CHZHVAN STC-X2

Contents

CHZHVAN 2-in-1 Smoke and Carbon Monoxide Detector User Manual

Model: STC-X2

Brand: CHZHVAN

1. Product Introduction

Thank you for purchasing the CPVAN carbon monoxide detector equipped with a digital LCD display! Please read these instructions carefully before using the carbon monoxide alarm. Retain this information in a safe and easily accessible place for future use and maintenance.

The CPVAN Carbon Monoxide Detector (CO detector) uses high-quality electrochemical sensors, combined with advanced electronic technology and sophisticated design for stable operation, long life, and other advantages. Once the concentration of carbon monoxide gas reaches the alarm setting value, the detector will emit an audible and visual alarm signal to remind you to quickly take effective measures to avoid the occurrence of fire, explosion, suffocation, death, and other malignancies.

Packing List

  • 1 x Carbon monoxide alarm
  • 1 x Mounting bracket
  • 1 x Screw Kit
  • 1 x User manual

For a comprehensive guide, you may also refer to the official User Manual PDF.

2. Important Safety Instructions

WARNING!

  1. Failure to read and follow these safety instructions can result in fires, explosions, or other hazards that may cause serious injury or property damage.
  2. To avoid the risk of suffocation, keep this product away from infants and children.
  3. Test the carbon monoxide detector once a week. Do not test your carbon monoxide alarm with an open flame. This could damage the detector or ignite flammable materials and cause a fire.
  4. Alkaline cells are primary batteries and must NOT be recharged.
  5. Attempting to recharge these products and batteries can lead to leakage and a possible explosion.
  6. The battery must not be altered, disassembled, opened, dropped, crushed, damaged, punctured, burned, or shredded.
  7. A loud alarm is a warning. Never ignore this alarm. Quickly check the source of the alarm to protect your property.
  8. Do not dispose of used batteries with household waste. Take them to an appropriate disposal/collection point.

3. Specifications

Product Dimensions

The detector measures 107 mm (D) x 38 mm (H).

Diagram showing the dimensions of the smoke and CO alarm, 108mm diameter and 36mm thickness.

Image: Diagram showing the dimensions of the smoke and CO alarm, 108mm diameter and 36mm thickness.

Main Specifications

AttributeValue
Product NameCarbon Monoxide Detector
Item No.STC-X2
Alarm ConditionEN50291-1:2018+AC:2021
Sensor TypePhotoelectric & Electrochemical
Power Supply4.5V DC (3 x 1.5V AA Batteries)
Recommended BatteriesSize AA Alkaline battery, Nanfu AA LR6, Gold Peak GN15A, Energizer EN91, Panasonic LR6XWA, Duracell MN1500
Operating Temperature0°C to 49°C (32°F to 120°F)
Storage Temperature-20°C to 50°C
Operating Humidity≤ 95% RH (Non-condensing)
Alarm Sound Level≥ 85 dB at 1 meter (3.4 ± 0.5 KHz pulsing alarm)
CO Alarm Sensitivity70 ppm: 60-180 min; 150 ppm: 10-50 min; 400 ppm: 4-15 min; 700 ppm: 2-6 min
Digital Display Accuracy25-999 ppm (±15%) at 20°C (±5°C)
Weight (without battery)120g
Battery Life3 years
Battery Low Voltage<3.6V
Standby Current≤ 15 µA
Alarm Current≤ 45 mA

What is Carbon Monoxide (CO)?

Carbon monoxide (CO) is a highly poisonous gas that has no taste, color, or smell, making it very difficult to detect with human senses. CO kills hundreds of people each year and injures many more. It binds to hemoglobin in the blood, reducing the amount of oxygen circulated in the body. In high concentrations, CO can be fatal in minutes. CO is produced from poorly burning appliances, such as:

  • Wood-burning stoves
  • Gas boilers and gas heaters
  • Oil and coal burning appliances
  • Blocked flues and chimneys
  • Waste gas from car garages
  • Barbecues

Symptoms Indicated by Carbon Monoxide Concentration Poisoning

CO Concentration in Air (ppm)Approximate Inhalation Time and Symptoms Developed
50 ppmThe maximum allowable concentration for continuous exposure for healthy adults in any 8-hour period.
200 ppmSlight headache, fatigue, dizziness, nausea after 2-3 hours.
400 ppmFrontal headaches within 1-2 hours, life threatening after 3 hours.
800 ppmDizziness, nausea and convulsions within 45 minutes. Unconsciousness within 2 hours. Death within 2-3 hours.
1,600 ppmHeadache, dizziness and nausea within 20 minutes. Death within 1 hour.
3,200 ppmHeadache, dizziness and nausea within 5-10 minutes. Death within 25-30 minutes.
6,400 ppmHeadache, dizziness and nausea within 1-2 minutes. Death within 10-15 minutes.
12,800 ppmDeath within 1-3 minutes.

NOTE:

  • Your detector detects a threat only where it is installed. Carbon monoxide must reach the detector at the described level and time to start alarming.
  • This apparatus is designed to protect individuals from the acute effects of carbon monoxide exposure. It will not fully safeguard individuals with specific medical conditions. If in doubt, consult a medical practitioner.
  • The apparatus may not prevent the chronic effects of carbon monoxide exposure, and it will not fully safeguard individuals at special risk.

This CO alarm meets these alarm response times (As required in EN50291-1:2018+AC:2021):

  • At 50 PPM, the unit must alarm within 60-90 minutes
  • At 100 PPM, the unit must alarm within 10-40 minutes
  • At 300 PPM, the unit must alarm within 3 minutes

4. Setup and Installation

Quick Setup

Observe the battery polarity markings at the bottom of the battery box, and install 3 pcs AA batteries into the battery box.

When the batteries are first installed, the unit will beep one time, and the red, green, and yellow LEDs will flash one by one for 30 seconds. '888 ppm' will be displayed with a white backlight. This indicates that the unit is preheating. Then the LCD will display '0 ppm', the backlight will be off, and the green LED will flash every 60 seconds, indicating that the unit is working. Fit on the battery cover. Your CO detector is now operational.

Front view of the CHZHVAN 2-in-1 Smoke and CO Detector showing the LCD display and indicator lights.

Image: Front view of the CHZHVAN 2-in-1 Smoke and CO Detector showing the LCD display and indicator lights.

Installation Locations

Common sources of CO include: oil and gas boilers, portable generators, oil or solid fuel cookers, gas or paraffin heaters, barbecues, clogged chimneys, wood or gas fireplaces, any gas or fossil fuel-burning appliance, and even adjoining properties.

Image showing the smoke and CO alarm installed in a living room, bedroom, and kitchen, indicating suitable placement areas.

Image: The detector is suitable for installation in various rooms such as the living room, bedroom, and kitchen.

Where to Install

The following suggestions are intended to help you with the placement and installation of your CO detector:

  • Do not install the CO alarm in areas that are excessively dusty, dirty, or greasy. Dust, grease, and household chemicals can affect the performance of the sensor.
  • Place out of the reach of children. Under no circumstances should children be allowed to handle the CO detector.
  • Install in a bedroom or hallway located close to the sleeping area. Take special care to verify the alarm can be heard in sleeping areas.
  • It is recommended that a CO detector be installed on each level of a multilevel home.
  • Locate at least 5 feet away from all fuel-burning appliances.
  • Placing at eye level (around 150cm - 300cm from the floor) allows for optimum monitoring of the red and green indicator lights.
  • It is permissible to mount the detector at the height of the bed in the bedroom or lay it on the bedside night table (CAUTION! - please take into account the very loud alarm!).
  • In exceptional circumstances, the detector can be used as a portable device and taken where you want to detect a threat. The detector should be moved with caution. Moving the sensor can cause damage and void the warranty.

NOTE: The installation of the CO alarm device should not be used as a substitute for proper installation, use, and maintenance of fuel-burning appliances, including appropriate ventilation and exhaust systems.

Mounting

  1. Using the template provided, mark the position of the two mounting holes.
  2. Drill two holes using a 6mm drill for the plastic plugs supplied (ensure you don't drill into the house wiring).
  3. Screw the unit to the wall.
Diagram showing how to install the smoke and CO alarm on a ceiling or wall with a simple twist motion.

Image: The detector is designed for easy installation in seconds, typically by twisting it onto a mounted bracket.

5. Operating Instructions

LCD Display and Indicators

The detector features a digital LCD display and 3-color LED indicators (Power, Alarm, Fault).

Image showing a hand pressing the 'TEST' button on the smoke and CO alarm, with an 85dB alarm icon.

Image: The detector features a one-click test button for rapid response and an 85dB alarm.

LCD Display ShowsAlarm SoundUnit StatusRecommendation
A display of CO concentration from 25-999 ppm. White backlight is lighted. Red LED flashes 4 times every 5 seconds.Four beeps, Repeated every 5 seconds.Concentration of CO detected. Alarm condition.Refer to 'What to do When the Alarm Sounds'.
'888 ppm' with white backlight (briefly on installation)Beep one time when installing batteries.Unit is good when first powered up and enters preheating status.
'0 ppm' is shown on the LCD. Green LED flashes every 60 seconds.None.Normal. Detecting CO status with good batteries.The unit is monitoring CO continuously.
'Lb' displayed. Yellow LED flashes every 60 seconds.One beep every 60 seconds.Batteries need to be replaced.Replace all three AA batteries immediately.
'Err' displayed. Yellow LED flashes 2 times every 60 seconds.Two beeps every 60 seconds.Unit is in malfunction status.Unit needs to be repaired or replaced immediately.
'HHH' displayed. White backlight is lighted. Red LED flashes 4 times.Four beeps, Repeated every 5 seconds.Concentrations of CO is more than 999 ppm.MOVE TO FRESH AIR IMMEDIATELY!!!
'End' displayed. Yellow LED flashes 3 times every 60 seconds.Three beeps every 60 seconds.End of unit life. About 10 years from first powered on.Replace unit immediately.

Note: It's forbidden for the user to disassemble the CO alarm privately, which may cause damage to the CO alarm.

Press Test Button

The detector includes a 'TEST' button for verifying proper unit operation.

  1. Press the button, the white backlight will illuminate. The unit will beep four times with Red flashes four times. It will then display the highest CO concentration (Peak level CO concentration) detected since the last button-test. The peak level CO concentration will then be cleared.
  2. The unit will then beep one time. The LCD will display 't t t' with the red, green, and yellow LEDs flashing one by one. This means the unit is self-testing.
  3. When the self-test is completed, the LCD will display 'PAS' if the unit is working well. The backlight will then turn OFF, and the LCD will display '0 ppm' with the green LED flashing every 60 seconds.
  4. If the unit was tested with a fault, the LCD will display 'Err' with the yellow LED flashing two times, and the buzzer will beep two times simultaneously. This cycle will repeat every 60 seconds.

Alarm Silence

  1. This unit has an Alarm Silence feature that allows you to press the TEST button on the detector and disable the 'beeps' for a period of 6 minutes. At the same time, the Red LED will continue to flash every 5 seconds, and the white backlight will be off. During this Alarm Silence Period, your detector is still monitoring for CO. If the CO concentration rises to more than 300 ppm during the Alarm Silence Period, the alarm will return to the alarm state.
  2. NOTE: If the CO concentration is greater than 300 ppm, the unit cannot enter the Alarm Silence Period. This is a very dangerous state; you must MOVE TO FRESH AIR IMMEDIATELY!!!
  3. The Alarm Silence Period will end when the 6 minutes silence time is reached. The unit will resume to alarm status if the CO level is still more than 40 ppm.
  4. The Alarm Silence Period will also end if the CO level is lower than 40 ppm. The unit will recover to normal CO monitoring status.
  5. In the Alarm Silence Period, if you press the test button again, the unit will resume to alarm status.

What to Do When Alarm Sounds

Activation of the alarm indicates the presence of a dangerous CO level. If the alarm sounds:

  1. Immediately move to fresh air outdoors or open all doors and windows to ventilate the area and allow the carbon monoxide gas to disperse. Stop using all fuel-burning appliances, if possible, and ensure they are turned off.
  2. Immediately inform all other people to evacuate to safe outdoor regions with fresh air and count heads. Ask for help from First-aid agencies by dialing or other means. Safely ventilate the house after First-aid personnel arrive to eliminate the dangerous source.
  3. Non-professional persons without oxygen supply and gas defense equipment shall not re-enter the dangerous regions before the alarm removes the alarm status.
  4. If the alarm continues to sound, evacuate the premises, alerting other occupants of the risk. Leave doors and windows open. Do not re-enter the premises.
  5. If someone is poisoned or suspected of having been poisoned by carbon monoxide, please turn to emergency medical institutions for help immediately.
  6. Telephone the appropriate appliance servicing and maintenance agency, and the relevant fuel supplier on their emergency number, so that the source of carbon monoxide emissions can be identified and corrected. Unless the reason for the alarm is obviously spurious, do not use the fuel-burning appliances again until they have been checked and cleared for use by a competent person according to national regulations.

6. Maintenance

To keep your CO detector in good working order, you must follow these simple steps:

  • Test the detector once a week by pressing the Test button.
  • Vacuum the detector cover once a month to remove accumulated dust. Use the soft brush attachment of your vacuum cleaner, and unplug the detector from the electrical outlet before vacuuming.
  • Instruct children never to touch, unplug, or otherwise interfere with the unit. Warn children of the dangers of CO poisoning.
  • Never use detergents or solvents to clean the detector. Chemicals can permanently damage or temporarily contaminate the sensor.
  • Avoid spraying air fresheners, hair spray, paint, or other aerosols near the CO detector.
  • Do not paint the CO detector. Paint will seal the vents and interfere with proper sensor operation.
  • Do not mount the CO detector directly above or near a diaper pail, as high amounts of methane gas can cause temporary readings on the digital display.

7. Troubleshooting

Refer to the 'LCD Display and Indicators' table in the Operating Instructions section for specific error codes and their meanings. Common issues and their solutions include:

  • 'Lb' displayed (Low Battery): Replace all three AA batteries immediately.
  • 'Err' displayed (Malfunction): The unit is in malfunction status. It needs to be repaired or replaced immediately.
  • 'HHH' displayed (High CO Concentration): This indicates CO levels over 999 ppm. MOVE TO FRESH AIR IMMEDIATELY!!!
  • 'End' displayed (End of Life): The unit has reached the end of its operational life (approx. 10 years from first power-on). Replace the unit immediately.
  • Alarm sounds continuously: Follow the steps in 'What to Do When Alarm Sounds' immediately.

8. Warranty & Support

Thank you very much for choosing our products. Usually, after-sales service will follow the warranty policy of the sales platform. For a 24-month non-artificial damage warranty, you can contact us via the email provided below. For any issues, please feel free to contact us.

During the specified warranty period, we will repair or replace, at our discretion, any defective carbon monoxide detector that is returned to the retailer.

Please include your name, address, and order number along with a brief description of what is wrong with the unit.

Email: info@cpvans.com (UK)

Email: support2@cpvans.com (EU)

9. Product Video

Video: This video demonstrates the key features and installation process of the CHZHVAN 2-in-1 Smoke and Carbon Monoxide Detector, including its dual detection capabilities, easy setup, and alarm functions.