Hantek CC-65 CC-650 CC-800

Contents

Hantek AC/DC Current Clamp Meter User Manual

Models: CC-65, CC-650, CC-800

Introduction

The Hantek AC/DC Current Clamp Meter is a transducer designed to measure current data for multimeters and enable oscilloscopes to display current waveforms. It allows for direct current measurement up to 65A (CC-65) or 650A (CC-650/CC-800) with varying frequency bandwidths, without the need to break the circuit. This manual provides essential information for the safe and effective use of your current clamp meter.

Hantek CC-65 AC/DC Current Clamp Meter with BNC adapter and carrying case
Hantek CC-65 AC/DC Current Clamp Meter with included accessories.

Setup

Unboxing and Initial Inspection

Upon receiving your current clamp meter, carefully unbox all components. The package typically includes the current clamp, a user manual, and BNC adapters for oscilloscope connection. Inspect the device for any visible damage.

Video demonstrating the unboxing and initial setup of the Hantek Current Clamp.

Battery Installation

The current clamp requires a 9V DC battery (NEDA 1604, 6F22, 006P type). To install the battery:

  1. Locate the battery compartment on the back of the device.
  2. Use a screwdriver to open the battery cover.
  3. Connect the 9V battery to the battery clips, ensuring correct polarity.
  4. Place the battery inside the compartment and close the cover securely.
Diagram showing battery compartment and BNC connector on the current clamp
Location of the battery compartment and BNC connector.

Connecting to a Multimeter or Oscilloscope

For multimeters:

  1. Insert the black banana plug into the COM jack and the red banana plug into the V-Ω jack of your multimeter.

For oscilloscopes:

  1. Connect the BNC connector of the probe to a BNC input on your oscilloscope.

Operating Instructions

Power On and Zero Adjustment

  1. Set the power switch from "OFF" to "ON". The green LED will light up, indicating the probe is on.
  2. Before measuring DC current, it is essential to perform a zero adjustment. Turn the zero adjustment knob on the probe until your multimeter or oscilloscope reads zero. For best results, open and close the jaws several times before zeroing to eliminate any hysteresis effect.

Selecting Measurement Range

The current clamp offers different ranges depending on the model:

  • CC-65: 1mV/10mA (for 10mA to 2A) or 1mV/100mA (for 100mA to 65A).
  • CC-650/CC-800: 1mV/10mA or 1mV/100mA (for higher current ranges up to 650A/800A).

Select the appropriate range using the switch on the device. The corresponding multimeter range should be set to 200mV AC or 200mV DC, depending on the type of current being measured.

Measuring Current

  1. Ensure the probe is powered on and zero-adjusted (for DC measurements).
  2. Open the jaws of the current clamp.
  3. Place the jaws around the current-carrying conductor. Ensure the conductor is centered within the jaws for accurate readings.
  4. Read the current data from your connected multimeter or observe the waveform on your oscilloscope.
Hantek CC-65 current clamp with BNC adapter and specifications
CC-65 standard configuration and basic specifications.
Oscilloscope displaying current waveforms measured by the Hantek current clamp
Example of current waveforms displayed on an oscilloscope.

Interpreting Readings

  • 1mV/10mA Range: The actual current is 10 times the measured current (in mA). E.g., 10mV measured = 100mA actual.
  • 1mV/100mA Range: The actual current is 100 times the measured current (in mA). E.g., 5mV measured = 500mA actual.

Maintenance

Battery Replacement

The device features a Low Battery Indicator (red LED). When the battery is low, replace it with a new 9V DC battery (NEDA 1604, 6F22, 006P type). Typical battery life with alkaline batteries is 100 hours.

Cleaning and Storage

Keep the device clean and free from dust. Store it in a dry environment within the recommended temperature range of -20°C to +70°C (80% R.H.).

Troubleshooting

Inaccurate DC Current Zeroing

If the current probe does not zero properly during DC current measurement, it may be due to the hysteresis effect. To resolve this, open and close the jaws several times and then perform the zero adjustment again.

Specifications

Attribute Value
Brand NameHantek
Model NumberCC-65 CC-650 CC-800
Display TypeDigital Only
DIY SuppliesElectrical
OriginMainland China
CertificationCE
Battery IncludedNo
High-concerned chemicalNone
Dimensions21.5 * 11 * 5cm / 8.46 * 4.33 * 1.97in (CC-65)
Operating Temperature0°C to 50°C, 70% R.H.
Storage Temperature-20°C to +70°C, 80% R.H.
Supply Voltage110V 220V (for external power, device uses 9V battery)
Battery Type9V DC, NEDA 1604, 6F22, 006P
Battery Life100 hours typical with alkaline
Weight250 gram typical
OutputCoil cable with straight banana plug or BNC plug
Captured Conductor Size (CC-65)9mm maximum
Captured Conductor Size (CC-650/CC-800)30mm maximum

Accuracy (at 23±5°C, 70% R.H. maximum)

Measurement Type Machine Gear Measurement Range Accuracy Range AC Frequency
DC Current (CC-65)1mV/10mA10mA ~ 20A±(1.5%±5mA)N/A
1mV/100mA100mA ~ 40A±(2%±20mA)N/A
40A ~ 65A±(4%±0.3A)N/A
AC Current (CC-65)1mV/10mA100mA ~ 10A±(2%±30mA)40Hz ~ 2KHz
100mA ~ 10A±(4%±30mA)2KHz ~ 10KHz
100mA ~ 10A±(6%±30mA)10KHz ~ 20KHz
10A ~ 15A±(8%±30mA)40Hz ~ 20KHz
AC Current (CC-65)1mV/100mA200mA ~ 40A±(2%±30mA)40Hz ~ 1KHz
200mA ~ 40A±(4%±30mA)1KHz ~ 2KHz
200mA ~ 40A±(6%±30mA)3KHz ~ 5KHz
40A ~ 65A±(8%±0.3A)40Hz ~ 20KHz
DC Current (CC-650)1mV/100mA100mA ~ 200A±(1.5%+50mA)N/A
1mV/1A1A ~ 200A±(2%+0.5A)N/A
200A ~ 650A±(4%+2A)N/A
AC Current (CC-650)1mV/100mA100mA ~ 100A±(3%±0.5A)50Hz ~ 400Hz
1mV/1A100A ~ 150A±(8%±1A)50Hz ~ 400Hz
1A ~ 500A±(3%±2A)50Hz ~ 400Hz
DC Current (CC-800)10mV/A1A ~ 40A±(1.5%+0.5A)N/A
1mV/A1A ~ 800A±(1.5%+0.5A)N/A
AC Current (CC-800)10mV/A1A ~ 40A±(2%+0.5A)0Hz ~ 500Hz
1mV/A1A ~ 500A±(2%+0.5A)0Hz ~ 5KHz
Load Resistance10kΩ Typical
Temperature coefficient0.1×(defined accuracy) per degree C (0°C to 18°C, 28°C to 50°C)

User Tips

  • 9V batteries can drain quickly; consider having spares or rechargeable options if you use the device frequently.
  • The current clamp can be used with an oscilloscope to visualize current waveforms, which is useful for diagnosing issues like shorted motor windings (indicated by upward current spikes).
  • For precise DC current measurements, always perform the zero adjustment after opening and closing the jaws a few times to minimize hysteresis effects.

Warranty and Support

This product complies with the requirements of the European Community Directives: 89/336/EEC (Electromagnetic Compatibility) and 73/23/EEC (Low Voltage) as amended by 93/68/EEC (CE marking).

For any technical support or warranty claims, please refer to the contact information provided by your retailer or the official Hantek website. A user manual in PDF format is available for detailed information: User Manual (PDF).