HOMEFISH 5-in-1 Air Quality Monitor

Contents

HOMEFISH 5-in-1 Air Quality Monitor User Manual

Model: 5-in-1 Air Quality Monitor

Brand: HOMEFISH

1. Introduction

Thank you for purchasing the HOMEFISH 5-in-1 Air Quality Monitor. This device is a multi-in-one air detector designed to measure various real-time indicators in the air, including Carbon Dioxide (CO2), Formaldehyde (HCHO), Total Volatile Organic Compounds (TVOC), Temperature, and Humidity. It is widely applicable in various environments such as homes, offices, gyms, cinemas, warehouses, and greenhouses.

The monitor features a clear LCD digital color screen for easy reading and provides real-time updates every second. When main detection indicators exceed predefined alarm values, the device will trigger a buzzer alarm to alert users to changes in air quality.

HOMEFISH 5-in-1 Air Quality Monitor with key specifications
Front view of the HOMEFISH 5-in-1 Air Quality Monitor, highlighting CO2, Temperature, Humidity, TVOC, and HCHO detection, along with key specifications like CO2 range (400-5000PPM), HCHO (0-0.6mg/m³), TVOC (0-2.0mg/m³), TEMP (0-50°C), HUMI (0-99%RH), and Battery (1200 mAh).
Application scenarios for the air quality monitor
Collage showing various application scenarios for the air quality monitor, including homes, offices, greenhouses, warehouses, and wine cellars.

2. Package Contents

Upon opening the package, please ensure all the following items are included:

  • 1 x Air Quality Detector (Host)
  • 1 x USB-TYPE-C Charging Cable
  • 1 x User Manual (Guideline)
Contents of the product package
Image showing the air quality monitor, a USB-C charging cable, and the instruction manual, suggesting the contents of the package.

3. Specifications

The HOMEFISH 5-in-1 Air Quality Monitor features the following technical specifications:

ParameterRangeAccuracy
CO2 Measuring Range400ppm - 5000ppm±1%
HCHO (Formaldehyde)0 - 0.6 mg/m³N/A
TVOC (Total Volatile Organic Compounds)0 - 2.0 mg/m³N/A
Temperature0°C - 50°CN/A
Humidity0% - 99% RHN/A
Battery3.7V, 1200mAh (Built-in Lithium Battery)N/A
Standby TimeApprox. 240 - 360 minutesN/A
Item Size90 * 70 * 35mm / 3.54 * 2.76 * 1.38inN/A
Item Weight100g / 3.53ounceN/A
Diagram of air quality monitor features
Diagram illustrating the various functions of the air quality monitor, including CO2 Detection, Automatic Calibration, Anti-interference, Accurate Sensor, Alarm Buzzer, Temperature/Humidity, CO2 Index, HCHO (Formaldehyde) Detection, and TVOC Detection.
Table of product models and detection capabilities
Table from the instruction manual detailing detection ranges and capabilities for different models (3 in 1 CO, 3 in 1 CO2, 5 in 1, 6 in 1) across various parameters like CO2, temperature, humidity, HCHO, TVOC, PM2.5, PM10, CO, and AQI.

4. Setup

4.1 Charging the Device

The air quality monitor has a built-in lithium battery. Before first use, or when the battery is low, charge the device using a standard DC-5V charger and the provided USB-TYPE-C charging cable. Connect the Type-C end of the cable to the device's charging port and the USB-A end to a compatible power adapter.

Device with Type-C charging interface
Close-up of the device showing the Type-C charging interface and indicating a 1200mAh rechargeable battery.

4.2 Powering On

To turn on the device, long press the power button. After powering on, the sensor requires approximately 120 seconds to warm up and stabilize. During this warm-up period, the real-time index values of the current environment will be displayed.

4.3 Placement

The device supports two installation methods: desktop placement or wall mounting. Choose a location that allows for proper air circulation and is away from direct heat sources, moisture, or strong magnetic fields.

Wall mounted and desktop placed installation methods
Image demonstrating two installation methods: Wall Mounted and Desktop Placed, showing the back of the device with a speaker grille.

5. Operating Guide

5.1 Display Overview

The LCD screen displays real-time readings for CO2, HCHO, TVOC, Temperature, and Humidity. A battery indicator is also present to show the current charge level.

LCD display with labeled readings
Detailed view of the 5-in-1 Indoor Air Quality Meter's LCD screen, with labels pointing to CO2 Display, Formaldehyde Display (HCHO), TVOC Display, Temperature Display, and Humidity Display.

5.2 Understanding CO2 Levels and Indicators

The device uses flashing lights to indicate the grade of CO2 concentration:

  • 0-799 PPM: Green light flashing (Good air quality)
  • 800-1199 PPM: Light green light flashing (Moderate air quality)
  • 1200-1599 PPM: Orange light flashing (Poor air quality, consider ventilation)
  • 1600-1999 PPM: Flashing red light (Very poor air quality, immediate ventilation recommended)
  • 2000 PPM and above: Four lights flash (Hazardous air quality, urgent action required)
CO2 concentration level indicators
Series of display examples illustrating CO2 concentration levels (0-799 PPM, 800-1199 PPM, 1200-1599 PPM, 1600-1999 PPM, 2000 PPM and above) and their corresponding flashing light indicators (Green, Light Green, Orange, Flashing Red, Four lights flash).

5.3 Calibration Sensor

To calibrate the sensor, double-click the designated button (refer to the device's physical buttons for exact location).

6. Care and Precautions

To ensure the longevity and accurate operation of your air quality detector, please observe the following:

  • **Charging:** Always use a standard DC-5V charger for the built-in lithium battery.
  • **Airflow:** When the product is operating, ensure the air inlet and outlet are not blocked to prevent numerical deviations.
  • **Environment:** Avoid frequent use in dusty environments with poor air quality to extend the device's service life.
  • **Storage & Operation Temperature:** The product can be used in a temperature range of 0°C to 45°C. Store equipment and accessories in a temperature range of -10°C to 55°C.
  • **Environmental Extremes:** Do not use the device near high temperatures, high humidity, dirt, or strong magnetic fields, as this can lead to inaccurate values or internal circuit faults. When the ambient temperature is too high or too low, the device may malfunction.
  • **Moisture Protection:** Keep equipment and accessories away from exposure to rain or moisture, which could cause faults or risks to the display, battery, housing, and circuits.
  • **Physical Damage:** Do not insert sharp objects such as needles into the air inlet, air outlet, or charging port. Doing so may damage the device.

7. Troubleshooting

7.1 Fluctuating Readings

It is normal for air quality values, especially CO2, HCHO, and TVOC, to fluctuate. Air composition is dynamic and can change rapidly due to factors like human presence, ventilation, cooking, or nearby activities. The device provides real-time updates, so minor fluctuations are expected and reflect the current environment. If you experience unusually large or inconsistent fluctuations, ensure the device is placed in an area with good air circulation and away from direct drafts or localized sources of pollutants.

8. User Tips

  • For initial setup, allow the device to warm up for the recommended 120 seconds to ensure accurate readings.
  • Place the monitor in a central location within the area you wish to monitor for the most representative readings.
  • Regularly check the battery level and recharge as needed to avoid interruptions in monitoring.

9. Warranty and Support

For any questions or issues regarding the product, please refer to the contact information of the manufacturer, which is typically printed on the label of the product box or included in the packaging. Please retain your purchase receipt for warranty purposes.

Page 1 of the instruction manual
Page 1 of the instruction manual, detailing product introduction, operation guide, and attention points.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.