1. Product Introduction
The PUSR USR-DR124 is a new generation LoRa wireless data transmission DTU (Data Transfer Unit) developed based on the Sx128x chip. This ultra-compact 2.4GHz LoRa modem is equipped with an RS485 port, enabling transparent transmission between RS485 and LoRa. It supports multiple data transmission modes and includes advanced features such as LoRa signal detection and LBT (Listen Before Talk) detection. The USR-DR124 is designed for high cost performance, strong anti-interference capabilities, and stability, making it ideal for various on-site serial device data transmission applications.
Key Features
- "Lipstick" Size: Ultra-compact design for space-saving installation.
- FLRC/LoRa Modulation: Supports both high/low speed and medium/long distance transmission.
- High-Power Transmission: Optional 12/27dBm output, allowing for wireless transmission distances of 5-8 kilometers.
- 2.4GHz Frequency Band: Operates in the global license-free 2.4GHz - 2.5GHz frequency bands.
- DIN Rail Mounting: Convenient and quick installation on DIN rails.
- Modbus Transparent Transmission: Simple to use for Modbus data.
- Relay Networking: Extends wireless transmission distance and improves data penetration.
- Wide-temperature Operation: Designed for stable operation in harsh environments from -40℃ to +85℃.
- Remote Configuration: Supports AT commands and configuration utility for remote parameter setting.
- Watchdog Protection: Built-in hardware watchdog ensures stable and reliable operation.
- Wide Voltage Power Supply: Accepts DC 8-24V input.
- Flame Retardant Rating: V0 flame-retardant material for enhanced safety.
- Easy Connection: Features push-type, pluggable wire connectors for simple wiring without additional tools.
Application Scenarios
- Wireless smart metering industry
- Wireless control of smart street lights
- Smart agricultural systems, intelligent irrigation remote control
- Smart site equipment monitoring, tower crane operation status monitoring
- Smart oil field, oil well condition monitoring
- Smart home and industrial sensors
- Power distribution cabinet power detection, computer room monitoring
- Intelligent building energy monitoring
2. Specifications
| Category | Specification Parameters | Parameter Range |
|---|---|---|
| Wireless Parameters | Wireless Solution | Sx128x |
| Modulation Mode | LoRa/FLRC | |
| Operating Frequency Band | 2.4GHz-2.5GHz | |
| Transmission Power | USR-DR124-27: 27±1dBm USR-DR124-12: 12±1dBm |
|
| Receiver Sensitivity | -140dBm @0.268Kbps | |
| Operating Mode | Point-to-point, point-to-multipoint transmission | |
| Transmission Distance | 27dBm maximum distance: 8000m @rate 1 12dBm maximum distance: 5000m @rate 1 |
|
| Serial Port | RS485: 1200bps - 921600bps | |
| Operating Voltage | 8V-24V, 12V recommended | |
| Operating Current | Transmitting current: 45mA @12V; Receiving current: 11mA @12V | |
| Hardware Parameters | Weight | 34g |
| Operating Temperature | -40℃ ~ +85℃ | |
| Operating Humidity | 10~90%RH (no condensation) | |
| Antenna Option | SMA antenna connector (external thread, internal hole) with rod antenna | |
| Watchdog | Built-in hardware watchdog |
3. Setup and Installation
3.1. Hardware Interface Description
The USR-DR124 features a compact design with clearly labeled interfaces for easy setup.
Terminal Block (RS485 & Power)
The device uses a push-type, pluggable wire connector for RS485 communication and power input. This design simplifies wiring, eliminating the need for additional tools like screwdrivers.
- RS485: Connects to 485 serial port devices. A connects to A, B connects to B.
- Power Input: DC 8-24V (12V recommended).
- GND: Ground connection.
Antenna Interface
The device features an SMA antenna connector (external thread, internal hole) for connecting the included rod antenna.
Indicator Lights
| Name | Function Description | Instruction |
|---|---|---|
| POW | Power indicator | Illuminates steadily when the power input is correct. |
| WORK | Working indicator | Blinks with a 2-second cycle during normal operation; stays on after network access. |
| COM | Serial data indicator | Red and green lights blink alternately when there is serial data communication (red for TX, green for RX) during data transmission. |
| LINK | Signal quality indicator for LoRa and FLRC signals | Red (LoRa): Steady on for excellent signal; blinks every 1s for good signal; blinks every 3s for poor signal. Green (FLRC): Steady on for excellent signal; blinks every 1s for good signal; blinks every 3s for poor signal. |
Factory Reset Button
When the LoRa data transmission terminal is in normal working state (Work light flashes normally), press and hold the factory reset button for 3-15 seconds. Release the button when the TXD light flashes once. This action restores the setting parameters of the LoRa data transmission terminal to the factory configuration.
3.2. Physical Installation
The USR-DR124 is designed for DIN-Rail mounting, making it easy to integrate into industrial control cabinets.
3.3. Initial Configuration
The USR-DR124 can be configured using the dedicated Upper Computer Configuration Software. This software allows for parameter reading and configuration via a serial port connection.
Note: The device does not come pre-configured and requires initial setup using the provided software. The software can be downloaded from the official PUSR website: https://www.usr.cn/Download/1294.html
4. Operating Modes
The USR-DR124 supports various data transmission modes to suit different application requirements.
4.1. Transparent Data Transfer
In transparent transmission mode, the device transmits data without altering its content. Both the sender and receiver must be configured with the same modulation mode, working frequency band, communication rate, and communication address. This allows for seamless wireless data transmission between two or more devices.
4.2. Broadcast Data Transmission
When configured for broadcast mode, any data sent by one device will be received by all other devices in the network. Both transmitting and receiving devices should be set to broadcast mode with the same modulation mode, frequency band, and communication rate.
4.3. Fixed-point Data Transmission
This mode enhances transparent transmission by using the first two bytes of transmitted data as the destination address (high byte first) and the third byte as the channel identifier. The device dynamically modifies these parameters during transmission and reverts them afterward. This allows for flexible adjustment of destination addresses and channels, enabling seamless configuration changes for target modules.
4.4. Master-slave Data Transfer
In master-slave mode, one master device distributes data to multiple slave devices. The master sends data to specific slave devices according to a defined protocol (Slave Target Address (16-bit) + Data). Slave devices send data directly to the master without following the data transmission protocol.
4.5. Relay Networking
The relay networking function extends transmission distance and improves data penetration. Devices configured in relay mode forward data, allowing for multi-level relay networking. This is suitable for ultra-long-range or complex environments and supports multiple networks in the same region.
4.6. Command Mode (AT Commands)
In Command Mode, users can query the module’s current status or set parameters by sending AT commands or using the configuration software. To enter AT command mode, send "+++" via UART, wait for the confirmation code "a", then send "a" again. The module will respond with "+OK" to confirm entry into AT command mode.
A comprehensive list of AT commands is available in the user manual PDF for detailed configuration options.
5. Advanced Features
5.1. LoRa Signal Detection
The signal detection function helps determine interference in the operating frequency band and assess signal quality during data transmission, aiding in optimal device placement and parameter selection.
- Current Channel Environment Detection: A single device detects interference in the current working band, outputting SNR (Signal-to-Noise Ratio) and RSSI (Received Signal Strength Indicator) values to determine signal quality.
- Data Transmission Signal Detection: During data transmission between multiple devices, the received data carries SNR and RSSI values to determine the signal quality of the current data transmission.
5.2. LBT (Listen Before Talk)
The LBT function actively monitors channel environment noise before sending data. If noise exceeds a threshold, data transmission is delayed until the channel is clear. This significantly improves communication success rates in noisy environments and helps prevent collisions.
5.3. Data Retransmission
This feature ensures data transmission success in challenging environments. It activates a response mechanism where the sender waits for feedback after transmitting data. If no response is received within a timeout period, the transmission is considered failed and will be attempted again, with a maximum of three retransmissions. Note that retransmission is not supported in relay mode.
5.4. Remote Configuration
The USR-DR124 supports remote configuration of parameters using upper-level computer software and AT instructions. This includes remote search of node configurations and specified node ID configurations, simplifying debugging and maintenance of remote devices.
6. Maintenance
6.1. High Reliability Design
The USR-DR124 is built with high reliability in mind to ensure long-term stable operation:
- V0 Flame-Retardant Material: The casing is made from V0 flame-retardant material, which stops burning within 10 seconds on a vertical part, preventing the spread of fire.
- Wide Operating Temperature: Operates reliably in extreme temperatures from -40℃ to +85℃.
- Independent Hardware Watchdog: A built-in watchdog monitors the system and automatically restarts the device in case of abnormal operation, ensuring continuous service.
- EMC Protection: Designed with Electromagnetic Compatibility (EMC) protection to minimize interference and ensure stable performance in industrial environments.
6.2. Environmental Considerations
To ensure optimal performance and longevity, avoid using the device in environments with extremely low temperatures, or where short circuits might occur due to water accumulation or corrosive gases.
7. Troubleshooting
7.1. Unideal Transmission Distance
- Antenna Placement: If the antenna is placed inside a metal enclosure or in a basement, the signal will be attenuated, resulting in a shorter transmission distance. Ensure the antenna is positioned for optimal signal reception.
- Obstacles: Too many obstacles in the line of sight can attenuate the signal.
- Environmental Factors: Heavy fog or rainy days can affect signal transmission, leading to high packet loss rates.
- Mounting Height: Testing near the ground often yields poor results. The device generally needs to be at least 2 meters above the ground for best performance.
- High Rate Settings: If the communication rate is set too high, the spreading factor and bandwidth may be inappropriate, reducing transmission distance.
- Antenna Matching: Poor matching between the antenna and the module or inadequate antenna gain can lead to a short communication distance.
7.2. Equipment Damage
- Power Supply: Ensure the power supply meets the recommended voltage (DC 8-24V). Exceeding the maximum value can damage the equipment.
- Anti-static Protection: During installation and use, pay attention to anti-static measures, especially in high-frequency environments.
- Power Stability: Use a stable power supply. Large fluctuations can cause damage.
- Environmental Exposure: Avoid environments with extremely low temperatures, water accumulation, or corrosive gases.
7.3. Slow Data Transmission Speed
- Communication Rate: A lower communication rate results in slower transmission speed but longer transmission distance. Conversely, a higher rate provides faster speed but shorter distance. Adjust the rate according to your needs.
- Serial Port Baud Rate: Using a serial port with a low baud rate can also lead to slow data transmission.
7.4. Interference in Data Transmission
- Other Devices: If other devices operate in the same frequency band nearby, change the communication channel or move the device away from the interference source.
- Antenna Quality: Poor antenna feeder or extension line quality can lead to signal transmission errors.
- Noise: Large-scale noise generated on the bottom board can interfere with data reception.
- Power Supply Settings: Unreasonable power supply settings that do not meet regulations can result in garbled codes.
8. Firmware Upgrade
To upgrade the firmware of your USR-DR124 device, follow these steps:
- Open the Upper Computer Configuration Software (select USR-DR124).
- Connect the device to your computer via the serial port.
- Click to enter configuration mode within the software.
- Manually enter
AT+BOOT=1to activate serial port upgrade mode, or set the device's Reload pin to low and power it on to enable serial port upgrade mode. - Select the corresponding serial port in the software.
- Open the provided upgrade firmware file (*.hex).
- Click "Download" and wait for the download to complete.
Note: Serial port upgrades may cause parameters to revert to factory settings. It is recommended to save your current configuration before proceeding. The configuration software can be downloaded from https://www.usr.cn/Download/1294.html.
9. User Tips
- Verify Configuration: Always double-check your configuration settings, especially modulation mode, frequency band, and communication rate, to ensure proper communication between devices.
- Antenna Optimization: For best results, ensure the antenna is securely attached and positioned in an open area, ideally at least 2 meters above the ground, to maximize transmission distance.
- Software for Setup: The device requires configuration using the dedicated software. Make sure to download the latest version from the official PUSR website for optimal functionality.
- Quality Assurance: The product is designed for good quality and reliable operation. If you encounter any issues, refer to the troubleshooting section or contact support.
10. Frequently Asked Questions (FAQ)
- Q: Does this equipment come pre-configured?
- A: No, the USR-DR124 does not come pre-configured. You will need to use the provided configuration software to set up the parameters according to your application requirements.
- Q: Where can I get the configuration software?
- A: The configuration software can be downloaded from the official PUSR website: https://www.usr.cn/Download/1294.html.
11. Warranty and Support
11.1. Disclaimer
This document provides information about PUSR's LoRa series products. It does not grant any intellectual property license, either expressly or impliedly. PUSR shall not be liable for any other liabilities beyond those stated in the sales terms and conditions of its products. PUSR makes no express or implied warranties regarding the suitability for a specific purpose, merchantability, or infringement of any patent or copyright. Product specifications and descriptions may be modified at any time without further notice.
11.2. Contact Information
- Official Website: www.pusr.com
- Official Shop: shop.usriot.com
- Technical Support: h.usriot.com
- Inquiry Email: inquiry@usriot.com
- Skype & WhatsApp: +86 13405313834
For additional guides and documents, including the user manual in PDF format, please refer to the official PUSR website. The PDF manual can be found at: User manual (PDF).
12. PUSR IoT Factory Production Process
Watch this video to see the advanced manufacturing processes at PUSR IoT, ensuring high-quality and reliable products.