1. Safety Instructions
Please read this instruction manual carefully before use and strictly observe the safety rules and the caution, attention, and warnings listed in this manual.
1.1. General Warnings
- If the voltage detector is not used according to the instructions, the protection function provided by the electric pencil may be affected or invalidated.
- Do not use if the display is not shown.
- Before using the voltage detector, always test it on a known live power supply to ensure it is in good working condition.
- Even if there is no indication or sound alarm, voltage may still be present. The detector indicates effective voltage when a sufficiently strong electrostatic field is generated. If the field strength is very weak, the detector may not detect voltage. Factors affecting detection include shielded wires/cables, insulation thickness and type, distance from voltage sources, complete insulators, and socket design.
- Do not use the voltage detector if it is damaged or unable to work properly. Before use, check that the probe tip is not cracked or broken. If there are any issues, send it for repair.
- Do not apply voltage exceeding the rated voltage marked on the detector.
- When testing voltages above 30V, exercise extreme caution due to the risk of electric shock.
- Comply with all local and national safety regulations and use appropriate personal protective equipment.
1.2. Battery Safety
- To avoid electric shock, ensure the battery cover is securely locked before performing any voltage detection.
2. Product Overview
The GVDA Non-Contact AC Voltage Detector is a versatile tool designed for electrical professionals and DIY enthusiasts. It offers non-contact AC voltage detection, breakpoint finding, and phase sequence detection (GD116B only).
2.1. Key Features
- Non-Contact AC Voltage Detection (12-1000V AC)
- Adjustable Sensitivity (High/Low)
- Breakpoint Detection
- Live/Neutral Wire Distinction
- Non-Contact Phase Sequence Detection (GD116B only)
- Sound and Light Alarm
- LED Flashlight
- Automatic Power Off
- Low Battery Indication
2.2. Components
- Inductive Probe
- Flashlight
- Signal Indicator
- Display Screen
- Power Button
- Sensitivity/Phase/Flashlight Button
- Battery Cover

The GVDA GD116C model showing the device, gift box, and user manual.
3. Setup
3.1. Battery Installation
The device requires two 1.5V AAA batteries (not included). To install or replace batteries:
- Rotate the battery cover (Component 7) to open the battery compartment.
- Remove any old batteries.
- Insert two new 1.5V AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Securely close the battery cover by rotating it back into place.
Note: Ensure the battery cover is fully closed and locked before use.
Video demonstrating the features and battery installation of the GVDA AC Voltage Detector.
4. Operation
4.1. Power On/Off
- To Power On: Press and hold the Power Button (Component 5) for more than 1 second. The device will beep, the screen will light up, and it will enter the test state.
- To Power Off: Press the Power Button (Component 5) while the device is on.
4.2. NCV Sensitivity Adjustment
The detector has two sensitivity modes: Low (Lo) and High (Hi).
- Upon powering on, the device defaults to Low Sensitivity (Lo), suitable for detecting voltage in the 48-1000V AC range.
- To switch to High Sensitivity (Hi), press the Sensitivity/Phase/Flashlight Button (Component 6) for less than 1 second. This mode is suitable for detecting voltage in the 12-1000V AC range, including cable breakpoint detection.

Diagram illustrating the sensitivity adjustment feature and voltage ranges.
4.3. LED Flashlight
The integrated LED flashlight is useful for working in dimly lit environments.
- To Turn On/Off: Press and hold the Sensitivity/Phase/Flashlight Button (Component 6) for more than 2 seconds.

The LED flashlight illuminates the work area for better visibility.
4.4. AC Voltage Detection
To detect AC voltage, place the inductive probe (Component 1) near the AC voltage source. The signal indicator (Component 3) will light up, and the bargraph on the display (Component 4) will increase or decrease with the signal intensity. The device will also emit beeps that become faster or slower depending on the signal strength. The backlight will change from green to red when a strong signal is detected.
- Live/Neutral Wire Distinction: Generally, a red backlight indicates a live wire, while a green backlight indicates a neutral or ground wire. If the backlight color change is not clear, distinguish based on signal intensity: a stronger signal usually indicates a live wire.
- Note: If live and neutral wires are close, separate them as much as possible for better distinction.
4.5. Breakpoint Detection
In High Sensitivity mode, the detector can identify breakpoints in cables. Move the probe along the cable; the detection will stop at the point where the circuit is broken.

Diagram showing the detector identifying a breakpoint in a cable.
4.6. Non-Contact Phase Sequence Detection (GD116B Only)
This feature is available only on the GD116B model to safely trace 3-phase rotation.
- After powering on, press the Sensitivity/Phase/Flashlight Button (Component 6) repeatedly (less than 1 second per press) until the display shows the rotating arrow symbol (↻) to enter phase sequence detection mode.
- The display will flash the 'A' symbol. Place the inductive probe (Component 1) against the first phase line and wait for a beep.
- The display will then flash the 'B' symbol. Place the probe against the second phase line and wait for a beep.
- The display will then flash the 'C' symbol. Place the probe against the third phase line and wait for a long beep.
- After the test, the display will show the measurement results: '↻' for left rotation or 'R' for right rotation.
- Important: Ensure the probe is firmly against the wire.
- Complete the test on all three wires within 1 minute to avoid a timeout error. If a timeout occurs, the red backlight will illuminate; press the Sensitivity/Phase/Flashlight Button to re-detect.
- If the three phase lines are very close, try to separate them for more accurate detection.

Diagram illustrating the non-contact phase detection feature, showing left and right rotation indicators.
5. Maintenance
5.1. Cleaning
Clean the voltage detector with a damp cloth. After cleaning, ensure the device is completely dry before storage or next use.
5.2. Battery Replacement
Refer to Section 3.1 for instructions on replacing batteries.
6. Troubleshooting
6.1. Automatic Power Off
The device will automatically power off after approximately 5 minutes of no signal detection or operation to conserve battery life.
6.2. Low Battery Indication
When the battery voltage drops below 2.5V, a battery symbol will appear on the display. If the voltage drops further to below 2.3V, the device will automatically shut down. Replace the batteries promptly when the low battery indicator appears.
6.3. Inaccurate or No Detection
- Ensure the device is powered on and in the correct sensitivity mode (Lo or Hi) for your application.
- Test the device on a known live circuit to confirm it is functioning correctly.
- Check for physical damage to the probe tip.
- Consider environmental factors such as shielded wires, thick insulation, or distance from the voltage source, which can affect detection accuracy.
7. Specifications
| Parameter | Value |
|---|---|
| NCV Detection Voltage Range | 12-1000V AC, 50/60Hz |
| Phase Detection Voltage Range | 90-400V AC, 50/60Hz |
| Operating Temperature | 0-40°C |
| Storage Temperature | -10-50°C |
| Humidity | ≤95% |
| Altitude | ≤2000m |
| Safety Compliance | CAT.IV 600V, CAT.III 1000V |
| Power Supply | 2 x 1.5V AAA Battery |
| Product Dimensions (approx.) | 16 cm (Length) x 4 cm (Width) x 3 cm (Height) |
| Product Weight (approx.) | 0.07 kg |
8. User Tips
- Always perform a quick test on a known live circuit (e.g., a wall outlet) before using the detector on an unknown circuit to ensure it's working correctly.
- When checking for breakpoints in a cable, switch to High Sensitivity mode for better accuracy.
- Utilize the built-in LED flashlight when working in poorly lit areas to improve visibility and safety.
- Be mindful that thick insulation or metal conduits can reduce the detector's sensitivity.
- For phase sequence detection, ensure the probe makes good contact with each phase line and follow the sequence carefully.
9. Frequently Asked Questions (FAQ)
Q: The detector is not beeping or lighting up when near a live wire. What should I do?
A: First, check if the batteries are installed correctly and have sufficient charge (refer to Section 6.2). Then, ensure the device is powered on and try switching between Low (Lo) and High (Hi) sensitivity modes (refer to Section 4.2). Also, consider if the wire is heavily shielded or if there's thick insulation, which can reduce detection. Always test on a known live circuit first.
Q: What do 'Lo' and 'Hi' mean on the display?
A: 'Lo' indicates Low Sensitivity mode, which is the default setting and suitable for detecting higher voltage ranges (48-1000V AC). 'Hi' indicates High Sensitivity mode, which is more sensitive and can detect lower voltage ranges (12-1000V AC), useful for breakpoint detection or weaker signals.
Q: How do I know if a wire is live or neutral?
A: When the detector's probe is near a live wire, the signal indicator will typically light up red, and the beeping will be more rapid. Near a neutral wire, the indicator might light up green, and the beeping will be slower or absent. For precise distinction, especially if wires are close, rely on the intensity of the signal and the color of the backlight (red for live, green for neutral/ground).
10. Additional Resources
For a comprehensive guide and further details, you may refer to the official user manual PDF: