1. Introduction
The SONGGER TA653/TA654 series (also referred to as TASI) is a wall-mounted sound level meter designed for continuous environmental noise monitoring in classrooms, offices, bars, factories, and residential areas. The device features a high-visibility LED display, A-weighted measurement in accordance with human hearing characteristics, and configurable audible and visual alarm functions. Selected models support data logging and PC communication for noise analysis and record keeping.
Figure 1: General view of the SONGGER TA653/TA654 Series Sound Level Meter.
2. Safety Information and Precautions
- Use only a regulated 5V DC power supply.
- Do not expose the device to rain, direct sunlight, or corrosive gases.
- Avoid operating outside the specified temperature and humidity ranges.
- Do not block or cover the microphone sensor during operation.
- Avoid strong mechanical shock or vibration to prevent sensor damage.
- Disconnect the power supply before cleaning or relocating the device.
- Do not disassemble the device. Risk of electric shock.
- Installation must be performed securely to prevent the unit from falling.
- Keep out of reach of children.
3. Package Contents
The package typically includes the following items:
- Sound level meter unit
- External microphone sensor with 5 m cable (for TA654A/B models)
- Instruction manual (this document)
- Two hanging hooks
- Two mounting screws
- USB data cable and software U disk (for TA654B model only)
Note: Batteries are not included due to shipping restrictions. Please prepare suitable power supply equipment for proper operation.
4. Specifications
| Feature | Specification |
|---|---|
| Power Supply | DC 5V 1A via Micro USB interface |
| Rated Voltage | 5V DC |
| Power Options | External USB power adapter |
| Measurement Range | 30 dB to 130 dB |
| Accuracy | ±1.5 dB (reference: 94 dB at 1 kHz standard sound source) |
| Frequency Response | 31.5 Hz to 8.5 kHz |
| Frequency Weighting | A-weighted |
| Sensor Type | 6 mm capacitive microphone |
| Display | 3-digit LED digital display (Full screen: 13 inches; single character: 4 inches) |
| Resolution | 0.1 dB below 100 dB; 1 dB above 100 dB |
| Response Time | Approximately 2 measurements per second |
| Refresh Rate | Twice per second |
| Alarm Mode | Audible and visual alarm |
| Alarm Output | 5V high-level signal output |
| External Sensor Cable Length | 5 meters (for TA654A/B models) |
| Operating Temperature | 0°C to 40°C |
| Operating Humidity | 10% to 80% RH |
| Storage Temperature | -10°C to 50°C |
| Storage Humidity | 10% to 80% RH |
Model Differentiation:
- **TA653A**: Features a built-in probe, 13-inch display, sound and light alarm (on/off), USB powered, non-rechargeable.
- **TA653B**: Features a built-in sensor.
- **TA654A**: No data storage, no PC communication. Utilizes an external sensor.
- **TA654B**: Data storage supported, PC communication supported (software and USB disk included). Utilizes an external sensor.
Figure 2: The large LED display, showing 13-inch full screen and 4-inch single character size.
Figure 3: High-precision microphone types: built-in sensor (TA653B) and external sensor (TA654A/B).
Figure 4: Key specifications for the TA653A model.
5. Setup
5.1. Preparation
- Ensure the device is powered via a stable 5V DC 1A Micro USB power supply.
- Install the unit on a wall using the provided hooks and screws, or place it on a stable surface.
- Position the external microphone sensor (if applicable to your model) in the target monitoring area, avoiding direct contact with vibration sources or strong airflow.
6. Operation
6.1. Basic Operation
- Connect the external sensor securely to the main unit (for TA654A/B models).
- Power on the device.
- The display will automatically begin real-time sound level monitoring.
6.2. Data Reading and Alarms
- Observe the LED display for real-time sound pressure level values in dB.
- When the measured value exceeds the preset alarm threshold, the device will trigger audible and visual alarms.
6.3. Data Logging and PC Communication (TA654B only)
- If using the TA654B model, connect the device to a PC using the supplied USB cable.
- Install the provided software from the U disk to enable data logging and analysis.
- Recorded data can be exported and analyzed via the PC software.
7. Maintenance
- Clean the housing with a soft, dry cloth. Do not use solvents or abrasive cleaners.
- Store the device in a dry and ventilated environment within the specified storage temperature range.
- If the device is not used for an extended period, disconnect the power supply.
- Periodically verify measurement accuracy using a calibrated standard sound source if available.
8. Troubleshooting
Common Issues and Solutions:
- **No Display/Power**: Ensure the 5V DC 1A Micro USB power supply is correctly connected and functional. Check the power adapter.
- **Inaccurate Readings**: Verify the microphone sensor is not blocked or covered. Ensure the device is operating within specified temperature and humidity ranges. Consider periodic calibration if accuracy is critical.
- **No Alarm Trigger**: Check if the alarm threshold is set correctly. Ensure the alarm function is enabled.
- **PC Communication Failure (TA654B)**: Ensure the USB cable is securely connected. Verify that the PC software is correctly installed and drivers are up to date.
9. User Tips
- **Optimal Placement**: For accurate readings, place the sound level meter in a central location within the monitoring area, away from direct sound sources or reflective surfaces that might skew measurements.
- **Power Stability**: Always use a stable 5V DC 1A power source to ensure consistent performance and prevent unexpected shutdowns.
- **Environmental Considerations**: Be mindful of the operating temperature and humidity to prolong the device's lifespan and maintain measurement accuracy.
10. Warning Information (EU Market Reference)
WARNING!
This device is intended for environmental noise monitoring only and must not be used for safety-critical or legally binding measurements without proper calibration and certification.
- Use only compliant CE-marked power adapters.
- Proper disposal: Follow WEEE directives for electronic waste.
Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.
11. Compliance Disclaimer
This document is provided for product instruction purposes only. It does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations.
12. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official product page or contact the seller directly. Please have your product model and purchase date available when seeking support.
A detailed user manual in PDF format is available for download: View User Manual (PDF)