Diymore DC5V-Single Module

Contents

DC5V Unswitched 4 Spray Humidifier Module Atomization Control Board User Manual

Model: DC5V-Single Module | Brand: Diymore

1. Introduction

This manual provides detailed instructions for the setup, operation, and maintenance of your Diymore DC5V Unswitched 4 Spray Humidifier Module Atomization Control Board. This module is designed for DIY projects, plant moisturizing, and other applications requiring continuous fog output.

2. Features

  • High-quality product, compact in size, and easy to install.
  • Convenient application with four-head spray and strong fog volume.
  • Continuous spray operation without the need for a power switch.
  • Upgraded TYPE-C interface for strong versatility and stable performance.
  • High efficiency and stability, ensuring a long service life when electrified.
  • Wide range of applications including DIY projects and plant moisturizing.
  • Module set is ready to use, with brackets and cotton swabs for easy assembly.

3. Specifications

ParameterValue
NameUnswitched atomization drive board
Material1.2MM FR-4
Power PlugTYPE-C interface
Rated VoltageDC5V (power supply)
Rated Current300MA (minimum 2A)
Power2.5-3W
Atomization Frequency108KHZ ± 2KHZ
Module Dimensions57 * 19MM
Cotton Swab Dimensions7 * 121MM
Nebulizer Drive Voltage5V
Nebulizer Resonant Frequency108-110KHZ ± 5
Nebulizer Rated Power2W
Nebulizer Punch Count1100
Nebulizer Aperture4-5UM
Outer Diameter of Silicone Sleeve20MM
Rubber Ring Thickness3MM
Steel Plate Diameter16MM
Line Length25CM
Wire TerminalPH2.0

4. Package Contents

Depending on the package option purchased, your product may include:

Package 1:

  • 1x Atomization Drive Module

Package 2:

  • 1x Atomization Drive Module
  • 1x Fixed Bracket
  • 4x Transparent Cotton Stick Holders
  • 4x Support Seats
  • 4x Springs
  • 4x Cotton Swabs
  • 4x Nebulizers

5. Safety Precautions

Attention: DC5V (power supply), no no-load use is allowed. Use 4 nozzles at the same time, otherwise it may cause board burning!

  • It is strictly prohibited to puncture the atomizing plate.
  • The welding points of the atomizing plate cannot be folded or pulled.
  • It is strictly prohibited to power on the module without connecting the atomizing plate.
  • It is strictly prohibited to use fast chargers with this module.
  • It is strictly prohibited to modify the modules.
  • The module (control board) must not come into contact with water.
  • Ensure the full steel sheet (raised surface) of the nebulizer is in downward contact with the cotton swab to absorb water.
  • Pay attention to the positive and negative poles when connecting an external power supply.
Image showing usage precautions for the humidifier module
Important usage precautions for the humidifier module.

6. Setup Instructions

Follow these steps to assemble and set up your humidifier module:

  1. Install the Atomizer Bracket: First, install the atomizer bracket. Ensure the smooth steel surface of the nebulizer is facing upwards for proper spray. Find the card slot on the bracket, align the nebulizer, and press it down firmly.
  2. Prepare the Cotton Swab: Place the spring into a transparent tube. Insert a cotton swab into the tube. The cotton swab must be thoroughly soaked in water before it can spray effectively.
  3. Assemble Atomizer Units: Install the prepared atomizer units (nebulizer, spring, cotton swab, and transparent tube) sequentially onto the main bracket.
  4. Connect Atomizing Plates to Module: Connect the wires from each atomizing plate to the corresponding electrical ports on the main control module. If connecting to an external power source, pay close attention to the positive and negative poles.
  5. Position in Water: Place the assembled atomizer units into a container of water, ensuring the nebulizers are submerged and the cotton swabs can absorb water. The control module itself must remain dry and not touch water.
  6. Connect Power Supply: Connect the Type-C power supply to the module's power port.
  7. Start Spray: The module is designed for continuous spray without a switch. Once the power supply is connected and the atomizers are in water, spraying should begin automatically.
Official installation video demonstrating the assembly process.
User setting up the humidifier module in a container of water
Example of the module being set up in a water container.

7. Operating Instructions

Once the module is correctly assembled and connected to a DC5V power supply with the atomizers submerged in water, the unit will begin to spray fog automatically. There is no separate power switch on the module itself for continuous operation.

Humidifier module actively producing mist in a water container
The humidifier module in operation, producing mist.

8. Maintenance

  • Regularly check the cotton swabs and replace them if they become dirty or worn to ensure optimal water absorption and mist output.
  • Keep the control module dry at all times. Avoid any contact with water.
  • Do not attempt to clean the atomizing plate by puncturing it or pulling on its welding points.
  • Ensure the power supply is disconnected before performing any maintenance.

9. Troubleshooting

  • No Fog Output:
    • Ensure the cotton swabs are fully saturated with water.
    • Verify that all four nebulizers are connected to the module. Operating with fewer than four connected nebulizers can cause issues or damage.
    • Check the power supply connection and ensure it is providing a stable DC5V. Avoid using fast chargers.
    • Confirm the nebulizers are properly submerged in water and the steel sheet is in contact with the cotton swab.
    • Inspect the atomizing plates for any damage or punctures.
  • Weak Fog Output:
    • Ensure the cotton swabs are clean and fully saturated.
    • Check for proper water level, ensuring the nebulizers are adequately submerged.
    • Verify the power supply meets the rated specifications (DC5V, minimum 2A current).
  • Module Overheating/Burning Smell:
    • Immediately disconnect power. This can be caused by operating without all four nebulizers connected or by using an incorrect power supply (e.g., fast charger).
    • Ensure the module itself has not come into contact with water.

10. User Tips

  • When installing the piezo (atomizer), pay close attention to its orientation. Ensure the smooth steel surface is facing upwards for optimal performance.
  • For DIY projects, this module is a cost-effective solution, though the mist output might not be as dense as higher-end humidifiers. It's great for fun projects.
  • Always ensure the cotton swabs are fully soaked before powering on to prevent dry running and potential damage.

11. Warranty and Support

For any issues or questions regarding your Diymore Humidifier Module, please refer to the seller's support channels or the official product page for assistance.

12. Additional Resources

A detailed user manual in PDF format is available for download:

Download User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.