vilnason 2180

Contents

Ultrasound Physiotherapy Device Instruction Manual

Brand: Vilnason | Model: 2180

Vilnason Ultrasound Physiotherapy Device and packaging

The Vilnason 2180 Ultrasound Physiotherapy Device, shown with its packaging.

1. Introduction

The Vilnason 2180 Ultrasound Physiotherapy Device is a new hand-held ultrasonic instrument designed to alleviate various kinds of chronic or acute pain. It features a fashionable appearance, easy operation, and a comfortable handle, making it suitable for personal and household use.

Ultrasound therapy is a natural and green therapy with no side effects, no radiation, and is non-toxic. It has been widely used for about 80 years in pain management and rehabilitation departments and is now available for home use. The continuous sound waves travel deep into the tissue, inducing vasodilation, increasing blood flow to the treated area, and helping to relieve pain and reduce muscle spasms.

The device is uniquely equipped with a soundhead pre-warming feature for increased patient comfort. Before therapy, the soundhead preheats to ensure a comfortable and warm application. Once therapy begins, the pre-warming feature turns off for effective treatment.

This portable therapeutic ultrasound unit is an excellent choice for non-invasive pain relief, similar to devices used in chiropractic or physical therapy offices.

2. Important Safeguards and Safety Precautions

General Safety

  • Please read this product manual carefully before use to avoid unnecessary harm.
  • Ultrasound is a high-frequency sound wave, which is not radioactive and will not harm the human body. It is safe for pregnant women and fetuses, and patients can use it with confidence.
  • Do not connect this device with other electronic instruments.
  • Do not use the device near other electronic devices to avoid interference.
  • Keep this equipment away from instruments that are easily affected by electromagnetic fields, as it may cause accidents.
  • Place the device out of reach of children and keep it in a safe place.
  • Do not place the device where water can splash.
  • Do not store the device in environments with extreme temperatures, high humidity, dust, salt, sulfur, or direct sunlight.
  • Do not place the device in a flammable environment, such as air containing a lot of oxygen, anesthetic gas, or other flammable gases.
  • Abide by local laws and regulations for the disposal of electronic waste.

Contraindications (Do NOT use if any of the following apply):

  • Patients with implantable electronic devices such as cardiac pacemakers.
  • Cannot be used with oxygen generators and artificial hearts.
  • The instrument is for standalone use and cannot be used together with electrocardiographs, high-frequency electrotomes, or other surgical equipment.
  • Patients with malignant tumors.
  • Hemophilia or hemorrhagic disease.
  • Patients with heart disease (especially those with implanted pacemakers or other implantable instruments).
  • Patients with acute infectious diseases or purulent wounds.
  • Individuals who have had deep X-ray therapy or radioisotope therapy.
  • Pregnant women.
  • Without proper examination by a physician.
Safety Precautions list

A visual summary of safety precautions.

3. Product Overview and Components

The ultrasonic physiotherapy instrument is mainly composed of a host unit, a 4.0 cm² therapeutic probe, and an adapter.

Key Function Definitions:

Diagram of device controls

Diagram illustrating the various parts and controls of the device.

  1. Time indicator
  2. Time selection key
  3. Power indicator
  4. Output mode indicator
  5. Output mode selection key
  6. Power switch
  7. Ultrasonic probe
  8. Power Supply
Close-up of device controls with labels

Detailed view of the control panel with power, time, and intensity settings.

4. Setup

The ultrasonic physiotherapy instrument is a hand-held medical equipment that does not require complex installation. It can be used by simply connecting the power adapter.

Connection Steps:

  1. Place the equipment on a flat and stable table to prevent tilting, vibration, or falling.
  2. Ensure the power switch of the device is in the "OFF" position before connecting.
  3. Insert the adapter interface into the socket of the power connection line on the device.
  4. Insert the adapter plug into a correctly rated power supply network (100-240V, 50/60Hz).
  5. Use only the medical adapter provided by the manufacturer to prevent damage to the instrument.

5. Operating Instructions

Always ensure the device is properly set up and safety precautions are observed before beginning treatment.

General Operation:

  1. **Apply Couplant:** Ultrasound couplant must be used during treatment. Apply enough couplant on the skin surface of the application site. The treatment head should be in full contact with the skin to ensure ultrasound penetration.
  2. **Power On:** Turn the power switch to the "ON" position.
  3. **Select Time:** Use the time selection key to choose your desired treatment duration (5, 10, or 15 minutes). The time indicator will illuminate.
  4. **Select Intensity:** Use the output mode selection key to choose the desired intensity level (Low, Medium, High). The output mode indicator will illuminate.
  5. **Apply Device:** Place the ultrasonic probe on the treatment area. For optimal results, keep the moving distance of the probe 1-2 cm per second. It can be moved in a circle or a straight line. Stay for approximately 30 seconds in one spot to allow the ultrasound wave to enter the skin surface.
  6. **Monitor Device:**
    • When the contact between the treatment head and the treatment site is good, the time indicator will be on for a long time.
    • If the contact is poor, the time indicator will flash once, reminding you to adjust placement or apply more couplant.
    • If the temperature of the treatment head exceeds 42°C, the time indicator will flash twice as a warning.
  7. **Treatment Duration:** Research suggests that 5-15 minutes is the most suitable time frame for ultrasound therapy. The appropriate dose depends on the type of pain and its depth:
    • **Low-end (Acute Pain, 0.5-2cm depth):** Use for acute pain with shallow depth.
    • **Mid-range (Acute Pain, 3-4cm depth):** Use for acute pain with moderate depth.
    • **Upscale (Chronic Pain, 2-4cm depth):** Use for chronic pain with moderate to deep penetration.
  8. **Power Off:** When the treatment is over, turn the power switch to the "OFF" position.
Device being used on a knee for pain relief

Applying the device to the knee for targeted pain relief.

Diagram showing ultrasound wave penetration into skin layers

Illustration of 1MHz ultrasound waves penetrating skin layers to a depth of 82mm for micro-massage.

Diagram explaining the working principle of ultrasound

Visual explanation of ultrasound's mechanical, warming, and chemical effects on body cells.

Chart showing recommended treatment times for different pain types

Guidance on selecting appropriate treatment duration based on pain type and depth.

Video Demonstration:

A short video demonstrating the use of the ultrasound physiotherapy device on various body parts.

6. Maintenance

  • After each treatment, remove the adapter and clean the treatment site and equipment.
  • Check the superconducting head for cracks and ensure the cable is safe before each use.
  • If the equipment has been stored for a period, ensure it functions normally and safely before use.
  • Check accessories often and wipe the superconducting head with a cotton cloth soaked in about 70% alcohol.
  • Do not store the device in environments with extreme temperatures, high humidity, dust, salt, sulfur, or direct sunlight.
  • Avoid placing the device in flammable environments (e.g., high oxygen, anesthetic gas).
  • Do not place the device where water can splash.
  • Dispose of electronic waste according to local laws and regulations.

7. Troubleshooting

  • **Allergic Reaction:** If an allergic reaction occurs during physical therapy, stop using the device immediately and consult a doctor.
  • **Overheating Warning:** If the treatment head temperature exceeds 42°C, the time indicator will flash twice. Stop use and allow the device to cool down.
  • **Poor Contact Indication:** If the time indicator flashes once, it indicates poor contact between the treatment head and skin. Adjust the device's position or add more ultrasound couplant.
  • **Device Not Working / No Vibration/Heat:** Ensure the device is properly connected to power and turned on. Verify that the correct time and intensity settings are selected. If a drop of water on the head does not move, it may indicate a malfunction.
  • **Device Not Turning On:** Check the power connection and ensure the power switch is in the "ON" position. If the device still does not turn on, it may be faulty.

8. Specifications

ParameterValue
Security ClassificationClass II BF application equipment
Operation ModeContinuous operation
Rated Voltage100-240V AC
Frequency50/60Hz
Adapter Output15V=1.2A
Acoustic Working Frequency1MHz ±10%
Rated Output Power4.8W ±20% (When duty cycle is 50%)
Maximum Output Power9.6W
Actual Output Power (Low Gear)2.88W ±20%
Actual Output Power (Medium Gear)3.84W ±20%
Actual Output Power (High Gear)4.80W ±20%
Maximum Sound Intensity of Beam9.6W/cm²
Pulse Repetition Rate100Hz ±10%
Duty CycleLow: 30%, Medium: 40%, High: 50%
Pulse Duration3ms, 4ms, 5ms
Pulse Repetition Period10ms
Ratio of Time Maximum Output Power to Output Power2, 2.5, 3.33
Usage Time5, 10, 15 minutes (three gears adjustable)
Effective Radiation Area (AER)4.0cm² ±20%
Effective Sound Intensity (Low Grade)0.72W/cm² ±20%
Effective Sound Intensity (Medium Grade)0.96W/cm² ±20%
Effective Sound Intensity (High Grade)1.20W/cm² ±20%
MaterialABS
ApplicationBODY
CertificationCE
Product Size (LxWxH)202mm x 49mm x 70mm
Weight700g
Waterproof GradeIPX7 (for ultrasonic probe only)
Product parameter table

Key product parameters for the device.

9. User Tips

  • **Always Use Couplant:** Ensure you always apply a sufficient amount of ultrasound couplant to the skin before and during treatment. This is crucial for effective ultrasound transmission and to prevent damage to the device or skin.
  • **Purchase Extra Gel:** The ultrasound device requires couplant for each use. Consider purchasing additional containers of ultrasound gel to ensure continuous treatment.
  • **Targeted Pain Relief:** The device is effective for various body pains, including shoulder, elbow, waist, knee, ankle, and wrist pain. Apply directly to the affected area.
  • **Monitor Contact:** Pay attention to the time indicator. If it flashes once, adjust the device's position or add more gel to ensure good contact.
  • **Adjust Intensity and Time:** Experiment with the three intensity levels and timing options (5, 10, 15 minutes) to find what works best for your specific pain type and depth.
  • **Portability:** The device is mini and portable, making it convenient for use at home or while traveling.
Two tubes of ultrasonic coupling gel

Example of ultrasonic coupling gel, essential for device operation.