EARU EAMPS-1-VA

Contents

EARU EAMPS-1-VA Automatic Voltage & Current Protector Socket User Manual

Model: EAMPS-1-VA

Brand: EARU

1. Introduction

The EARU EAMPS-1-VA is an adjustable voltage and current protector socket designed to safeguard your electrical appliances from damage caused by voltage fluctuations (over-voltage, under-voltage) and over-current conditions. It features an EU-type socket, digital displays for real-time voltage and current, and adjustable protection parameters. This manual provides essential information for the safe and effective use of your device.

2. Safety Information

  • This device is designed for indoor use only.
  • Use PC grade fire-resistant materials for safety protection, preventing contact hazards when inserting fingers or small objects.
  • The socket is designed to prevent children from accidentally inserting objects into the device.
  • Do not expose the device to moisture, water, or extreme temperatures.
  • Do not attempt to disassemble, modify, or repair the device. Refer to qualified personnel for service.
  • Ensure the total load of connected appliances does not exceed the rated current of 16A.
  • This device operates with high voltage (above 50Vac or 75Vdc). Exercise caution during installation and operation.

3. Product Overview

3.1. Components

The EARU EAMPS-1-VA features a compact design with a digital display and control buttons. The main components include:

  • Digital Display: Shows real-time voltage (V) and current (A) readings.
  • Power Indicator: Green LED for normal operation, Yellow for delay, Red for protection mode.
  • Control Buttons: 'SET' button for entering/exiting settings, 'Up' and 'Down' arrow buttons for adjusting parameters, and a 'Power' button for manual ON/OFF.
  • EU Socket: For plugging in your electrical appliance.
  • EU Plug: For connecting the protector to a wall socket.
EARU EAMPS-1-VA Front View
Front view of the EARU EAMPS-1-VA protector socket, showing the digital display, control buttons, and EU socket.

3.2. Key Features

The EAMPS-1-VA incorporates intelligent design for comprehensive protection:

Intelligent Design Hierarchical Organization
Diagram illustrating the intelligent design features of the protector.
  • Under Voltage Protection (UV): Automatically disconnects power if voltage drops below a set threshold.
  • Over Voltage Protection (OV): Automatically disconnects power if voltage exceeds a set threshold.
  • Over Current Protection (OA): Automatically disconnects power if current exceeds a set threshold.
  • Automatic Recovery: Restores power automatically once voltage/current returns to normal range after a set delay.
  • Adjustable Power On Delay Time: Customizable delay before power output after connection or recovery.
  • Adjustable Recovery Delay Times: Separate adjustable delay times for under-voltage, over-voltage, and over-current recovery.
  • Working Voltage & Current Display: Real-time monitoring of electrical parameters.
  • Surge Protection: Provides protection against sudden power surges.
  • Data Reset: Option to reset accumulated energy consumption data.
  • Manual Calibration: Allows for manual calibration of voltage and current errors.
LED Display Panel
Highlighted and easy-to-read LED display panel.
Safety Features and Material
Details on PC flame-retardant material, high conductivity copper plate, and safety socket design.

The device is widely used and suitable for various electrical appliances such as air-conditioning, water heaters, microwave ovens, washing machines, humidifiers, electric fans, and electric heaters.

Suitable for Various Electrical Appliances
Example of the protector socket used with a humidifier.

4. Specifications

AttributeValue
Model NumberEAMPS-1-VA
Brand NameEARU
TypeMini
Rated VoltageAC220-240V
Frequency50/60Hz
Rated Current1-16A (Adjustable)
Under Voltage Protection Range140-200V (Adjustable)
Over Voltage Protection Range240-300V (Adjustable)
Delay Time5-300S (Adjustable)
Socket TypeEU
CertificationCE
Wireless FunctionalityNo
Includes BatteryNo
Is Smart DeviceNo
EU LVD VoltageHigh voltage: Above 50Vac or 75Vdc
Product Parameters
Detailed product parameters and dimensions.

5. Setup

  1. Unpack: Carefully remove the EARU EAMPS-1-VA from its packaging.
  2. Inspect: Check the device for any visible damage. Do not use if damaged.
  3. Plug In: Insert the protector's plug into a standard EU wall socket (220-240V, 50/60Hz).
  4. Initial Power-On: Upon connecting power, the yellow light will turn ON if the voltage is within 175Vac-260Vac. After a delay of approximately 5 minutes, or if you press the ON button directly, the green light will stay ON, and the power output will begin.
  5. Connect Appliance: Plug your electrical appliance into the EU socket of the protector. Ensure the appliance's power consumption is within the protector's rated current (max 16A).

6. Operation

6.1. General Operation

  • Normal Operation: When the voltage is within the safe range (175Vac-260Vac), the green 'Power' indicator light is ON, and the device outputs power. The display shows real-time voltage and current.
  • Voltage Protection Mode: If the voltage drops below 175Vac or rises above 260Vac, the device enters voltage protection mode. The red indicator light will be ON, and power output will be cut off to protect the connected appliance.
  • Recovery from Protection: If the voltage returns to a safe range (e.g., above 190Vac and below 240Vac), the yellow indicator light will turn ON. After a set delay (approximately 5 minutes by default), the device will automatically recover to normal working status, and the green light will turn ON.
  • ON Button Functionality: The ON button is only active when the voltage is within the normal working range. It will not function if the device is in voltage protection mode.
  • Unstable Voltage: If the voltage becomes unstable and frequently goes out of the normal range, the device will repeatedly enter voltage protection mode, cutting off power output.
Protect Your Home Appliances
The protector instantly cuts off power during overvoltage or undervoltage faults to prevent appliance damage.

6.2. Setting Parameters

The device allows you to customize various protection parameters. Refer to the flow chart below for navigation and adjustment.

EAMPS-1-VA Operation Instructions Flowchart
Flowchart for EAMPS-1-VA operation and parameter settings.
  1. Enter Setting Mode: Press and hold the 'SET' button for 5 seconds. The display will show 'P1'.
  2. Navigate Parameters: Press the 'SET' button repeatedly to cycle through parameters P1 to P10.
  3. Adjust Values: When a parameter (e.g., P1) is displayed, use the 'Up' (▲) and 'Down' (▼) arrow buttons to adjust its value.
  4. Save Settings: The device automatically saves the adjusted value after a few seconds of inactivity or when you press 'SET' to move to the next parameter.
  5. Exit Setting Mode: Continue pressing 'SET' until 'OFF' is displayed, then press 'SET' again to return to the normal display.

Parameter Descriptions:

  • P1: Over-Voltage Protection Value V (Range: 240-300V, Default: 270V)
  • P2: Over-Voltage Recovery Value V (Range: 235-295V, Default: 265V)
  • P3: Under-Voltage Protection Value V (Range: 140-200V, Default: 170V)
  • P4: Under-Voltage Recovery Value V (Range: 145-205V, Default: 175V)
  • P5: Over-Current Protection Value A (Range: 1-16A, Default: 16A)
  • P6: Power-on Delay Time S (Range: 1-300 seconds, Default: 5 seconds)
  • P7: Voltage Protection Recovery Delay Time S (Range: 5-300 seconds, Default: 30 seconds)
  • P8: Current Protection Recovery Delay Time S (Range: 30-300 seconds, Default: 30 seconds)
  • P9: Voltage Regulation (Range: -9.5% to +9.5%, Default: 0%) - For manual voltage error calibration.
  • P10: Current Regulation (Range: -9.5% to +9.5%, Default: 0%) - For manual current error calibration.

6.3. Video Demonstration

Watch this video for a visual guide on the product's features and how to adjust settings:

Video demonstrating the physical features and setting adjustments of the EARU EAMPS-1-VA protector.

7. Maintenance

  • Keep the device clean and dry. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to direct sunlight, high humidity, or corrosive environments.
  • Do not use harsh chemicals or abrasive cleaners.
  • Regularly check the plug and socket for any signs of wear or damage.

8. Troubleshooting

  • No Power Output / Red Light ON: This indicates the device is in protection mode due to over-voltage, under-voltage, or over-current. Check the input voltage and current. Power will resume automatically once conditions return to normal after the set recovery delay.
  • Device Not Turning On: Ensure the device is properly plugged into a live wall socket. Check the wall socket with another appliance.
  • Incorrect Voltage/Current Readings: If you suspect the readings are inaccurate, you can perform a manual calibration using parameters P9 (Voltage Regulation) and P10 (Current Regulation) in the setting mode.
  • Reset Electricity Meter Reading: To reset the accumulated electricity meter reading, press and hold the 'Down' arrow key for 10 seconds.
  • Restore Factory Default Parameters: In the setting mode, press and hold both the 'Up' (▲) and 'Down' (▼) arrow keys simultaneously for 3 seconds.

9. User Tips

  • For sensitive appliances like heating gas boilers with air turbines and water pumps, consider installing this protector after a dedicated surge filter for enhanced peace of mind.
  • Remember that this device is a voltage and current protector, not a circuit breaker designed to handle high inrush currents from faulty devices. It protects against grid fluctuations, not internal appliance faults.
  • Take time to understand the parameter settings to optimize protection for your specific appliances and local power conditions.

10. Warranty and Support

For detailed instructions, specifications, and troubleshooting, please refer to the official user manual PDF: EARU EAMPS-1 Series Protector Sockets User's Manual (PDF).

For technical support or inquiries, please contact the manufacturer:

ZHEJIANG OUYOU (EARU) ELECTRONICS CO.,LTD.
Address: YAMING ROAD 38, XIANGYANG INDUSTRY AREA, LIUSHI TOWN, YUEQING CITY, ZHEJIANG PROVINCE, CHINA
Manager: Bob Wu
Email: bob@earuelec.com
Phone Number: +86 15821639630

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.