1. Introduction
The YAXUN YX-3010AD Pro is a versatile 3-in-1 intelligent regulated DC power supply, multimeter, and PD60W charger. It features a 4.0-inch LCD display, offering precise control and monitoring for various electronic applications. This manual provides essential information for safe and effective operation of your device.

Figure 1: YAXUN YX-3010AD Pro with highlighted features
2. Safety Guidelines
Please read and understand these safety guidelines before operating the device to prevent damage or injury.
- Ventilation: Do not block or obstruct the air intake vents and fan ventilation ports of the power supply. Ensure adequate airflow around the unit.
- Handling: Avoid severe collisions or improper handling to prevent damage to the machine.
- Static Electricity: Keep the machine away from static electricity.
- High Voltage: High voltage is present inside the device. Disassembly is strictly prohibited for non-professionals. Only authorized service personnel should open the casing.
- Grounding: Connect the protective grounding wire to the earth to avoid electric shock.
- Fuse Replacement: Always disconnect the power cord before replacing the fuse to prevent electric shock.
3. Setup
3.1 Initial Power-On Check
Before powering on the device for the first time, carefully check the label located below the AC power input socket on the back of the power supply. Ensure that the operating voltage (110V or 220V) specified on the label matches the AC voltage of your local environment. If the voltages do not match, do not power on the device and contact the seller for assistance to avoid damage.

Figure 2: Rear view with power input socket
3.2 Product Overview
Familiarize yourself with the main components and interfaces of the YX-3010AD Pro.

Figure 3: Product overview highlighting key features
4. Power Supply Panel Function Description
The front panel of the YX-3010AD Pro features a high-definition LCD display and various controls and ports:

Figure 4: Front Panel Layout
- High-Definition LCD Display: Shows all operational parameters and menu interfaces.
- μA/mA Switching: Button to switch between microampere and milliampere display.
- Function Keys (M1-M5): Corresponding to the menu options displayed on the screen.
- OUT/EN (DC Output One-touch On/Off): Button to enable or disable DC output.
- Voltage Adjustment Knob (VOL.): Rotates to adjust output voltage. Press to switch adjustment speed.
- Current Adjustment Knob (CUR.): Rotates to set output current limit.
- QC3.0 Charging Interface: Fast charging port.
- PD60W / PD24W Charging Interfaces: Fast charging ports.
- PC/Software Upgrade Interface: USB port for software upgrades.
- Battery Boot Power (0-8.4V): Power-on line output interface supporting adjustable voltage limit.
- Main Power Input Switch: Turns the device on/off.
- Multimeter Wire Interface (COM, VΩ): Ports for connecting multimeter probes.
- DC Output Banana Jack Interface: Red and black banana jacks for DC power output.
- Ground Wire Interface: For connecting to earth ground.
5. Operating Instructions
5.1 Voltage Adjustment
Rotate the Voltage (VOL.) knob directly to adjust the output voltage. The current voltage value is displayed on the screen. Press the knob once to toggle the voltage adjustment speed between 0.1V and 0.5V increments.
5.2 Current Adjustment
Rotate the Current (CUR.) knob directly to set the output current limit. The configured current limit value is displayed on the screen.
5.3 Lock/Unlock Function
- Voltage Lock: Long-press the Voltage knob to lock the voltage adjustment function, preventing accidental changes.
- Current Lock: Long-press the Current knob to lock the current adjustment function, preventing accidental changes.
5.4 Memory Storage Channels
The device has 4 memory channels (M1-M4) for storing voltage and current settings. Pressing the corresponding button (M1-M4) will instantly output the preset values. Long-pressing a button will save the currently output voltage and current settings to that channel.
5.5 Adjustable USB Output
Primarily used for charging mobile phones, the maximum output voltage (adjustable between 0~8.4V) can be set in the configuration parameters to define the highest output voltage value.
5.6 Charging Detection Ports
The three fast charging ports (QC3.0, PD60W, and PD25W) allow you to monitor the corresponding charging voltage and current on the display screen to confirm fast charging activation.

Figure 5: Fast Charging Test Port Description
5.7 Continuous Overcurrent Protection
The device can be set to either constant voltage (CV) or constant current (CC) mode. In constant voltage mode, if the current exceeds the set limit, the output will automatically shut off and reset to protect the connected device.
5.8 Functional Interface Selection and Operation
Rotate either the Voltage or Current knob to navigate through the function options on the main menu. After selecting the desired function, press any of the M1-M5 buttons to enter the respective interface.

Figure 6: Functional Interface Selection
5.9 Configuration Interface Selection and Operation
Parameters can be configured via the buttons or knobs. The M1-M5 buttons correspond to the five functions displayed below the screen:
- M1: Save and Exit
- M2: Previous Item
- M3: Next Item
- M4: Previous Option
- M5: Next Option
Use the Voltage knob to navigate up or down through parameter items. Use the Current knob to modify the selected parameter. After making changes, press the M1 button to exit the interface.
5.10 Interface Parameter Descriptions
The display provides detailed information about the output and settings:

Figure 7: Fully Digital Meter Display
- Set Output Voltage and Current Limit: Displays the configured voltage and current limits.
- Voltage and Current Adjustment Step Value: Indicates the increment/decrement step for voltage and current.
- Voltage and Current Knob Lock Status: Shows if the knobs are locked.
- DC Output Status: Indicates if the DC output is active.
- Current mA/μA Sampling Status: Shows the current measurement range.
- Real-Time Output Voltage, Current, and Power Values: Displays live output readings.
- QC/PD1/PD2 Fast Charging Interfaces: Shows charging voltage and current for connected devices.
- Multimeter Function Numerical Display (M5): Toggles the multimeter function.
5.11 Full Waveform Description
The device can display full waveform data. Press the corresponding button to start or pause waveform sampling. After pausing, rotate either knob to review the sampled waveform data.

Figure 8: Full Waveform Display
5.12 Power Meter Description
In the power meter interface, the charging capacity of the corresponding port is automatically recorded. Press the corresponding button below to reset the power measurement value for that port and restart the calculation.
5.13 Analog Meter Display Description
The analog meter provides a visual representation of the DC output current. Briefly press the current adjustment knob (M4) to change the meter's measurement range.

Figure 9: Analog Meter Display
5.14 Multifunctional Test Meter Description
The device includes a built-in multimeter function. A green indicator light illuminates at the top after selecting a function. The multimeter offers the following measurement capabilities:
- M2: Voltage measurement (DC -24V to DC 36V).
- M3: Resistance measurement (0Ω to 2MΩ).
- M4: Continuity measurement (0Ω to 1KΩ).
- M5: Diode measurement (0 to 1600mV).
The continuity and diode measurement data recording function automatically overwrites after exceeding 32 sets, starting from 1. Press the corresponding function button to reset the data.
Video 1: Product demonstration showing charging a laptop, using the multimeter function, and powering a circuit board.
6. Maintenance
- Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Environment: Operate and store the device in a dry, well-ventilated area, away from direct sunlight, high temperatures, and static electricity.
- Ventilation: Ensure that the air intake and fan vents are not obstructed to prevent overheating.
- No User Serviceable Parts: Due to high voltage components, do not attempt to disassemble or repair the unit yourself. Refer all servicing to qualified personnel.
7. Troubleshooting
- No Power: Check the main power input switch and ensure the power cord is securely connected. Verify that the input voltage matches the device's requirements (110V or 220V).
- Output Shuts Off: If the device is in constant voltage mode and the current exceeds the set limit, the overcurrent protection will activate, shutting off the output. The output will reset automatically. Reduce the load or increase the current limit if appropriate.
- Voltage/Current Not Adjustable: Check if the voltage or current knobs are locked. Long-press the respective knob to unlock it.
- Incorrect Voltage Reading: Ensure proper calibration and correct connection of probes for multimeter functions.
8. Specifications
| Feature | Specification |
|---|---|
| Model | YX-3010AD Pro |
| Display Screen | 4.0-inch LCD screen |
| Dimensions | 230 x 129 x 194 mm |
| Weight | 4.3kg |
| Power Cord Length | 1.2m |
| Input Voltage | AC 110V 50/60Hz or AC 220V 50/60Hz |
| Output Voltage | 30V |
| Output Current | 10A |
| Power | 250W |
| Multimeter Function | DC voltage, Resistance, Continuity, Diode |
| Quick Charging Type | QC3.0/PD24W/PD60W |
9. User Tips
- Output State on Power-On: Be aware that the power supply may remember its last output state (ON/OFF) when powered on. Always verify the output status before connecting sensitive devices.
- Voltage Adjustment Precision: The voltage adjustment knob allows for increments of 0.1V or 0.5V. If finer adjustment (e.g., 0.01V) is needed, this device may not provide that level of precision.
10. Warranty and Support
For detailed warranty information, technical support, or further assistance, please refer to the comprehensive user manual available in PDF format. You can access the PDF manual here.
If you encounter any issues or have questions not covered in this manual, please contact the seller or manufacturer's support channel.