This manual provides detailed instructions for the installation, operation, and maintenance of the Votol EM50-4 FOC Sine Wave BLDC PMSM Motor Controller. The EM50-4 controller is designed for electric scooters, hub wheel motors, and QS90 mid-drive motors, supporting power ranges from 1000W to 1500W and battery voltages of 48V to 60V.

The Votol controller is designed for seamless integration with QS motors. For other motor brands, parameter adjustments may be necessary. The controller features a Hall Plug, Reverse function, Low Brake (0V), Throttle (0-5V), High Brake (12V), Ignition, One-LIN/Hall Speed Sensor, Program Port, Three Speed modes, Sport Mode, Parking, Anti-Theft, Regen Charge, and Flux Weaken Current.

Important: This manual is intended for specialists. Non-specialist use is forbidden. Please read this manual carefully before starting any operation to ensure maximum utility and prevent damage to the controller.

Package Contents

The package includes the following items:

  • 1 pc x EM50-4 Controller with function harness
  • 1 pc x USB Cable
Votol EM50-4 Controller with function harness and USB cable
Image: Votol EM50-4 Controller, function harness, and USB cable.

Specifications

FeatureSpecification
ModelEM50-4 ECU Sine Wave Controller
Available Battery Voltage48V-72V
Rated DC Current40A
Boost DC Current80A
Peak Phase Current170A
Max. Power5760W
Mosfets Detail12 FET
Matched Motor Rated Power800W-2000W
Max. Efficiency92%
Degree of WaterproofIP65
Flux Weakening Ratio150%
CertificationCE, CCC
Working CommunicationHall Sensor
Net Weight800g
Size181mm * 94mm * 50mm
ProgrammableSupported via PC
Speed SignalOne-lin (YXT) & Hall speed signal
Controller drawing with dimensions
Diagram: Controller dimensions (181mm x 94mm x 50mm).

Setup

1. USB Driver Installation

  1. Download the "USB-to-serial-win 10-20150814" file and decompress it.
  2. Choose the suitable driver for your computer (Win7/Win10 are supported; iOS and XP systems are not). For non-Chinese PC systems, ensure no Chinese characters appear in the driver filename.
  3. After installation, connect the USB cable to the controller and computer. If connection issues occur, right-click "My Computer" on the desktop, then select "Device Manager" > "Ports (COM & LPT)". Choose the COM port with an exclamation mark, right-click, and select to update the software. Browse your computer to find the driver software.
  4. Select "Prolific USB-to-Serial Comm Port Version: 3.3.2.102 [2008/9/24]", click Next, complete the installation, and close the software.

2. Software Installation

For versions from 2018.7 onwards, steps 1 and 2 below are not required; simply install the USB driver and open the software directly.

  1. Copy the TeeChart5.ocx file to the C drive root directory.
  2. Click the setup "Register File Finish Installation" (allow installation if the software shows an intercept interface). After installation, run the EM_V3 program download software.

3. Controller Connection

  1. Power on the controller, ensuring the ignition is closed.
  2. In the software, click "Creat File".
  3. Click the research button, then select the correct series port from the device COM list (usually the last one).
  4. Click "Open Series Port"; the device status should show "Connected".
  5. Turn on the ignition, then click "Connect" controller (it is recommended to click more than twice).
  6. The voltage parameter can be freely chosen if supported by the controller's hardware.

4. Bluetooth Serial Port Connection (Optional)

If using a Bluetooth serial port connection module from VOLT company:

  1. Connect the Bluetooth module and power it on.
  2. Select the Bluetooth module from your device's Bluetooth list and pair with it.
  3. Input the password "1234" to connect.

5. Port & Wiring Definition

Refer to the diagrams below for detailed port and wiring definitions. Proper connection is crucial for safe and correct operation.

Detailed wiring diagram for controller ports
Diagram: Detailed wiring for Hall Sensor (red 5V, black negative, yellow Hall A, green Hall B, blue Hall C), Ignition (grey-purple), Program Port (black GND, pink positive 5V, orange TXD, blue RXD), Throttle/High Brake/Speed Signal (purple high brake 12V, white one-lin/hall speed signal, black throttle negative, green throttle signal, pink throttle 5V), Alarm Power (black GND, red anti theft power supply), Three Speed/Sport/Parking (brown-white parking, green-white low speed, yellow-white sport, black GND, black-white high speed), Anti-theft Motor Lock (orange anti theft key ignition, blue anti-theft signal, yellow wheel signal), Low Brake/Reverse (grey-white reverse, grey-black low brake).
Detailed pinout diagrams for 2*8, 2*4, and 2*3 interfaces
Diagram: Pinout definitions for the 2*8 interface (Ignition, UART-TX, UART-RX, Reverse, Low Speed, GND, Sport, Low Brake, Throttle 5V, GND, Throttle Signal, Speed, One Click Repair, Parking, One-Line, High Brake), 2*4 interface (Anti-Theft Power Supply, Anti-Theft Key Ignition, Wheel Signal, Anti-Theft Signal), and 2*3 interface (Hall+, Hall-, Hall Signal A, Hall Signal B, Hall Signal C).

Operating Instructions

The VOTOL-EM-V3 Software Debugging interface allows for comprehensive configuration of the controller. Below are key settings and their adjustments.

Screenshots of the VOTOL-EM-V3 Software Debugging interface
Image: Screenshots of the VOTOL-EM-V3 Software Debugging interface, showing various settings and parameters for configuration.

1. Battery Voltage Adjustment

The voltage parameter can be freely chosen based on hardware support. Select the appropriate battery voltage (e.g., 48V, 60V, 72V, 84V, 96V, 108V) from the dropdown menu. Note: Adjusting the voltage parameter without corresponding hardware support will damage the controller.

2. Controller Under-voltage and Soft Under-voltage Adjustment

Fill in the required under-pressure protection parameters:

  • Under voltage value: The threshold at which the controller enters hardware under-voltage protection. Set based on the battery's under-voltage value.
  • Soft under-voltage: Generally set to under-voltage + 3V.
  • Undervoltage variation: The range for the under-voltage to recover. If set to 63V for overvoltage and 1V for undervoltage variation, the controller will recover at 64V. It is not recommended to change under-voltage settings as it can damage the battery and reduce its lifespan due to excessive discharge.

3. Controller Battery Current and Phase Current Limited Adjustment

Adjust the Busbar current and Phase current limits. Refer to the table below for recommended ranges:

ModelVoltageCurrent Limit
EM-30S48-72V≤35A
84V≤30A
EM-5048-72V≤50A
84V≤55A
96V≤45A
108V≤45A
EM-10048-60V≤120A
72V≤120A
96V≤120A
EM-15048-60V≤150A
72V≤180A
96V≤120A

Warning: Do not set values outside the specified range, as this will damage the controller.

The phase current limited value will limit the motor torque output. The setting range (the biggest value full power output) is not suggested to be adjusted.

4. Throttle Voltage Adjustment

  • Low protection value: Indicates a throttle error.
  • Starting voltage: The voltage at which the motor begins to run.
  • End voltage: The voltage at which the controller considers full throttle is reached. It is recommended to set this value 0.2V lower than the actual torque voltage.
  • High protection value: If the throttle voltage exceeds this value, a torque fault will be displayed.

5. Start Setting Adjustment (for Tricycle Gear Box Only)

  • Starting torque: Used for gear combination.
  • Combined torque: A force of lifting after gear clearance is combined.
  • Upward slope: Upward slope of motor torque.
  • Downward slope: Downward slope of motor torque.

6. Controller and Motor Temperature Protection Function Adjustment

  • Start: Activates the temperature protection function, limiting motor torque.
  • Over temperature: Cuts off the output of motor torque.
  • Recover: When the motor temperature drops below the protection value, you can re-twist the throttle to restore motor motivation.
  • Maximum: The maximum motor temperature is 150°C.

7. Parameters Setting for Sports Mode (S Gear)

  • Current-limiting value for S gear: When the controller enters S gear, the battery current increases, providing more power for climbing.
  • Flux weakening value for S gear: When the controller enters S gear, the motor will be in a flux weakening condition, increasing speed. The setting value range is determined by motor condition.
  • Warning: Do not exceed the specified range for flux weakening, as this can cause motor demagnetization and damage.

    For dual voltage mode, the left side option refers to low voltage, and the right side option refers to high voltage. For single voltage controllers, set both left and right values to be the same.

  • Automatic logout enablers: Configure logout time (e.g., 30s after entering S gear sport mode) and recovery time.
  • Three gear setting: The three-gear ratio ranges from 0-100%. Adjust middle speed and high speed flux weakening ranges.
  • Soft start enable: Open the controller for soft start or close for hard start. Soft start grade ranges from 1 to 16, where a lower value indicates a softer start.

8. Downhill Electric Brake Assist (HDC/HHC)

Enable this function to slow down on steep slopes. Set the minimum speed for electric brake activation. If the speed is below this minimum, the function will be invalid. A value of 400 corresponds to approximately 15km/h (may vary based on motor features).

9. Speed Limit Setting

Enable the speed limit function and adjust the controller speed limit from 0 to 100 percent.

10. Motor Setting

  • Motor pole pairs: Correctly fill in the motor pole pair for accurate motor speed (RPM) acquisition.
  • Motor type (middle drive motor): Correctly fill in the motor's magnet type for motor matching. Note: Wheel Hub motors are surface mount.
  • Hall phase shift angle: Adjust the controller and motor phase within the range of -180° to 180°.

11. Choice of Speedometer Output

The controller supports two types of speedometer data output: Single-line speedometer and Hall speedometer. The choice depends on the vehicle's speedometer type. The first-line fixed agreement is based on a new thinking standard agreement.

12. Moving Assist and Cruising Function

  • Move assist function: Valid after checking the option. The speed of the transfer assist is selected as a percentage of the motor base speed (default 10%). A moving assist torque value of 320 corresponds to 9-10N.m (varies by motor characteristics).
  • Cruise function: Valid after checking the option. Maintain a certain throttle angle for more than 8 seconds to enter cruise control mode. Any operation (braking, turning the handle) will exit cruise mode.

13. Dual Voltage Adaptive Function

Enable the dual voltage adaptive function. The controller can automatically switch between dual voltage modes based on the following thresholds:

ModeVolt for switching to low volt modeVolt for switching to high volt mode
48~60V<49V>63.5V
60~72V<61V>77V
72~84V<72V>93.5V

14. Reversing, EBS Setting, Low Brake Selection, Starting Safety Switch Function

  • Reversing speed limit: Adjust from 0-100%. Note: Do not exceed 30% to avoid accidents.
  • EBS ratio: Adjust from 0-100% for electronic brake force adjustment.
  • Low brake enable: Validates the low brake function. When used, the original single-branch power-down function becomes a low-level brake.
  • Safety switch function: When enabled, the safety switch must be pressed before starting the vehicle.

Controller Status Display

The software provides a real-time display of the controller's working status, including RPM, Voltage, Current, Fault Code, and other fault indicators (Hall Fault, Overvoltage, Overcurrent, etc.). This allows for easy observation of the controller's performance.

Troubleshooting

Remote Operation and Software Updates

Remote operation, software updates, current calibration, and debugging should only be performed under the guidance of a company engineer.

To update the software: Click "Opening File" > choose the ".bin" file > click "Download". A 100% success message indicates the file import was successful.

Controller Communication Issues

If the controller cannot communicate with the computer, you may need to "brush the bottom program". Follow these steps:

  1. Ensure the ignition is closed.
  2. Open the debugging software (upper computer) and open the serial port. Do not click "Connect" yet.
  3. Turn on the ignition, then open the "CAN.Bin" file.
  4. The controller should then connect normally.

User Tips

  • The Votol controller is designed to match well with QS motors. If using other motor brands, be prepared to adjust parameters manually for optimal performance.
  • Most functional interfaces require modification and are not plug-and-play. Carefully check the original vehicle's function lines and speedometer communication signals before making any modifications.
  • If you lack experience in electric kit assembly, exercise caution before purchasing or attempting installation.

Warranty & Support

We offer a 1-year warranty for motors and controllers. Please note that the buyer is responsible for the return shipping cost for any repairs or replacements under warranty. The warranty does not cover man-made damage.

For further assistance or if you encounter any problems, please contact our support team. We are committed to helping you resolve any issues.

A user manual in PDF format is available for download: User manual (PDF)

Frequently Asked Questions (FAQ)

Q: About the functions and interfaces of the controller
A: Most controllers we sell are universal versions, not customized for a specific brand. Therefore, after installation, some auxiliary functions of the original vehicle may not work normally (such as speedometer display). Most functional interfaces need to be modified, not plug and play. Before refitting, please carefully check the function line on the original vehicle and the communication signal of the speedometer.
Q: How about the warranty?
A: We offer a 1-year warranty for motors and controllers, but the buyer has to pay the return shipping cost for repairing or replacing a new one. If you have any problems, please feel free to contact us, and we will try our best to help you. If you don't have any experience on electric kits assembly, please make a prudent choice to buy it or not! There is no warranty for man-made damage.

Product Video

Video: A 15-second rotating view of the Votol EM50-4 controller, showcasing its design and various connection points.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.