TNCE Adjustable Over Voltage Under Voltage Protection Device (40A/63A)

Contents

TNCE Din Rail Adjustable Over Voltage Under Voltage Protection Device User Manual

Models: 40A, 63A

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your TNCE Din Rail Adjustable Over Voltage Under Voltage Protection Device. This device is designed to safeguard electrical circuits and equipment from damage caused by voltage fluctuations and overcurrent conditions, featuring automatic reset capabilities and a clear digital display for real-time monitoring.

TNCE Adjustable Voltage Current Protector showing Overvoltage, Undervoltage, Overcurrent Protection, and Automatic Reset features, with a digital display for voltage (220V) and current (63.0A).

Image: TNCE Adjustable Voltage Current Protector showing Overvoltage, Undervoltage, Overcurrent Protection, and Automatic Reset features, with a digital display for voltage (220V) and current (63.0A).

2. Important Safety Warnings

▲ WARNING

This product involves high voltage. Improper use may cause electric shock, fire, equipment damage, serious injury, or death.

Professional Installation & Operation:

  • Installation, wiring, and commissioning MUST be performed ONLY by a qualified electrician in compliance with all local electrical codes and regulations.
  • End-users are STRICTLY PROHIBITED from opening the distribution board or performing any physical operations. User operation should be limited to remote monitoring and control via the device's interface.

Electrical Safety:

  • DO NOT OVERLOAD! The total current of connected loads must NOT exceed the device's rated current (40A or 63A).
  • After a trip, the root cause (e.g., short circuit, overload) MUST be identified and completely eliminated by an electrician before any reset attempt. NEVER attempt to close the switch repeatedly without knowing the fault cause.
  • The auto-reclosing function is designed for transient faults only. For permanent line faults, the device will lock out and alarm after consecutive failed reclosing attempts, and MUST be inspected on-site by an electrician.

Usage Environment:

  • For INDOOR installation in a standard distribution board/cabinet only.
  • The environment must be dry, well-ventilated, and free of corrosive gases or flammable materials.

3. Technical Specifications

AttributeSpecification
TypeMini Circuit Breaker / Protector Relay
Rated Voltage220V (AC 230V as per some documentation)
Rated Current40A / 63A (selectable model)
Voltage Display Range80-300V
Current Display Range1-40A / 1-60A (depending on model)
Mounting35mm DIN Rail Mount
Operating Temperature-5°C ~ +40°C
OriginMainland China
CertificationCE, RoHS

Dimensions:

Product dimensions of the TNCE Adjustable Voltage Current Protector, indicating measurements such as 90mm (3.54in) height, 46mm (1.81in) depth, and 37.0mm (1.46in) width.

Image: Product dimensions of the TNCE Adjustable Voltage Current Protector.

  • Height: 90mm (3.54in)
  • Depth: 46mm (1.81in)
  • Width: 37.0mm (1.46in)
  • Overall Depth (including DIN rail clip): 65.5mm (2.58in)
  • Device Width: 49mm (1.93in)

4. Product Overview & Features

The TNCE Adjustable Over Voltage Under Voltage Protection Device offers comprehensive protection and monitoring for your electrical system.

Key Features:

  • Overvoltage Protection: Automatically disconnects power when voltage exceeds a set limit.
  • Undervoltage Protection: Automatically disconnects power when voltage drops below a set limit.
  • Overcurrent Protection: Automatically disconnects power when current exceeds a set limit.
  • Automatic Reset: Restores power automatically after transient faults clear and within configured delay times.
  • Dual Digital Display: Shows real-time operating voltage and current simultaneously.
  • Adjustable Parameters: Allows users to set specific over/under voltage and overcurrent thresholds, as well as recovery and power-on delay times.
Close-up of the voltage and current display on the protector, showing a voltage range of 80-300V and a current range of 1-40/60A.

Image: Close-up of the Voltage and Current Display.

Product Interface Overview:

Product interface overview, labeling incoming (IN) and outlet (OUT) terminals, overvoltage, undervoltage, overcurrent, and power indicators, operating voltage and current displays, and setup and confirm buttons.

Image: Product Interface Overview.

  • IN Terminals (N, L): Incoming Line connections.
  • OUT Terminals (N, L): Outlet Terminal connections.
  • Digital Displays: Top display for Operating Voltage, bottom display for Operating Current.
  • Indicators: Overvoltage Indicator (>V), Undervoltage Indicator (A), Power Indicator (POWER).
  • Buttons: Setup Button (M), Up/Down Adjustment Buttons (▲, ▼), Confirm Button (⏻).

5. Installation Guide (For Qualified Electrician Only)

WARNING: The upstream main power MUST be switched OFF and verified de-energized before any work!

5.1. Power Off:

Disconnect the main switch of the distribution board, hang a warning sign, and verify the installation point is de-energized using appropriate testing equipment.

5.2. Mounting:

Mount the device vertically onto a standard 35mm DIN rail inside the distribution board and lock it securely.

5.3. Wiring:

The electrician must correctly connect the power input and load output wires strictly according to the terminal markings (IN for input, OUT for output, N for Neutral, L for Live) and local electrical codes and regulations.

Wiring diagram for the TNCE Adjustable Voltage Current Protector, showing 'Upper Line In, Lower Line Out' connection to main circuit breakers (L and N inputs and outputs).

Image: Product Wiring Method - Upper Line In, Lower Line Out.

5.4. Inspection:

After wiring, the electrician must double-check all connections for correctness and tightness, clear any debris, and ensure proper insulation before restoring power.

6. Operation & Settings

6.1. Initial Power-Up:

Once installed and power is restored, the device's digital display will light up, showing the current voltage and current readings. The 'POWER' indicator will be lit.

6.2. Reading the Display:

The top display shows the real-time operating voltage (V), and the bottom display shows the real-time operating current (A).

6.3. Adjusting Parameters:

The device offers 19 configuration methods for various settings, including overvoltage, undervoltage, overcurrent thresholds, recovery times, and power-on delays. Refer to the device's on-screen menu and the specific parameter codes (e.g., P-1 for Power-on delay) for detailed adjustments.

Image illustrating the multiple setting functions of the protector, highlighting 19 configuration methods and a 'P-1: Power-on delay' setting.

Image: Multiple Setting Functions, including 'P-1: Power-on delay'.

  1. Press the 'M' (Setup) button to enter the setting mode.
  2. Use the '▲' and '▼' buttons to navigate through the parameter codes (P-1, P-2, etc.).
  3. Press the '⏻' (Confirm) button to select a parameter.
  4. Use '▲' and '▼' buttons to adjust the value.
  5. Press '⏻' again to save the setting and exit the parameter adjustment.
  6. Press 'M' to exit the setting mode.

7. Troubleshooting

SymptomPossible CauseSolution (For Electrician)
Auto-Reclosing Unsuccessful1. Permanent fault on the line.
2. Function disabled.
3. Device fault.
DO NOT force reset! Electrician MUST locate and repair the line fault. Check device settings to ensure auto-reclosing is enabled. If the fault persists, contact technical support.
Device not powering on / No display1. No input power.
2. Incorrect wiring.
3. Device fault.
1. Check power supply to the IN terminals.
2. Verify wiring according to the diagram.
3. If power is present and wiring is correct, the device may be faulty; contact technical support.
Frequent tripping1. Load exceeding set limits.
2. Unstable power supply.
3. Incorrect sensitivity settings.
1. Check connected load and ensure it's within device and set limits.
2. Monitor power supply stability.
3. Review and adjust over/under voltage and overcurrent settings.

8. User Tips

  • Always ensure the device is installed by a qualified electrician to guarantee safety and proper functionality.
  • Regularly monitor the voltage and current readings on the display to understand your electrical system's behavior.
  • Familiarize yourself with the setting parameters to customize protection levels according to your specific needs.
  • In case of persistent issues or unexpected behavior, always consult a professional electrician.

9. Compliance & Certifications

This product is designed to comply with the following harmonized standards and technical specifications:

Standard TypeStandard Number & Date
Electrical SafetyEN IEC 62368-1:2020+A11:2020
Human Exposure (EMF)EN IEC 62311:2020
EMC & RadioETSI EN 301 489-1 V2.2.3
ETSI EN 301 489-17 V3.2.4
ETSI EN 300 328 V2.2.2
Substance RestrictionsIEC 62321-1:2013, IEC 62321-2:2021,
IEC 62321-3-1:2013, IEC 62321-5:2013
Electricity Metering EquipmentEN 50470-1:2006+A1:2018

The device carries the CE and RoHS certifications, indicating compliance with European safety, health, and environmental protection standards.

10. Warranty & Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

A user manual in PDF format may be available for download. Please refer to the following link for additional documentation: User manual (PDF)

© 2024 TNCE. All rights reserved.