1. Introduction
Thank you for purchasing the Tahlitech IPC-9800CLMOVTADHS Pro IP camera tester. This manual provides detailed instructions for the proper and safe use of the device. Please read it thoroughly before operation.
The Tahlitech IPC-9800CLMOVTADHS Pro is a 7-inch touch screen IP camera monitor designed for comprehensive maintenance and installation of various camera types, including IP cameras, analog cameras, 8MP TVI, 8MP CVI, 8MP AHD, and 8MP EX-SDI cameras. It supports 4K H.264 / 8K H.265 camera testing via mainstream, offering a 1280x800 resolution for high-definition display. The unit features extensive ONVIF PTZ and analog PTZ control capabilities, combining a touch screen with physical buttons for user-friendly operation.
Beyond camera testing, it serves as a robust tool for Ethernet network diagnostics, including PoE power voltage testing, PING, and IP address searching. A blue cable tracer is included to identify individual cables within a bundle, and it can test LAN cables for proper connection termination. Additional functionalities include 30W PoE power output, HDMI IN and OUT, CVBS loop test, simultaneous IP and analog testing, LED flashlight, DC 12V 3A, DC 24V 2A power output, and more. Its portability, intuitive design, and diverse features make it an indispensable tool for installers and technicians.

2. Safety Information
WARNING!
- The tester must be used in compliance with local electrical regulations. Avoid use in environments unsuitable for electrical devices, such as hospitals or gas stations.
- To prevent functional decline or failure, do not sprinkle or dampen the product.
- Do not touch exposed parts of the tester with dust or liquid.
- Avoid violent collision and vibration during transportation and use to prevent damage.
- Do not leave the tester unattended while charging. If the battery becomes severely hot, immediately disconnect the power source. Do not charge for more than 8 hours.
- Do not use the tester in high humidity environments. If the tester becomes damp, power it off immediately and disconnect all connected cables.
- Do not use the tester in environments with flammable gas.
- Do not disassemble the instrument. Internal components cannot be repaired by the user. If disassembly is necessary, contact the technical department.
- Do not use the instrument in environments with strong electromagnetic interference.
- Do not touch the tester with wet hands or watery objects.
- Clean the tester with a soft, dry cloth. For stubborn dirt, a soft cloth dampened with water or neutral detergent (well-tweaked) can be used.
2.1 Digital Multi-meter Safety
- Before use, select the correct input jack, function, and range.
- Never exceed the protection limit values specified for each measurement range.
- When the tester is connected to a measurement circuit, do not touch unused terminals.
- Do not measure voltage if the voltage on the terminals exceeds 660V above earth ground.
- For manual range, if the value to be measured is unknown, set the range selector to the highest position.
- Exercise caution when working with voltages above 60V DC or 40V AC; keep fingers behind the probe barriers.
- Never connect the meter to any voltage source when the function switch is in current, resistance, capacitance, or diode/continuity mode, as this will damage the meter.
- Never perform capacitance measurements unless the capacitor has been fully discharged.
- Never measure resistance, capacitance, diode, or continuity on live circuits.
2.2 Visual Laser Sources Safety
- When visual laser sources are on, do not stare directly at them to avoid eye damage.
- When not in use, turn off the laser and cover the protective cap.
3. Packing List
The standard package for the IPC-9800CLMOVTADHS Pro includes the following items:
- Tester
- Adaptor DC15V 1.6A
- Network cable tester
- Lithium ion battery (11.1V DC 5200mAh)
- BNC cable
- RS485 cable
- SC, ST connector (Only for optical power meter)
- Multi-meter test leads (one pair red and black, only for Multi-meter models)
- Output Power cable
- Audio cable
- TDR alligator clamp (only for TDR models)
- 8GB TF card
- Safety cord
- Tool bag
- Manual

4. Function Interface
The IPC-9800CLMOVTADHS Pro features a comprehensive set of interfaces and controls. Familiarize yourself with these components for effective operation.

4.1 Top Interface
| No. | Interface | Description |
|---|---|---|
| 21 | VFL | Visible red laser source emits Interface (Optional) |
| 22 | DC12V/3A OUT | Dual DC12V3A power output, for provisional DC power supply |
| 23 | OPM | Optical power meter interface (Optional) |
| 24 | PSE IN | PSE power sourcing equipment. Tests PoE voltage/LAN test port |
| 25 | PoE OUT / LAN | PoE power supply output or LAN test port (Using test PoE or non-PoE IP camera) |
| 26 | CVBS OUT | Video signal output (BNC interface) / cable tracer interface |
| 27 | SFP | SFP optical module port |
| 28 | LED Lamp | LED lamp |
| 29 | HD-SDI / EX-SDI IN | HD-SDI/EX-SDI input (BNC interface) (Optional) |
| 30 | AHD/CVI/TVI/CVBS IN | CVBS IN/AHD/TVI/CVI Coaxial interface / (BNC interface) (AHD/TVI/CVI(Optional)) |
| 31 | RS485 | RS485 Interface: RS485 communication for the PTZ |
4.2 Bottom Interface
| No. | Interface | Description |
|---|---|---|
| 32 | DC15V IN | DC 15V 1.6A charging interface. |
| 33 | DC24V/2A OUT | DC 24V 2A power output |
| 34 | DC5V/2A OUT | USB 5V 2A power output, transmit data |
| 35 | IN-AUDIO-OUT | Audio input interface. |
| 36 | TF Card Slot | Micro TF card moveable (comes with 8GB, supports up to 32GB) |
| 37 | IN-AUDIO-OUT | Audio output and earphone interface |
| 38 | HDMI OUT | HDMI output interface |
| 39 | TDR | TDR cable test interface (Optional) |
| 40 | UTP / Cable Tracer | UTP cable port: UTP cable tester port/ Cable tracer port |
| 41 | TDR | TDR cable test port. (Optional) |
| 42 | VGA IN | VGA input |
| 43 | HDMI IN | HDMI IN (Optional) |
| 44 | Microphone | Microphone |
4.3 Control Buttons
| No. | Button/Indicator | Description |
|---|---|---|
| 1 | Power Button | Press >2 seconds to turn on/off device; short press to turn on/off menu display. |
| 2 | Charge Indicator | Red when charging, off when fully charged. |
| 3 | RS485 TX Indicator | Red when RS485 data is being transmitted. |
| 4 | RS485 RX Indicator | Red when RS485 data is being received. |
| 5 | Power Indicator | Green when tester is powered on by adapter. |
| 6 | MENU Key | Press to call short-menu. |
| 7 | Zoom Key | 4x zoom the image displays. |
| 8 | FAR+ Key | Far focus: Focus the image faraway. |
| 9 | NEAR- Key | Near focus: Focus the image nearby. |
| 10 | TELE+ Key | TELE: zoom in the image. |
| 11 | WIDE- Key | WIDE: zoom out the image. |
| 12 | CLOSE Key | Return/Close: Return or cancel menu parameters, close or decrease aperture. |
| 13 | OPEN Key | Open/set, Confirm parameters, open or enlarge aperture. |
| 14 | Up Arrow | Upward, set function or add parameter. Tilt PTZ upward. |
| 15 | Right Arrow | Rightward, select parameter value, add value. Pan PTZ right. |
| 16 | Down Arrow | Downward, set function or reduce value. Tilt PTZ downward. |
| 17 | Left Arrow | Leftward, select parameter value. |
| 18 | ENTER Key | Confirm key (Long press to capture screen). |
| 19 | RETURN Key | Return/Close: Return or cancel menu parameters, close or decrease aperture. |
| 20 | Multimeter Interface | Multimeter interface (Optional). |
5. Setup and Initial Use
5.1 Installing the Battery
The tester has a built-in lithium-ion rechargeable battery. For safety during transportation, the battery cable inside the battery compartment is disconnected. Before using the instrument, ensure the battery cables are properly connected.
- Normally, it is not necessary to disconnect the cable during regular use.
- Pressing the power key (labeled with a circle and vertical line) continuously for more than 2 seconds will turn the tester on or off.
- Charging: Use only the original adapter and connected cable. The charge indicator lights red while charging and turns off automatically when charging is complete. When the charge indicator turns off, the battery is approximately 90% charged. Charging can be extended for about 1 hour, and charging within 12 hours will not damage the battery.
- Reset: If the tester works abnormally, press the power key for several seconds to restore default settings.
5.2 Instrument Connection
5.2.1 IP Camera Connection
To connect an IP camera:
- If the IP camera has an independent power supply, connect the IP camera to the IPC tester's LAN port.
- Observe the tester's LAN port indicators: if the link indicator is green and the data indicator flickers, communication is established. If not, check the IP camera's power and network cable.
- PoE Power: If the IP camera requires PoE power, connect it to the IP tester's LAN port. The tester will supply PoE power. Click the POE icon to toggle PoE power on/off.
- Note: If the tester's PoE power supply is turned off via the menu, a PoE switch or power sourcing equipment (PSE) can be connected to the tester's PSE IN port. The tester's LAN port will then supply PoE power to the IP camera. In this configuration, the tester cannot receive data from the IP camera, but a computer connected to the PoE switch can.
Warning: PoE switches or PSE power sourcing equipment should only be connected to the tester's "PSE IN" port. Connecting to other ports will damage the tester.
5.2.2 Analog Camera Connection
To connect an analog camera:
- Connect the camera's video output to the IP tester's VIDEO IN port. The image will display on the tester after pushing the PTZ icon.
- The CCTV IP Tester's "VIDEO OUT" interface can connect to the video input of a monitor or optical video transmitter/receiver, displaying the image on both the tester and the external monitor.
- Connect the camera or speed dome's RS485 controller cable to the tester's RS485 interface. Ensure correct positive and negative connections.
5.2.3 HD Coaxial Camera Connection
CVI, TVI, and AHD cameras are classified as HD coaxial cameras. The connection method for SDI cameras also applies to these types.
5.2.4 HDMI IN
Connect a DVR or other device's HDMI output port to the tester's HDMI IN port. The tester will display the input image.
5.2.5 HDMI Output
The built-in HDMI OUT port can output video files, media files, and screen displays to a high-definition TV with a resolution up to 4K 60FPS. The tester can output images from analog, IP (universal definition), and SDI data cameras to an HD television. It can also function as an SDI to HDMI converter.
- When HDMI output is enabled via the drop-down menu and connected to a monitor, the tester screen will black out and output HDMI. In this state, use a mouse to operate the tester.
- When HDMI output is turned off in the drop-down menu, select "CVBS & HD Camera - HDMI output" to have the tester send an HDMI color signal.
- HDMI output resolution and frame rate can be adjusted in "System Settings - More Settings".
6. Operation
6.1 OSD Menu
- Press the power key for 2 seconds to turn on/off.
- Short press the power key to enter/exit sleep mode.
- If the tester works abnormally and cannot be turned off, press the power key for several seconds to force a reset.
6.1.1 Drop-down Menu
Press and slide twice at the top right corner of the screen to open the shortcut menu. This menu includes quick access to:
- PoE output: Turn on or off PoE power.
- PING: Detect network or IP continuity.
- DHCP: Turn on DHCP server to assign dynamic IP addresses.
- File explorer: View music, videos, pictures, documents, zip files.
- Volume: Set volume level.
- Light: Turn on or off LED light.
- Wi-Fi: Turn on or off Wi-Fi.
- Auto HD: Turn on or off auto HD function for TVI/CVI/CVBS cameras.
- HDMI IN: Turn on HDMI input function.
- TV OUT: Turn on or off TV OUT, support BNC loop test, detect BNC cable continuity.
- IP setting: Turn on IP setting.
- LAN INFO: Display real-time upload/download speed of network port or Wi-Fi.
- Brightness: Set screen brightness and sleep time.
- Touch point: Display touch point position when enabled.
- Network speed: Display current network speed information.
- Screen record: Start screen recording (files saved in movies directory of internal SD card).
- Power OFF: Turn off the tester.
- HDMI OUT: When enabled and connected to a monitor, the tester blacks out and outputs HDMI. Operate with a mouse.
6.1.2 Short-cut Menu
Access the shortcut menu by pressing the tester's "MENU" key. This menu is customizable. Long-press any app in the "all applications" list to move it to the shortcut menu. To delete an app from the shortcut menu, long-press it.
6.1.3 Screen Capture
Long-press the "ENTER" key to capture the current screen interface. Images are saved and can be viewed in "File Explorer - sdcard - Pictures - Screenshots".
6.1.4 Link Monitor
Tap the "Link Monitoring" icon to enter. This function detects instrument port rate (10/100/1000M), signal quality, and upload/download speed in real-time. It helps determine if the network video access bandwidth for devices like NVRs is normal. If a four-core cable is used with a Gigabit device, a "link limited" prompt will appear.

6.1.5 TesterPlay (Mobile/PC Screen Projection)
This feature allows screen projection to mobile devices (Android only) or PCs.
- Mobile: The tester creates a Wi-Fi hotspot, or both devices connect to the same Wi-Fi network. Download and install the "Remote control" app on your mobile phone. In the app, select "TesterPlay", click "Start" to generate an RTSP URL. In the mobile app, use "Auto search IP" or "Manually search IP" (e.g., 192.168.0.186) to find the tester's IP and click "Play" to display the real-time image and control the IPC Tester.
- PC: Install VLC player on your PC. In VLC, go to "Media - Open Network Streaming" and input the RTSP address (found on the tester's screen) to view the real-time projection.
6.1.6 IP Discovery
Press the "IP Discovery" icon to auto-scan the entire network segment for IP addresses. The tester can automatically modify its IP to match the scanned camera's IP segment.
- Local IP: The tester's IP address.
- Discovery IP: The IP address range to scan.
- DHCP Server: Toggle DHCP server on/off.
- ONVIF/Non ONVIF: Options for camera types.
- Start: Initiates the scan.
- Application: This app simplifies IP camera setup by automatically scanning the network and adjusting the tester's IP address, improving efficiency.
6.1.7 IPC Test Pro
The "IPC Test Pro" app integrates multiple camera testing functions into one interface, enhancing efficiency for camera test procedures.
- Discovery IP: Displays the connected tester equipment's IP address. If directly connected to a camera, it shows the camera's IP. If connected to a LAN, it shows the current IP.
- Temp IIP: After searching, the modified tester's IP address is not saved unless "Temp IP" is selected.
- Start: PING function to test camera IP.
- Rapid ONVIF: Quick link for ONVIF cameras.
- NON ONVIF: Quick link for non-ONVIF cameras.
- Application: Auto-scans the network segment and modifies the tester's IP to match the camera's, streamlining setup.
- Rapid ONVIF Test: Displays 8K H.265/H.264 camera images via mainstream. One-key activation for Hikvision cameras. Auto-scans ONVIF cameras in different network segments, lists camera names and IPs, and can auto-login and display images.
- Activate HIKVISION Camera: Automatically recognizes and prompts to activate inactivated Hikvision cameras.
- Pop-up Settings Menu: Access by clicking the "ONVIF setting" icon.
- Cross network scan: Allows scanning across different network segments.
- Auto Login: Automatically logs into cameras using the last-used password (default "admin" for first use).
- Video transmission protocol: UTP and TCP protocols supported.
- Open password cracker: Cracks camera passwords.
- View manual: Opens the manual.
- Restore Defaults settings: Reverts "Rapid ONVIF" to default settings.
- OK: Saves modified parameters.
- Live Video Tools: In "Live video" menu, click "Video Menu" for Snapshot, Record, Photo, Playback, PTZ, and Settings.
- ONVIF PTZ control: Tap the image to move the PTZ camera. Compatible IP PTZ cameras will rotate accordingly.
- IP camera video settings: Click "Video Set" to adjust encoder and resolution settings.
- Image setting: Click "Imaging Set" to adjust brightness, saturation, contrast, sharpness, and backlight.
- Profiles: View current video streaming configuration files and switch between Major and Minor streams.
- Preview pictures: Quickly preview and zoom images, with automatic and manual refresh.
- Identification: View camera information.
- Time set: Set camera time.
- Maintenance: Camera software reset or factory settings.
- User Set: Modify camera user name, password.
- Network setting: Change IP address.
- Zoom in image: Press the zoom key to enter/exit zoom mode. Tap/drag to move the enlarged image.
- Snapshot: Click the "Snapshot" icon to save the current video frame as a JPEG file to the SD card. Manual mode allows naming the file; auto-storage names files automatically.
- Record: Click the "Record" icon to start video recording. A red flashing icon and timer indicate recording. Click "Stop" to save.
- Photo: Click the "photo" icon to view saved thumbnail photos. Double-tap to view full screen. Long-press to rename or delete.
- Recorded video playback: Click "Playback" to view recorded videos. Long-press to rename or delete.

6.1.8 HDMI IN (*Optional*)
For HDMI in HD signal test, tap the HDMI IN icon. When the tester receives an HDMI image, the top toolbar shows the resolution. Select "resolution" in the settings menu to adjust. Double-tap the screen for full image display. Supported resolutions include: 3840x2160/2K_2560x1440p/1920x1080p/1920x1080i/720x480p/720x576p/1280x720p/1024x768p/1280x1024p/1280x900p/1440x900p.
- Snapshot: Click the "Snapshot" icon to save the current video frame as a JPEG file.
- Video record: Click the "Record" icon to start video recording.
6.1.9 VGA IN (*Optional*)
For VGA in HD signal test, tap the VGA IN icon. The tester displays the resolution on the top toolbar. Double-tap for full image display. Supported resolutions include: 1280x1024/960/800/768/720P 60FPS/1152x870P 60FPS/1024x768P 60FPS/800x600P 60FPS/640x480P 60FPS.
6.1.10 Analog Camera Test
For analog camera test and PTZ control, click the CVBS icon.
- PTZ Controller Parameter Setting: Select "PTZ" to enter settings.
- Protocol: Use arrow keys to select protocols (Pelco-D/P, Samsung, Yaan, LiLin, CSR600, Panasonic, Sony-EVI, etc.).
- Port: Select communication port for PTZ camera control (RS485).
- Baud: Select baud rate (150-115200).
- Address: Set ID (0-254) to match PTZ camera.
- Pan/Tilt speed: Set speed (0-63).
- Set/Call preset position: Set and save preset positions (1-128).
- PTZ Control by Screen Touch: Tap left/right/up/down on the video image to control PTZ. Pinch to zoom.
- PTZ Control by Key Buttons: Use arrow keys for direction, OPEN/CLOSE for aperture, FAR+/NEAR- for focus, TELE+/WIDE- for zoom.
- Video and Storage Setting: Click "set" icon to adjust brightness, contrast, color saturation, and file storage method (auto/manual).
- Snapshot, Record, Photo, Playback: Operations are similar to IP camera testing.
6.1.11 Color-bar Generator (TV OUT)
Click the TV OUT icon. The tester sends color bars from the "Video out" port. Click "PAL/NTSC" to select output formats. This is useful for BNC loop tests and checking transmission channels.
6.1.12 AutoHD (*Optional*)
Automatically recognizes resolution and displays the image of the connected camera. Supports coaxial PTZ control, OSD menu, and up to 8MP TVI/CVI/AHD and CVBS cameras.
6.1.13 HD Coaxial & Analog Level Test (*Optional*)
Accurately measures video peak level, sync level, and burst level using high-speed sampling. Helps determine if camera images and attenuated images are normal, quickly detecting faults.
- Image display: Select camera type; no resolution selection needed.
- Level Meter Test: Select camera type and resolution, then click "test".
- Color bar generation: Click "CVBS" to enter the color bar generation app.
- Test Result: Displays percentage and signal grid compared to reference values. Warnings appear if values are below threshold.
- Reference value/Threshold: Customizable values for comparison.
- Reset: Resets reference value and threshold.
- Create documents: Generates testing reports with customer, level meter, camera, and instrument information.
6.1.14 SDI Camera Test (*Optional*)
Click the SDI icon to enter. Supports SDI camera test, Dome camera test, and PTZ control. Displays image data upon reception. Double-tap for full screen. Supported resolutions: 1280x720P (25/30/50/60Hz), 1920x1080P (25/30/50/60Hz), EX-SDI: 2560x1440P (25/30FPS), 3840x2160P (20/30FPS). Can use HDMI output as SDI to HDMI converter.
6.1.15 CVI Camera Test (*Optional*)
Click the CVI icon to enter. Supports HD CVI camera, CVI dome camera test, and PTZ control. Displays image resolution on the top bar. Double-tap for full screen. Supported resolutions: 1280x720P (25/30/50/60FPS), 1920x1080P (25/30FPS), 2560x1440P (25/30FPS), 2592x1944P (20FPS), 2960x1920P (20FPS), 3840x2160P (12.5/15FPS).
6.1.16 TVI Camera Test (*Optional*)
Click the TVI icon to enter. Supports HD TVI camera, TVI dome camera test, and PTZ control. Displays image resolution on the top bar. Double-tap for full screen. Supported resolutions: 1280x720P (25/30/50/60FPS), 1920x1080P (25/30/50/60FPS), 2048x1536P (18/25/30FPS), 2688x1520P (15FPS), 2560x1440P (15/25/30FPS), 2560x1944P (12.5/20FPS), 3840x2160P (12.5/15FPS).
6.1.17 AHD Camera Test (*Optional*)
Click the AHD icon to enter. Supports AHD camera, AHD dome camera test, and PTZ control. Displays image resolution on the top bar. Double-tap for full screen. Supported resolutions: 1280x720P (25/30FPS), 1920x1080P (25/30FPS), 2048x1536P (18/25/30FPS), 2560x1440P (15/25/30FPS), 2560x1944P (12.5/20FPS), 3840x2160P (15FPS).
6.2 NET TOOL PRO
The NET TOOL PRO suite includes Cable Test, Wireless Tool, Link Tool, Full Duplex Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, and LLLDP functionalities.
- IP Address Scan: Connect the cable to the LAN port. Set the IP address search range (Start and End IP) and click "Start". Can also scan for open ports by inputting an IP address in "Port Number Scan".
- PING Test: A conventional network debugging tool to check if the connected IP camera or network equipment's Ethernet port is working and if the IP address is correct. Set Local IP, Remote IP, Packet count, Packet Size, Packet time, and Timeout. Click "Start".
- Network Test (Ethernet Bandwidth Test): Requires two testers (one as Server, one as Client) or a tester and a computer with compatible software. Both must be on the same network segment.
- Start Server: Click "Start Server" to make the tester act as a server.
- Start Send Packet Test: On the client tester, input the server's IP address and click "Start" to send packets and test network speed.
- Port Flashing: Connect a network cable to the tester's "LAN" port and click the Port Flashing icon. The tester sends a signal to make the connected LAN port of the switch flash, helping to locate cables.
- DHCP Server: Click the DHCP icon. Select "Start" and configure network settings. Click "Save" to assign dynamic IP addresses. Click "Refresh" to view the client list.
- Trace Route: Determines the path of an IP packet to its target. Input tracking IP address or domain name, set max hop count (default 30), and click "start".
- Link Monitor: Click the Link Monitor icon. Checks if an IP address is occupied by other network devices to avoid conflicts. Add desired IP addresses and click "Start". A check mark means occupied, an "X" means available.
6.3 Power Management V2.0
- PoE 48V OUT: Click the screen and change the switch to "ON" or "OFF" to use PoE Power Output. Supports PoE power output via pins 1, 2, 3, 6 and 4,5,7,8 on the LAN port. Network cameras supporting PoE can be directly connected. Click "Mode A/Mode B/4-Pair" to switch PoE pair mode. For power over 30W, select 4-Pair mode.
- DC 24V 2A: Ensure the camera supports DC 24V power. Use the green plug terminal to connect cables, paying attention to positive and negative terminals. Do not connect in reverse.
- DC12V/3A/OUT: Automatically turns on when the tester is powered on.
- PSE IN: Connect a PoE switch to the tester's PSE IN port. Connect an IP camera or other PoE device to the tester's LAN port. The PoE voltage, power supply protocol (802.3af/at or non-standard), and cable pin connection status are displayed.
- 15V Power Input Test: Connect a DC15V power adapter to the charging port. The screen displays current adapter input voltage and power.

6.4 PoE Power / DC12V 3A and DC 5V 2A USB Power Output
DC 12V and DC 5V power output functions are automatically turned on when the tester is powered on. The DC 5V USB can power external USB devices even if the tester is off. To use PoE Power Output, click the icon and toggle the switch. The IP camera must be connected to the LAN port before turning on PoE. The tester displays "48V ON" when PoE power is active. Switch PoE pair mode (Mode A/Mode B/4-Pair) as needed; 4-Pair mode is required for power over 30W.
6.5 Cable Test
Connect LAN or telephone cables to the CCTV tester and cable tester. The screen displays connection status, cable type, wire sequence, and cable tester kit serial number (255). Additional cable tester types may require extra cost.
- Visual Judgment:
- All sequence correct: Gigabit straight/cross network cables.
- Cable sequence wrong but available: 100M straight-through/cross network cable.
- All sequence wrong: Not available.
- Fault Location:
- "x" at tester-end/cable tester-end: RJ45 connector or within 1 meter is faulty.
- "x" in middle: RJ45 connector at end is normal, breakpoint 1 meter away.
- No communication/display "x": RJ45 connector at end is faulty, middle is normal.
6.6 RJ45 Cable TDR Test
Connect the cable to the tester's LAN port and click the RJ45 TDR test icon. This app tests cable status, length, and attenuation.
- Single Test/Repeat Test: Performs a single test or continuous tests.
- Status: Displays "online", "open circuit", or "short circuit".
- Length: Max test length 180 meters. Accurate for open/short circuits; less accurate for "online" status.
- Cable Quality: Green for good, Yellow for poor, Red for water-poured. Attenuation displayed for lengths over 10 meters.
- Advanced Test: Tests cable pair status, length, attenuation, reflectivity, impedance, skew.
- Attenuation reflectivity: 0 indicates best quality.
- Impedance: 100Ω indicates best quality (range 85-135Ω).
- Skew: 0ns indicates best quality for 1000M link. Over 50ns causes Bit Error Rate.
- Cable Sequence Diagram: Displays straight-through and cross-over cable diagrams.
6.7 Cable Tracer (*Optional*)
Connect the tested cable (or BNC cable) to the UTP port or CABLE SCAN (VIDEO OUT) port. Click the icon to enter. Adjust audio type by clicking "Number".
- UTP Mode: For searching normal network cables.
- STP Mode: For searching shielded network cables.
- Sensitivity: Rotate the switch to adjust (clockwise increases, counter-clockwise decreases).
- Cable Identification: Connect the other end of the tested network cable to the "UTP" port of the cable tracer. The cable sequence, continuity, test box number, and network cable type will be displayed. "G" indicates shielded cable continuity.
- Indicator Lights: 1-8 indicators flash according to cable sequence. DIRECT/CROSS/OTHER lights indicate network cable type.
- Silent Mode: Press "MUTE" for 2 seconds to enter/exit silent mode.
Note: Ensure the cable tracer battery is connected with correct polarity (+ and -) to avoid damage.
Note: The cable tracer may pick up noise from other signals when receiving audio from the tester.
6.8 TDR Cable Test (*Optional*)
Note: The testing cable must not be connected to any equipment to avoid damage to the tester.
Connect the alligator clip cable to the TDR port. Ensure good connection for accuracy. Supports BNC, network, RVV control, telephone, and TVVB cables. 11 user-defined cable groups can be set.
- Curve Result Analysis:
- Inflection point: Position of break or short-circuit.
- Short circuit: Upward trend after inflection point.
- Open (break point): Downward trend after inflection point.
- Curve Operation: Zoom (pinch or virtual keyboard), Move (drag).
- Calibration: Due to variations in cable impedance, calibration is necessary for accuracy. Select "Cable" "Type" to choose cable type, then adjust wave speed until displayed length matches actual length. Click "Save".
Note: TDR reflect signal can be affected by cable quality or poor connection, leading to different measurements. TDR measurements are for reference only.
6.9 Cable Length
Note: The measured cable cannot be connected to any device to avoid incorrect measurements.
Insert the RJ45 to BNC converter into the UTP port and connect alligator clips to its BNC interface. Peel and expose the copper core of the measured cable. Clamp red and black alligator clips to the copper core. Ensure good contact for accurate results.
- Open Circuit Test: Click the icon to enter. Supports BNC, network, RVV control, telephone, and TVVB cables. 11 user-defined cable groups. Select "Cable name", then "Length test" to measure. "Repeat test" for continuous measurement. Short-circuit status is not displayed.
- Short Circuit Test: Select cable type "UTP CAT 5E/6E (4 pairs)" to check short circuits for cores 1-8.
- Calibration: Adjust wave speed for user-defined cables.
6.10 BNC Attenuation Test (*Optional*)
Tests coaxial cable transmission attenuation in real-time using high-speed sampling. Detects attenuation over long distances and assesses BNC cable quality.
- Test Methods:
- Connect two alligator clip cables to CVBS IN and CVBS OUT ports. Clip red to red and black to black, then click "calibration".
- After calibration, clip the red clip to the copper core of the BNC cable and the black clip to the outer envelope. Attenuation value will be displayed.
- Reset: Click "Reset" to restore default settings.
6.11 Digital Multi-meter (*Optional*)
Click the icon to enter the Digital Multi-meter function.
- Symbols: U (DC Voltage), Ω (Resistance), A (DC Current), Diode, ~U (AC Voltage), ~A (AC Current), Continuity, Capacitance.
- Operating Instructions:
- DC Voltage Measuring: Connect black lead to "COM", red to "V/Ω". Select U. Auto/manual range. Max 660V DC.
- AC Voltage Measuring: Connect black lead to "COM", red to "V/Ω". Select ~U. Auto/manual range. Max 660V AC.
- DC Current Measuring (Manual Range Only): Shut down power. Connect black lead to "COM", red to "mA" (max 660mA) or "10A" (max 10A). Select A. Manual range.
- AC Current Measuring (Manual Range Only): Shut down power. Connect black lead to "COM", red to "mA" (max 660mA) or "10A" (max 10A). Select ~A. Manual range.
- Resistance Measuring: Shut down power, discharge capacitors. Connect black lead to "COM", red to "V/Ω". Select Ω. Auto/manual range.
- Continuity Testing: Shut down power, discharge capacitors. Connect black lead to "COM", red to "V/Ω". Select continuity icon. Buzzer sounds if resistance < 50Ω.
- Diode Testing: Test separately, not in circuit. Connect black lead to "COM", red to "V/Ω". Select diode icon.
- Capacitance Measuring: Discharge capacitors fully. Connect black lead to "COM", red to "V/Ω". Select capacitance icon. Auto/manual range.
- Data Hold: Click "Hold data" to freeze the display.
- Relative Value Measurement: Click "Relative" to save current value as reference.
- Meter Protection: Warnings for voltage and current limits.
6.12 Optical Power Meter (*Optional*)
Click the icon to enter. Supports ten wavelengths (850nm, 980nm, 1270nm, 1300nm, 1310nm, 1490nm, 1550nm, 1577nm, 1625nm, 1650nm). Displays linear or nonlinear optical power. Essential for fiber optic communication, cable TV, and CCTV security systems.
- Note: Keep fiber connector and dust cap clean. Clean detector with special alcohol.
- Data Hold: Click "Hold" to freeze data.
- Relative Power Value (Optical Link Loss) Measurement: Click "relative" to set current fiber power as reference. Input another fiber to measure relative value.
6.13 Visual Fault Locator (*Optional*)
Click the icon to enter. VFL has four modes: "Steady mode", "Evasive 1Hz", "Evasive 2Hz", and "Time off".
- Steady mode: Red laser source emits steadily.
- Pulse mode: "Evasive 1Hz" and "Evasive 2Hz" emit pulsed red laser.
- Time off: VFL turns off. Timed turn-off options (5, 10, 30, 60, 120 mins).
6.14 Audio Record
Connect an audio device to the IP tester's audio input port. Click the Audio Recorder icon to enter.
6.15 Audio Player
Click the icon to enter. The audio player supports MP3 format audio files.
6.16 Media Player
Click the icon to enter. The Media player can browse video and image files. Supports MP4, H.264, MPEG4, and MKV formats. Recorded files can be played directly. Automatically displays video files from the SD card. Click RETURN to exit. Long-press a file to rename or delete.
6.17 RTSP Player
Allows viewing RTSP video streams from IP cameras, especially if ONVIF or IPC Test apps fail. From the main menu, select "APP Tool" folder, then "RTSP Player". Select "RTSP" icon for MJPEG or "RTSP HD" for H.264. Input IPC Username, IPC Password, and RTSP Add (URL) or search for RTSP streams. Click "Enter" to view live video.
6.18 Hik Test Tool
Designed for activating and debugging Hikvision cameras. Auto-identifies inactivated Hikvision cameras and displays images.
- Activation: Select "online detection" to view inactivated cameras, then click "activate".
- Auto Open ONVIF Protocol: After activation, new HIK cameras can auto-open ONVIF protocol by clicking "play", modifying channel name, network info, or user info.
- Play: For activated cameras, enter password and click "play" to choose "private protocol" or "speed ONVIF" to view images.
- Modify Channel Name: Pop-up OSD settings to edit channel name, display position, font size.
- Modify Network Information: Modify camera IP address, subnet mask, gateway.
- Modify User Information: Modify camera user name and password.
- Factory Reset: Soft resets camera, saving user name, password, and network settings. Other settings are factory reset.
6.19 Dahua Test Tool
Similar to Hik Test Tool, for Dahua IP cameras. Activates and debugs Dahua cameras, displays images, and modifies IP, user name, and password.
6.20 Update
Copy update files to the "update" directory on the SD card. Click the Update icon. Select "Local Update" (from SD card) or "Online Update" (from internet). Online update requires registration and internet connection.
6.21 Office
Quick office app supports editable Excel, Word, and PPT formats.
6.22 LED Flashlight
Click the icon to enter. Click the red button to turn the LED lamp on/off. If not turned off manually, the lamp stays on. Set a timer for automatic shut-off.
6.23 Browser
Click the icon to enter. Type the camera's IP address and press "Go" to access its interface. Note: Live video cannot be viewed in the web browser; use the IP tester's live camera view apps.
6.24 Notepad
Records important testing results. Click "Save" to save contents. Auto-records storage date and time. Click the NOTE icon to view saved contents. Long-press a record to delete.
6.25 System Setting
- Language & Input: Select desired language (English, Chinese, Korean, Russian, Italian, Polish, Spanish, French, Japanese, German, Turkish). Select typewriting or install other typewriting.
- Date/Time: Set date/time of the IP tester.
- IP Settings: Manually set IP address, Subnet Mask, Default Gateway, DNS address, or select "Dynamic allocation" (DHCP). Click "Advanced" to add more IP addresses for testing multiple network segments.
- WLAN Net: Turn Wi-Fi on/off. Scans for wireless networks.
- Wi-Fi Hotspot: Input SSID and password to create a Wi-Fi hotspot.
- Brightness: Adjust screen brightness and sleep time.
- Volume: Set volume level.
- SD Card: Displays SD Card Capacity. Format or unmount SD card.
- FTP Server: Once connected to a network, a computer can read/copy/edit SD card files via FTP. Start the FTP server and input the tester's FTP address in the PC's address bar.
- Version Information: Shows application version info.
- Screen Display Rotation: Flips the display 180 degrees.
- PTZ Address Scan: Toggle on/off before entering "PTZ controller" app to use PTZ Scan feature.
- Online Registration: Register for online updates after connecting to network.
- User Feedback: Connect to network to provide feedback.
- Lock Screen: Set password or pattern lock.
- Restore Factory Settings: Removes all personal files and apps.
6.26 File Explorer
Click "File" on the top bar to select internal or external storage. Click the "..." icon for more operations or to exit. Browse music, videos, pictures, documents, zip files.
6.27 SFP Optical Module Connection
Connect the SFP optical module to the SFP slot on the top of the instrument. Use an optical fiber jumper to connect to the SFP module of a switch or other equipment for network connection and detection. Supports hot-plugging.
Note: Do not look directly into the optical fiber hole of the SFP module to avoid eye damage from lasers. Cover with a dust cap when not in use.
After successful connection, a fiber connection mark appears on the top right. Avoid IP conflicts by modifying the tester's IP in "System Settings - IP Settings".
6.28 Audio Test
Connect an audio pickup device to the IP tester's audio input port with the supplied audio cable to test audio input.
7. User Tips
- Always ensure the battery is adequately charged before starting extensive testing to avoid interruptions.
- When performing cable tests, especially TDR tests, ensure no other devices are connected to the cable to get accurate readings.
- For network diagnostics, utilizing the PING and Link Monitor tools can quickly identify connectivity issues and IP conflicts.
- Take advantage of the screen capture feature to document test results or camera views for reporting or later reference.
- When working with PoE, always verify the camera's power requirements to prevent damage from over-powering or under-powering.
- Regularly check for software updates via the "Update" function to ensure optimal performance and access to new features.
8. Troubleshooting
- Tester not turning on/off: Press the power key continuously for more than 2 seconds. If abnormal, press for several seconds to force a reset.
- IP Camera not communicating: Check if the IP camera is powered on and the network cable is functioning properly. Ensure the tester's LAN port link indicator is green and data indicator flickers.
- PoE Power Output issues: If the tester enters protection mode (e.g., due to camera power over 2A), disconnect all connections, then connect the tester with the power adapter to resume. Ensure the tester is fully charged or >80% charged.
- Network Test (PING) issues: If "Destination host unreachable" or "100% packet loss" occurs, the IP camera or network device may be improperly configured or unplugged.
- Cable Test (RJ45 TDR) inaccuracies: Ensure the cable is not connected to any other equipment. TDR measurements are for reference only and can be affected by cable quality or poor connections.
- Digital Multi-meter "OL" display: Indicates an over-range situation. Select a higher range.
- TDR Cable Test "link limited" prompt: Occurs when using a four-core cable to connect to a Gigabit device.
- HDMI output causes tester to black out: This is normal behavior. Operate the tester with a connected mouse.
- RTSP stream not detected: Refer to the specific camera manufacturer's RTSP stream URL, which can often be found online by searching the camera model number and "RTSP".
- SFP optical module connection issues: Ensure the module is correctly inserted and the fiber connection mark appears on the screen. Check for IP conflicts and adjust the tester's IP if necessary.
9. Specifications
9.1 General Specifications
| Feature | Description |
|---|---|
| Model | IP Camera Tester (IPC-9800CLMOVTADHS Pro) |
| Display | 7 inch retina touch screen, 1280x800 resolution |
| Network Port | 10/100/1000M auto adjust, RJ45, Dual LAN port |
| Wi-Fi | Built-in Wi-Fi, speeds 150M, connects to wireless networks, views IP cameras |
| 8K H.265 Mainstream Test | New hardware decoding, 8K H.265/4K H.264 camera image display by mainstream testing |
| IP Discovery | Auto-scan the whole network segment camera IP |
| Rapid ONVIF | Search camera quickly, auto log in and display image from the camera, activate Hikvision camera |
| Hik Test Tool | Batch activate Hikvision camera, display image, modify Channel, batch modify IP, user name and password parameters etc. |
| DH Test Tool | Batch activate Dahua camera, display image, modify Channel, user name and password parameters etc. |
| IP Camera Type Support | ONVIF, ONVIF PTZ, Dahua IPC-HFW2100P, Hikvision DS-2CD864-E13, Samsung SNZ-5200, Tiandy TD-NC9200S2, Kodak IPC120L, Honeywell HICC-2300T, RTSP Viewer |
| Auto HD (*Optional) | Auto-recognize resolution and display image, coaxial PTZ control, OSD menu, up to 8MP TVI/CVI/AHD and CVBS cameras |
| 4K HD Coaxial Level Test (*Optional) | Hardware high-speed sampling, accurate video peak, sync, burst level measurement, one key to create testing report |
| SDI Video Signal Test (*Optional) | 1 channel HD-SDI/EX-SDI input (BNC), resolutions: 720P 60fps, 1080P 60fps, 1080i 60fps, EX-SDI: 2560x1440P/25/30fps, 3840x2160P 20/30fps, UTC control, OSD menu |
| CVI Video Signal Test (*Optional) | 1 channel CVI input (BNC), resolutions: 720P (25/30/50/60fps), 1080P (25/30fps), 2560x1440P (25/30fps), 2592x1944 (20fps), 2960x1920 (20fps), 3840x2160 (12.5/15fps), UTC control, OSD menu |
| TVI Video Signal Test (*Optional) | 1 channel TVI input (BNC), resolutions: 720P (25/30/50/60fps), 1080P (25/30fps), 2048x1536P (18/25/30fps), 2688x1520P (15fps), 2560x1440P (15/25/30fps), 2560x1944P (12.5/20fps), 3840x2160 (12.5/15fps), UTC control, OSD menu |
| AHD Video Signal Test (*Optional) | 1 channel AHD input (BNC), resolutions: 720P (25/30fps), 1080P (25/30fps), 2048x1536P (18/25/30fps), 2560x1440P (15/25/30fps), 2560x1944P (12.5/20fps), 3840x2160P (15fps), UTC control, OSD menu |
| Analog Video Test | 1 channel BNC Input & 1 channel BNC Output, NTSC/PAL (Auto adapt) |
| Video Level Meter | PEAK video signal level, SYNC signal level, COLOR BURST chroma level measurement for CVBS camera. |
| Zoom Image | Supports Analog and IP camera image zooming & movement |
| Snapshot, Video Record and Playback | Capture images, record live video as JPG file. Media player views photos and plays back video. |
| HDMI IN *(Optional) | HDMI IN, Support 4K 30FPS, 3840x2160P 30FPS, 720x480P/720x576P/1280x720P/1920x1080P/1024x768P/1280x1024P/1280x900P/1440x900P. |
| HDMI Output | 1 channel HDMI output, supports up to 4K 60fps |
| VGA Input *(Optional) | VGA in HD signal test |
| RJ45 Cable TDR Test | RJ45 cable TDR test and cable quality test, to test cable pair status, length, attenuation reflectivity, impedance, skew and other parameter. |
| 24V 2A Power Output | Output DC24V/2A power to camera |
| 12V 3A Power Output | Output DC12V/3A power to camera |
| USB 5V Power Output | 5V 2A power output |
| PoE++ Power Output | 55V PoE++ power output, Max power 90W |
| Screen Management | Under normal mode, you can change icons sequence and self-define the number of icons in each page |
| Drop-down Menu | PoE power switch, IP setting, WLAN switch, HDMI IN functions etc screen lock, password lock screen or pattern lock |
| Audio Test | 1 channel audio signal input and 1 channel audio signal output to connect headphones |
| PTZ Control | Support RS485 control, Baud 600-115200bps, Compatible with more than 30 protocols such as PELCO-D/P, Samsung, Panasonic, Lilin, Yaan, etc |
| Color Bar Generator | Output one channel PAL/NTSC color bar video signal for testing monitor or video cable (red, green, blue, white and black color) |
| UTP Cable Tester | Test UTP cable connection status and display on the screen. Read the number on the screen |
| Data Monitor | Captures and analyzes the command data from controlling device, also can send hexadecimal |
| NET TOOL PRO | NET TOOL PRO-Cable Test, Wireless Tool, Link Tool, Full Duplex Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, LLLDP. |
| Cable Tracer *(Optional) | Find a connected cable from a bundle of cables using audio tones |
| PoE/PSE Voltage Test | Measures PoE switch voltage and displays pin configuration |
| TDR Cable Test *(Optional) | BNC cable, network cable, telephone cable, RVV cable and elevator cable, cat 5/6 cable's length and short circuit. measurement range 1.2KM |
| Cable Length | For cable's Open test, such as BNC cable, UTP cable, telephone cable test max test length up to 3KM, (Cable's short-circuit test not supported) |
| BNC Attenuation Test *(Optional) | Through hardware high-speed sampling and processing technology, test the BNC coaxial cable transmission attenuation value, detect the transmission quality of BNC cable. |
| External Power Supply | 15V 1.6A |
| Battery | Built-in 11.1V Lithium ion battery, 5200 mAh |
| Rechargeable | Fasting charge, after charging 3.5 hours, normal working time 11 hours |
| Operation Setting | Capacitive touch screen, OSD menu, select your desired language: English, Chinese, Korean, Russian, Italian or Polish, etc |
| Auto Off | 1-30 (mins) |
| Working Temperature | -10°C to +50°C |
| Working Humidity | 30%-90% |
| Dimension/Weight | 240mm x 154mm x 46mm / 620g |
9.2 Multi-meter Specifications
Counts: -6600~+6600
Conversion rate: 3 times/s
Current modes for clamp meter with ZERO function
Isolation: the Multi-meter connector must be isolated with the other connector.
DC Voltage
| Range | Accuracy | Resolution |
|---|---|---|
| 660mV (Manual range) | 0.1mV | |
| 6.600V | ± (0.3%+4) | 1mV |
| 66.00V | 10mV | |
| 660.0V | 100mV |
AC Voltage
| Range | Accuracy | Resolution |
|---|---|---|
| 660.0mV (Manual range) | ± (1.5%+6) | 0.1mV |
| 6.600V | 1mV | |
| 66.00V | ± (0.8%+6) | 10mV |
| 660.0V | 100mV |
DC Current
| Range | Accuracy | Resolution |
|---|---|---|
| 6.600mA | 1uA | |
| 66.00mA | ± (0.5%+3) | 10uA |
| 660.0mA | 100uA | |
| 10.00A | ± (1%+5) | 10mA |
AC Current
| Range | Accuracy | Resolution |
|---|---|---|
| 6.600mA | 1uA | |
| 66.00mA | ± (0.5%+3) | 10uA |
| 660.0mA | 100uA | |
| 10.00A | ± (1%+5) | 10mA |
Resistance
| Range | Accuracy | Resolution |
|---|---|---|
| 660.0Ω | ± (0.8%+5) | 0.1Ω |
| 6.600KΩ | 1Ω | |
| 66.00KΩ | ± (0.8%+2) | 10Ω |
| 660.0KΩ | 100Ω | |
| 6.600MΩ | 1KΩ | |
| 66MΩ | ± (1.2%+5) | 10KΩ |
Continuity
| Range | Resolution | Function |
|---|---|---|
| 660.0Ω | 0.1Ω | Measurement value less 30Ω±3Ω, the tester will sound |
Diode
| Range | Resolution | Function |
|---|---|---|
| 2.0V | 1mV | Schottky diode: 0.15~0.25V, Rectifier diode: 0.6~1.0V, Triode PN junction: 0.5~0.8V |
Capacitance
| Range | Accuracy | Resolution |
|---|---|---|
| 6.600nF | ± (0.5%+20) | 1pF |
| 66.00nF | 10pF | |
| 660.0nF | ± (3.5%+8) | 100pF |
| 6.600µF | 1nF | |
| 66.00µF | 10nF | |
| 660.0µF | 100nF | |
| 6.600mF | ± (5%+8) | 1µF |
| 66.00mF | 10µF |
9.3 Optical Power Meter Specifications
| Feature | Specification |
|---|---|
| Measure Range(dBm) | -70~+10dBm |
| Wavelength(nm) | 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm |
| Detector | InGaAs |
| Uncertainty | <±3%dB(-10dBm,22°C), <±5%dB(full range,22°C) |
| Display Resolution | Linear:0.1%; Nonlinear:0.01dBm |
| Operating Temperature(°C) | -10~+50 |
| Storage Temperature (°C) | -20~+70 |
| Connector Type | FC/PC |
9.4 Visual Fault Locator Specifications
| Feature | Specification |
|---|---|
| Laser Type | LD |
| Wavelength Calibration | 650nm |
| Output Power | 5mW (Optional 10mW,20mW) |
| Modulation Mode | CW/1Hz/2Hz |
| Measurement Range | 5KM (Optional 10-20KM) |
| Connector | FC/PC exchangeable |
| Working Temperature | -10°C~+50°C |
| Operating Temperature | -20°C~+70°C |
Note: The data above is for reference only and may change without prior notice. For detailed technical inquiries, please contact the Technical Department.
10. Warranty and Support
- Keep the S/N label for after-sale service within the warranty period. Products without an S/N label will be charged for repair service.
- If you have any questions or problems while using the IP camera tester, or if damages occur to the product, please contact our technical department for assistance.
- The manufacturer is not responsible for damages caused by improper use, such as connecting the meter to a voltage source while in current/resistance/capacitance/diode/continuity mode, or measuring on live circuits.
- Man-made damage is not covered under warranty.
For further assistance, please refer to the User Manual (PDF) for detailed item guides and documents.