch video online

Video 1: Product overview and demonstration of the LD1020 Microwave Radar Induction Module.

7. Sensing Range

The module offers a sensing distance of 2 to 8 meters when mounted at a height of 3 meters, with a detection angle of 110° ± 10° (3dB beam width) for ceiling-mounted installations.

Schematic diagram illustrating the sensing range and a radar plot for the LD1020 module

Figure 7: Schematic diagram of sensing range and radar plot.

Important Note: Different test environments or moving targets may yield varying results. Metal shielding can interfere with the radar electromagnetic wave and consequently affect the sensing distance.

8. Troubleshooting

8.1 Device Always On / Cannot Turn On/Off

If a device utilizing the built-in radar module (e.g., a lamp) remains constantly on or fails to respond to moving targets, it may be experiencing intermediate frequency interference. This interference can cause the module to continuously detect motion within its sensing range.

Troubleshooting Steps:

  1. Power Cycle: Turn off the power supply to the device.
  2. Inspect Power Supply: Verify that the power supply to the module is stable and operating normally (check output voltage, current, and ripple).
  3. Check Module Placement: Ensure there are no changes in the module's spatial distance or orientation that might affect its sensing.
  4. Environmental Scan: If the problem persists, disconnect power and carefully observe the surrounding conditions of the installation location. Identify and eliminate any environmental interference factors (e.g., strong electromagnetic fields, vibrating objects, nearby light sources).
  5. Component Replacement: If the issue remains after restarting the power supply and eliminating environmental factors, consider replacing the drive power supply or the radar module itself.

9. User Tips

No specific user tips were available from reviews or Q&A for this product at this time. Always ensure proper power supply and installation environment as detailed in sections 4 and 5 for optimal performance.

10. Package Contents

  • 1 x LD1020 Microwave Radar Induction Module

11. Warranty and Support

For warranty information and technical support, please refer to the seller's policies or contact the manufacturer directly. A detailed user manual in PDF format may be available for download from the product page or manufacturer's website. (Reference: User manual (PDF))

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.