Contents

PowMr Hybrid 2.4KW Solar Inverter User Manual

Model: PS-3K-110V

Brand: PowMr

1. Introduction

This PowMr Hybrid Solar Inverter is a multi-function inverter/charger, integrating the capabilities of an inverter, solar charger, and battery charger. It is designed to provide uninterruptible power support in a compact form factor. The unit features a comprehensive LCD display and user-friendly buttons for configuring settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges to suit various applications.

Features

  • Pure sine wave inverter
  • Configurable input voltage range for home appliances and personal computers via LCD setting
  • Configurable battery charging current based on applications via LCD setting
  • Configurable AC/Solar Charger priority via LCD setting
  • Compatible with mains voltage or generator power
  • Auto restart while AC is recovering
  • Overload/ Over temperature/ short circuit protection
  • Smart battery charger design for optimized battery performance
  • Cold start function

System Application

The inverter can power various home and office appliances, including motor-type loads like tube lights, fans, refrigerators, and air conditioners. It integrates with solar panels, a generator or utility power, and a battery bank to supply power to your home appliances.

System Application Diagram
Figure 1: Hybrid Power System Application. This diagram illustrates how solar panels, a generator, or utility power can feed into the inverter, which then charges a battery and powers home appliances.
Play video
Watch video online
Video 1: PowMr Hybrid Solar Inverter Product Showcase. This video provides a 360-degree view of the inverter, highlighting its design, display, and various connection ports.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION - Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
  10. Fuses (4 pieces of 40A, 32VDC for 1KVA/2KVA, 6 pieces of 40A, 32VDC for 3KVA, 1 piece of 200A, 64VDC for 4KVA and 5KVA) are provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
  12. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

3. Setup and Installation

3.1. Product Overview and Ports

Familiarize yourself with the inverter's display, indicators, and connection ports before installation.

Inverter Ports and Display Labels
Figure 2: Inverter Front and Rear Panel Layout.
Front Panel: 1. LCD display, 2. Status indicator, 3. Charging indicator, 4. Fault indicator, 5. Function buttons.
Rear Panel: 6. Circuit breaker, 7. AC input, 8. Dry connect, 9. PV input, 10. ON/OFF switch, 11. AC output, 12. RS232 Communication port, 13. DC input/Battery input.

3.2. Unpacking and Inspection

Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain:

  • The inverter unit x 1
  • User manual x 1
  • Communication cable x 1
  • Software CD x 1

3.3. Preparation

Before connecting any wiring, remove the bottom cover by unscrewing the two screws as shown in the manual's diagrams.

3.4. Mounting the Unit

Consider the following points when selecting a mounting location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install the inverter at eye level for easy LCD display readability.
  • For proper air circulation and heat dissipation, allow a clearance of approximately 20 cm to the sides and 50 cm above and below the unit.
  • The ambient temperature should be between $0^{\circ}C$ and $55^{\circ}C$ for optimal operation.
  • The recommended installation position is vertical wall mounting.
  • Ensure sufficient space for heat dissipation and wire removal.

CAUTION: Suitable for mounting on concrete or other non-combustible surfaces only.

3.5. Battery Connection

CAUTION: For safety and compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the typical amperage table in the manual for fuse or breaker sizing.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable sizes for battery connections to ensure system safety and efficient operation.

Battery Voltage Compatibility:

  • 1KVA models support 12VDC systems.
  • 2KVA/3KVA models support 24VDC systems.
  • 4KVA/5KVA models support 48VDC systems.

Connect all battery packs as per the diagrams in the manual. It is recommended to connect at least 100Ah capacity for 1-3KVA models and at least 200Ah capacity for 4KVA/5KVA models. Use only sealed lead-acid or sealed GEL/AGM lead-acid batteries.

Insert the battery cable ring terminal flatly into the inverter's battery connector and tighten the bolts with a torque of 2-3 Nm. Ensure correct polarity at both the battery and inverter/charger.

Multiple Battery Compatibility
Figure 3: Multiple Battery Compatibility. The inverter is compatible with Flooded, AGM, Gel, and Sealed Lead Acid Batteries.

3.6. AC Input/Output Connection

CAUTION: Before connecting to AC input, install a separate AC breaker between the inverter and the AC input power source. This ensures safe disconnection and over-current protection. Do NOT mis-connect input and output connectors.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable sizes for AC input connections.

Follow these steps:

  1. Before making AC input/output connections, open the DC protector or disconnector first.
  2. Remove 10mm of insulation sleeve for conductors. Shorten phase L and neutral conductor N by 3mm.
  3. Insert AC input wires according to polarities indicated on the terminal block and tighten screws. Connect PE protective conductor (yellow-green) first, then LINE (brown or black), and Neutral (blue).
  4. Insert AC output wires according to polarities and tighten screws.
  5. Ensure all wires are securely connected.

3.7. PV Connection (Solar Charger Models Only)

CAUTION: Before connecting PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable sizes for PV module connections.

When selecting PV modules, ensure the open circuit voltage (Voc) of PV modules does not exceed the max. PV array open circuit voltage of the inverter. The max. power voltage (Vmpp) of PV modules should be close to the inverter's best Vmp for optimal performance.

Follow these steps:

  1. Remove 10mm of insulation sleeve for positive and negative conductors.
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive (+) to positive (+) and negative (-) to negative (-).
  3. Ensure all wires are securely connected.

3.8. Communication Connection

Use the supplied communication cable to connect the inverter to a computer. Install the monitoring software from the bundled CD. Refer to the software user manual on the CD for detailed operation.

3.9. Final Assembly

After connecting all wiring, replace the bottom cover and secure it with the two screws.

4. Operation

4.1. Power ON/OFF

Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

4.2. Operation and Display Panel

The operation and display panel is located on the front of the inverter. It includes three indicators, four function keys, and an LCD display, providing operating status and input/output power information.

LED IndicatorColorStatusMessages
AC/INVGreenSolid OnOutput is powered by utility in Line mode.
FlashingOutput is powered by battery or PV in battery mode.
CHGGreenSolid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRedSolid OnFault occurs in the inverter.
FlashingWarning condition occurs in the inverter.
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

4.3. LCD Display Icons

The LCD displays various icons indicating input source, configuration, fault information, output status, and battery status. Refer to the manual for a detailed explanation of each icon.

4.4. LCD Setting

To enter setting mode, press and hold the ENTER button for 3 seconds. Use UP/DOWN buttons to select programs and ENTER to confirm or ESC to exit. Detailed settings for charging current, input voltage range, power saving mode, battery type, auto restart, output frequency, and voltage points are available in the manual.

4.5. Display Setting

Pressing the UP or DOWN key cycles through various display information on the LCD, including input voltage, input frequency, PV voltage, charging current, battery voltage, output voltage, output frequency, load percentage, load in Watt, load in VA, DC discharging current, and CPU versions.

4.6. Operating Mode Description

The inverter operates in several modes:

  • Standby / Power Saving Mode: No output, but can charge batteries.
  • Fault Mode: Indicates internal errors or external issues.
  • Line Mode: Provides output power from mains and charges the battery.
  • Battery Mode: Provides output power from battery and PV power.
Charging and Output Modes
Figure 4: Charging & Output Modes. This image details the four charging modes (Solar First, Utility First, Solar and Utility, Only Solar) and three load output working modes (Utility First, Solar First, SBU First).

5. Maintenance

To ensure optimal performance and longevity of your PowMr Hybrid Solar Inverter, regular maintenance is recommended:

  • Cleaning: Regularly inspect the inverter for dust accumulation, especially on cooling vents. Use a soft, dry cloth to clean the exterior. Ensure the unit is powered off and disconnected from all power sources before cleaning.
  • Airflow: Ensure proper airflow around the unit. Do not block the ventilation openings.
  • Connections: Periodically check all electrical connections (battery, AC input/output, PV input) to ensure they are tight and free from corrosion. Loose connections can lead to poor performance or safety hazards.
  • Battery Health: Monitor the health of your battery bank. Ensure batteries are properly maintained according to their manufacturer's guidelines.
  • Professional Service: For any internal issues, unusual noises, or persistent fault indicators, contact qualified service personnel. Do not attempt to open or repair the inverter yourself.

6. Troubleshooting

This section provides solutions to common issues you might encounter with your inverter. Refer to the table below for problem descriptions, possible causes, and recommended actions.

ProblemLCD/LED/BuzzerExplanation / Possible causeWhat to do
Unit shuts down automatically during startup process.LCD/LEDs and buzzer will be active for 3 seconds and then complete off.The battery voltage is too low (<1.91V/Cell)1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. The battery voltage is far too low. (<1.4V/Cell)
2. Battery polarity is connected reversed.
1. Check if batteries and the wiring are connected well.
2. Re-charge battery.
3. Replace battery.
Input voltage is displayed as 0 on the LCD and green LED is flashing.Input protector is trippedCheck if AC breaker is tripped and AC wiring is connected well.
Mains exist but the unit works in battery mode.Green LED is flashing.Insufficient quality of AC power. (Shore or Generator)1. Check if AC wires are too thin and/or too long.
2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS/Appliance)
When the unit is turned on, internal relay is switched on and off repeatedly.Green LED is flashing.Set "Solar First" as the priority of output source.Change output source priority to Utility first.
LCD display and LEDs are flashingBattery is disconnected.Check if battery wires are connected well.
Fault code 07Overload error. The inverter is overload 110% and time is up.Reduce the connected load by switching off some equipment.
Output short circuited.Check if wiring is connected well and remove abnormal load.
Fault code 05Temperature of internal converter component is over 120°C. (Only available for 1-3KVA models)Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.
Fault code 02Internal temperature of inverter component is over 100°C.
Battery is over-charged.Return to repair center.
Buzzer beeps continuously and red LED is on.Fault code 03The battery voltage is too high.Check if spec and quantity of batteries are meet requirements.
Fault code 01Fan faultReplace the fan.
Fault code 06/58Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac)1. Reduce the connected load.
2. Return to repair center
Fault code 08/09/53/57Internal components failed.Return to repair center.
Fault code 51Over current or surge.Restart the unit, if the error happens again, please return to repair center.
Fault code 52Bus voltage is too low.
Fault code 55Output voltage is unbalanced.
Fault code 56Battery is not connected well or fuse is burnt.If the battery is connected well, please return to repair center.

7. Specifications

7.1. Line Mode Specifications

ParameterSpecification
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage180Vac±7V (UPS); 100Vac±7V (Appliances)
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

7.2. Inverter Mode Specifications (PS-3K-110V)

ParameterSpecification (2.4KW Model)
Rated Output Power3KVA/2.4KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50Hz
Peak Efficiency90%
Overload Protection5s@≥150% load; 10s@110%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage24Vdc
Cold Start Voltage23.0Vdc
Low DC Warning Voltage (@ load < 20%)22.0Vdc
Low DC Warning Voltage (@ 20% ≤ load < 50%)21.4Vdc
Low DC Warning Voltage (@ load ≥ 50%)20.2Vdc
Low DC Warning Return Voltage (@ load < 20%)23.0Vdc
Low DC Warning Return Voltage (@ 20% ≤ load < 50%)22.4Vdc
Low DC Warning Return Voltage (@ load ≥ 50%)21.2Vdc
Low DC Cut-off Voltage (@ load < 20%)21.0Vdc
Low DC Cut-off Voltage (@ 20% ≤ load < 50%)20.4Vdc
Low DC Cut-off Voltage (@ load ≥ 50%)19.2Vdc
High DC Recovery Voltage29Vdc
High DC Cut-off Voltage31Vdc
No Load Power Consumption<20W
Saving Mode Power Consumption<10W

7.3. Charge Mode Specifications

ParameterSpecification
Charging Algorithm3-Step
Utility Charging Mode AC Charging Current20/30Amp (@VI/P=230Vac)
Bulk Charging Voltage (Flooded Battery)29.2V
Bulk Charging Voltage (AGM / Gel Battery)28.2V
Floating Charging Voltage27Vdc
Solar Charging Mode Charging Current (PWM)50Amp
Solar Charging Mode System DC Voltage24Vdc
Solar Charging Mode Operating Voltage Range30~32Vdc
Solar Charging Mode Max. PV Array Open Circuit Voltage60Vdc
Standby Power Consumption1W
DC Voltage Accuracy+/-0.3%
Joint Utility and Solar Charging Max Charging Current50Amp
Joint Utility and Solar Charging Default Charging Current50Amp

7.4. General Specifications

ParameterSpecification
Safety CertificationCE
Operating Temperature Range0°C to 55°C
Storage temperature-15°C~60°C
Dimension (D*W*H), mm100 x 272 x 355
Net Weight, kg6.9

8. User Tips

  • Wiring Integrity: Always ensure all wiring is correctly sized according to specifications and securely connected. Loose or undersized wiring can lead to performance degradation, overheating, and potential safety hazards.
  • Monitoring: Regularly monitor the LCD display for operational status, battery charge levels, and any warning or fault indicators. Addressing issues promptly can prevent further damage.
  • Ventilation: Maintain clear space around the inverter to ensure adequate ventilation and prevent overheating.

9. Warranty and Support

For warranty information and technical support, please contact your original point of purchase or the PowMr customer service. Keep your purchase receipt as proof of purchase.

10. Appendix: Approximate Back-up Time Table

The following table provides approximate back-up times for various loads and battery configurations. Note that actual back-up time depends on battery quality, age, and type.

10.1. 3KVA Model Back-up Time

Load (VA)Backup Time @ 24Vdc 100Ah (min)Backup Time @ 24Vdc 200Ah (min)
3004491100
600222525
900124303
120095227
150068164
180056126
210048108
24003594
27003174
30002867