Votol EM100+Display+Throttle

Contents

Votol EM100 Controller Kit Instruction Manual

Model: EM100+Display+Throttle

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Votol EM100 Controller Kit. The kit includes the EM100S sine wave controller, DKD display, and T08 throttle, designed for electric motors ranging from 2000W to 3000W, compatible with 48V, 60V, and 72V systems. This controller is specifically optimized for QS motors, but parameters can be adjusted for other brands.

NOTE: The DKD display and T08 throttle are not plug-and-play with the controller; manual wiring is required.

Votol EM100 Controller kit with DKD display and T08 throttle
Figure 1: Votol EM100 Controller Kit components including the controller, DKD display, and T08 throttle.

2. Package Contents

The Votol EM100 Controller Kit includes the following items:

  • 1 pc x EM-100 Controller with function harness
  • 1 pc x USB Cable
  • 1 pc x DKD Display with bracket
  • 1 set x T08 Combination Switch (Throttle)

3. Specifications

3.1. EM-100 ECU Sine Wave Controller

  • Model: EM-100 ECU sine wave controller
  • Available Battery Voltage: 48V-72V
  • Rated DC current: 60A
  • Boost DC current: 120A
  • Peak Phase current: 300A
  • Max. Power: 7200W
  • Mosfets Detail: 18 FET
  • Matched Motor Rated Power: 2KW-3KW
  • Max. Efficiency: 93%
  • Degree of Waterproof: IP67
  • Flux Weaking Ratio: 150%
  • Certification: CE, CCC
  • Working Communication: Hall Sensor
  • Net weight: 1650g
  • Size: 218mm * 124mm * 62mm
  • Support Programmable by PC
Votol EM100 Controller dimensions
Figure 2: Dimensions of the Votol EM100 Controller (in mm).

3.2. DKD Display

  • Displays data: Speed (KMH/MPH), DC current, Battery Level, Trip Distance, Fault Display, Head Light, Turning Light, Gear Display.
DKD Display front view
Figure 3: Front view of the DKD Display showing various indicators.
DKD Speedometer dimensions and wire definition
Figure 4: DKD Speedometer dimensions (in mm) and wire definitions.

DKD Speedometer Wire Definition (5557-2*10)

  • Green/Black: CAN+
  • Yellow/Red: CAN+
  • Blue: Head Light
  • Light Blue: Turn Right
  • Orange: Turn Left
  • Purple/White: Battery Positive (48-96V)
  • Yellow/White: One-Lin (YXT) & Hall Speed Signal
  • Black: Negative

3.3. T08 Throttle

  • Functions: Three Speed, P Gear, Reverse, One Click Repair, Left Turn Signal, Right Turn Signal, Headlight, Horn, High Beam, Low Beam.
T08 Throttle with combination switches
Figure 5: T08 Throttle with integrated combination switches.

3.4. Package Dimensions and Weight

  • Length: 31 cm
  • Width: 31 cm
  • Height: 11 cm
  • Weight: 3.3 kg

4. Setup Guide

4.1. Wiring Diagrams

Carefully follow the wiring diagrams for proper connection of the controller, display, and throttle. Incorrect wiring can damage components.

Votol EM100 Controller wiring diagram
Figure 6: Votol EM100 Controller wiring diagram with labeled connectors.

Controller Connector Definitions:

Connector Wire Color Function
Hall SensorRedHall 5V
BlackHall Negative
YellowHall A
GreenHall B
BlueHall C
IgnitionGrey-PurpleIgnition
Throttle, High Brake, Speed SignalPurpleHigh Brake 12V
WhiteOne-Lin/Hall Speed Signal
BlackThrottle Negative
GreenThrottle Signal
PinkThrottle 5V
Three Speed, Sport, ParkingBrown-WhiteParking
Green-WhiteLow Speed
BlackGND (Black)
Black-WhiteHigh Speed
Low Brake, ReverseGrey-WhiteReverse
Grey-BlackLow Brake
One Click RepairBrownOne Click Repair
Program PortPinkPositive 5V
OrangeTXD
BlueRXD
BlackGND
Alarm PowerRedAnti-theft Power Supply
BlackGND
Anti-theft Motor LockOrangeAnti-theft Ignition
BlueAnti-theft Signal
YellowWheel Signal
T08 Throttle wiring diagram
Figure 7: T08 Throttle wiring diagram for left and right sides.

Left Throttle Wiring:

  • Steering Switch: Grey (input), Orange (turn left), Light-Blue (turn right)
  • Flash: Blue (high beam input), White (low beam input)
  • P Gear: Red (input), Purple (output)
  • Horn: Light-Green (horn input), Black (input)

Right Throttle Wiring:

  • Three Speed: Blue (low gear), Orange (high gear), Gray (input)
  • Light: Green (input), Brown (fog light), Blue-White (headlight)
  • Throttle Signal: Green (throttle signal), Black (negative), Red (positive)
  • Repair: Red-Yellow
  • Reverse: Purple
  • Negative: Black

4.2. USB Driver Installation (Windows 7/10)

This section details the installation of the USB driver required for PC communication with the controller. For new versions (2018.7 onwards), only the USB driver installation is needed; the software can then be opened directly.

  1. Download the "USB-to-serial-win 10-20150814" file and decompress it.
  2. Choose the suitable driver for your computer (Windows 7/10 are supported; iOS and XP are not). For non-Chinese PC systems, ensure no Chinese characters appear in the file name.
  3. Proceed with the driver installation (e.g., PL-2303 Driver Installer).
  4. After installation, connect the USB cable to the controller and computer. If connection issues arise:
    • Right-click "My Computer" on the desktop, then select "Device Manager".
    • Navigate to "Ports (COM & LPT)", identify the COM port with an exclamation mark (!).
    • Right-click the problematic COM port and choose to update the software.
    • Select "Browse Computer to find out the drive software".
    • Choose "Select from computer Drive program list".
    • Select "Prolific USB-to-Serial Comm Port Version: 3.3.2.102 [2008/9/24]" (or the latest compatible version).
    • Click Next to complete the installation.
  5. For software installation, copy the TeeChart5.ocx file to the C drive root directory.
  6. Run the setup file to register the components. After successful installation, launch the EM_V3 program.

4.3. Controller Connection to Software

  1. Ensure the controller is powered on and the ignition is closed.
  2. In the software, click "Create File".
  3. Click the research button to find available COM ports. Select the correct serial port (usually the last one listed).
  4. Click "Open Series Port". The device status should show "Connected".
  5. Turn on the ignition, then click "Connect" to the controller (it is recommended to click more than twice for a stable connection).
  6. Bluetooth Serial Port Connection: If using a Bluetooth serial port module (e.g., from VOLT company), connect it and power it on. Pair with the Bluetooth series port from your device list. The default password is "1234".

5. Operation and Parameter Adjustment

The Votol EM-V3 software allows for detailed configuration of the controller's parameters. Always ensure you understand the implications of each setting before making changes.

5.1. Battery Voltage Adjustment

The voltage parameter can be freely chosen within the hardware support limits of the controller. Adjusting the voltage parameter without corresponding hardware support will damage the controller.

Model Voltage Options
EM-30S48-72V, 84V
EM-5048-72V, 84V, 96V, 108V
EM-10048-60V, 72V, 96V
EM-15048-60V, 72V, 96V

Note: If the voltage parameter is adjusted without hardware support, the controller will be damaged.

5.2. Controller Under-Voltage and Soft Under-Voltage Adjustment

Fill in the required under-pressure protection parameters and software under-pressure parameters:

  • Under Voltage Value: The threshold for hardware under-voltage protection. Setting range is based on the battery's under-voltage value.
  • Soft Under-Voltage: Generally, set to under-voltage + 3V.
  • Under-Voltage Variation: This refers to the range of under-voltage recovery. For example, if over-voltage is 63V and under-voltage variation is 1V, the controller will recover at 64V. It is not adjustable.

P.s. It is not recommended to change the under-voltage setting as it can easily damage the battery and lead to reduced battery life due to excessive discharge.

5.3. Controller Battery Current and Phase Current Limited Adjustment

Adjust the battery current and phase current limits. Do not set values outside the recommended range to prevent damage to the controller.

Model Voltage Battery Current Limit
EM-30S48-72V≤35A
84V≤30A
EM-5048-72V≤50A
84V≤55A
96V≤45A
108V≤45A
EM-10048-60V≤100A
72V≤100A
96V≤100A
EM-15048-60V≤150A
72V≤180A
96V≤120A

P.s. Please don't fill in the value out of range, it will damage the controller.

Phase Current Limited Value: If the controller limits phase current output, it will limit the motor torque output. The setting range is the biggest value for full power output; adjustment is not suggested.

5.4. Throttle Voltage Adjustment

  • Low Protection Value: Indicates a throttle error.
  • Starting Voltage: The motor begins running when this value is reached.
  • End Voltage: The controller considers full voltage reached when this value is met. It is recommended to set this value 0.2V lower than the actual torque voltage.
  • High Protection Value: If the throttle voltage exceeds this value, a torque fault will be displayed.

5.5. Start Setting Adjustment (for Tricycle Gear Box Only)

  • Starting Torque: Used for gear combination.
  • Combined Torque: A force for lifting after gear clearance is combined.
  • Upward Slope: Upward slope of motor torque.
  • Downward Slope: Downward slope of motor torque.

5.6. Controller and Motor Temperature Protection Function Adjustment

  • Start: The point at which temperature protection activates, limiting motor torque.
  • Over Temperature: Motor torque output is cut off.
  • Recover: When the motor temperature drops below the protection value, twisting the throttle will restore motor motivation.
  • Maximum: The motor's maximum operating temperature is 150°C.

5.7. Parameters Setting for Sports Mode (S Gear)

When the controller enters S gear, the battery current increases for more powerful climbing. The setting value should not be out of range to avoid damaging the controller.

Model Voltage Current Limiting (S Gear)
EM-30S48-72V≤40A
84V≤35A
EM-5048-72V≤55A
84V≤55A
96V≤45A
108V≤45A
EM-10048-60V≤120A
72V≤120A
96V≤120A
EM-15048-60V≤200A
72V≤220A
96V≤130A

Please noted: The setting value shouldn't be out of range, otherwise, it will damage the controller.

Flux Weakening Value for S Gear:

When the controller enters S gear, the motor will be in a flux-weakened condition, increasing speed. The setting value range is determined by motor condition. Exceeding the range can cause motor demagnetization and damage.

Motor Type Flux Weakening Value
Wheel hub motor, magnet high lower than 35mm≤1500
Wheel hub motor, magnet high lower than 50mm≤2300
Mid drive motor, surface attached magnetic steel≤2300
Mid drive motor, V magnet steel≤3000

Please noted: The setting value shouldn't be out of range, otherwise, it will cause the motor demagnetizing, then damage the motor.

Automatic Logout Enablers:

  • Logout Time: e.g., 30s after entering S gear sport mode (optional).
  • Recovery Time: Auto-exit S gear, recover from S gear time. Invalid if S gear button is pressed during recovery time.

5.8. Downhill Electric Brake Assist (HDC/HHC)

This function helps slow down on steep slopes. Enable by selecting "HDC Enable" and setting a minimum speed. If the vehicle speed falls below this minimum, the function becomes invalid. A value of 400 corresponds to approximately 15km/h (may vary based on motor features).

5.9. Speed Limit Setting

The controller's speed limit can be adjusted from 0 to 100 percent. Enable by selecting "Speed Limited Enable" and setting the desired speed.

5.10. Three Gear Setting

  • Three Gear Ratio: Range from 0-100%.
  • Middle Speed and High Speed Flux Weakening Adjustment: The left side option refers to low voltage, and the right side option refers to high voltage. For single voltage controllers, set both values to be the same.
  • Three Speed Mode: Two modes are available: by button and by switch.
  • Three Gear Default Gear: Can be enabled for point switch.
  • Change Controller Default Gear: Configures the default gear when the controller powers on.
  • Soft Start Enable: Opens the controller in soft start mode. Closing it enables hard start. Soft start grade ranges from 1-16; a lower value indicates a softer start.

5.11. Motor Setting

  • Motor Pole Pairs: Correctly fill in the motor pole pair for accurate motor speed (RPM) acquisition.
  • Motor Type (Middle Drive Motor): Correctly fill in the type of motor's magnet for motor matching. Note: Wheel Hub motors are surface mount type.
  • Hall Phase Shift Angle: Adjust the controller and motor phase within the range of -180 to 180 degrees.

5.12. Speedometer Output

The controller offers two types of speedometer data output: Single-line speedometer and Hall speedometer. The choice depends on the vehicle's speedometer. The single-line fixed agreement follows a new thinking standard agreement.

5.13. Moving Assist and Cruising Function

  • Move Assist Function: Valid after checking. The speed of the transfer assist is selected as a percentage of the motor base speed (default 10%). Moving assist torque value 320 corresponds to 9-10N.m (varies by motor characteristics).
  • Cruise Function: Valid after checking. To activate, maintain a certain throttle angle for more than 8 seconds. Any operation (braking, turning the handle) will exit cruise mode.

5.14. Dual Voltage Adaptive Function

The controller supports automatic switching between dual voltage modes.

Mode Volt for switching to low volt mode Volt for switching to high volt mode
48~60V<49V>63.5V
60~72V<61V>77V
72~84V<72V>93.5V

5.15. Reversing, EBS Setting, Low Brake Selection, Starting Safety Switch Function

  • Reversing Speed Limit (%): Adjust from 0-100. Do not exceed 30% to avoid accidents.
  • EBS Ratio (%): Adjust electronic brake force from 0-100.
  • Low Brake Enable: Validates the low brake function. When used, the original single-branch power-down function becomes a low-level brake.
  • Safety Switch Function: Validates the safety switch. When using, the safety switch must be pressed before starting the vehicle.

5.16. Controller Status Display

The software provides a real-time display of the controller's working status, including RPM, Voltage, Current, Fault Code, Hall Fault, Brake status, Overheating, and other parameters.

5.17. Port Setting Interface

If you are using a Hall Type Display, select "IO" and "F", then choose "13: Hall" in the port settings.

6. Maintenance

Regularly inspect all wiring connections for tightness and signs of wear or damage. Ensure the controller and motor are free from excessive dirt and moisture. Periodically check for any error codes displayed on the DKD display and refer to the troubleshooting section for resolution.

7. Troubleshooting

7.1. Software Communication Issues (Remote Operation)

If the controller fails to communicate with the software, you may need to re-flash the base program. This procedure should only be performed under the guidance of a qualified engineer.

  1. Ensure the ignition is closed.
  2. Open the debugging software (upper computer).
  3. Open the serial port (no need to click "Connect" yet).
  4. Open the "CAN. Bin" file.
  5. Proceed with the download. Once complete and showing 100%, the file import is successful.
  6. The controller should then connect normally.

7.2. General Troubleshooting Tips

  • Controller Functions: Most functional interfaces require modification and are not plug-and-play.
  • Parameter Adjustment: Always ensure that any voltage or current parameters adjusted in the software are within the hardware's supported range. Setting values out of range will damage the controller or demagnetize the motor.
  • Wiring: Before making any modifications, carefully check the function lines on the original vehicle and the communication signal of the speedometer.
  • Reversing Speed Limit: Do not exceed 30% for the reversing speed limit to prevent accidents.

8. User Tips

  • The Votol controller is known to match well with QS motors. For other motor brands, be prepared to adjust parameters manually.
  • Due to the universal nature of these controllers, some auxiliary functions of your original vehicle (like speedometer display) might not work normally after installation without further modification.
  • Always double-check your vehicle's original wiring and speedometer communication signals before attempting any modifications.

9. Warranty and Support

We offer a 1-year warranty for motors and controllers. Please note that the buyer is responsible for return shipping costs for repairs or replacements.

If you encounter any issues, please contact us for assistance. We will do our best to help you resolve them.

Important: If you lack experience in assembling electric kits, please consider carefully before purchasing. There is no warranty for man-made damage.

A detailed PDF manual, "VOTOL EM Controller Program Manual V2.2 (2019-11-21)", is available for download. This manual is intended for professional and technical personnel only. Non-specialist use is forbidden. You can find this document referenced at this link.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.