1. Introduction
The Diymore ESP32-S3-RS485-CAN is an advanced development board designed for robust industrial communication. It integrates an ESP32-S3 microcontroller, offering powerful AI computing capabilities, Wi-Fi, and Bluetooth 5 (LE) connectivity. This module features electrically isolated RS485 and CAN interfaces, ensuring safer and more reliable data transmission in industrial environments. Its rail-mount design provides easy installation and enhanced protection, making it suitable for a wide range of IoT and industrial control applications.
2. Key Features
- Microcontroller: Based on ESP32-S3, dual-core 240MHz, Xtensa 32-bit LX7 processor with powerful AI computing capabilities.
- Wireless Connectivity: Integrated 2.4GHz Wi-Fi (802.11 b/g/n) and Bluetooth 5 (LE) for stable wireless connections.
- Isolated Interfaces: Electrically isolated RS485 and CAN interfaces for enhanced safety and reliability in industrial communication.
- Indicator Lights: On-board RS485 and CAN indicator lights for easy monitoring of device operational status.
- Design: Rail-mount type shell for easy installation and strong protection.
- Power Supply: Wide voltage range terminal block (7V-36V DC) and USB Type-C (5V) for power supply.
- USB Type-C: For power supply, firmware download, and debugging.
- RTC Clock: On-board RTC clock chip supports timed tasks.
- Digital Isolation: Prevents external signal interference to the control chip.
- Integrated Power Isolation: Provides stable isolated voltage without requiring additional power supply for isolated terminals.
- Expansion: On-board pin interface for connecting other devices and modules.

3. Setup Instructions
3.1. Package Contents
- ESP32-S3-RS485-CAN Module x 1
- SH1.0 4PIN connection wire (approx. 150mm) x 1
- Screwdriver x 1

3.2. Physical Installation
The module features a rail-mount type protective shell, designed for easy installation in industrial control cabinets or similar setups. Simply clip the module onto a standard DIN rail.
3.3. Power Connection
The module can be powered via two methods:
- Terminal Block: Connect a DC power supply within the range of 7V to 36V to the VCC (positive) and GND (negative) terminals on the upper terminal block.
- USB Type-C: Connect a 5V USB power source to the USB Type-C port. This port also serves for firmware download and debugging.
3.4. Interface Connections
The module provides various interfaces for communication and expansion:

- RS485 Interface: Connect RS485 devices to the A+ and B- terminals on the lower terminal block. The module supports automatic direction control.
- CAN Interface: Connect CAN devices to the H and L terminals on the lower terminal block. Hardware automatically identifies and controls data transmission direction.
- USB Type-C Port: Used for power supply, firmware download, and USB communication.
- SH1.0 4PIN Connector: Connects to rechargeable RTC battery (not included) for timed tasks.
- Pin Header Interface (2.0mm pitch): Provides access to GPIO pins (GPIO1, GPIO2) for connecting other functional modules.
3.4.1. Terminal Pinout Summary
Upper Terminal Block:
- VCC: Power supply positive terminal (DC 7V to 36V)
- GND: Power supply negative terminal
Lower Terminal Block:
- RS485: A+ (A+ signal pin), B- (B- signal pin)
- CAN: H (H signal pin), L (L signal pin)
SH1.0 Interface Pinouts:
- GPIO1: SH1.0 Interface Pinout
- GPIO2: SH1.0 Interface Pinout
Additional GPIOs (via internal pin headers, refer to Resource Overview for exact locations):
- GPIO15: CAN TX Pin
- GPIO16: CAN RX Pin
- GPIO17: RS485 TX Pin
- GPIO18: RS485 RX Pin
- GPIO21: RS485 EN Pin
4. Operating Instructions
4.1. Indicator Lights
The module is equipped with on-board indicator lights to monitor its operational status:
- PWR (Power Indicator): A red light illuminates when voltage is detected, indicating the module is powered on.
- RS485 Indicator: A green light illuminates when data is transmitted from the RS485 interface. A blue light illuminates when data is received via the RS485 interface.
- CAN Indicator: This light flashes when data communication occurs on the CAN interface.

4.2. Communication
The ESP32-S3-RS485-CAN module supports multiple communication protocols:
- RS485: For industrial serial communication, compatible with Modbus protocols.
- CAN: For robust vehicle and industrial automation networks.
- Wi-Fi (2.4GHz): For wireless network connectivity, enabling IoT applications and remote control.
- Bluetooth 5 (LE): For short-range wireless communication with low power consumption.
4.3. Firmware and Development
The USB Type-C port allows for easy firmware download and debugging. Developers can utilize the ESP-IDF framework or Arduino IDE to program the ESP32-S3 microcontroller for custom applications.
4.4. Application Scenarios
The module is versatile and can be used in various applications:
- Interlock Control: A host computer can communicate wirelessly with the module, which then controls CAN devices (e.g., sensors, expansion modules) and RS485 devices (e.g., sensors, Modbus modules). This allows for centralized control and data exchange in industrial automation systems.
- IoT Connectivity: The module can act as an IoT gateway. It connects to the internet via Wi-Fi (STA mode) and creates its own Wi-Fi Access Point (AP mode) to communicate with local devices. It can interface with RS485 and CAN devices, and other Wi-Fi routing devices, enabling data visualization services through web pages accessible from user devices (mobile/PC).
5. Maintenance
The Diymore ESP32-S3-RS485-CAN module is designed for industrial environments and requires minimal maintenance.
- Cleaning: Ensure the module is powered off before cleaning. Use a soft, dry cloth to wipe the exterior. Avoid using liquid cleaners or solvents.
- Environment: Operate the module within its specified temperature and humidity ranges to ensure optimal performance and longevity.
- Connections: Periodically check all terminal connections to ensure they are secure, especially in environments with vibration.
6. Troubleshooting
- No Power (PWR LED Off):
- Check if the 7V-36V DC power supply is correctly connected to the VCC and GND terminals and is within the specified voltage range.
- If using USB-C, ensure the 5V power source is connected and functional.
- Verify the power source itself is working.
- No RS485 Communication (RS485 LEDs not lighting up):
- Ensure RS485 A+ and B- terminals are correctly wired to the RS485 device.
- Check the communication parameters (baud rate, parity, stop bits) in your software.
- Verify the RS485 device is powered and functional.
- Ensure the RS485 terminating resistor (120R) is correctly enabled if needed for your bus topology (default is NC, reserved 120R can be enabled by jumper cap).
- No CAN Communication (CAN LED not flashing):
- Ensure CAN H and L terminals are correctly wired to the CAN device.
- Check the CAN bus termination (pre-installed 120R termination resistor, enabled via jumper cap).
- Verify the CAN device is powered and functional.
- Check the CAN bus speed settings.
- Wi-Fi/Bluetooth Connectivity Issues:
- Ensure the module's firmware supports Wi-Fi/Bluetooth functionality and is correctly configured.
- Check for Wi-Fi signal strength and interference.
- Verify correct SSID and password for Wi-Fi connections.
- Ensure Bluetooth devices are in pairing mode and within range.
- Module Not Responding:
- Try pressing the Device Reset Button.
- If issues persist, try reflashing the firmware via the USB Type-C port.
7. Specifications
| Parameter | Value |
|---|---|
| Model | ESP32-S3-RS485-CAN |
| Microcontroller | ESP32-S3 (Xtensa 32-bit LX7 dual-core, up to 240MHz) |
| Wireless Communication | 2.4GHz Wi-Fi (802.11 b/g/n), Bluetooth 5 (LE) |
| USB Interface | USB Type-C |
| Supply Voltage (Terminal) | DC 7V ~ 36V |
| Supply Voltage (USB) | DC 5V |
| RS485 Interface | Isolated, Terminal Block, Automatic Direction Control |
| CAN Interface | Isolated, Terminal Block, Hardware Auto-Direction Control |
| Interface Protection | TVS tube protection, surge and electrostatic protection |
| Matching Resistor | Default NC, reserved 120R (jumper cap enabled) |
| Shell Type | Rail type protective shell |
| Dimensions | 91.6 mm * 23.3 mm * 58.7 mm |
| Flash Memory | 16MB |

8. User Tips
- For stable industrial applications, always use the terminal block power input (7V-36V) rather than relying solely on USB power.
- When integrating into a larger system, consider the placement of the module to optimize Wi-Fi and Bluetooth signal strength, especially if using an external antenna.
- Utilize the on-board indicator lights as a first step in diagnosing communication issues before checking wiring or software configurations.
- For long RS485 or CAN bus lines, ensure proper termination resistors are enabled to prevent signal reflections.
9. Warranty and Support
For warranty information, technical support, and further documentation, please refer to the official Diymore product page or contact your vendor. Keep your purchase receipt for warranty claims.