1. Product Overview
This handheld refractometer, branded SONGGER, is designed for measuring the concentration of cutting fluids, coolants, lubricants, and other industrial emulsions. It utilizes an optical prism system with Automatic Temperature Compensation (ATC) to provide fast and reliable concentration readings. This instrument is suitable for various industrial applications including industrial maintenance, metal processing, automotive service, textile production, and laboratory analysis.

2. Specifications
| Parameter | Specification |
|---|---|
| Measuring Range | 0-10%, 0-20%, 0-32%, 0-50%, 0-80%, or 0-90% (model dependent) |
| Core Material | Aluminum / Copper |
| Prism Material | High-Definition Glass Prism |
| Power Supply | None required for standard optical model; optional 3 × LR44 batteries for backlight version |
| Rated Voltage (battery version) | 4.5 V DC |
| Temperature Compensation | Automatic at 20°C |
| Calibration Point | Metal Calibration Point |
| Applicable Media | Cutting fluid, lubricating oil, quenching liquid, cleaning agents, mining emulsions, textile additives, antifreeze, biological fluids (model dependent) |
Note: Calibration liquid is not included. Distilled water or certified standard solution should be used for calibration.
3. Product Features
- Wide Measurement Range: Supports multiple concentration levels (0-10%, 0-20%, 0-32%, 0-50%, 0-80%, 0-90%) to suit diverse testing requirements.
- Automatic Temperature Compensation (ATC): Ensures accurate readings by automatically correcting values when the liquid temperature deviates from 20°C. This reduces errors caused by temperature variations and improves measurement accuracy.
- High-Definition Glass Prism: Equipped with a high-definition glass prism for good light transmission, delivering sharp, accurate, and clearly visible measurements.
- Durable Metal Construction: Built with a pure copper or aluminum body for long-lasting use, comfortable touch, solid texture, and resistance to corrosion.
- No Power Required (Optional Battery): The standard optical model operates manually without external power. Optional LR44 batteries can be used to illuminate the scale for enhanced readability.
- Non-slip Foot Pad: Features a non-slip rubber sleeve design for a more stable grip, ensuring safe and reliable handling.





4. Application Fields
This refractometer serves as a reliable assistant for testing various industrial agents, including:
- Lubricating oil concentration
- Cutting fluid concentration
- Quenching liquid concentration
- Solid content of cleaning agents
- Serum protein
- Urine specific gravity
- Antifreeze freezing point
- Mining emulsions
- Textile additives

5. Principle of Operation
The refractometer operates on the principle of light refraction. When light passes from one medium to another, it changes speed and direction, an effect known as refraction. The degree of refraction is dependent on the concentration of dissolved solids in the liquid. The instrument measures this refractive index and correlates it to the concentration of the sample solution, displayed on a calibrated scale.

6. Setup and Calibration
Preparation
- Ensure the prism surface is clean and dry.
- If using the battery version, install three LR44 batteries correctly according to polarity markings.
- Allow the instrument and test liquid to reach ambient temperature before measurement.
Calibration
- Open the cover plate and place a few drops of distilled water onto the prism.
- Close the plate gently to spread the liquid evenly without bubbles.
- Point the instrument toward a light source and look through the eyepiece.
- Adjust the metal calibration screw until the blue-white boundary line aligns with zero on the scale.
- Wipe the prism clean with a soft cloth after calibration.

7. Operating Instructions
Measurement
- Place a few drops of the sample solution onto the prism surface.
- Gently close the cover plate to ensure even distribution and no bubbles.
- Aim the light-receiving plate of the instrument toward a light source or a bright area.
- Observe through the eyepiece and finely adjust the focus wheel until the blue-white boundary is clearly visible.
Data Reading
The measured value corresponds directly to the selected percentage scale. Read the value at the boundary line between the light and dark fields. Ensure the correct measuring range model is used for the intended application.



8. Precautions
- Operate within the specified measuring range of the selected model.
- Do not immerse the instrument in water.
- Avoid mechanical shock or dropping the device.
- Clean the prism immediately after each use to prevent corrosion or residue buildup.
- For battery models, remove batteries during long-term storage to prevent leakage.
- Do not use on highly corrosive or strongly acidic/alkaline liquids unless compatibility is confirmed.
- Use only LR44 batteries of the same type and replace all batteries simultaneously.
- This instrument is intended for industrial and laboratory use only.
- Improper handling of industrial fluids may cause skin or eye irritation. Wear appropriate personal protective equipment.
- Do not expose the device to strong acids, alkalis, or solvents that may damage the prism or housing.
- Batteries may present a a choking hazard and chemical risk. Keep out of reach of children.
9. Storage and Maintenance
- Store the instrument in a dry and dust-free environment.
- Keep away from direct sunlight and extreme temperatures.
- Clean the prism using a soft lint-free cloth. Do not use abrasive materials.
- Periodically check calibration accuracy using distilled water.
- If optical clarity decreases, inspect the prism surface for contamination.
10. Troubleshooting
If you encounter issues with your refractometer, consider the following:
- Inaccurate Readings: Ensure the instrument is properly calibrated with distilled water. Verify the sample liquid is at ambient temperature (ideally 20°C) for optimal ATC performance. Check for any residue or damage on the prism surface.
- Unclear View: Clean the eyepiece and prism thoroughly with a soft, lint-free cloth. Adjust the focus wheel until the blue-white boundary is sharp. Ensure sufficient light is directed towards the light-receiving plate.
- No Backlight (battery models): Check if LR44 batteries are installed correctly and are not depleted. Replace all batteries simultaneously if needed.
- Liquid Spreading Issues: Ensure the cover plate is gently closed to spread the liquid evenly without air bubbles. Use only a few drops of the sample.
For persistent issues, please contact customer support.
11. User Tips
- The ideal measuring temperature is 20°C. The Automatic Temperature Compensation (ATC) feature will automatically adjust the reading if the sample temperature varies, but allowing the sample to reach ambient temperature can improve consistency.
- This device does not strictly require a power supply for operation. However, using optional LR44 batteries can illuminate the scale, making readings easier to see, especially in low-light conditions.
- Beyond industrial fluids, this refractometer is also capable of accurately measuring biological fluids such as serum protein and urine specific gravity, depending on the specific model's range.
- Always use distilled water or a certified standard solution for calibration to ensure the highest accuracy of your measurements.
12. Warranty and Support
Compliance Disclaimer
This document is provided for product instruction purposes only and does not constitute legal advice. The seller is responsible for ensuring compliance with all applicable EU directives and local regulations, including WEEE Directive 2012/19/EU for electronic waste recycling and proper disposal of used batteries according to EU Battery Directive requirements.
Contact Information
For technical consultations, bulk orders, or any support inquiries, please feel free to contact us:
- WhatsApp: +86 13311678550
- Email: miazhao008@gmali.com