1. Introduction
The NOYAFA NF-604 is an intelligent digital measuring instrument specifically designed for detecting halogen gases. It features a high-sensitivity sensor, a flexible probe, and a clear LCD display, making it suitable for various applications including industrial leak detection, gas pipelines, household appliances, and car repair. This manual provides comprehensive instructions for the safe and effective use of your NF-604 detector.

2. Safety Information
Please read and understand all safety warnings and instructions before operating this device. Failure to do so may result in injury or damage to the product.
- Do not attempt to repair or modify the device yourself. Refer all servicing to qualified personnel.
- Ensure proper battery installation with correct polarity.
- Do not expose the device to extreme temperatures or humidity.
- Keep the device away from strong electromagnetic fields.
- Always operate the device in a well-ventilated area.
- Avoid direct contact with detected gases, as some may be harmful.
3. Product Overview
The NF-604 features an ergonomic design for comfortable use and a flexible probe to reach various detection areas.

3.1 Components
- Color Screen: Displays real-time concentration, temperature, battery level, and settings.
- Button Function Area: Includes OK, Up/Down arrows, BACK, Settings, and Power On/Off buttons.
- Universal Shaping Tube (Flexible Probe): Approximately 250mm in length, allowing access to hard-to-reach areas.
- Probe: The sensing element at the end of the flexible tube.
- Nameplate: Contains product information.
- Buzzer: Provides audio alerts for gas detection and alarms.
- Battery Door: Located on the back for battery installation.
- Motor: Provides vibration feedback for alarms.

4. Setup
4.1 Battery Installation
- Open the battery door located on the back of the device.
- Insert four (4) 1.5V AAA alkaline dry batteries, ensuring correct polarity (+/-).
- Close the battery door securely.

4.2 Initial Power On and Preheating
- Press and hold the power button (red button with power icon) for approximately 2 seconds to turn on the device.
- The device will display a preheating countdown (30 seconds). Wait for the preheating process to complete before proceeding.
- Once preheating is finished, the device will enter the main interface, ready for use.
5. Operating Instructions
5.1 Basic Operation
- Power On/Off: Long press the red power button for ~2 seconds.
- Navigation: Use the 'OK' button to confirm selections, 'Up' and 'Down' arrow buttons to navigate menus, and 'BACK' to return to the previous screen. The 'Settings' button (gear icon) enters the settings menu.

5.2 Gas Detection
The NF-604 is designed to detect halogen gases, including CFCS, HCFCS, and HFCS refrigerants. This includes common types such as R11, R12, R13, R113, R114, R502, R500, R503, R170, R600a, R1270 (CFCS); R22, R32, R123, R124, R141b, R142b, R402A, R402B, R403A, R409 (HCFCS); and R410a, R134a, R404a, R125, R407C, R417A, R507, R23, R1343 (HFCS).

- Ensure the device is powered on and preheating is complete.
- Carefully position the flexible probe near the suspected leak area.
- Observe the color screen for real-time PPM (parts per million) readings.
- The device will provide an audio prompt (buzzer), display font color changes, and vibration indication if a leak is detected. The buzzer will sound slowly for concentrations between the low and high limits, and rapidly for concentrations greater than the high limit.
Applications:
- Industrial Leak Detection: Use the flexible probe to check for leaks in industrial systems and piping.
- Gas Pipeline Inspection: Ideal for inspecting gas pipelines for potential leaks.
- Household Appliances: Detect leaks in refrigerators, air conditioners, and other household appliances.
- Car Repair: Useful for detecting refrigerant leaks in automotive air conditioning systems.




5.3 Temperature Detection
The device can also display ambient temperature. For accurate ambient temperature readings, place the instrument in the environment for more than half an hour before taking a measurement.

5.4 Setting Alarms
- Short press the 'Settings' button (gear icon) to enter the settings interface.
- Navigate to 'AlarmSet' using the Up/Down buttons and press 'OK'.
- Set the desired low and high alarm values using the Up/Down buttons.
- Press 'OK' to confirm and 'BACK' to exit.
5.5 Auto-Off Setting
- Short press the 'Settings' button (gear icon) to enter the settings interface.
- Navigate to 'Auto-Off' using the Up/Down buttons and press 'OK'.
- Select the desired auto-off time (15 minutes, 30 minutes, 60 minutes, or never) using the Up/Down buttons.
- Press 'OK' to confirm and 'BACK' to exit.

6. Maintenance
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the detector in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries.
- Battery Replacement: Replace batteries when the low battery alert appears on the screen or the device powers off due to low voltage.
- Air Filter: The device adopts an air line filter device. Regularly check and clean or replace the filter as needed to maintain optimal performance.

7. Troubleshooting
- Device not turning on: Check battery installation and ensure batteries are not depleted. Replace with fresh alkaline batteries if necessary.
- Inaccurate readings or no detection: Ensure the probe is clean and unobstructed. Allow sufficient preheating time. If issues persist, the sensor might need cleaning or replacement (contact support).
- Short battery life: Ensure you are using high-quality alkaline batteries. Consider using rechargeable AAA batteries if compatible with the device's voltage requirements.
8. Specifications
| Feature | Specification |
|---|---|
| Model | NF-604 |
| Material | ABS |
| Detection Gas | Halogen (CFCS, HCFCS, HFCS) |
| Measuring Range | 0-1000PPM |
| Resolution | 1PPM |
| Preheating Time | 30 seconds |
| Measurement Error (Gas) | ±5%FS |
| Measurement Error (Temperature) | ±1℃/2℉ |
| Response Time (T90) | <30 seconds |
| Sampling Method | Semiconductor sensor sampling |
| Display | Color screen (real-time concentration, battery level, unit, temperature) |
| Alarm Settings | Low alarm function, high alarm function settings |
| Alarm Indication | Sound, display font color change, vibration, working voltage undervoltage |
| Audio Prompt | Slow buzzer (low-high limit), rapid buzzer (above high limit) |
| Auto Power Off | 15min, 30min, 60min, never |
| Working Hours | >6 hours |
| Low Battery Alert | 4.35±0.1V |
| Low Battery Power-Off | 3.5±0.2V |
| Applicable Temperature Range | -10℃~50℃ / 14℉~122℉ |
| Applicable Humidity Range | 10%-99%RH (non-condensing) |
| Power Supply | 4 * 1.5V AAA alkaline dry batteries (Not included) |
| Item Size | 173 * 63 * 31mm / 6.81 * 2.48 * 1.22in |
| Universal Shaping Tube Length | Approx. 250mm |
9. User Tips
- Versatile Detection: While primarily for refrigerants, the NF-604 can also detect other halogenated gases, and some users have reported success with butane and propane. Always verify the gas type if unsure.
- Clear Display: The LCD display is designed for easy readability, providing clear information on gas concentration and settings.
- Battery Choice: For optimal performance and battery life, use high-quality alkaline batteries. If you experience short battery life, consider using reputable brand batteries.
- PDF Manual: A detailed user manual in PDF format is available for further reference. You can access it at User Manual (PDF).
10. Warranty and Support
For warranty information, technical support, or any questions regarding your NOYAFA NF-604 Halogen Refrigerant Leak Detector, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.