myoslim EMS RF 15 Tesla 6500W Body Sculpting Machine

Contents

Professional EMS RF 15 Tesla 6500W Body Sculpting Machine User Manual

Model: EMS RF 15 Tesla 6500W Body Sculpting Machine

Brand: myoslim

1. General Information

1.1 Product Overview

The myoslim EMS Body Sculpt series utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.

1.2 Key Features

  • Advanced HI-EMT Technology: Utilizes high-energy focused electromagnetic waves for intense muscle contractions, promoting muscle growth and deep internal structural reshaping.
  • Touch-Controlled Display: Simplifies device operation with clear visibility and adjustable brightness for various lighting conditions.
  • Real-time Monitoring and Guidance: Displays remaining treatment time, utilized channels, treatment methods, applied treatment types, and other necessary information for monitoring progress.
  • Upgradeability: Offers flexible upgrade options to meet evolving therapeutic needs.

1.3 Intended Use

The EMS Body Sculpt machine is intended for:

  • Improvement of abdominal tone, strengthening of abdominal muscles, and development of a fitter abdomen.
  • Strengthening, toning, and firming of buttocks, thighs, and calves.
  • Improvement of muscle tone and firmness, particularly for strengthening muscles in arms.

For a more detailed guide, please refer to the official user manual PDF: Item guides & documents (PDF)

2. Safety Precautions and Warnings

2.1 Precautions Before Use

  • Do not use when feeling full; wait at least one hour after meals.
  • Remove any metal jewelry before using the instrument.
  • Before starting operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
  • Start at the lowest intensity level and gradually increase it based on the user's skin tolerance.
  • It is forbidden to eat or drink during the operation. Wait at least one hour after the operation before eating.

2.2 Contraindications

Do NOT use this device if any of the following apply:

  • Open wounds on the skin (or avoid wounds when using).
  • Patients with heart disease (e.g., arrhythmias), especially those with pacemakers.
  • Cancer patients.
  • Patients with infectious diseases.
  • Pregnant women, lactating women, or during menstrual period.
  • Patients who have undergone major surgery or have diabetes.
  • Presence of any metal in the body (implants).
  • People with cerebrovascular disease (e.g., stroke patients).

2.3 Possible Side Effects

These effects may include but are not limited to:

  • Muscle soreness.
  • Reduction in muscle fat.
  • Temporary muscle spasms.
  • Transient joint or muscle tendon pain.
  • Localized redness or skin flushing.

3. Product Components and Accessories

3.1 Main Unit Panels

The device features a front panel with a display screen and controls, and a rear panel for connections and switches.

Front view of the myoslim EMS Body Sculpting Machine with handles attached.
Figure 1: Front view of the myoslim EMS Body Sculpting Machine with handles.
Rear view of the myoslim EMS Body Sculpting Machine showing power input and switch.
Figure 2: Rear view of the myoslim EMS Body Sculpting Machine.

3.2 List of Accessories

SerialNameQuantityPicture
1Host1 set(Image not provided)
2Handle2(Image not provided)
Cushion (optional accessories)1(Image not provided)
3Belts (8*80CM, 8*90CM, 8*100CM)3(Image not provided)
4Power cable1(Image not provided)
5Electronic manual1 copy(Image not provided)

4. Device Installation

  1. Install the handle bracket: Use a screwdriver to install the handle brackets on both sides of the machine.
  2. Handle film: Apply the black film to the working part of the handle.
  3. Installing the handle: Align the hole and fasten the clip. Lock the key ring.
  4. Connect power: Connect one end of the power cord to the machine and the other end to the socket.
  5. Power On:
    • Press the switch button on the back of the machine (light will turn on).
    • Press the power button on the front panel (single-click to power on).
Video 1: Demonstrates turning on the machine and basic screen navigation.

5. Operating Instructions

5.1 Handle Exchange

The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.

5.2 Device Start-up/Shut Down

  1. Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
  2. Move the manual switch on the rear panel to the "o" position.
  3. Press the button on the front panel.
  4. When the treatment is finished, press and hold the power button to turn off the machine.

5.3 Navigation Controls and Therapy Settings

The machine offers two main modes (Mode 1 and Mode 2) for therapy, allowing adjustment of energy levels and other parameters. The language settings can also be adjusted.

Machine screen showing Pattern 1 settings with intensity and time adjustments.
Figure 3: Screen interface for Pattern 1, showing energy and time adjustments.
Machine screen showing language selection options.
Figure 4: Screen interface for language settings.

Mode 1 Operation:

The operation interface of Mode 1 allows you to adjust the energy levels for the handles. After setting, click the start button to begin the treatment. If the customer requests to pause, you can click start/pause. The work button suspends the work, and you can directly click the back button to return after the work is completed. The frequency range for Mode 1 is 5-60Hz.

Mode 2 Operation:

Mode 2 offers more detailed data adjustments, allowing for precise control over the energy of each pair of handles. It also features 3 different periods of frequency for free adjustment. The frequency range for Mode 2 is 30-100Hz.

5.4 Preparing for Therapy and Placing the Handles

  1. Communicate with patients: Ensure they understand the procedure and are comfortable.
  2. Ensure good health: Confirm the patient is in good health and has no contraindications.
  3. Stay hydrated: Advise the patient to be well-hydrated before the session.
  4. Wear appropriate clothing: Ensure the patient wears comfortable clothing that allows for proper handle placement.
  5. Avoid eating in large quantities: Advise against heavy meals before the session.
  6. Familiarize with the treatment process: Ensure both operator and patient understand the steps.
  7. Avoid drinking alcohol: Advise against alcohol consumption before the session.

Handle Placement:

Tie the large handles around the abdomen or hips. Use the curved handles around the legs or hands, securing them with the provided belts.

Diagram showing proper placement of handles on the abdomen and buttocks.
Figure 5: Handle placement for abdomen and buttocks.
Diagram showing proper placement of handles on arms, thighs, and calves.
Figure 6: Handle placement for arms, thighs, and calves.

6. Maintenance

6.1 Daily Inspection

  • Regularly inspect instruments and components.
  • Check if the power socket has a reliable connection to the ground.
  • Inspect the power cord for any damage before use. Stop using the instrument if damaged.

6.2 Cleaning

  • Device Surface: The machine's logo is silk screen printed. Other painted parts can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. Do not use alcohol-based detergents.
  • Accessories (Skin Contact): Parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after each use. Do not soak them in alcohol-based detergent; wipe with pure cotton material.

6.3 Fuse Replacement

The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included. To prevent electric shock, always turn off the power and unplug the power plug before replacing the fuse.

6.4 Transport and Storage

  • Storage: Store the instrument in its original packaging box, in a well-ventilated room. The packaging box should be padded. Ambient temperature should be -10°C to 40°C, relative humidity not greater than 93%. Avoid harmful gases, flammable, explosive, and corrosive substances.
  • Transportation: The instrument is suitable for road, railway, air, and water transportation. During loading, unloading, and transportation, prevent severe vibration and shock. Protect from moisture. Do not mix with flammable, corrosive substances. Specific requirements are detailed in the order contract.

7. Troubleshooting

Fault PhenomenonCausesExclusions and Workarounds
Device not workingThe power plug is not inserted into the socket
Power switch not on
Power fuse failure
Check the power
Check the power switch
Replace the fuse
Handle not workingCheck the handle for loose connectionReseat the handle

8. Technical Specifications

AttributeSpecification
Product NameEMSzero Body Sculpt Machine, EMS HIEMT Body Slimming Sculpting Machine
Brand Namemyoslim
Item TypeMassage & Relaxation
Power TypeElectric
Power SourceFrom mains or battery
Input Power SupplyAC110V-220V 50/60Hz
VoltageAC220V/50Hz AC110V/60Hz
Output Maximum Power0-6500W
Frequency5-200HZ
Screen Size23.8 inches
MaterialABS
Machine ColorBlack
OriginMainland China
CertificationCE, RoHS
TechnologyEMS/HIEMT+RF 2 in 1 Slimming, High Intensity Pulsed Electromagnetic Body Sculpting
Technology AdvantageNo-invasive non-exercise healthy slimming
Functionsbody contouring, body slimming, body sculpt, muscle build, fat removal, skin tight, butt lift, muscle build, muscle stimulation, EMS Cellulite Reductions
Handle OptionsEMSzero 2/4/5 handles Optional
Target AreaBody, Legs/Arms, Hands, Abdomen, Hips

8.1 Electromagnetic Compatibility (EMC)

The device has been tested for electromagnetic compatibility according to IEC 61000-4-3:2020 standards. It operates at a test level of 30V/m with 80% AM, 1kHz Modulation. The test setup involves a 7x4x3 meter chamber with EUT (Equipment Under Test) and support, power amplifier, signal generator, and EUT monitoring via camera.

Block diagram of the electromagnetic compatibility test setup.
Figure 7: Representative image of the EMS Body Sculpting Machine, used as a placeholder for the EMC test setup diagram (actual diagram not provided in source data).

9. Warranty and Support

9.1 Warranty Information

  • The machine can be replaced with a new one within 7 days from the date of purchase (with receipt) if its appearance is intact.
  • The main machine is guaranteed for one year (excluding fragile parts, non-warranty scope, or expired warranty period).
  • Accessories have a warranty period of 3 months (note: man-made damage is excluded).
  • Maintenance and updates are available, with appropriate fees charged.
  • If the instrument is broken and needs to be sent back for repair, the buyer bears the return shipping cost within six months of purchase. After six months, the buyer bears all shipping costs.
  • Continued use beyond the service period requires approval from an engineer and periodic performance tests.
  • Scrap instruments and accessories beyond their useful life should be disposed of according to local regulations.

9.2 Exclusions from Free Warranty Service

Free warranty service is not provided for failures caused by:

  • Unauthorized disassembly and modification of the product.
  • Accidental fall.
  • Lack of reasonable maintenance.
  • Failure to operate according to the correct instructions in this manual.

9.3 After-sales Service

  • Video technical support and online support are available.
  • 24 hours online service and instructional operation video training are provided.
  • For any repair needs, contact the manufacturer directly to provide paid after-sales service. Do not repair the machine without authorization.

9.4 Manufacturer

Guangzhou Xinwei Electronic Technology Co., Ltd.

10. User Tips & FAQ

10.1 User Tips

  • The product is generally well-packaged and of good quality.
  • If you have questions about operation, the seller is responsive and helpful.
  • Ensure to follow the energy adjustment guidelines: start low and gradually increase based on comfort.

10.2 Frequently Asked Questions

Q: Is the product MDR compliant?

A: The seller states that the products are CE-certified and have passed various tests, ensuring quality and safety.

Q: Where can I get the full manual?

A: Please contact the seller online for the full manual or any specific documentation.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.