MESTEK EMF02R

Contents

MESTEK EMF02R EMF Meter User Manual

High Frequency Electromagnetic Radiation Detection Three-axis Radiometer

1. Introduction

The MESTEK EMF02R is a digital high-frequency electromagnetic signal measurement instrument designed for accurate detection of magnetic field radiation, electric field radiation, and high-frequency radiation in various environments. It features a conventional detection method with a digital display, making it suitable for industrial equipment, high-speed rail applications, and general high-frequency signal measurement.

MESTEK EMF02R EMF Meter showing its display and features
The MESTEK EMF02R EMF Meter, highlighting its triaxial detection, Max/Avg/Hold functions, and measurement capabilities for RF, E-field, and H-field.

2. Safety Information

Please read the following safety information carefully before using or maintaining the instrument to ensure safe and proper operation.

  • Always use the instrument according to the instructions provided in this manual.
  • Store the instrument in a dry environment. Before use, check for any signs of damage.
  • Ensure the instrument is stored within the specified temperature and humidity ranges.
  • If you observe any anomaly or damage during use, immediately stop using the instrument.
  • Avoid storing or using the instrument in direct sunlight, high temperatures, or humid environments.
  • When cleaning, use a clean and soft cloth. Do not use corrosive solvents or abrasive materials.
  • During measurement, keep a safe distance from three-phase contactors or high-voltage equipment to prevent electric shock.

3. Package Contents

The standard package for the EMF02R EMF Meter includes the following items:

  • High-frequency radiation detector (EMF02R unit)
  • USB Type-C charging cable
  • Product manual (this document and a printed version)
  • Cloth bag for storage
  • Packaging box
Contents of the EMF Meter package including the device, cable, manual, and bag
Illustration of the product accessories included in the package.

4. Product Overview and Controls

Familiarize yourself with the different parts and controls of your EMF02R meter:

Diagram of the EMF Meter with labeled parts and dimensions
Labeled diagram of the EMF02R meter, showing its components and dimensions.

Key Components:

  • Induction Probe: Located at the top, this is the primary sensor for detecting electromagnetic fields.
  • Display Screen: A VA reverse display color screen that shows measurement readings, units, battery status, and other indicators. It offers a high-definition digital and analog dual display.
  • Function Keys: A set of buttons for controlling the device's functions.
  • Charging Indicator Light: Indicates the charging status of the device.
  • Type-C Charging Port: Located at the bottom for connecting the USB Type-C charging cable.

Function Keys:

  • Power Button (⑁): Long press to turn the unit on or off.
  • SEL Button: Function selection key. Short press to cycle through E-field and H-field measurement modes.
  • AVG/MAX Button: Short press to switch between Average (AVG) and Maximum (MAX) value display. Press again to cancel.
  • HOLD Button: Short press to lock (hold) or unlock the current data on the display.
  • RF Button: Short press to enter the High-Frequency (RF) signal radiation measurement mode.
Close-up of the EMF Meter's VA reverse display color screen
The VA reverse display color screen provides clear digital and analog readings.

5. Setup

5.1 Charging the Device

The EMF02R is powered by a built-in 18650/2000mAh/3.7V lithium battery. Before first use or after a long period of inactivity, ensure the device is fully charged.

  • Connect the provided USB Type-C charging cable to the device's Type-C port and a 5V/1A power adapter (not included).
  • Charge the device in a well-ventilated area with good heat dissipation.
  • The charging indicator light will be red during charging.
  • Charging typically takes approximately 4 hours for a full charge.
  • Once fully charged, the indicator light will turn green.
  • Use only the original charger and avoid overcharging.
EMF Meter connected to a charger via USB Type-C cable
The EMF Meter charging via its USB Type-C port, showing the charging indicator status.

6. Operation

6.1 Power On/Off

Long press the Power Button (⑁) to turn the unit on or off.

6.2 Measurement Modes

The EMF02R supports three measurement modes: High-Frequency (RF), Electric Field (E-field), and Magnetic Field (H-field).

  • RF Measurement: Short press the RF Button to enter RF mode. The display will show 'RF'. This mode measures high-frequency signal radiation from 30MHz to 8GHz, typically from sources like base stations.
  • E-field Measurement: Short press the SEL Button to enter E-field mode. The display will show 'E-field'. This mode measures the electric field radiation value of electrical equipment.
  • H-field Measurement: Short press the SEL Button again to enter H-field mode. The display will show 'H-field'. This mode measures the electromagnetic field radiation. Short press SEL again to cycle through magnetic field radiation measurement units (uT/mG).

6.3 Data Hold (HOLD)

To freeze the current reading on the display, short press the HOLD Button. Press it again to release the data hold function and resume real-time measurements.

6.4 Average (AVG) / Maximum (MAX) Measurement

Short press the AVG/MAX Button to toggle between displaying the average (AVG) and maximum (MAX) measured values. Press it again to cancel this function and return to real-time display.

6.5 Unit Selection (Temperature)

Long press the Power Button (⑁) while the device is off, then release when the screen lights up, to select between Celsius (°C) and Fahrenheit (°F) for temperature display.

6.6 Automatic Shutdown Function

The device has an automatic shutdown feature to conserve battery. To cancel this function:

  1. With the unit turned off, press and hold both the HOLD Button and the Power Button (⑁) simultaneously.
  2. Release the buttons when the screen lights up.
  3. The automatic shutdown symbol (usually in the upper left corner) will disappear, indicating the function is canceled.
  4. To restore the automatic shutdown function, restart the device after a manual shutdown.

6.7 Radiation Alarm

To check for radiation sources, hold the instrument and slowly move the probe closer to a suspected source. When the measured value on the screen and the analog display reach the yellow area, the instrument will emit an audible alarm. If the radiation level exceeds safe standards, it is recommended to stop measuring or move away from the radiation source.

7. Maintenance

7.1 Cleaning

To clean the instrument, use a clean and soft cloth. Do not use corrosive solvents or abrasive materials, as these can damage the device's surface or internal components.

7.2 Battery Care

To prolong battery life, always use the original charging cable and adapter. Avoid overcharging the device. If the instrument will not be used for an extended period, ensure it is fully charged before storage and recharge it periodically.

8. Troubleshooting

  • Device not turning on: Ensure the battery is charged. Connect to a charger and check the charging indicator light.
  • Inaccurate readings: Ensure the device is held correctly and the probe is pointed towards the radiation source. Avoid interference from other electronic devices.
  • No H-field reading for static magnetic fields: The H-field measurement requires movement between the tool and the magnetic source. It does not measure static magnetic fields when both are stationary.
  • Alarm sounds frequently: The device is sensitive and may alarm near common household appliances like refrigerators and rice cookers. This indicates the presence of electromagnetic fields. If concerned, maintain distance from such sources.
  • Device anomaly or damage: If the instrument shows any unusual behavior or physical damage, discontinue use immediately and contact support.

9. Specifications

Parameter Value
Operation Altitude <2000m
Magnetic Field Range 0.01-199.9uT (0.1-1999mG)
Electric Field Range 1-1999V/m
RF Field Range 0.01-19.99mW/cm² (0.01-199.9V/m, 0.01-99.99mW/m²)
Magnetic Field Accuracy 0.01uT/0.1mG
Electric Field Accuracy 1V/m
RF Field Accuracy 0.01mW/cm²
Sampling Rate About 0.4 seconds
Measurement Bandwidth 30MHz-8GHz
Power Supply 18650/2000mA Lithium Battery
Charging 5V/1A Type-C
Axial Detection Triaxial
Operating Temperature -10°C to 60°C (14°F to 140°F)
Operating Humidity 0-99% RH

10. User Tips

  • The EMF02R is generally considered easy to use and provides clear readings.
  • For H-field measurements, remember that the tool or the magnetic source needs to be in motion relative to each other for detection; it does not measure static magnetic fields when both are stationary.
  • The device is sensitive and will display measurements when close to common household appliances like refrigerators and electric rice cookers, indicating their electromagnetic emissions.
  • The meter has a high-quality feel, fits well in hand due to rubberized side parts, and features an easy-to-read display.

11. Warranty and Support

For detailed warranty information, technical support, or service inquiries, please refer to the official product documentation or contact the seller directly. A comprehensive user manual in PDF format is available for download and further reference:

Download Full User Manual (PDF)

© 2024 MESTEK. All rights reserved.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.