1. Introduction
This manual provides detailed instructions for the setup, operation, and maintenance of your Diymore DC5V Unswitched 4 Spray Humidifier Module Atomization Control Board. This module is designed for DIY projects, plant moisturizing, and other applications requiring continuous fog output.
2. Features
- High-quality product, compact in size, and easy to install.
- Convenient application with four-head spray and strong fog volume.
- Continuous spray operation without the need for a power switch.
- Upgraded TYPE-C interface for strong versatility and stable performance.
- High efficiency and stability, ensuring a long service life when electrified.
- Wide range of applications including DIY projects and plant moisturizing.
- Module set is ready to use, with brackets and cotton swabs for easy assembly.
3. Specifications
| Parameter | Value |
|---|---|
| Name | Unswitched atomization drive board |
| Material | 1.2MM FR-4 |
| Power Plug | TYPE-C interface |
| Rated Voltage | DC5V (power supply) |
| Rated Current | 300MA (minimum 2A) |
| Power | 2.5-3W |
| Atomization Frequency | 108KHZ ± 2KHZ |
| Module Dimensions | 57 * 19MM |
| Cotton Swab Dimensions | 7 * 121MM |
| Nebulizer Drive Voltage | 5V |
| Nebulizer Resonant Frequency | 108-110KHZ ± 5 |
| Nebulizer Rated Power | 2W |
| Nebulizer Punch Count | 1100 |
| Nebulizer Aperture | 4-5UM |
| Outer Diameter of Silicone Sleeve | 20MM |
| Rubber Ring Thickness | 3MM |
| Steel Plate Diameter | 16MM |
| Line Length | 25CM |
| Wire Terminal | PH2.0 |
4. Package Contents
Depending on the package option purchased, your product may include:
Package 1:
- 1x Atomization Drive Module
Package 2:
- 1x Atomization Drive Module
- 1x Fixed Bracket
- 4x Transparent Cotton Stick Holders
- 4x Support Seats
- 4x Springs
- 4x Cotton Swabs
- 4x Nebulizers
5. Safety Precautions
Attention: DC5V (power supply), no no-load use is allowed. Use 4 nozzles at the same time, otherwise it may cause board burning!
- It is strictly prohibited to puncture the atomizing plate.
- The welding points of the atomizing plate cannot be folded or pulled.
- It is strictly prohibited to power on the module without connecting the atomizing plate.
- It is strictly prohibited to use fast chargers with this module.
- It is strictly prohibited to modify the modules.
- The module (control board) must not come into contact with water.
- Ensure the full steel sheet (raised surface) of the nebulizer is in downward contact with the cotton swab to absorb water.
- Pay attention to the positive and negative poles when connecting an external power supply.

6. Setup Instructions
Follow these steps to assemble and set up your humidifier module:
- Install the Atomizer Bracket: First, install the atomizer bracket. Ensure the smooth steel surface of the nebulizer is facing upwards for proper spray. Find the card slot on the bracket, align the nebulizer, and press it down firmly.
- Prepare the Cotton Swab: Place the spring into a transparent tube. Insert a cotton swab into the tube. The cotton swab must be thoroughly soaked in water before it can spray effectively.
- Assemble Atomizer Units: Install the prepared atomizer units (nebulizer, spring, cotton swab, and transparent tube) sequentially onto the main bracket.
- Connect Atomizing Plates to Module: Connect the wires from each atomizing plate to the corresponding electrical ports on the main control module. If connecting to an external power source, pay close attention to the positive and negative poles.
- Position in Water: Place the assembled atomizer units into a container of water, ensuring the nebulizers are submerged and the cotton swabs can absorb water. The control module itself must remain dry and not touch water.
- Connect Power Supply: Connect the Type-C power supply to the module's power port.
- Start Spray: The module is designed for continuous spray without a switch. Once the power supply is connected and the atomizers are in water, spraying should begin automatically.

7. Operating Instructions
Once the module is correctly assembled and connected to a DC5V power supply with the atomizers submerged in water, the unit will begin to spray fog automatically. There is no separate power switch on the module itself for continuous operation.

8. Maintenance
- Regularly check the cotton swabs and replace them if they become dirty or worn to ensure optimal water absorption and mist output.
- Keep the control module dry at all times. Avoid any contact with water.
- Do not attempt to clean the atomizing plate by puncturing it or pulling on its welding points.
- Ensure the power supply is disconnected before performing any maintenance.
9. Troubleshooting
- No Fog Output:
- Ensure the cotton swabs are fully saturated with water.
- Verify that all four nebulizers are connected to the module. Operating with fewer than four connected nebulizers can cause issues or damage.
- Check the power supply connection and ensure it is providing a stable DC5V. Avoid using fast chargers.
- Confirm the nebulizers are properly submerged in water and the steel sheet is in contact with the cotton swab.
- Inspect the atomizing plates for any damage or punctures.
- Weak Fog Output:
- Ensure the cotton swabs are clean and fully saturated.
- Check for proper water level, ensuring the nebulizers are adequately submerged.
- Verify the power supply meets the rated specifications (DC5V, minimum 2A current).
- Module Overheating/Burning Smell:
- Immediately disconnect power. This can be caused by operating without all four nebulizers connected or by using an incorrect power supply (e.g., fast charger).
- Ensure the module itself has not come into contact with water.
10. User Tips
- When installing the piezo (atomizer), pay close attention to its orientation. Ensure the smooth steel surface is facing upwards for optimal performance.
- For DIY projects, this module is a cost-effective solution, though the mist output might not be as dense as higher-end humidifiers. It's great for fun projects.
- Always ensure the cotton swabs are fully soaked before powering on to prevent dry running and potential damage.
11. Warranty and Support
For any issues or questions regarding your Diymore Humidifier Module, please refer to the seller's support channels or the official product page for assistance.
12. Additional Resources
A detailed user manual in PDF format is available for download: