This manual provides detailed instructions for the installation, operation, and maintenance of your LONG AC-7036-T Hidden Touch Sensor Switch. This innovative switch allows for invisible control of lights, fans, and other appliances by detecting touch through various non-metallic materials.
Important Safety Information
WARNING: HIGH VOLTAGE HAZARD. IMPROPER INSTALLATION OR HANDLING CAN RESULT IN SERIOUS INJURY OR DEATH.
- The sensor cable and internal circuit board carry high voltage. Ensure the power supply is completely disconnected before any installation, removal, or maintenance.
- Do not disassemble the housing of the sensor control switch. Direct contact with the internal circuit board is dangerous due to high voltage.
- Do not use this switch on metal or mirror surfaces, as these materials can block the sensor's signal and prevent proper operation.
- Always secure the switch firmly in its intended location before connecting to power.
- Installation should only be performed by a qualified electrician or a person with adequate knowledge of electrical systems.
Specifications
| Feature | Detail |
|---|---|
| Product Name | Penetrating touch sensor |
| Product Model | AC-7036-T (F47, F100) |
| Input Voltage | AC100-240V, 50/60Hz |
| Output Voltage | AC100-240V |
| Max Power | 400 Watt |
| Penetration Thickness (F47) | ≤3CM |
| Penetration Thickness (F100) | ≤5CM |
| Penetrating Material | Wood boards, Glass, Acrylic sheets |
| Switch Type | Touch On/Off Switch |
| Material | Plastic |
| Is Smart Device | No |
| Certification | RoHS, EMC, CE |
| Warranty | 1 year |
Package Contents
The package typically includes:
- 1x AC Sensor Control Switch (Model AC-7036-T)
- 1x Touch Sensor Pad (F47 or F100 variant)
- Double-sided adhesive tape for mounting
- Instruction leaflet (refer to this manual for comprehensive details)
Setup and Installation
Follow these steps carefully to install your hidden touch sensor switch. Ensure power is disconnected before starting.
1. Mounting the Sensor Pad
- Identify the desired location for the touch sensor on the surface (e.g., cabinet door, desk).
- The white part on the back of the sensor pad is double-sided tape. Peel off the protective film from the double-sided tape.
- Stick the sensor pad firmly onto the back of the chosen non-metallic surface (wood, glass, acrylic). Ensure it is securely attached.
2. Wiring Connection
Refer to the connection diagram below for proper wiring. It is crucial to ensure all connections are correct and secure before applying power.
- Input (AC100-240V): Connect the Live (L) and Neutral (N) wires from your power source to the 'L In' and 'N In' terminals on the control switch.
- Output (AC100-240V): Connect the Live (L) and Neutral (N) wires of your appliance (e.g., lamp, fan) to the 'L Out' and 'N Out' terminals on the control switch.
- For 12V/24V lamps, a constant voltage adapter (DC12V-24V) is required between the switch output and the lamp. The output voltage of the switch must match the input voltage of the load.
- Ensure the total power of connected loads does not exceed 400 Watts.
3. Power On
After ensuring all connections are secure and the sensor is mounted, you may connect the power supply. The switch is now ready for operation.
Video: Demonstration of sensor installation and operation for both MODE A and MODE B.
Operating Modes
The AC-7036-T switch supports two operating modes:
MODE A: Momentary Touch
In MODE A, the connected appliance turns ON when you touch the sensor area and turns OFF immediately when you release your touch. This mode is suitable for applications where you need temporary activation.
MODE B: Toggle Touch
In MODE B, the connected appliance turns ON with the first touch to the sensor area and remains ON. A subsequent touch will turn the appliance OFF. This mode functions as a standard toggle switch.
Maintenance
- Keep the sensor and control unit clean and free from dust and moisture.
- Do not use abrasive cleaners or solvents on the device.
- Regularly check wiring for any signs of wear or damage. If damage is found, disconnect power immediately and replace the unit.
- No user-serviceable parts inside. Refer to safety warnings regarding disassembly.
Troubleshooting
- Switch not responding to touch:
- Ensure the power supply is connected and active.
- Verify that the sensor pad is securely mounted and not on a metallic or mirrored surface.
- Check the thickness of the penetrating material. The F47 model supports up to 3cm, and the F100 model supports up to 5cm. If the material is too thick, the sensor may not detect touch.
- Confirm all wiring connections are correct and secure according to the diagram.
- If the issue persists, the unit might be faulty.
- Appliance turns ON only when hand is held on the sensor (MODE B issue):
- This behavior is characteristic of MODE A. If you intended to use MODE B (toggle on/off), ensure you have selected the correct product variant or that the unit is functioning as expected for MODE B. Some users have reported receiving units that behave like MODE A when expecting MODE B, which might indicate a product variant issue or a defect.
- Light flickers or does not turn on/off reliably:
- Check for loose wiring connections.
- Ensure the connected load's power consumption does not exceed the switch's maximum rating of 400 Watts.
- Verify that the output voltage of the switch matches the input voltage requirements of your appliance.
User Tips
- Installation Order: It is crucial to complete all physical installation steps, including mounting the sensor and wiring, before connecting the power supply. This ensures proper calibration and functionality.
- Sensor Sensitivity: The sensor is generally sensitive and works well through compatible materials within its specified penetration depth.
- Testing: Before final installation, perform a quick test to ensure the sensor responds as expected through your chosen material.
Warranty and Support
This product comes with a 1-year warranty from the date of purchase. The warranty covers manufacturing defects under normal use. It does not cover damage caused by improper installation, misuse, accidents, or unauthorized modifications.
For further assistance or detailed documentation, please refer to the official user manual PDF available from the seller or contact customer support.
A PDF version of the user manual is available for download. Search for "Item guides & documents" on the product page or contact the seller for the link.