1. Product Overview

The K24 Electronic Turbine Flow Meter is a compact digital flow measurement instrument designed for monitoring the flow rate and cumulative volume of low-viscosity liquids. It is suitable for diesel, gasoline, kerosene, methanol, and water applications. The device uses a turbine sensing mechanism combined with an electronic display to provide real-time flow rate and totalized volume readings.

This product is intended for industrial, commercial, and agricultural liquid transfer systems where accurate and repeatable flow measurement is required.

K24 Digital Turbine Flow Meter main unit

Figure 1: K24 Digital Turbine Flow Meter

2. Specifications

The K24 Digital Turbine Flow Meter offers precise measurement capabilities for various liquid types. Key specifications are detailed below:

ParameterDetails
BrandCERTEON
Flow Meter TypeElectronic turbine flowmeter
MaterialPPS Plastic, 304 Stainless Steel
Diameter / Thread SizeG1/2, G3/4, G1
Connection TypeExternal / Internal Thread / Insertion
Flow Range0.3-20 L/min, 5-40 L/min, 10-100 L/min (depending on selected model)
Measurement Accuracy±1%
Repeatability±1%
Power SupplyBattery powered (Internal battery supply, exact model to be confirmed)
DisplayLCD digital display, non-waterproof
Max. Working Temperature≤60°C
Max. Working Pressure≤0.6 MPa
Application MediaDiesel, gasoline, kerosene, methanol, water
Package ContentsFlow meter unit (Standard configuration)
K24 Flow Meter with key specifications highlighted

Figure 2: K24 Flow Meter with key specifications

Multiple models of high-precision turbine flowmeters

Figure 3: Multiple models of high-precision turbine flowmeters

3. Setup and Installation

Proper installation is crucial for accurate and reliable operation of your K24 Flow Meter.

  1. Preparation:
    • Ensure that the selected thread size and connection type (G1/2, G3/4, G1; External/Internal Thread/Insertion) match your pipeline system.
    • Confirm that the flow direction corresponds to the arrow marking on the meter body.
    • Install appropriate sealing elements (e.g., PTFE tape, gaskets) to prevent leakage at all connections.
    • The display unit is non-waterproof; install it in a dry and protected environment, away from direct moisture or spray.
  2. Installation:
    • Install the flow meter securely into the pipeline using the selected connection type.
    • Open the upstream valve slowly to allow liquid to fill the meter and remove any trapped air from the system.
    • Avoid sudden pressure surges during startup.
    • Ensure the operating temperature and pressure remain within the specified limits (≤60°C and ≤0.6 MPa).
Various K24 flow meter models with different connection types and sizes

Figure 4: Multiple sizes and models available for various connection types

PPS G1 External Thread Type flow meter with dimensions

Figure 5: PPS G1 External Thread Type with dimensions (101*71*54mm)

1-inch plastic body with external thread dimensions and specifications

Figure 6: 1-inch plastic body with external thread (Length: 100mm, Width: 75mm, Height: 55mm)

1 inch plastic body with internal thread dimensions and specifications

Figure 7: 1-inch plastic body with internal thread (Length: 100mm, Width: 75mm, Height: 55mm)

Intubated plastic body 1/2 inch dimensions and specifications

Figure 8: Intubated plastic body 1/2 inch (Length: 105mm, Width: 75mm, Height: 70mm)

4. Operation

The K24 Flow Meter features a clear LCD display for easy data reading and simple controls.

  1. Data Reading:
    • The LCD screen displays instantaneous flow rate (e.g., L/min) and cumulative volume (e.g., Liters).
    • The display also shows single accumulation, total accumulation, and allows access to settings/review.
  2. Controls:
    • Use the RESET button to clear the single cumulative value if required.
    • The CAL button (or SET button) may be used for calibration adjustment according to system requirements. Calibration procedures should only be performed by qualified personnel.
    • The MENU button allows access to settings and review functions.
K24 Flow Meter display with labeled functions

Figure 9: K24 Flow Meter display with labeled functions (Single accumulation, Real-time flow rate, Settings/Review, Single reset, Total accumulation, Five measurement units)

K24 Flow Meter showing easy operation with current flow display, unit, reset, and set buttons

Figure 10: Easy to read and operate interface

Video 1: Overview of CHIKONG Automation's manufacturing and product applications.

5. Maintenance

To ensure the longevity and accuracy of your K24 Flow Meter, follow these maintenance guidelines:

  • Storage: Store the product in a dry, well-ventilated environment away from direct sunlight and corrosive substances.
  • Cleaning: Clean the exterior with a soft, dry cloth. Do not use aggressive solvents, as they may damage the display or housing.
  • Long-term Storage: If the meter is not used for an extended period, remove the battery to prevent potential leakage and damage to internal components.
  • Inspection: Periodically inspect all threaded connections and seals for signs of wear, damage, or leakage. Replace worn components as necessary.
  • Calibration: Calibration should be verified regularly according to your operating frequency and local quality control requirements to maintain measurement accuracy.
PPS engineering plastic turbine for high-temperature and corrosion resistance

Figure 11: PPS engineering plastic turbine, resistant to high temperatures and corrosion

Stainless steel components for enhanced corrosion resistance

Figure 12: Stainless steel components for enhanced corrosion resistance

6. User Tips

  • For stable and accurate volume readings, ensure the operating pressure in your pipeline system remains within the specified limits (up to 0.6 MPa).
  • Always check for proper sealing and connection tightness to prevent leaks, especially when dealing with flammable liquids.

7. Safety Warnings and Precautions

WARNING!

  • This flow meter is intended for use with flammable liquids such as diesel and gasoline. Ensure proper grounding and avoid use in explosive atmospheres unless the full system complies with ATeX requirements.
  • Do not use near open flames, sparks, or high-temperature surfaces.
  • Ensure all electrical components are properly sealed and protected from fuel vapor exposure.
  • Improper installation may result in leakage, fire hazard, or equipment damage.
  • Keep out of reach of children.
  • Proper disposal: Follow WEEE directives for electronic waste.

Precautions:

  • This device is suitable only for low-viscosity, non-corrosive liquids compatible with 304 stainless steel and PPS plastic.
  • Do not exceed the maximum working pressure of 0.6 MPa.
  • Do not exceed the maximum operating temperature of 60°C.
  • The display unit is not waterproof and must be protected from rain, moisture, and direct water spray.
  • Avoid strong vibration, impact, or mechanical stress during operation.
  • Battery replacement must be performed in a dry environment. Use only the specified battery type.
  • Ensure that no air enters the pipeline during measurement, as this may affect accuracy.

8. Compliance Disclaimer

This document is provided for product instruction purposes only. It does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations.