1. Product Overview
This feyree EV Charger is designed for electric vehicle AC charging, offering a simple design with multiple specifications including Type2, Type1, GB/T, and TS-NACS. It supports both swipe card and plug-and-play charging methods, along with multiple safety protection functions. Its robust dustproof and waterproof design ensures safe operation outdoors.
Key Features:
- Dynamic Load Balancing (DLB): Automatically adjusts charging current to prevent electrical system overload by monitoring home appliance power usage.
- High-Quality Material: Features a 99.95% pure copper wire core cable and 5μ silver-plated charging pin for superior conductivity and corrosion resistance. TUV certified cable ensures safety and durability.
- Smart App Control & Real-Time Monitor: Control the wallbox via the Tuya app (available on App Store and Google Play for Android and iOS) to monitor charging, set start/stop times, determine power/current, and review charging data.
- 8 Intelligent Safety Protections: Includes lightning-proof, leakage, overvoltage, overheat, IP65 waterproof rating, UL94V-0 flame resistance, and overcurrent protection.
- Intelligent Temperature Control System: Supports use in various weather conditions with smart temperature protection for charging safety.
- 2.8-inch Color LCD Screen: High-definition display shows real-time charging information like current, voltage, and power.
- Safety Type B Leakage Protection: Equipped with Type B (AC30mA + DC6mA) leakage protection for enhanced safety.
- Schedule Charging Time: Smart appointment scheduling allows charging during off-peak hours to save costs.
- Easy Installation: Practical and intuitive design suitable for indoor and outdoor use (IP65 certified), compatible with most household electrical installations and EVs with Type 2 plugs.
2. Safety Instructions
Please read and understand all safety instructions before operating the feyree EV Charger.
- Grounding: The charging station must be properly grounded (PE).
- Environment: Do not place flammable, explosive, or combustible materials, chemicals, vapors, or other hazardous materials near the charging station.
- Plug Maintenance: Keep the charging plug head clean and dry. If dirty, wipe with a clean, dry cloth. Do not touch the charging plug core by hand when it is charged.
- Damage: Do not use the charging station if the charging plug or cable is defective, cracked, worn, broken, or exposed.
- Modification: Do not attempt to disassemble, repair, or modify the charging station. Improper operation can cause damage, water leakage, electrical leakage, short circuits, or electric shock. Contact qualified personnel for repairs.
- Thunderstorms: Use with caution during thunderstorms.
- Children: Children should not approach or use the charging station during charging to avoid electric shock.
- Vehicle Movement: Do not drive the car while it is charging. Only start charging when the car is stationary. For hybrid cars, turn off the engine before charging.
- Emergency Stop: In case of emergency, immediately press the emergency stop button to cut off all input and output power.
- Prohibited Use: Do not use the charging post if the shell is damaged, the charging cable is damaged (cracked, frayed, broken), if it has been struck by lightning, or if there are accidents/fires nearby, or if water is present in the charging station. Contact the manufacturer immediately in such cases.
- Extension Cables: If the charging cable is not long enough, an extension cable needs to be installed by a qualified electrician.
3. Specifications
The feyree EV Charger is available in different configurations. Please refer to the table below for detailed specifications.
3.1. Type 2 IEC 62196-2 Parameters
| Feature | 7.6kW (1 Phase) | 11kW (3 Phase) | 22kW (3 Phase) |
|---|---|---|---|
| Load Balancing | Optional | Optional | Optional |
| APP Control | Optional | Optional | Optional |
| RFID Card | Optional | Optional | Optional |
| Type A RCD | Yes | Yes | Yes |
| Type B RCD | Optional | Optional | Optional |
| Leakage Protection Value | TypeA: AC 30mA; TypeB: AC 30mA + DC 6mA | ||
| Power Supply System | Single Phase | Three Phase | Three Phase |
| Rated Voltage | 85V-264V | 380V ± 20% | 380V ± 20% |
| Rated Current | 8-10-13-16-20-25-32A | 8-10-13-16A | 8-10-13-16-20-25-32A |
| Input Frequency | 50Hz/60Hz | ||
| Charger Plug | IP65 | ||
| Charger Box | IP66 | ||
| Operating Temperature | -35°C ~ +55°C | ||
| Storage Temperature | -40°C ~ +80°C | ||
| Standby Power | <3W | ||
| Working Humidity | 5%~95% non-condensation | ||
| Cable Specification | 3G 6mm² + 1*0.5mm² | 5G 2.5mm² + 1*0.5mm² | 5G 6mm² + 1*0.5mm² |
3.2. Control Box Functions
- Leakage protection (restart recovery)
- Overvoltage and undervoltage protection (self-test recovery)
- Lightning protection
- Overcurrent protection
- Overheat protection
- Grounding protection
- RFID card function (can be set according to user needs)
- Appointment Time
- WIFI
3.3. Product Performance
- Charging plug according to IEC 62196-2 standard
- Charging control box in accordance with IEC61851 control principle
- Insulation resistance: >1000MΩ
- Terminal temperature rise: <50K
- Mechanical life: Charging Plug plugging and unplugging times (Non-operating state) >10000 times
- External impact: Charging Station Plug can withstand the 1-meter drop and 2 tons of vehicle crushing
- Altitude: ≤2000m
- With emergency stop function
4. Installation Instructions
Proper installation is crucial for the safe and efficient operation of your EV charger. Please follow these steps carefully.
4.1. Pre-use Preparation
- Ensure no open flames are around the equipment and the surrounding space is not blocked.
- Verify that the equipment casing and charging cable are not damaged.
- Ensure proper maintenance of equipment.
- Make sure the emergency stop button is popped up. If pressed, rotate it clockwise to reset.
4.2. Mounting the Charger
- Step 1: Use an electric drill to make holes for the metal back mounting bracket. Refer to the provided photo for recommended installation height. Insert expansion tubes into the holes and use long screws to fix the metal mounting bracket to the wall.
- Step 2: After fixing the metal bracket, hang the charger on the bracket. Use screws to secure the metal bracket underneath the charger to the wall.
- Step 3: Install the charging plug holder in the position shown in the pictures.
- Step 4: Connect the power supply and ensure the charger functions correctly.
4.3. Wiring Connection Methods
The feyree EV Charger supports both single-phase and three-phase wiring configurations. Ensure all connections are made by a qualified electrician.
Single Phase Wiring:
The CT current transformer is connected to the main line L1 circuit of the household, directly connected to the charging station, and feeds back the CT signal to the charging station.
Three Phase Wiring:
Three CT current transformers are connected to the household main line L1/L2/L3 circuit and to the RS485 communication control box. The communication control box is connected to the charging station through Ethernet RJ45 wiring for RS485 communication, providing real-time total working current feedback to the charging station.
5. Operating Instructions
5.1. Charging Steps
- Standby Status: When in standby mode, the interface shows the device is ready for charging. The indicator light on the wallbox is green and always on.
- Waiting for Card Swipe Status: Park your car, take the charging plug from the holder, set the charging current, then insert the plug into the EV connector. Ensure the plug is securely inserted. The device will enter identity verification status.
- Start-up Device: Use an RFID card to authorize the charging station.
- Start Charging: The device will begin charging, and the interface will display charging status and parameters. The indicator light (for Wi-Fi function only) will be green and breathing.
- Stop Charging: The charging station will automatically stop when the vehicle is fully charged. In an emergency, press the Emergency Stop button. An RFID card can also be used to stop charging.
5.2. Key Operation Instructions
- Set Charging Current: When the charging plug is not inserted, press button 'A' on the panel to adjust the charging current. The current setting range depends on the charger's max power (e.g., 7.6kW and 22kW versions can set 8-32A, 11kW version can set 8-16A).
- Set Delay Time Charging: When the charging plug is not inserted, touch the 'D' button to set the delayed charging time (0-15 hours). The charger will start after the set delay.
- Set Timing Charging: Touch the 'T' button to modify the timing charging (0-15 hours). The charger will charge for the set duration and then stop.
- Access Menu Page: Long press the 'A' button for 5 seconds to enter the settings page. If RFID function is enabled, tap an RFID card after the long press.
- Menu Navigation: Use the panel icons for upward, downward, enter, and back to navigate and adjust menu parameters. Note: The charging plan and load balance settings cannot be accessed while the charging plug is inserted.
5.3. Dynamic Load Balancing (DLB)
The DLB function intelligently manages the charging station's power output based on your household's total circuit load, preventing overloads and ensuring electrical safety. It's an adaptive power adjustment system, not a simple on/off switch.
Working Principle:
- Total Current: Sets the maximum current capacity per phase for your home circuit (8A to 99A). Exceeding this value will trip the circuit breaker.
- CT Sensor: A monitoring device installed on the home main circuit collects real-time total current data from all household electrical devices, including the charger.
- Charging Current: The real-time current used by the charger.
- Home Appliance: Total load of home appliances in the maximum load circuit, excluding the charging station.
- Standby Current: Calculated as "Total Current" - "CT Sensor".
Note: For the 3-phase version, select the max current from 3 CT sensors.
DLB Scenarios (Single Phase Example):
- Scenario 1 (Active): If Charging Current + Standby Current ≥ 8A, but less than the set current, the charger uses the standby current.
- Scenario 2 (Inactive): If Charging Current + Standby Current ≥ set current, full power charging occurs.
- Scenario 3 (Active, Stop Charging): If Charging Current + Standby Current < 8A, the charger stops charging.
DLB Scenarios (Three Phase Example):
5.4. App Usage
The feyree EV Charger can be controlled via the Smart Life or Tuya Smart app. The device needs to have WiFi and Bluetooth functionality.
- Download the "Smart Life" or "Tuya Smart" app from your phone's app store.
- Open the app, enable your phone's WiFi and Bluetooth.
- Select "Add Device" and follow the in-app instructions to complete the pairing process.
The app allows you to adjust current, set delay time, and set charging time.
The app can also be used without WiFi by connecting your phone to the charger via hotspot and Bluetooth within 10 meters (requires your SIM card to have a signal).
You can also set weekly charging plans to avoid electricity consumption peaks and save money.
The charger supports 4 charging modes: WiFi (through mobile app), Bluetooth (through mobile app), RFID Scan, and Plug & Charge.
5.5. RFID Card Management
You can add or delete RFID cards for charging authorization.
- Long press for 5 seconds to enter the settings page.
- Tap an RFID card to enter.
- Navigate to "Rfid Manage" in the menu.
- Select "Add Card" to add a new blank RFID card or "Delete Card" to remove an existing one.
6. Maintenance
To ensure the longevity and optimal performance of your feyree EV Charger, follow these maintenance guidelines:
- Regularly inspect the charging cable and plug for any signs of wear, damage, or exposure. Replace immediately if any damage is found.
- Keep the charging plug head clean and dry. Wipe with a clean, dry cloth if dirty.
- Ensure the charger's casing is free from damage.
- Do not expose the charger to extreme temperatures beyond its operating range (-35°C to +55°C).
- The charger is designed for indoor/outdoor use with IP65/IP66 protection, but avoid direct prolonged exposure to harsh weather conditions if possible.
- Do not attempt to open or repair the unit yourself. Refer to qualified service personnel for any issues.
7. Troubleshooting
If you encounter any issues with your feyree EV Charger, refer to the table below for common problems and recommended solutions.
| Fault Name | Reason for Failure | Recommendations |
|---|---|---|
| Over Voltage | AC input voltage is too high |
|
| Under Voltage | AC input voltage is too low |
|
| Over Current | AC input current is too high |
|
| Over TEMP | Charger internal temperature > 85°C |
|
| Elec Leakage | Leakage is greater than specified values (TypeA: AC20mA/AC30mA; TypeB: AC 30mA+DC 6mA) |
|
| Leakage Self Check | Sensor for detecting leakage is abnormal |
|
| PE Fault | Poor grounding or incorrect wiring |
|
| Err:CP | Charging plug CC/CP connection abnormality |
|
| Err:Reset | Reset button is pressed |
|
| Err:LoadBalance | Standby current + charging current < 8A |
|
8. User Tips
- Installation: Users have reported easy installation and perfect operation once set up.
- DLB Precision: Some users note that the detection of absorption (DLB) may not be very precise. Monitor your household load if this is a concern.
- Documentation: The provided instructions may be unclear or incomplete for some users. For detailed information, refer to the official PDF user manual if available.
- Solar Surplus Charging: The manual does not explicitly mention support for solar surplus charging. Please consult the manufacturer or a qualified electrician for compatibility with solar setups.
9. Warranty and Support
9.1. Two-Year Warranty
feyree offers a two-year warranty to customers who purchase original feyree products.
9.2. Lifetime Technical Support
In case of any product-related issues, please reach out to feyree customer service. Provide pictures and videos for further assistance.
E-mail: tina@feyree.com
9.3. Exclusions
The warranty does not cover:
- Any product damage resulting from failure to follow the recommended guidelines.
- Damage caused by unauthorized disassembly of the machine or seeking maintenance from a non-designated service center.
- Products not purchased as original feyree products.
- Any modifications or do-it-yourself alterations carried out without guidance from a licensed electrician.
10. FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and uses can radiate radio frequency energy, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user's authority to operate the equipment.
The device has been evaluated to meet general RF exposure requirements. To maintain compliance with FCC's RF exposure guidelines, the distance must be at least 20cm between the radiator and your body, and fully supported by the operating and installation configurations of the transmitter and its antennas.