1. Overview and Introduction
This user manual provides comprehensive information, operating instructions, and maintenance guidelines for the PowMr POW-LIO48100-16S low-voltage residential energy storage battery. This lithium battery system is designed for compatibility with various inverter brands available in the market.
The POW-LIO48 series is a battery module developed by PowMr for low-voltage lithium battery systems, primarily for residential energy storage. It features high-precision multi-cell voltage and temperature acquisition, a passive balancing method (up to 300mA balancing current), and external communication interfaces (CAN, RS485, dry contact) allowing parallel communication for up to 16 batteries. An embedded Battery Management System (BMS) effectively monitors for over-temperature, over-voltage, and over-current, significantly reducing risks and ensuring safety.
1.1 Key Advantages
- Battery Chemistry: Utilizes Lithium Iron Phosphate (LiFePO4) material, known for its high safety performance and a cycle life exceeding 6,000 times.
- Intelligent Management: Features a high-performance intelligent management system for comprehensive control over charging, discharging, floating charge, and hibernation, with multi-level protection for voltage, current, and temperature.
- Comprehensive Monitoring: Continuously monitors voltage, current, temperature, capacity, and overall battery status.
- Remote Control Capability: Designed to meet national standards for telemetry, remote signaling, remote control, and remote adjustment.
- Cell Balancing: Includes a built-in intelligent balance module to maintain capacity consistency and prolong battery pack lifespan.
- User Interface: A control panel provides status display and alarm devices for visual monitoring of working status and alarm information.
- Thermal Management: Equipped with an intelligent thermal management device, allowing operation across a wide temperature range.

Figure 1: PowMr 48V 100AH LiFePo4 Battery (Model POW-LIO48100-16S) showing 5.12KWh Nominal Energy, 100A Max. Charging Current, and RS232/RS485/CAN/Dry Communication Interface.

Figure 2: Comparison of POW-LIO48100-16S LiFePo4 battery with Lead-Acid batteries of similar specifications. LiFePo4 offers higher energy density, lower weight (44KG vs 100KG), significantly longer cycle life (6000 vs 300-500 cycles), deeper discharge depth (98% vs 70-75%), and is maintenance-free.

Figure 3: The PowMr LiFePo4 battery ensures energy security for various applications including PV Systems, Yachts, RVs, and during Power Outages.
2. Safety Instructions
To ensure user safety and prevent damage to the product, please read and adhere to all safety instructions.
2.1 Labeling Explanation
- DANGER: Signifies a low-level potential hazard. Failure to avoid may result in minor or moderate injury to personnel.
- HIGH VOLTAGE: Indicates the presence of high voltage inside the battery module. Touching may lead to electric shock hazards.
- GROUND: This is the ground protection port (PE). It should be securely grounded to ensure the safety of operating personnel.
2.2 General Precautions
- Manual Storage: Keep this manual in a readily accessible location for future reference by installation and maintenance personnel. Strictly follow all instructions to avoid equipment damage, injuries, or property loss.
- Label Protection: Do not intentionally tear or damage warning labels or the product nameplate, as they contain crucial safety and parameter information.
- Safety Warning Labels: During installation, maintenance, or inspection, erect clear signage at switch locations and use warning tape around the operating area to prevent unauthorized access or accidents. Always conduct a thorough safety check after any work.
- Personnel Requirements: Only professionally qualified personnel should perform operations on this product. Operating personnel must be thoroughly familiar with the entire system's composition, working principles, and this user manual.
2.3 Power-On Measurement & Measuring Instruments
- DANGER: High voltage is present after installation. When performing power-on measurements, always wear insulated gloves and have accompanying personnel present to ensure safety.
- WARNING: Use electrical measuring equipment (multimeters, power meters) with suitable ranges and ensure correct, standardized connections to avoid electric arcs or other dangers.
2.4 Maintenance and Inspection
- WARNING: Before any maintenance or inspection, ensure both the energy storage battery and the inverter are turned off, and electrical connections are confirmed to be disconnected.
- Ensure the battery cannot be accidentally re-energized.
- Use a multimeter to confirm the battery is completely de-energized.
- For parts near potentially live components, use insulating materials for covering or grounding.
- Never perform maintenance or inspection on live equipment. At least two personnel must be present during maintenance operations, which should only proceed after the equipment is safely de-energized, fully charged, or discharged.
3. Package Contents
Upon unpacking, please verify that all items listed below are present and undamaged:
| No. | Item | Quantity |
|---|---|---|
| 1 | PowMr 48V 100AH LiFePo4 Battery | 1 |
| 2 | 1.5-meter Red-Positive Power Line (35mm²) | 1 |
| 3 | 1.5-meter Black-negative Power Line (35mm²) | 1 |
| 4 | 1-meter Communication Cable | 1 |
| 5 | Product User Manual | 1 |
| 6 | Certificate of Conformity | 1 |
| 7 | Expansion Bolt | 9 |
| 8 | Wall Mount Bracket (For POW-LIO48100-16S) | 1 |
| 9 | Warranty Card | 1 |
4. Setup and Installation
4.1 Required Tools
- Electric drill
- Hammer
- Wrench
- M8*60 expansion bolt
- Phillips screwdriver
- Multimeter
- Insulated gloves
- Ethernet cable
- Power cable
4.2 Installation Preparation
- Ensure installation, operation, and maintenance are carried out by trained and qualified professionals.
- Read all safety precautions and operating procedures carefully before installation.
- Strictly abide by all safety regulations to prevent injury or product damage.
- Confirm the inverter connected to the battery is a qualified power system.
- Before installing the battery, ensure the power system and the battery pack are turned off.
- All power cables must have appropriate insulation; do not expose power cords.
- Ensure the battery and power system are reliably grounded during installation.
4.3 Installation Notes
- Space and Load Bearing: Ensure sufficient fixed components for installation and that the mounting bracket or cabinet can bear the battery's weight.
- Cable Specifications: Use power supply lines that meet the maximum current requirements of equipment operation.
- Project Layout: Plan the layout of power equipment and batteries for optimal arrangement.
- Wiring Layout: Ensure wiring is neat, orderly, and consider moisture and corrosion prevention.
- Personal Safety: Wear an anti-static wristband throughout the installation. At least two people should be present for the installation. Ensure the installation site is safe.
4.4 Wall-Mounted Installation Steps
- Wall Selection: Choose a solid wall with a thickness greater than 150mm.
- Clearance: Leave approximately 200mm clearance around the left, right, top, and bottom of the battery for adequate airflow.
- Bracket Attachment: Secure wall bracket A to the battery using the 8 dedicated screws provided.
- Marking Holes: Refer to the fixing distance of wall-mount bracket B bolts and mark the hole positions on the wall.
- Drilling: Drill 6 holes according to the marked positions, with a depth of at least 80mm.
- Expansion Bolts: Insert M8 expansion bolts into the upper holes and screw on the nuts.
- Mounting Bracket: Fix the mounting bracket to the wall using expansion bolts.
- Battery Mounting: While keeping the battery vertical, raise it slightly higher than the mounting bracket and carefully hang the battery onto the bracket.
4.5 Electrical Connection
4.5.1 Single Unit Wiring
- Connect the positive (+) and negative (-) terminals of the battery to the corresponding positive and negative terminals of the inverter using the provided power cables.
- Complete the battery's grounding connection using a ground wire.
- Connect the RS485A (or CAN) port of the battery to the RS485 (or CAN) communication port of the inverter using the communication cable.
- If operating as a single unit, set the ADS DIP switch to position 1. Refer to the DIP switch definitions for details.
4.5.2 Parallel Wiring (for multiple batteries)
- Initial Check: If using multiple batteries in parallel, manually press the low-voltage switch (ON/OFF) on each battery. Use a multimeter to check if the voltage of each battery is consistent. If consistent, turn off all batteries before proceeding.
- Power Cable Connection: Connect the positive terminal of each battery using a power cable, and then connect the negative terminal of each battery using a power cable.
- Communication Cable Connection: Connect the RS485B communication interface of adjacent batteries with communication cables. (RS485B battery parallel ports have identical functionality).
- Grounding: Connect a ground wire to the grounding point for all batteries. The ground symbol is typically found in the lower-left corner of the battery; attach the ground wire terminal here.
- Inverter Communication: Use a standard Category 6 cable. Connect one end to the RS485A (or CAN) communication interface of the battery and the other end to the RS485 (or CAN) interface of the inverter. Ensure the pin definition of the inverter communication matches that of the battery.
- Main Power Connection: Connect the positive terminal (+) of the first battery in the parallel chain to the positive terminal interface of the inverter using a power cable. Then, connect the negative terminal (-) of the last battery in the parallel chain to the negative terminal interface of the inverter using a power cable.
Note on DIP Switches for Parallel Operation: The battery directly connected to the inverter via the communication cable is defined as the host. The host's DIP switch should be set to 1 (before powering on). Define DIP switches for other batteries sequentially from 2 to 15, ensuring no duplication of switch settings.
5. Operation
5.1 Operating Principle
The PowMr LiFePo4 Battery Energy Storage System connects in parallel to the DC output of the inverter. When mains power is normal, the inverter supplies power to the load and charges the battery pack. If utility power and photovoltaic power are interrupted, the battery pack provides uninterrupted power to the inverter, ensuring continuous household electricity. When power is restored, the battery pack charges while power is supplied to household loads.
5.2 LCD Screen Operation Guide
The battery unit features an LCD screen for monitoring and configuration. The main buttons and their functions are:
- MENU: Enters the settings menu.
- ENTER: Enters the next-level menu.
- UP: Switches to the next option.
- ESC: Returns to the previous menu.
The LCD screen provides access to various parameters including Battery Pack Voltage, Charge/Discharge Current, Cell Temperature (for up to 4 groups), individual Cell Voltages (for 16 cells), Cell Capacity (SOC, FCC, RM, CC), Battery Operating Status (Idle, Charging, Discharging), Protection Records (Short Circuit, Over/Under Temperature, Overcurrent, Undervoltage, Overvoltage), and Current BMS Status.
5.3 DIP Switch Configuration (ADS)
The ADS DIP switches are used to define the battery's communication code, especially important for parallel connections. Each battery in a parallel system must have a unique DIP switch setting from 1 to 15. Refer to the detailed diagrams in the full PDF manual for specific switch combinations for each address.
6. Maintenance
- Do not immerse the battery in water. Store in a cool, dry environment when not in use.
- Do not expose the battery to fire or external heat to prevent explosion.
- Do not reverse the positive and negative poles. Never connect the battery directly to a power outlet, and avoid short-circuiting the terminals.
- Do not mix batteries from different manufacturers, types, or ages.
- Do not use batteries that show signs of heating, swelling, deformation, or leakage.
- Do not pierce the battery with sharp objects, throw, step on, hit, or impact it.
- Do not disassemble the battery or its components. Unauthorized disassembly voids warranty.
- If the battery shows signs of heating, swelling, or unusual odors, do not use it; return it immediately.
- For long-term storage, perform a charge-discharge cycle every three months, maintaining a storage charge of 40%~60%.
- Operate the battery within the specified temperature range.
- Always follow the specified power-up sequence for both the battery and the inverter.
- Ensure the load power does not exceed the maximum continuous discharge current.
- If the battery is unused for more than 3 months, perform manual charging periodically to prevent complete discharge.
- For specific technical issues not covered, contact technical support.
7. Troubleshooting
Refer to the table below for common issues and their solutions:
| Fault Symptom | Cause Analysis | Solution |
|---|---|---|
| No DC Output | Battery Voltage Too Low, Protection Activated | Startup after Charging Activation |
| Short Power Supply Time | Insufficient Battery Capacity or Failure to Reach Full Charge | Confirm Maintenance or Replace Battery |
| Battery Cannot Reach Full Charge | DC Voltage Output from Power System Lower than Minimum Charging Voltage | Adjust Device's DC Output Voltage to Suitable Charging Voltage for Battery |
| Unstable Battery Output Voltage with Significant Fluctuations | Interference with Management System Operation | Restart the System |
| Temperature Monitoring Too Low | Damage to Temperature-Sensing Crystal Head | Replace the Collection Line with a Temperature-Sensing Crystal Head |
| Unable to Charge | Single Cell Protection Activated upon Full Battery Charge | Discharge Protection Removal |
| MOS temperature abnormal | MOS tube damaged | Replace BMS |
| Discharge overcurrent protection | Inverter power exceeds limit | Match the number of batteries according to the inverter power value |
8. Specifications
Detailed technical specifications for the PowMr POW-LIO48100-16S battery:
| Parameter | Value |
|---|---|
| Battery Model | POW-LIO48100-16S |
| System Voltage | 51.2V |
| Capacity | 100Ah |
| Nominal Energy | 5.12KWh |
| Constant Voltage Charging Voltage | 58.4V |
| Max. Discharge Cutoff Voltage | 43.2V |
| Recommended Discharge Cutoff Voltage | 48V |
| Max. Charging Current | 100A |
| Recommended Charging Current | 40A |
| Max. Discharge Current | 100A |
| Max. Parallel Connection of Batteries | 16 |
| Communication Interface | RS232/RS485/CAN/Dry Contact |
| Cycle Life | ≥6000 Times @80%DOD, 25°C |
| Operating Temp (Charging) | 0~60°C |
| Operating Temp (Discharging) | -10°C~65°C |
| Nominal Operation Altitude | <2000m |
| Nominal Operation Humidity | <90%RH |
| IP Grade | IP21 |
| Recommended Operation Environment | Indoor |
| Battery Dimensions (LxWxH) | 550x470x202mm |
| Net Weight | 44kg |

Figure 4: Product label showing key specifications and certifications.
9. User Tips
- Ventilation: Ensure proper ventilation around the battery for optimal performance and longevity.
- Compatibility: Always use compatible charge controllers and inverters specifically designed for LiFePO4 battery chemistry.
- Connections: Regularly check terminal connections for tightness to prevent resistance buildup and potential overheating.
- Discharge Depth: Avoid frequently discharging the battery to 0% State of Charge (SOC), as this can reduce its overall cycle life. Aim for shallower discharges when possible to maximize battery lifespan.
10. Warranty and Support
For warranty claims and technical support, please refer to the Warranty Card included in your product package for specific terms and conditions.
10.1 Contact Information
Manufacturer: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Website: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China