Introduction
The GGBEE L07 Infrared Motion Sensor is a new energy-saving switch designed for convenience, safety, and practical functionality. It integrates a highly sensitive detector and an integrated circuit to automatically control lighting based on human infrared energy. The device activates the connected load when a person enters its detection field and can distinguish between day and night conditions. Its user-friendly design ensures easy installation and widespread application.
Specifications
| Feature | Specification |
|---|---|
| Model Number | L07 (1006A) |
| Brand Name | GGBEE |
| Power Source | AC 110-240V |
| Power Frequency | 50Hz |
| Rated Current | 4A |
| Rated Load | 800W (incandescent lamp), 300W (energy-saving lamp & LED) |
| Ambient Light | 3-2000LUX (adjustable) |
| Time-Delay | Min: 10sec ± 3sec, Max: 7min ± 2min |
| Detection Distance | 3-12m (<24°C) (adjustable) |
| Detection Range | 180° |
| Working Temperature | -20°C ~ +40°C |
| Working Humidity | <93%RH |
| Installation Height | 1.8m ~ 2.5m |
| Power Consumption | 0.45W (work), 0.1W (static) |
| Detection Motion Speed | 0.6 ~ 1.5m/s |
| Certification | CE |
| Origin | Mainland China |
Setup
Installation Guidelines
- **Safety First**: Always switch off the power before installation. Installation should be performed by a qualified electrician or experienced person.
- Unscrew the nail on the front cover. Open the wire hole. The power wire and the load wire are routed through the bottom.
- Fix the bottom part of the sensor to the desired position using the provided inflated screw.
- Connect the power and the load to the connection-wire column according to the wiring diagram provided below.
- Fix the front cover of the sensor, screw the nail, and then switch on the power to test the device.
Wiring Diagram
Refer to the diagram below for correct wiring connections. Ensure all connections are secure.
Connection Details:
- Blue (N): Connect to the neutral wire.
- Brown (L): Connect to the live wire.
- Red (OUT): Connect to the load's live wire.
- The blue and brown wires serve as the input power supply.
- The blue and red wires connect to the load clamp.
Installation Environment Considerations
- Avoid installing on unstable surfaces.
- Ensure no obstructions or moving objects are in front of the detection window to prevent interference with detection.
- Do not install near areas with significant air temperature changes, such as air conditioners or central heating vents.
Installation and Function Demonstration Video
Operating Instructions
Function Overview
- Day and Night Identification: The sensor can be adjusted to operate during the day, at night, or only in low light conditions.
- SENS (Sensitivity) Adjustment: Adjust the detection distance based on the installation location. Lower sensitivity (e.g., 5m) is suitable for focused detection, while higher sensitivity (e.g., 12m) is ideal for larger rooms.
- Time-Delay Adjustment: The duration the light stays on after motion is detected can be set from a minimum of 10 seconds (±3 seconds) to a maximum of 7 minutes (±2 minutes).
- Continual Time-Delay: If the sensor receives a second induction signal after the first, it will recalculate the time delay from that moment, ensuring the light remains on as long as motion is detected.
Adjustment Knobs
- SENS Knob: Controls sensitivity/detection distance.
- TIME Knob: Adjusts the time delay.
- LUX Knob: Sets the ambient light threshold for operation (Sun position for all-day sensing, Moon position for night-only sensing).
Testing Procedure
- Turn the SENS knob clockwise to maximum, the TIME knob anti-clockwise to minimum, and the LUX knob clockwise to maximum (SUN position).
- When power is switched on, the connected load should initially be off. After a 30-second preheat period, the load will turn on when the sensor detects motion. Once the load turns off, it will reactivate within 5-15 seconds upon detecting new motion.
- After the first detection cycle, trigger the sensor again after 5-10 seconds. The load should activate. If no further motion is detected, the load should stop working.
- Turn the LUX knob anti-clockwise to minimum (Moon position). In this setting, the sensor and load will not operate during daylight. If you cover the detection window with an opaque object (e.g., a towel), the load should activate. Without any induction signal, the load should stop working within 5-15 seconds.
Note: When testing in daylight, ensure the LUX knob is set to the SUN position; otherwise, the sensor lamp may not function correctly.
Maintenance
The GGBEE L07 motion sensor requires minimal maintenance. To ensure optimal performance:
- Keep the detection lens clean and free from dust or debris. Use a soft, dry cloth for cleaning.
- Periodically check wiring connections to ensure they remain secure.
- Avoid painting over the sensor lens or housing, as this can impair its functionality.
Troubleshooting
Problem: The connected load does not work.
- Solution 1: Verify that the power and load wiring connections are correct according to the diagram.
- Solution 2: Check if the load (e.g., light bulb) is functional.
- Solution 3: Ensure the working light setting (LUX knob) corresponds to the ambient light conditions.
Problem: The sensitivity is poor.
- Solution 1: Check for any obstructions in front of the detection window that might block the signal.
- Solution 2: Note that ambient temperature can affect sensitivity; if the temperature is too high, sensitivity may decrease.
- Solution 3: Confirm that the induction signal source (person) is within the detection field.
- Solution 4: Ensure the installation height is within the recommended range of 1.8m to 2.5m.
- Solution 5: Check if the moving orientation is correct relative to the sensor.
Problem: The sensor does not shut off the load automatically.
- Solution 1: Check for continuous motion signals within the detection field.
- Solution 2: Verify that the time delay setting (TIME knob) is not set to its longest duration.
- Solution 3: Ensure the power consumption of the load corresponds to the product's specifications.
- Solution 4: Check for significant temperature changes near the sensor, such as from an air conditioner or central heating, which can interfere with its operation.
User Tips
- Detection Range: While effective, the detection range may not be extremely wide. It is excellent for focusing on specific areas where precise detection is needed.
- Ease of Installation & Adjustment: Users have found the sensor very easy to connect and install, with straightforward manual adjustments for sensitivity, time, and light level.
- Angle Adjustment: The sensor's angle can be adjusted. Although it may not have a dedicated fixing screw for the angle, the interlocking fit is generally sufficient once the desired position is set.
Warranty and Support
For any issues not covered in this manual or for warranty inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt for reference.
A detailed user manual in PDF format is also available for download: View User Manual (PDF)