NJTY T6015

Contents

NJTY T6015 Pointer Insulation Resistance Meter User Manual

USB Rechargeable AC/DC Voltage Detect 2000MΩ Megohmmeter for Electrical Testing

1. Introduction and Overview

The NJTY T6015 is a pointer-type insulation tester designed for critical electrical measurements. It features a modern design, compact size, and portability, making it a reliable and accurate tool for professionals. The T6015 supports 3-range insulation testing and AC/DC voltage testing. It is ideal for measuring the insulation resistance of various electrical equipment and insulating materials, such as transformers, motors, cables, switches, and appliances, and is suitable for routine maintenance, testing, and verification of electrical equipment.

NJTY T6015 Pointer Insulation Resistance Meter
NJTY T6015 Pointer Insulation Resistance Meter

2. Safety Rules and Precautions

This manual contains instructions and safety terms that users must adhere to in order to ensure safe operation and maintenance of the instrument. Please read these operating instructions carefully before using the instrument. The symbol "▲" on the instrument indicates that users must follow the relevant safety instructions in this manual. Pay special attention to the safety rules and warning notes in this manual to avoid electric shock and damage to the instrument.

  1. Read this manual carefully before use.
  2. Do not use the instrument if the battery cover is not securely closed, as this poses an electric shock hazard.
  3. Before use, ensure the test leads' insulation is intact and undamaged.
  4. To avoid damaging the instrument, perform insulation measurements only on disconnected circuits.
  5. Do not press the "Test Button" when measuring voltage.
  6. To avoid electric shock, do not touch the test leads or the circuit being tested during measurement.
  7. Avoid touching the tested circuit immediately after testing, as residual charge may cause electric shock.

3. Product Features

  • Wide Measurement Range: The measurement range can reach up to 2000MΩ, offering versatility.
  • Voltage Measurement: The T6015 can measure AC and DC voltage below 500V (full-scale linear indication).
  • Low Resistance Buzzer Alarm: An audible alarm sounds when the measured resistance is less than the alarm setting value, alerting the user.
  • Working Indicators: Includes battery undervoltage status (red light), automatic shutdown after 15 minutes (single green light), and continuous working indication (double green lights).
  • USB Rechargeable: Uses a 3.7V-18650 rechargeable battery with a convenient Type-C charging interface.
  • Wider Dial Design: Provides a broader indication range for more accurate readings.
  • Automatic Discharge Function: Automatically enters discharge state after shutdown to prevent electric shock from residual charge.
  • Strong Output Load Capacity: Features large output short-circuit current.
  • Transistor Withstand Voltage Measurement: Directly read the withstand voltage value (load voltage) of the material being tested.
  • Portability: Integrated strap holes for aerial work and easy transport.
  • Magnetic & Stand Design: Engineered for convenient, hands-free use with powerful magnets and an adjustable kickstand.
Designed for portability with strap holes for aerial work and easy transport
Designed for portability: Hands-free convenience with integrated strap holes for aerial work & easy transport.
Magnetic and stand design for hands-free use
Magnetic & Stand Design: Engineered for convenient, hands-free use.
Analog vs Digital Multimeter comparison
Analog vs Digital: Choosing the right tool. The T6015 is an analog (pointer type) meter, offering instantaneous response, trend at a glance, and durability.

4. Panel Diagram (T6015)

Diagram of the T6015 insulation resistance tester panel with numbered labels
Panel Diagram of the T6015 Insulation Resistance Tester
  1. Charging indicator light
  2. Work indicator light
  3. Gear position rotary switch (T6015 model)
  4. EARTH input terminal (connected to the ground terminal of the circuit under test)
  5. LINE input terminal (connected to the circuit under test)
  6. Test button
  7. Pointer zero adjustment
  8. Insulation meter reading dial

5. Setup

5.1 Mechanical Zero Adjustment

Before starting insulation measurement, check whether the pointer is consistent with the "∞" (zero position on the left) mark on the insulation meter scale. If not, use a screwdriver to rotate the "pointer zero adjustment" on the meter to adjust the zero position.

5.2 Test Lead Connection

Insert the red and black test leads into the L and E ports of the meter respectively.

5.3 Alligator Clip Usage

The alligator clips can be attached to the test leads for secure connections during testing.

Video demonstrating the alligator clip usage method (1:11 - 1:37).

6. Operating Instructions

6.1 Insulation Resistance Measurement

  1. Start and Shut Down: Press and hold the "test button" for 1 second to turn on the meter. The green "working" indicator light on the upper right corner of the dial will light up. After normal startup, it will automatically shut down after 15 minutes.
  2. Continuous Working State: Press the "test button" three times within 5 seconds after powering on. The meter switches to continuous working state, and the two green indicators in the upper right corner light up, and the automatic shutdown function is canceled.
  3. Manual Shut Down: You can manually shut down the meter 5 seconds after powering on, and press and hold for 1 second to shut down.
  4. Undervoltage State: When working in the undervoltage state, the working indicator light is red, and it will automatically shut down after 15 minutes.
  5. Reading Measurement: After the insulation measurement is started, the test leads touch the insulator to be measured and read the measured value according to the pointer scale.
Video demonstrating insulation resistance testing (1:38 - 2:09) and low resistance alarm (2:10 - 2:15).

6.2 AC and DC Voltage Measurement

  1. The T6015 needs to be switched to the corresponding voltage range for measurement.
  2. Confirm that no insulation measurement has been started (working indicator light is not on).
  3. Use the test leads to touch the two ends of the voltage to be measured.
  4. Read the measured value according to the pointer scale.
  5. Note: When T6015 measures DC voltage, insert the red test lead into "+" and the black test lead into "-".
Video demonstrating actual voltage output test (0:10 - 0:27), DC voltage measurement (0:28 - 0:55), and AC voltage measurement (0:56 - 1:10).

6.3 Transistor Withstand Voltage Measurement

  1. Connect the transistor to be tested to the meter according to polarity.
  2. Press the test button to directly read the BV(V) voltage scale. The read value is the withstand voltage of the transistor (the DC load voltage value L(V) at both ends of the material being tested).
  3. The maximum withstand voltage measurement value of T6015 is 1000V.

6.4 Charging and Replacing Batteries

  1. To prevent electric shock, remove the test leads from the instrument.
  2. When the instrument is working normally, the working indicator light is green, indicating sufficient battery.
  3. When the working indicator light is red, the battery power is undervoltage, requiring charging or replacement.
  4. Use a 5V USB power supply (e.g., power bank, car charger) with the Type-C charging interface.
  5. The charging indicator light turns red during charging and automatically turns green when fully charged.
  6. Do not start the test during charging.
  7. If the battery fails, replace it with a battery of the same specification (3.7V 18650 rechargeable lithium battery).
Video demonstrating battery performance test (2:16 - 2:21) and USB charging (2:22 - 2:27).

7. Technical Specifications

Power Supply: 1 x 3.7V 18650 rechargeable lithium battery.
Dimensions: 161 × 96 × 45 mm.
Weight: Approximately 534 g (including accessories).

Environmental Conditions:

  • Operating Temperature: 0°C-40°C, Relative Humidity <75% (non-condensing).
  • Storage Temperature: -10°C-50°C, Relative Humidity <85%.
  • Calibration Temperature: 23°C ±5°C, Relative Humidity <70%.
T6015 Specifications Overview
ParameterT6015
Rated Test Voltage1000V, 500V, 100V
Low-Resistance Alarm<2MΩ, <1MΩ, <200kΩ
Transistor Withstand Voltage Test1000V, 500V, 100V
Output Short-Circuit CurrentMax 0.75 mA
Measurement Range0-2000MΩ
Measurement Accuracy1M-2000MΩ ±10%
Voltage Measurement RangeDCV500V, 50V; ACV500V (50HZ)
Insulation Test Output Voltage90%-120% of Rated Voltage
Discharge Resistance10M
Voltage Measurement Error±5% (Full Scale)
Battery Detection3.3V Low Voltage Indication
Insulation (between movement circuit and case)>50M
Features and Specifications table for T6015, T6005, T6010
Visual summary of features and specifications.

8. Maintenance

This instrument is a precision electronic device and should be maintained with care.

  1. If the instrument is not used for an extended period, recharge it every two months.
  2. Store the instrument in a dry place and avoid humid environments.
  3. Avoid strong vibrations or impacts, as they may damage the meter head or circuitry.
  4. Do not modify the internal circuitry. If a malfunction occurs, contact us for assistance.

9. Troubleshooting

If the device is not functioning as expected, first check the battery level and ensure it is fully charged. Verify that test leads are properly connected and undamaged. For specific error messages or persistent malfunctions, refer to the detailed user manual (PDF) or contact customer support for assistance.

10. Package Contents

  • T60 Series Insulation Resistance Tester × 1
  • Portable Tool Bag × 1
  • Insulation Resistance Tester Test Leads × 1 pair
  • User Manual × 1
  • 18650 Rechargeable Lithium Battery × 1
  • USB Charging Cable × 1
Packaging list for NJTY T6015
Items included in the package.

11. Support & Documentation

For further details, including comprehensive diagrams and additional language options, please refer to the official user manual PDF. A PDF version of this manual is available for download: User manual (PDF).

For any malfunctions or technical assistance not covered in this manual, please contact the seller or manufacturer's support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.