1. Product Overview

The Hersmann Temperature Sensor (Model QDL80A) is an advanced RTD (Resistance Temperature Detector) based transmitter designed for precise temperature measurement in various industrial applications. It converts the temperature detected by a Pt100 element into a standard electrical signal (e.g., 4-20mA, 0-10V, RS485) for seamless integration with automation equipment and control systems.

Hersmann Temperature Sensor main product image

Figure 1: Hersmann Temperature Sensor (QDL80A)

Working Principle

The temperature sensor, typically a Pt100 element, detects temperature changes. This analog signal is then processed by the transmitter's internal circuit, which includes amplification, filtering, and non-linear correction. The processed signal is converted into a standard output signal, such as 4-20mA current or 0-10V voltage, facilitating connection and communication with other automation equipment, control systems, and real-time temperature monitoring and control systems.

Features

  • High-precision Measurement: Utilizes high-precision temperature sensor elements like Pt100 or Pt1000, achieving measurement accuracy of ±0.2% FS.
  • Multiple Output Signals: Provides standard 4-20mA DC current signals or 0-10V DC voltage signals, which are linear with the measured temperature. RS485 output is also available.
  • Strong Anti-interference Ability: Employs a two-wire transmission system, ensuring long signal transmission distances with minimal distortion.
  • Strong Environmental Adaptability: Designed for stable operation within a wide temperature range of -10 °C to +80 °C.
  • Flexible Installation: Supports various mounting methods, including threaded, flange, or clamp mounting.
  • Customizable: Sensor length, diameter, measuring range, and thread specifications can be customized to meet specific user requirements.
  • High Protection Level: Generally rated up to IP65 (without display) or IP54 (with display), effectively preventing dust and water intrusion, suitable for harsh industrial environments.

Areas of Application

  • Petrochemical Industry: For temperature measurement of liquids, gases, and vapors.
  • Power Industry: For temperature monitoring in power plants to ensure safety and efficiency.
  • Food Industry: For temperature monitoring during food processing to ensure quality and safety.
  • Pharmaceutical Industry: For temperature control to ensure drug quality and production process stability.
  • Mechanical Engineering: For temperature detection in engines, compressors, and bearings.
  • Refrigeration Units: For temperature monitoring and control in refrigeration systems.
  • Shipbuilding Industry: For monitoring ship equipment temperature.
  • Heating Industry: For temperature measurement in heating processes and system control.

2. Specifications

Parameter Value
Model QD-HD
Supply Power DC24V
Measuring Range -200~600°C
Accuracy ±0.2%F.S
Output Signal 4-20mA (Default), 0-10V, 0-5V, RS485
Material SS304
Temperature Measuring Element PT100
Probe Diameter 6mm (Default)
Probe Length 100mm (Customized options: 30mm, 50mm, 60mm, 80mm)
Stability ±0.1%F.S/Year
Work Temperature -40~80°C
Protection Rating IP65
Power Consumption ≤0.05W

Dimensions

The sensor features a probe diameter of 6mm (default) and a default length of 100mm, with customizable options including 30mm, 50mm, 60mm, and 80mm. The thread size is M20*1.5 by default, with G1/2 and G1/4 options available. The overall dimensions are approximately 95mm (total length including connector) x 58mm (body length) x 18mm (connector width). The probe extends from the threaded base.

Hersmann Temperature Sensor side view

Figure 2: Side view of the sensor, showing probe and connector.

3. Setup and Installation

Before installation, ensure the power supply is disconnected. Choose a mounting location that provides accurate temperature readings and is easily accessible for maintenance. The sensor supports various mounting methods, including threaded, flange, or clamp mounting, depending on your application's requirements.

Video 1: Product overview and handling demonstration.

Wiring Instructions

The sensor supports 2-wire, 3-wire, and 4-wire configurations. Ensure correct polarity and connection to avoid damage to the sensor or connected equipment. Refer to the specific wiring diagram for your chosen output signal type.

2-Wire Connection (e.g., 4-20mA output)

  • Pin 1: Red (V+) - Power Supply Positive
  • Pin 2: Blue (OUT) - Signal Output
  • Connect the power supply (DC24V) to V+ and the signal input of your device to OUT.

3-Wire Connection (e.g., 0-10V output)

  • Pin 1: Red (V+) - Power Supply Positive
  • Pin 2: Blue (GND) - Ground
  • Pin 3: Yellow (OUT) - Signal Output
  • Connect the power supply (DC24V) to V+ and GND. Connect the signal input of your device to OUT and GND.

4-Wire Connection (e.g., RS485 output)

  • Pin 1: Red (V+) - Power Supply Positive
  • Pin 2: Blue (V-) - Power Supply Negative (Ground)
  • Pin 3: Yellow (A) - RS485 Data A
  • Pin 4: White (B) - RS485 Data B
  • Connect the power supply (DC24V) to V+ and V-. Connect the RS485 data lines A and B to your communication device.

Note: Always verify the specific pinout on your sensor's label or the detailed PDF manual for precise connections, as variations may exist.

4. Operating Instructions

Once installed and wired correctly, the Hersmann Temperature Sensor will continuously measure temperature and output the corresponding signal. Ensure your receiving equipment (PLC, display, data logger, etc.) is configured to interpret the chosen output signal (4-20mA, 0-10V, or RS485) correctly within the specified measuring range.

  • Power On: Apply DC24V power to the sensor.
  • Signal Monitoring: Monitor the output signal on your connected device. For 4-20mA, 4mA typically corresponds to the lower end of the measuring range and 20mA to the upper end. For 0-10V, 0V corresponds to the lower end and 10V to the upper end. RS485 communication requires appropriate software and protocol configuration.
  • Environmental Considerations: While the sensor is robust, avoid exposing it to temperatures outside its specified operating range (-40~80°C) or to excessive vibration or mechanical stress.

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your temperature sensor.

  • Cleaning: Periodically clean the sensor probe to prevent buildup of contaminants that could affect accuracy. Use a soft cloth and appropriate cleaning agents for the material (SS304).
  • Inspection: Visually inspect the sensor and wiring for any signs of damage, corrosion, or loose connections.
  • Calibration: For critical applications, periodic calibration by a qualified technician is recommended to maintain measurement accuracy.
  • Environmental Protection: Ensure the IP65/IP54 rating is maintained by keeping the connector sealed and free from moisture and dust.

6. Troubleshooting

If you encounter issues with your temperature sensor, consider the following common troubleshooting steps:

  • No Output Signal:
    • Check power supply: Ensure DC24V is correctly applied and stable.
    • Verify wiring: Confirm all connections are secure and match the correct wiring diagram for your output type.
    • Inspect for damage: Look for any visible damage to the sensor or cables.
  • Inaccurate Readings:
    • Check sensor placement: Ensure the probe is fully immersed in the medium being measured and not affected by external heat sources/sinks.
    • Clean probe: Remove any buildup on the probe surface.
    • Consider recalibration: If readings are consistently off, the sensor may require calibration.
  • Intermittent Signal:
    • Check for loose connections: Tighten all wiring terminals.
    • Inspect cabling: Look for damaged or frayed cables.
    • Check for electrical interference: Ensure the sensor and wiring are not near strong electromagnetic fields.

For persistent issues, consult the detailed PDF manual or contact technical support.

7. User Tips

  • For applications requiring high accuracy, consider using a 4-wire Pt100 configuration if your system supports it, as it minimizes lead wire resistance errors.
  • When customizing probe length, ensure it is sufficient to reach the desired measurement point within the process.
  • Always use appropriate thread sealant or gaskets when installing the sensor to ensure a leak-proof and secure connection, especially in pressurized systems.
  • If using RS485 communication, ensure the correct communication protocol (e.g., Modbus RTU) and address settings are configured on both the sensor and the master device.

8. Warranty and Support

For detailed warranty information, technical support, or to access the full user manual in PDF format, please refer to the official product documentation or contact the manufacturer directly. The PDF manual provides comprehensive details on installation, operation, and advanced configurations.

A detailed user manual (PDF) is available for download: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.