1. Product Overview
The Aideepen CNC Adjustable Direct Current Stabilized Voltage Power Supply is a versatile module designed for precise voltage and current control. It features a full-view 1.8-inch high-brightness true color LCD screen, supports independent color matching, and four-way rotation for optimal viewing. The product is equipped with comprehensive protection mechanisms including input anti-reverse protection and output anti-backflow protection.
Key Features
- Supports firmware upgrade.
- MPPT solar charging capability.
- Serial communication support.
- Full view 1.8-inch high brightness true color LCD screen.
- Independent color matching and four-way display rotation.
- Input anti-reverse protection.
- Output anti-backflow protection.
- Gold-plated display panel for oxidation resistance and better conductivity.
- Intelligent temperature control PWM infinite speed control fan for low noise and long lifespan.
- Large area heat sink for efficient cooling.
Cooling System
The module features an optimized dual-fan thermal architecture with dual-core powered, full-coverage cooling. Dual intelligent temperature-controlled fans ensure low noise, high lifespan, collaborative operation, and stable performance.

One fan focuses on "point-to-point" cooling of high-heat components (MOSFETs, inductors, etc.), while the other optimizes heat dissipation across the entire heatsink to prevent thermal accumulation. This design ensures high efficiency, stability, and enhanced performance, reducing temperature by 20-30% (based on typical test data), extending product lifespan, and supporting continuous full-power operation in high-load scenarios.
2. Setup Instructions
Component Identification
The power supply module consists of a main board and a separate control panel. The control panel connects to the main board via a multi-wire cable.


Initial Connection
- Ensure the unit is OFF before connecting any external components.
- Connect the control panel to the main board using the provided cable.
- Connect your input power source to the IN+ and IN- terminals on the main board.
- Connect your load to the OUT+ and OUT- terminals.
- For MPPT solar charging, connect the solar panel and battery as shown in Figure 4.
- Attach the external temperature probe (if used) to the battery and the NTC temperature probe interface on the main board.
Precaution: Ensure the unit is OFF before connecting the battery. Avoid reverse polarity connection to prevent device damage or fire hazards. Turn on the output ONLY after the battery icon appears on the screen to initiate charging.
Bare Board Configuration (DIP Switches)
When purchasing the bare device, switches, potentiometers, and dial switches are pre-welded. If a set with a screen meter is purchased, they are not welded by default.

The DIP switches allow for setting the constant current value. Flip the switch up to light up the green indicator light, entering the potentiometer mode. Conversely, it operates in the digital control meter mode.
| Current (A) | DIP Switch Configuration |
|---|---|
| 1.0A | ... |
| 2.5A | ... |
| 5A | ... |
| 8A | ... |
| 10A | ... |
| 12A | ... |
| 15A | ... |
| 18A | ... |
| 20A | ... |
| 25A | ... |
| 30A | ... |
| 35A | ... |
| 40A | ... |
| 45A | ... |
| 48A | ... |
| 50A | ... |
The advantage of setting the constant current value through the DIP switch is that it eliminates the need to use a multimeter's current range for measurement, thereby avoiding the potential burnout of the multimeter due to insufficient range of most multimeters' 10A gear.
MPPT Solar Charging Setup
The power supply supports MPPT solar charging with automatic stop when fully charged and automatic charging at low battery, enabling intelligent battery charging management.

An external temperature probe can be connected, supporting over-temperature protection. Attach the external temperature probe to the battery, and it will automatically stop charging in case of over-temperature. The unit also features BCH automatic charging and BTF full-charge auto-stop function, enabling unattended operation.
3. Operating Instructions
Control Panel Overview
The control panel features a 1.8-inch LCD screen displaying voltage, current, power, temperature, and various status indicators. It includes V-SET, SW, I-SET buttons, an encoder knob, and an ON/OFF power button.

Button Functions
- V-SET Button: Short Press to set voltage (CV). Long Press to quickly call up data set M1.
- SW Button: Short Press to enter quick settings. Long Press to enable four-way screen rotation.
- I-SET Button: Short Press to set current (CC). Long Press to enter or exit the data group settings UI.
- Encoder Button: Short Press to shift. Long Press to lock the button.
- Power Button: Short Press to turn power output on/off. Long Press to shut down.
Setting Voltage and Current
There are three ways to set voltage and current:
Quick Setup Mode
- Press the V-SET/I-SET button briefly to enter voltage/current setting mode.
- Use the SW button or encoder button to move between digits.
- Rotate the encoder to adjust the voltage/current value. Once set, press V-SET/I-SET briefly to save and exit.
Encoder Mode
- Press the encoder button briefly to activate the parameter (voltage/current) you want to set.
- Press the encoder button to switch between full selection (all digits highlighted) and digit selection (selected digit highlighted). Rotate the encoder to switch between setting voltage or current, and to adjust the value in digit selection.
- To finish, either hold the encoder button/SW button for 2 seconds or wait 6 seconds without any button press. All settings are saved automatically.
Operating Modes (CV, CC, CW)
The power supply operates in Constant Voltage (CV), Constant Current (CC), and Constant Power (CW) modes.
| Mode | Description |
|---|---|
| CV (Constant Voltage) & CC (Constant Current) | When the constant power function is not turned on, the power supply only has the functions of constant voltage (CV) and constant current (CC), which automatically switch based on the load. If the load current is less than the set constant current value, the power supply is in constant voltage mode, where the output voltage is the set voltage value CV, and the current is adaptive. |
| CW (Constant Power) | After the constant power function is turned on, the constant current value defaults to the maximum value, and the constant voltage value CV serves as the initial voltage (set to a reasonable value based on actual conditions). After the power supply is turned on, the equivalent resistance R of the load is calculated using Ohm's law R=U/I. Then, the corresponding voltage can be calculated based on the set constant power value using the power formula P=U/R. At this point, the constant power point algorithm automatically follows, and the constant power is achieved. |
Constant Power Switch and Constant Power Value Setting
- In the system parameter settings UI, select the CW option. Turn ON to enable constant power, and turn OFF to disable constant power.
- After enabling constant power, press ISET briefly on the main interface to modify the value of constant power.
Data Set Management
Quick Recall Data Sets
Hold the V-SET button to quickly load the M1 data set. To select other data sets, hold the I-SET button to open the data set selection window. Rotate the encoder to choose the desired data set. Then, either hold I-SET or briefly press the SW/encoder button to load the selected data set. The interface will show the currently loaded data set.
System Parameters
Adjusting System Parameters
On the main screen, briefly press the SW button to select a status bar parameter. Rotate the encoder to switch between parameters. Briefly press the SW button or encoder button to adjust the parameter or open the parameter setting interface. Use the encoder to set the value. To save and exit, either hold the SW button/encoder button or wait 6 seconds without any button press. All settings are saved automatically.
Display Customization and Rotation
The display supports 8 color options, allowing you to freely customize the interface colors. Long press the SW button on the main UI to enable four-way rotation, allowing you to read test data from any angle.


Remote Control Operation
The power supply supports control via an infrared remote control numeric keypad, providing convenience and speed. It works with both Infrared and 433M Wireless Remote Control Modules.
The video demonstrates:
- Short pressing SW to shift and using the power key for on/off.
- Smooth operation of the encoder.
- Setting voltage and observing voltage accuracy.
- Setting current and observing current accuracy.
- Resetting capacity, energy, and runtime.
- Navigating the data set parameters interface.
- Navigating the system parameters interface.
- Quickly recalling data sets.
- Using right status bar shortcuts.
- Remote control operation using a dedicated remote.
- Using short press shift + number keys on the remote to quickly recall data sets.
Advanced Communication and Control
Multi-Serial Port Host Software
A complete set of complementary commercial software is available for use. This multi-serial port host software supports communication with up to 247 devices via a single serial port, enabling control of over a thousand devices in a clustered environment. It allows for batch control of all devices under a specific account, including voltage, current, switches, and other parameters, improving efficiency through simultaneous manipulation of multiple devices. Management accounts can be added for secure and controlled access to settings.

Group Control
The digital control panel supports one-to-many group control. By turning on the group control switch on the panel and using the 485 bus, you can collectively manage power supply activation/deactivation, voltage/current settings, achieving one-to-many control with simplicity and efficiency.

To activate the Group Control Function: On the main power supply interface, briefly press the SW button to select the right status bar. Rotate the encoder to choose, then briefly press the encoder button to open the selection dialog. Press the SW or encoder button to select and rotate the encoder to ON to enable group control mode. When setting voltage, current, or power on/off, the changes will automatically synchronize to all devices on the 485 bus (Note: Device addresses on the bus must be unique). Hold the SW button or wait 6 seconds without operation to exit and save settings automatically.
Network Control
The device supports network control anytime, anywhere, through LAN penetration and real-time communication. Remote control via an external network is possible, offering unlimited distance control. It also supports email notifications and cloud record keeping.

Firmware Upgrade
The power supply supports firmware upgrades to experience new features. Currently, it supports firmware upgrades through the WiFi module. Future updates will enable upgrades through the multi-serial port host computer software.

4. Maintenance
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Ensure proper ventilation around the module to allow the cooling fans to operate effectively.
- Avoid exposing the device to extreme temperatures or humidity.
- The gold-plated design of the display panel is resistant to oxidation and offers good durability.
5. Troubleshooting
Protection Mechanisms
The power supply is designed with multiple protection features to ensure safety and prevent damage:
- LVP (Input Under-Voltage Protection): Default 10V.
- OVP (Over-Voltage Protection): Default 67.00V.
- OCP (Over-Current Protection): Default 32A.
- OPP (Over-Power Protection): Default 2000W.
- OTP (Over-Temperature Protection): Default 110°C.
- OHP (Over-Time Out Protection): 1 minute - 99 hours 59 minutes, off by default.
- OAH (Over-Capacity Protection): 0-4200KAh, off by default.
- OWH (Over-Energy Protection): 0-4200KWh, off by default.
- ETP (External Over-Temperature Protection): 0-110°C, off by default.
- Reverse Polarity Protection: For input.
- Reverse Current Protection: For output.
If any of these protections are triggered, the device will typically shut down or limit output to prevent damage. Check the input, output, and load conditions to resolve the issue.
Firmware Upgrade Issues
Note: Do not power off during the product upgrade process.
If a product upgrade fails, you can press and hold the power button to power on the product and force it into the upgrade mode for recovery.
6. Technical Specifications
| Parameter | XY6530S | XY6550S |
|---|---|---|
| Product Name | CNC DC step-down power supply | |
| Input Voltage | 12.00~75.00V | 12.00~70.0V |
| Output Voltage | 0~65.00V | |
| Output Current | 0~30.00A | 0~50.00A |
| Power Output | 2000W | 3250W |
| Voltage Resolution | 0.01V | |
| Current Resolution | 0.01A | |
| Voltage Accuracy | ±0.5%+1 word | |
| Current Accuracy | ±0.5%+3 word | |
| Storage Data Group | 10 groups | |
| Soft Start | Yes | |
| Screen Size | 1.8-Inch Full-View High-Brightness True Color LCD | |
| Output Ripple Typical Value | vpp-200mv | |
| MPPT Function | Support MPPT solar charging | |
| Buzzer | Yes | |
| Efficiency of Conversion | Around 95% | |
| Number of Buttons | 5 | |
| Protection | Value / Default |
|---|---|
| Anti-reverse | Yes |
| Output Reverse Current Protection | Yes |
| Input Under-Voltage (LVP) | 10-75.00V, default 10V |
| Over-Voltage (OVP) | 0-67.00V, default 67.00V |
| Over-Current (OCP) | 0-32A, default 32A |
| Over-Power (OPP) | 0-2100W, default 2000W |
| Over-Temperature (OTP) | 60-110°C, default 110°C |
| Over-Time Out (OHP) | 1 minute - 99 hours 59 minutes, off by default |
| Over-Capacity (OAH) | 0-4200KAh, off by default |
| Over-Energy (OWH) | 0-4200KWh, off by default |
| EXT Over-Temp (ETP) | 0-110°C, off by default |
Dimensions and Weight

| Component | Dimensions (L*W*H) | Weight |
|---|---|---|
| Screen Instrument | 86*45*28mm | N/A |
| Bare Board Size | 126*85.5*43mm | N/A |
| Bare Board Weight (with packaging) | N/A | 330g |
| Product Weight (with packaging) | N/A | 425g |
| Single-unit packaging | 170*134*52mm | N/A |
| Full-set packaging | 245*122*75mm | N/A |
7. User Tips
- Low Voltage Output: The power supply is capable of reaching very low voltages, down to 0.01V resolution, making it suitable for applications requiring precise low voltage output.
- Remote Control Convenience: Utilize the remote control feature for convenient adjustments, especially when the module is installed in a hard-to-reach location.
- Group Control for Multiple Units: For projects requiring multiple power supplies, leverage the 485 bus group control function to manage all units simultaneously from a single interface.
8. Support and Documentation
For more detailed information, including comprehensive wiring diagrams and advanced usage scenarios, please refer to the official user manual PDF available at: User Manual (PDF).