1. Important Safety Instructions

Please keep this user manual properly for future reference!

Warning: It is essential to read, understand, and adhere to all safety instructions provided in this document. Failure to comply with safety regulations may result in property damage or personal injury.

Basic Guidelines

  1. Before using the equipment, carefully review all relevant sections of the device, battery, and instruction manual for all guidance and warning signs.
  2. Caution: To reduce the risk of injury, if you choose to use lead-acid batteries, please charge only deep cycle lead-acid batteries. Other types of lead-acid batteries may rupture, causing personal injury.
  3. This product does not contain user-serviceable parts. Do not disassemble the equipment. When maintenance or cleaning is required, take it to a qualified service center. Improper reassembly may pose risks of short-circuiting and fire. If any panel displays a malfunction, do not remove the front panel or operate the product. All operating procedures must be performed by trained professionals.
  4. To reduce the risk of electric shock, disconnect all wiring before performing any maintenance and cleaning. Switching off the main unit alone does not eliminate the risk of electric shock.
  5. Caution: Only qualified personnel should assemble the equipment with the battery.
  6. Charging frozen batteries is prohibited.
  7. Exercise extreme caution when using metal tools or placing them around the battery. Dropping tools can generate sparks or cause unpredictable risks such as short-circuiting the battery or other electronic components, potentially leading to explosions.
  8. When disconnecting AC or DC terminals, strictly follow the installation steps as outlined in the instruction manual's installation section.
  9. Before using this product, read the provided instructions to familiarize yourself with safety features and operating instructions. This product is designed and tested according to international standards. The equipment must be used exclusively for its intended purpose.

Installation Safety

  1. Do not use this product in areas where there is a risk of gas or dust explosions. Prior to use, consult with the battery manufacturer's relevant literature to ascertain the compatibility of this product with the battery. Always adhere to the safety instructions provided by the battery manufacturer.
  2. This is a safety-class product equipped with a protective grounding terminal. Continuous protective grounding must be provided by the AC input/output terminals.
  3. Grounding Instructions: The inverter/charger should be connected to a permanent grounding wire system to ensure full compliance with local requirements and regulations for installing the inverter. When grounding protection may have been compromised, the product must be shut down to prevent accidental electric shock.
  4. To ensure optimal operation of the inverter/charger, adhere to the required specifications and select appropriate cable sizes, which are crucial for the correct operation of the inverter/charger.
  5. Before connecting to the mains power, ensure that the available power supply meets the parameters specified in the product manual.
  6. Do not short-circuit the AC output and DC input. Do not connect the mains power when the DC output is short-circuited.
  7. Ensure that the equipment is used in conditions compliant with standards. Do not operate the product in moist or dusty environments. Ensure there is sufficient clearance space around the product and check that ventilation holes are not blocked.
  8. Ensure that the required system voltage does not exceed the capacity of the product.

Transportation and Storage

  1. Ensure that the power and battery cables are disconnected before storing or transporting the product.
  2. If the equipment is not in its original packaging during transportation, any transport damage is not the responsibility of the manufacturer.
  3. Store the product in a dry environment, with storage temperature between -25°C to 60°C.
  4. Refer to the battery manufacturer's manual for information on battery transportation, storage, charging, recharging, and disposal.

Please follow these instructions diligently to ensure safe installation, operation, transportation, and storage of the product.

2. About This Manual

This user manual provides information, operation, and maintenance guidance for the POW-SunSmart series inverter-charger integrated machines. The POW-SunSmart series products are all-in-one solar inverters developed by PowMr for solar energy storage systems, suitable for various residential or commercial applications.

Target Audience

This manual is intended for professional technical personnel involved in the installation, operation, and maintenance of solar inverter, as well as end-users seeking technical information.

Manual Usage

  1. Before using the product, carefully review this user manual and keep it stored in an easily accessible location.
  2. All information in the user manual, including images and symbols, is the property of PowMr. Unauthorized use of any portion or all of the content is prohibited for individuals outside the company.
  3. Considering the possibility of updates and revisions to the manual content, users are advised to use the accompanying manual as a reference. For the latest user manual, users can visit the official website or contact customer service.

3. Product Overview

The POW-SunSmart series is a new type of solar energy storage inverter. It integrates solar charging, utility charging and energy storage with AC sine wave output. It adopts DSP control and utilizes advanced algorithms to deliver fast response, high reliability, and industrial-grade performance. This series is ideal for demanding industrial applications.

PowMr 12KW Hybrid Solar Inverter with key features

Figure 3.1: PowMr 12KW Hybrid Solar Inverter. Key features include 12KW, 110V, 48VDC, 200A Max. Hybrid Current, Max 550V 6600W PV input, and 1-year warranty. Model: POW-SunSmart LVM12K.

Features

  • Supports lead acid battery and li-ion battery connections.
  • Dual activation function for dormant li-ion batteries (mains/PV power supply).
  • Support single-phase pure sine wave output.
  • Supports six different voltage levels of 100/105/110/115/120/127Vac per phase.
  • Supports two solar inputs and simultaneous tracking of two solar maximum power charging/loading capacity functions.
  • Dual MPPT with 99.9% efficiency and maximum 25A current in a single circuit, adapted to high power modules.
  • 2 charging modes: solar only, grid/solar hybrid charging.
  • Time-slot charging and discharging setting function for mains charging cut-in/out and battery discharging/mains bypass power supply.
  • Energy saving mode to reduce no-load energy losses.
  • Two output modes: utility bypass and inverter output, with uninterrupted power supply.
  • LCD large screen dynamic flow diagram for easy system data and operation status understanding.
  • 360° protection: short circuit, over current, over/under voltage, overload, backfill protection.
  • Support CAN, USB, and RS485 communication.

System Connection Diagram

The diagram below shows the system application scenario of this product. A complete system consists of PV modules, Utility grid or generator, Battery, Home load, and the Inverter.

System connection diagram and inverter dimensions

Figure 3.2: System Connection Diagram and Inverter Dimensions. The inverter is 750mm high, 440mm wide, and 240mm deep. It supports Pure Sine Wave, 50/60Hz Auto, and Lithium Battery. Output Voltage: 120Vac/208Vac/240Vac. Max Charge Current: 200A. Max PV Array Power: 12000W. PV Array MPPT Voltage Range: 120VDC~550VDC.

Product Components Overview

The inverter features various terminals and indicators for comprehensive system management.

Front view of PowMr Hybrid Solar Inverter

Figure 3.3: Front view of the PowMr Hybrid Solar Inverter, showing the display screen and branding.

Dimensions

The physical dimensions of the inverter are crucial for planning installation space.

DimensionValue
Height750 mm (780 mm total with mounting brackets)
Width440 mm (499 mm total)
Depth240 mm (143 mm main body)
Weight52 KG

4. Setup (Installation)

Mounting Location

The POW-SunSmart series can be used outdoors (protection class IP65). Consider the following before selecting the location:

  • Choose a solid wall for installation.
  • Mount the inverter at eye level.
  • Adequate heat dissipation space must be provided.
  • Installation location should be cool and ventilated, under a photovoltaic panel or eaves, avoiding direct sunlight.
  • Ambient temperature should be kept between -25°C and 60°C (-13°F and 140°F) for optimal operation.

DANGER: Do not install the inverter where highly flammable materials are nearby, in potential explosive areas, or with lead-acid batteries in a confined space.

CAUTION: Do not install the inverter in direct sunlight.

Mounting the Inverter

Drill four mounting holes in the wall according to specified dimensions (280mm horizontal, 556mm vertical spacing). Insert four M8*60 expansion bolts into the holes.

Terminal Cover & Anti-Insect Net Removal

Use a screwdriver to remove the fan shroud and open the cover. The fan cover is removable for cleaning.

NOTICE: When using the device in areas with poor air quality, clean the fan cover regularly to prevent blockage, which can trigger over-temperature protection (19/20 faults) and affect power supply and inverter lifespan.

Connections

Split-Phase Mode

The inverter supports split-phase output (120V-N-120V for 240V L1-L2) and single-phase output (120V L1-N).

Split-phase and single-phase wiring diagrams

Figure 4.1: Split-phase mode (default) provides 120V-N-120V for 240V AC output (L1-L2). Single-phase mode provides 120V AC output (L1-N).

Cable & Circuit Breaker Requirements

Ensure correct cable diameters and circuit breaker specifications for PV input, battery, AC input, generator input, and AC output.

ConnectionModelCable DiameterMax. CurrentCircuit Breaker Spec
PV Input8KW/10KW/12KW6mm² / 10AWG25A2P-25A
Battery8KW53mm² / 0AWG200A2P-250A
10KW/12KW67mm² / 00AWG230A (10KW), 270A (12KW)2P-250A
AC Input / Generator Input / AC Output8KW/10KW/12KW13mm² / 6AWGN/A3P-63A

GRID & LOAD & GEN Connection

Connect the live, neutral, and ground wires according to the cables' position and order shown in the diagram. Use a stripper to remove 6-8mm insulation and fix a ferrule (for PV/AC/GEN) or cable lugs (for Battery) at the end of the cable.

Battery Connection

Connect the positive and negative cable of the battery. Ensure the circuit breaker is open before connecting. Connect terminals correctly (not reversed).

PV Connection

Connect the positive and negative wires of both PVs. The positive wire runs through the AFCI unit. Ensure the open circuit voltage of PV modules in series does not exceed 550V.

Dry Contact Connection

Use a small screwdriver to push back the direction indicated by the arrow, then insert the communication cable (0.2~1.5mm²) into the dry contact port. This port has functions for RSD power supply, temperature sampling, and generator remote start/stop.

Grounding Connection

Ensure the grounding terminal connects to the Grounding Busbar. The grounding cable should have a diameter of not less than 4mm² and be as close as possible to the grounding point.

Inverter Start

After ensuring reliable wiring and correct wire sequence, follow these steps to start the inverter safely:

  1. Close the circuit breaker of the battery.
  2. Press the rocker switch on the bottom of the inverter; the screen and indicators will light up.
  3. Sequentially close the circuit breakers for PV, AC input, and AC output.
  4. Install the terminal protection cover in place.
  5. Start the loads one by one in order of power from small to large.

5. Operating

Operation and Display Panel

The operation and display panel includes 1 LCD screen, 3 indicators (AC/INV, CHARGE, FAULT), and 4 touchable keys (Enter/Exit, Next, Previous, Confirm).

Display Panel Overview

The LCD displays real-time system status, including solar panel output, battery status, load consumption, grid/generator status, inverter operation, local time, energy saving mode, and energy flow direction.

View Real-Time Data

On the LCD home screen, click the inverter icon, battery icon, mains icon, load icon, and photovoltaic icon to view real-time data for machine state, battery data, grid data, load data, PV data, and historical data.

Settings

Access settings from the menu bar to configure basic settings, work mode, battery parameters, on-grid settings, and advanced options.

  • Basic Setup: Language, RS485 Address, Screen always on, Beep, Screen brightening time, Backlight brightness, Time, Password.
  • Work Mode Setup: Hybrid grid mode (On grid, Limit power to ups/home load, AC Coupling), PV energy manage (First to load/charging/grid), Grid charging enable, Battery energy manage (Standby, Battery to ups/home load, Battery to grid sell), Parallel mode (stand-alone, Parallel), Grid type (Single/Three/Split Phase), Output phase voltage (100V-127V).
  • Peak Shaving: Timed charging/discharging enable, Start/End Time, Stop SOC, Stop Volt, Max Power.
  • Battery Setup: Battery Type (User define, SLD, FLD, GEL, LFP, Ternary), Battery chg. curr. limit, BMS comm. interface, Battery Temperature Compensation, Battery Manage (Max chg. voltage/current, Batt. Recharging voltage, Battery curr. stop chg., Batt volt. stop dchg/restart dischg, Battery under volt. alarm, etc.).
  • On Grid Setup: Grid standard, Grid frequency, CT ratio, Sell power Max, Buy power Max, Zero-export power, On-Grid Reactive Power, Reactive power over/under excited, On Grid PF, Power factor over/under excited.
  • Advanced Setup: Generator settings (Max charging current by gen., Generator rate power, Generator charging enable, Generator work mode, Grid always to smart load enable), Other settings (PE-N connect enable, PV Riso check enable, AFCI check enable, Leakage curr. protection enable, BMS comm. error stop, Power saving mode, CT auto detect enable, CT manual setting, Arc fault clear, Load type, Inverter current limiting coefficient), Restart Inverter (Restore to factory setting, Restart inverter).

Time-Slot Charging/Discharging Function

This function allows users to set different charging and discharging periods based on local peak and valley tariffs to optimize utility power and PV energy usage. This maximizes savings by using battery power during expensive utility rates and charging from cheap utility power.

Time-slot utility charging and battery discharging function

Figure 5.1: Cost-Effective Power Distribution with Definable Time-Slot. This diagram illustrates solar generation, energy usage, battery charging, and battery discharging patterns throughout a 24-hour cycle, optimized by time-slot utility charging and battery discharging functions.

Battery Parameters

Configurable parameters for lead-acid and li-ion batteries include Overdisconnect Voltage, Boost charging voltage, Undervoltage alarm/disconnect voltage, Discharge limiting voltage, Overdischarge delay time, and Enhanced Charge Cycle.

6. Communication

Overview

The inverter supports various communication ports for monitoring and control.

USB-B Port

Used to read and modify device parameters via host software. Contact support for the software installation package.

WIFI Port

Connects to a Wi-Fi/GPRS data acquisition module (purchased separately) for mobile APP monitoring.

RS485 Port

Connects to the BMS of Li-ion batteries.

CAN Port

Connects to the BMS of Li-ion batteries. Contact support for communication protocols or firmware upgrades if needed.

External CT Port

Used for current transformer connection (CT direction is normally