Gaqqee Lithium Battery Capacity Tester

Contents

Gaqqee 8 Channel 18650 Lithium Battery Auto Charge Discharge Tester Instruction Manual

Safety Tips (Very Important!)

  • Use a DC 12-19V power supply with sufficient power (recommended 19V, 4.7A, 90W). A 5V power supply is not supported. Insufficient power can prevent normal operation.
  • The 18650 battery holder is only for flat-head 18650 batteries. It is not suitable for pointed-head 18650 or other battery specifications. Adjust spring pieces for tightness before use.
  • This equipment is not suitable for charging lithium iron phosphate batteries. Lithium iron phosphate batteries can only be tested in discharge mode. Charging, automatic, and active modes are prohibited for these batteries.
  • Do not perform power-on tests with damaged or leaking batteries.
  • The active mode is a forced charging mode. Non-professional personnel should not use it, and personnel should not leave the device unattended during use.
  • Heat will be generated during charging and discharging. Keep away from flammable materials during use!

Product Overview

The Gaqqee 8 Channel 18650 Lithium Battery Auto Charge Discharge Tester is a versatile device designed for comprehensive battery analysis. It features an 8-channel design, allowing independent testing of multiple 18650 lithium batteries simultaneously. The device supports both ternary iron and lithium iron phosphate battery tests (with specific mode limitations for LiFePO4).

Key features include a 2.4-inch color display for clear data visualization, adjustable charging and discharging parameters, and active heat dissipation with temperature-controlled fans. It supports various operating modes including automatic charge/discharge, charge-first-then-discharge, discharge-first-then-charge, charge-only, discharge-only, and activation mode.

Front view of the 8-channel battery tester
Front view of the 8-channel battery tester, showing battery slots, fans, and display.

Technical Specifications

Feature Specification
Product Name 2.4" TFT 8-channel 18650 battery tester
Model Number Lithium Battery Capacity Tester
Working Voltage DC 12-19V (standard bare machine, without power supply)
Power Supply Interface DC 5.5 high current interface (DC 5.5x2.1mm)
Channel Type 8 independent channels
Charging (Stop) Voltage 3.7V, 3.8V, 3.9V, 4.0V, 4.1V, 4.2V (6 gears adjustable)
Recharge (Stop) Voltage 3.0V to 4.2V (13 gears adjustable)
Charging Current Each channel independent, approx. 1A (not adjustable)
Charging End Current 100mA, 200mA, 300mA (adjustable)
Discharge Current Each channel independent, approx. 1A (not adjustable)
(Discharge) Stop Voltage 2.0V to 3.6V (17 gears adjustable)
Standstill Time 1-5 minutes (adjustable)
Display 2.4-inch color display with curve graphing capability
Heat Dissipation Active heat dissipation (temperature-controlled fans)
Overheat Protection Supported
Battery Reverse Connection Protection Provided, reverse connection prohibited
Product Size 310mm x 102mm x 42mm (12.2in x 4.01in x 1.65in)
Product Weight 410g (bare machine) / 500g (including packaging)
Side view of the battery tester with dimensions
Side view of the battery tester with dimensions.

Setup Instructions

  1. Power Supply Connection: Connect a DC 12-19V power supply (e.g., 19V, 4.7A, 90W adapter) to the DC 5.5x2.1mm power input interface. Ensure the power supply meets the voltage and current requirements to avoid malfunction.
  2. Close-up of the DC power input port (5.5x2.1mm)
    DC 5.5x2.1mm power input port. Must use DC 12-19V/60W power supply.
  3. Battery Installation: Install flat-head 18650 batteries into the designated battery holders (CHN1-CHN8). Pay close attention to the positive (+) and negative (-) poles to ensure correct orientation. Do not install batteries in reverse. Adjust the spring piece in the holder if necessary for a snug fit.
  4. Close-up of the 18650 battery holder
    Test Cell Holder for 18650 Battery. Ensure correct polarity.
  5. Power On: Once the power supply is connected, the device will automatically power on and display the overview interface.

Video Guide: Initial Setup and Battery Installation

Play video
Watch video online

This video demonstrates powering on the device, installing batteries, and navigating the initial display.

Operating Modes

The tester offers several operating modes to suit different testing needs:

  • AUTO (Automatic Mode): Performs a full cycle of charging, then discharging, then stops.
  • CHG (Charging Mode): Charges the battery until the set stop voltage is reached, then stops.
  • DSG (Discharge Mode): Discharges the battery until the set stop voltage is reached, then stops.
  • ACTI (Activation Mode): A forced charging mode. Use with caution and do not leave unattended. Not suitable for LiFePO4 batteries.
  • Charge First, Then Discharge: Charges the battery, then discharges it, then stops.
  • Discharge First, Then Charge: Discharges the battery, then charges it, then stops.

Mode Flow Illustrations:

Flowchart for AUTO mode
Flowchart illustrating the Automatic (AUTO) mode operation.
Flowchart for CHG mode
Flowchart illustrating the Charging (CHG) mode operation.
Flowchart for DSG mode
Flowchart illustrating the Discharging (DSG) mode operation.
Flowchart for ACTI mode
Flowchart illustrating the Activation (ACTI) mode operation.

Interface Display

The device features a 2.4-inch color display that provides real-time information and allows for easy navigation and setting adjustments.

Front View Components:

Detailed front view of the tester with labels for components
Front View: Labeled components including battery stands, expansion test blocks, cooling fans, display screen, and control buttons.
  • CH1-8: 8-channel 18650 battery test stand
  • P1-8: 8-channel expansion test 2P terminal block
  • F1, F2: 50x50 cooling fans
  • D1: 2.4-inch color display screen
  • B1: Run/Stop button (R/S)
  • B2: Menu keys (M)
  • B3: Channel button (CHN)
  • B4: Adjustment button (S)

Indicator Light Status:

Indicator light status description
Indicator light status: Out (Stop), Flashing (Running), Changliang (Done).

Real-time Parameters Display:

Real-time parameters display on the screen
Real-time parameters: 1. Real-time battery voltage, 2. Real-time current, 3. Working mode, 4. Work step status, 5. Program running time, 6. Temperature.

Voltage and Current Curve Display:

Voltage and current curve display
Voltage and current curve display: 1. Voltage coordinate, 2. Current coordinate, 3. Time coordinate, 4. Voltage curve, 5. Current curve.

Work Step Parameters:

Work step parameters display
Work step parameters: 1. Channel indication, 2. First charge (charging voltage, current, standing time, capacity), 3. First discharge (discharge stop voltage, current, standing time, capacity), 4. Recharging (recharging voltage, current, standing time, capacity).

Setting Method

The device allows for detailed parameter adjustments through its menu interface.

Entering the Menu:

  • From the overview or detail interface, long press the "M" (Menu) button for 3 seconds to enter the menu interface.
  • If no action is taken for 10 seconds in the menu, or if the "M" button is long-pressed for 3 seconds, the settings will be saved, and the device will return to the overview interface.
Menu interface for settings
Setup Menu: Displays various adjustable parameters.

Navigating and Adjusting Settings:

  • Switching Menu Options: Click the "M" (Menu) button to cycle through different menu options (e.g., Mode, Vol-CHG1, Cur-CHG, etc.).
  • Adjusting Values: Use the "S" (Adjustment) button to change the value of the currently selected parameter.
  • Switching Language: While in the menu interface, long press the "R/S" (Run/Stop) button for 3 seconds to switch between Chinese and English.
  • Channel Synchronization: The "Sync CHN Setting" option allows you to apply settings to all 8 channels simultaneously (YES) or set parameters for each channel individually (NO). Adjust this setting using the "S" button.
  • Switching Channels: Click the "CHN" (Channel) button to switch between different channels for individual parameter settings.

Video Guide: Menu Navigation and Settings

Play video
Watch video online

This video demonstrates how to enter the menu, switch between languages, adjust parameters like charge/discharge current and voltage, and start/stop tests.

Steps to Use

  1. Connect Power: Ensure a stable DC 12-19V power supply is connected.
  2. Install Batteries: Insert flat-head 18650 batteries into the desired channels, observing correct polarity.
  3. Set Parameters: Enter the menu (long press 'M' for 3s) and configure the desired operating mode, charging/discharging voltages, currents, and standstill times for each channel or all channels if synchronization is enabled.
  4. Start Test:
    • To start a single channel: Select the channel using the 'CHN' button, then click the 'R/S' button.
    • To start all channels simultaneously: Long press the 'R/S' button for 3 seconds.
  5. Monitor Progress: Observe the real-time parameters and curves on the display. The indicator lights will show the status (flashing for running, solid for done).
  6. Stop Test:
    • To stop a single channel: Select the channel using the 'CHN' button, then click the 'R/S' button.
    • To stop all channels: You must stop each channel individually.
  7. Check Results: Review the capacity measurement and other data once the test is complete.
  8. Disconnect Battery: Safely remove the batteries after testing.

User Tips

  • Always double-check battery compatibility (flat-head 18650 only) and polarity before insertion to prevent damage.
  • For optimal performance and to prevent overheating, ensure adequate ventilation around the device, especially during prolonged charging/discharging cycles. The built-in fans will activate automatically when the temperature reaches 40°C.
  • If you need to test lithium iron phosphate batteries, remember to use only the discharge mode. Charging, automatic, and active modes are strictly prohibited for LiFePO4.

Troubleshooting

  • Device not powering on: Ensure the power supply is correctly connected and provides the required DC 12-19V. Check the power adapter for functionality.
  • Batteries not detected/testing not starting: Verify that batteries are inserted with correct polarity and are flat-head 18650 type. Check if the battery holder springs are making good contact.
  • Inaccurate readings: Ensure the batteries are clean and free from corrosion. For internal resistance measurement, the DC two-wire method is used for sorting and analogy, not precise measurement.
  • Overheating: The device has active heat dissipation. Ensure the fans are not obstructed and the ambient temperature is reasonable. If overheating persists, reduce the load or stop the test.
  • Menu unresponsive: If the menu becomes unresponsive, try exiting by long-pressing the 'M' button. If issues persist, disconnect and reconnect the power supply.

Maintenance

  • Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Store the tester in a dry environment, away from direct sunlight and extreme temperatures.
  • Regularly inspect the battery holders for any signs of wear or damage.
  • Ensure the cooling fans are clear of obstructions to maintain efficient heat dissipation.

Warranty and Support

For any issues or questions not covered in this manual, please contact the seller or manufacturer for support. Keep your purchase receipt for warranty claims.

This product is certified with CE, indicating compliance with health, safety, and environmental protection standards for products sold within the European Economic Area.

A user manual in PDF format is available for download: View User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.