1. Product Overview
The KeepLiNK Industrial Ethernet Switch is engineered for robust performance in demanding industrial settings. It offers excellent industrial quality with features like vibration resistance, high/low temperature tolerance, dustproof design, and surge protection. The fanless heat dissipation circuit, wide operating temperature range, and high protection grade ensure reliability. This switch integrates various protocols for routing, switching, and security, enhancing networking flexibility and improving the reliability and security of industrial networks. It is suitable for deployment in rail transit, smart cities, intelligent transportation, outdoor monitoring, and other challenging environments.
This 8-Port Megabit Ethernet Switch provides reliable 10/100 Mbps Fast Ethernet connectivity. Key features include:
- 8 x 10/100 Mbps RJ45 ports (Auto-MDI/MDIX, auto-negotiation)
- Industrial-grade metal casing (IP40 protection)
- DIN-rail mounting
- Wide operating temperature: -40°C to 75°C
- Dual power inputs (12-48V DC) with reverse polarity protection
- Low power consumption & fanless design (silent operation)
- Store-and-forward switching with 1Gbps backplane bandwidth
- EMI/ESD protection for stable performance in noisy environments
- Plug-and-play, no software configuration required
Figure 1.1: KeepLiNK Industrial 8-Port 10/100 Mbps Ethernet Switch
2. Specifications
| Feature | Description |
|---|---|
| Brand Name | keepLiNK |
| Model Number | KP-9000-45-8TXm |
| Switch Type | Fast Switch |
| Number of Interfaces | 9 (8 Ethernet ports + 1 power input) |
| Transmission Rate | 10/100Mbps |
| Switch Capacity | 32G |
| Communication Mode | Full-Duplex & Half-Duplex |
| VLAN Support | Yes |
| Function | VLAN Support |
| Certification | CE, FCC, RoHS |
| Housing | Aluminum, IP40 |
| Dimensions | 91 x 95 x 41 mm (3.58 x 3.74 x 1.61 in) |
| Input Voltage | Redundant 12-58VDC |
| Installation | 35mm Standard DIN-Rail Mounting |
Figure 2.1: Industrial Unmanaged Switch Specifications
3. Setup
3.1 Device Installation (DIN-Rail Mounting)
The Industrial Ethernet switch is designed for DIN rail installation. Follow these steps:
- Tilt the device upwards. Ensure the clasp on the upper end of the device hooks onto the DIN rail.
- Press the device downwards until the lower end of the buckle securely latches into the DIN rail.
- Verify that the installation is stable and the device is firmly attached to the DIN rail.
Figure 3.1: DIN-Rail Installation Diagram
3.2 Power Input and Wiring
The industrial Ethernet switch features dual power backup for enhanced reliability. When both power supplies are connected, only one operates. If the active power supply fails, the switch automatically transitions to the other power supply, providing redundant protection.
The power wiring connections are detailed in the table below:
| Terminal | Description |
|---|---|
| P1+ | First circuit power supply positive pole |
| P1- | First circuit power supply negative pole |
| P2+ | Second circuit power supply positive pole |
| P2- | Second circuit power supply negative pole |
| P1/P2- | First and second circuit share a negative pole |
| + | Positive pole of power supply |
| - | Negative pole of power supply |
Note:
- Connect the positive and negative poles according to the Phoenix terminal markings.
- Ensure the input voltage is within the specified range (generally DC10-58V, refer to the side cover for exact details).
- Only one power supply will be actively working at a time.
Figure 3.2: Power Terminal Block and Ports
Figure 3.3: Top View with Power Input
Figure 3.4: Power Terminal Block and LED Indicators
3.3 PoE Line Sequence Introduction
This device supports Power over Ethernet (PoE) according to 802.3AF and 802.3AT standards. For PoE connections, the switching power supply should be between DC 48V and DC 58V. The PoE connection must be consistent with the network cable connection, utilizing pins 1, 2, 3, and 6 for both data transmission and PoE power supply.
4. Operation
4.1 Indicator Lamp Meaning
The device features various indicator lamps to provide status information. Refer to the table below for their meanings:
| Indicator Lamp | State | Meaning |
|---|---|---|
| P/P1/P2/PS1/PS2/PWR (Power lamp and power supply under-voltage alarm lamp) | Flashes uniformly (1s period) | Power supply is below DC10V (under-voltage alarm) |
| Off | Power channel is not powered | |
| On | Power channel is powered | |
| O/OPT (Fiber-port lamp and power supply overvoltage alarm lamp) | Flashes uniformly (0.5s period) | Power supply exceeds DC58V (overpressure alarm) |
| Off | Fiber port not connected | |
| On | Fiber port is connected | |
| Flash | Fiber port is connected and data is sent/received | |
| A/ALM (Device alarm lamp and data transmission indicator lamp) | On | Device has alarms (Temperature, LFP, Dying-gasp) |
| Flashes (Console/RS232/RS485 data) | Console/RS232/RS485 is sending data | |
| N/NMC (Management indicator lamp and data receiving indicator lamp) | Off | No embedded module |
| On | Embedded module present and initializing | |
| Flash (Console/RS232/RS485 data) | Console/RS232/RS485 is receiving data | |
| RUN (Running indicator lamp) | On | Device works normally |
| Off | Device is not running | |
| Flash | Device software loading | |
| 1000Mbps copper port indicator lamp | Green (Active) On | Port is connected |
| Green (Active) Off | Port not connected | |
| Green (Active) Flash | Port is connected and data is sent/received | |
| Yellow (SPD) On | 1000M is connected | |
| Yellow (SPD) Off | 10/100M is connected | |
| 100Mbps copper port indicator lamp | Green (Active) On | Port is connected |
| Green (Active) Off | Port not connected | |
| Green (Active) Flash | Port is connected and data is sent/received | |
| Yellow (SPD) On | 100M is connected | |
| Yellow (SPD) Off | 10M is connected | |
| Reset/configurate push-button | Long press (> 20s) | Restore factory setup / restart |
4.2 DIP Switch Configuration (Unmanaged Devices)
For unmanaged devices, the DIP switches allow for specific configurations. Refer to the table below:
| DIP Switch | Function | ON State | OFF State |
|---|---|---|---|
| Bit1 (LFP C/D) | LFP C/D | Enable remote PD reset function (for 1 fiber and 1 copper switch) | Turn off remote PD restart function |
| Bit2 (LGY) | LEGACY function switch | Supports standard and non-standard PD power supply | Only supplies power to standard PD, does not support non-standard PD power supply |
| Bit3 (VLAN) | Port Isolation function | Enable port isolation function | Turn off port isolation function |
| Bit4 (BSR/RST) | BSR: Storm Control | Enable storm control | Turn off storm control |
| Bit4 (BSR/RST) | RST: Remote PD Reset Every Day function | Resets the remote PD device after 24 hours | Turn off this function |
5. Maintenance
To ensure optimal performance and longevity of your Industrial Ethernet Switch, follow these maintenance guidelines:
- Regular Inspection: Periodically check the device for any physical damage, loose connections, or excessive dust accumulation.
- Cleaning: Use a soft, dry cloth to clean the exterior of the device. Do not use liquid cleaners or solvents. Ensure ventilation openings are clear of obstructions.
- Environmental Control: Maintain the operating environment within the specified temperature range (-40°C to 75°C) and humidity levels to prevent overheating or moisture damage.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure the device has the latest features and security patches.
- Power Supply Check: Verify that the power input is stable and within the 12-48V DC range. Inspect power cables for wear or damage.
6. Troubleshooting
This section provides guidance for common issues. Refer to the Indicator Lamp Meaning table (Section 4.1) for diagnostic assistance.
- No Power (PWR LED Off):
- Check power cable connections to the Phoenix terminal.
- Verify the power source is active and providing 12-48V DC.
- Ensure the power supply is functioning correctly.
- Under-voltage Alarm (PWR LED Flashing 1s):
- The input voltage is below DC10V. Check the power supply output and connections.
- Overpressure Alarm (O/OPT LED Flashing 0.5s):
- The input voltage exceeds DC58V. Immediately disconnect power and check the power supply output. Using an incorrect power supply can damage the device.
- No Link on Ethernet Port (Port LED Off):
- Check the Ethernet cable connection at both ends.
- Ensure the connected device is powered on and functioning.
- Try a different Ethernet cable or port.
- Device Not Running (RUN LED Off):
- Verify power is supplied and stable.
- If the device is unresponsive, perform a factory reset (long press the Reset button for >20s).
- General Alarms (A/ALM LED On):
- This indicates a temperature alarm, LFP alarm, or Dying-gasp alarm. Check the operating environment for excessive heat. Consult the full user manual (PDF) for specific alarm codes if available.
7. Warranty and Support
KeepLiNK provides a comprehensive warranty for this Industrial Ethernet Switch. Please retain your purchase invoice and certificate of three guarantees for warranty claims.
7.1 Warranty Period
- Initial Period (7 days from sale): You may choose to repair, replace, or return the equipment if the entire unit fails.
- Extended Period (8th to 15th day from sale): If there is any performance failure, you may choose to repair or replace the entire unit.
- Standard Warranty (2 years): The company provides a 2-year warranty from the date of sale. This can be extended to 5 years according to the contract.
If the hardware warranty period is exceeded, the user will bear the cost of replacing hardware, and no additional fees will be charged by the company.
7.2 Other Service Commitments
Within one year from the date of purchase, if the equipment cannot be repaired within 30 days due to unavailability of spare parts, or if the equipment failure persists after two repairs, the company will replace the unit with the same type and specification free of charge. In unusual circumstances where an engineer cannot resolve the problem, a service engineer will negotiate with you for the return of the equipment for repair. After repair, the equipment will be sent back to you free of charge.
7.3 Circumstances Not Covered by Warranty
Failure or damage to equipment (including parts) under the following circumstances are not covered by warranty:
- Accessories supplied by other companies (e.g., power supply, adapter) are guaranteed by their respective manufacturers.
- The entire machine and parts have exceeded their warranty period.
- Equipment failure or damage caused by unauthorized repair, alteration, or demolition by personnel not from KeepLiNK.
- Malfunctions caused by accidental or artificial causes, including improper operation, scratching, handling, moving, knocking, or inputting inappropriate voltage.
- Failure or damage caused by the use of non-genuine or unpublished software.
- Failures or losses caused by natural disasters or force majeure (e.g., earthquakes, fires).
For further details, please refer to the official user manual PDF: KeepLiNK Industrial Ethernet Switches User Manual (PDF)
8. User Tips
- Verify Power Input: Always double-check your power supply voltage (12-48V DC) before connecting to prevent damage, especially when using PoE.
- Secure Mounting: Ensure the DIN-rail mounting is firm and stable to withstand industrial vibrations.
- Environmental Considerations: While rugged, avoid exposing the switch to extreme conditions beyond its specified operating range to maximize its lifespan.
- Cable Management: Use proper cable management to prevent accidental disconnections and ensure optimal airflow around the device.