1. Product Description
The MOES Smart Liquid Level Sensor is an integrated sensing device designed for accurate and real-time monitoring of liquid height or volume within tanks, vessels, or other containers. It utilizes a built-in microprocessor to intelligently process, analyze, compensate for, and diagnose raw data. Key information, such as real-time liquid level and alarm status, is displayed directly on the MOES App. This system significantly enhances storage and transportation safety by preventing risks of tank overflow or dry-run operation.
This product is available in two versions: WiFi (ME201W) and Zigbee (ME201WZ). The Zigbee version requires a Zigbee gateway (hub) for functionality.
2. Package Contents
- Liquid level sensor × 1
- Screws × 4
- Gasket × 1
- EU adapter × 1
- Sensor cable × 1 (4 meters long)
- User Manual × 1
3. Safety Warnings
Do not disassemble, reassemble, modify, or attempt to repair this product by yourself. All maintenance and repair work should be performed by authorized professionals only.
4. Technical Specifications
| Model | ME201W (WiFi) / ME201WZ (Zigbee) |
| Adaptor | AC 110-240V |
| Sensor Power Supply | ≤100mA @ 5V DC |
| Level Range | 0m – 5m |
| Accuracy | ± 0.02m |
| Operation Temperature | -20°C – 70°C |
| Protection Rating | IP65 |
| Wireless Protocol | WIFI / ZIGBEE (2.4G WiFi / Zigbee 3.0) |
| Frequency Band | 2.412-2.484GHz |
| Maximum Radio Transmit Power | <+16 dBm |
| Touch Key Function | Press 5 seconds for WiFi connection / reset/re-pair device |
| LED Status (Config) | Flashes rapidly |
| LED Status (Connected) | Light on |
| LED Status (Not Connected) | Flashes slowly |
Dimensions
The sensor measures approximately 40mm (1.57in) in height and 80mm (3.15in) in width.
5. Installation and Setup
5.1. Precautions Before Installation
Visual guide for proper sensor placement.
- Hold the sensor perpendicular to the liquid surface for accurate readings.
- Install the sensor away from the water inlet to prevent pseudo-echoes, which can lead to inaccurate measurements.
- The sensor installation must not be too close to the tank's bulkhead, as this can also cause a strong pseudo-echo.
- Ensure there are no obstacles within the reflective area of the sensor to avoid interference.
- If the mounting surface is curved, fix the sensor with screws just enough to prevent it from being stressed. If data is abnormal, loosen the screws slightly.
5.2. Installation Steps
Step-by-step guide for physical installation.
- Remove the release paper from the gasket and attach the gasket to the center of the tank where the hole will be drilled.
- Drill a circular hole in the middle of the tank with a diameter between 55mm and 80mm.
- Place the sensor over the gasket, ensuring it is aligned with the screw holes and unobstructed.
- Fasten the sensor securely with the provided self-tapping screws.
5.3. Zigbee Gateway Requirement (for Zigbee version only)
Network diagram for Zigbee sensor setup.
Note: If you have purchased the Zigbee version (ME201WZ) of the sensor, a Zigbee gateway (hub) is required for its operation and connection to the MOES App. This gateway must be purchased separately.
The sensor comes with an extended 4-meter cable for flexible long-distance setup, ideal for wide or elevated installations.
The 4-meter cable allows for flexible placement of the sensor and power adapter.
6. MOES App Setup
6.1. Download the MOES App
Download the MOES App from your device's app store or scan the QR code below:
Scan to download the MOES App.
The MOES App offers enhanced compatibility and features, including scene control via Siri, widgets, and customized services. While Tuya Smart/Smart Life App may still work, MOES App is highly recommended.
6.2. Registration or Login
- Open the MOES Application.
- Enter the Register/Login interface. Tap "Register" to create an account by entering your phone number, receiving a verification code, and setting a password.
- If you already have a MOES account, choose "Log in".
Note:
- If you are connected to a 5G WiFi network, please disconnect it first and connect to a 2.4G WiFi network before proceeding with device setup.
6.3. How to Reset/Re-pair Device
To reset or re-pair the device, press the Touch Key on the sensor for 5 seconds. The LED light status will indicate the connection mode:
- **WiFi Config:** LED light flashes rapidly.
- **WiFi Connected:** LED light is on.
- **WiFi Not Connected:** LED light flashes slowly.
6.4. Steps for Connecting the APP to the Device
For Zigbee Edition:
- Ensure your MOES APP has successfully connected to a Zigbee gateway.
- Add the device successfully. You can then edit the device name and enter the device page by clicking "Done".
- Click "Done" again to enter the device page and enjoy smart life with home automation.
For WiFi Edition:
- Make sure your phone is connected to Wi-Fi (2.4GHz) and Bluetooth is enabled.
- Open the MOES App, click the "+" in the upper right corner, then select "Add Device". The device should appear in "discovering devices". Click "Add".
- Enter your Wi-Fi Password and click "Next". Wait for the connection to complete. Once the device is successfully added, you can edit its name and enter the device page by clicking "Done". Enjoy your smart life with home automation.
7. Operating Instructions
7.1. Real-time Monitoring
The MOES App provides real-time monitoring of your liquid level. You can view the liquid level ratio, current liquid depth, liquid level status (Normal, Full alarm, Lower alarm), and supply voltage directly from the app interface.
Real-time liquid level data displayed in the MOES App.
7.2. Instant Alerts
The app provides instant alerts for various liquid level statuses, such as normal, full alarm, and low alarm, ensuring you are always informed about your tank's conditions.
Examples of instant alerts for different liquid levels.
7.3. Customizable Water Level Thresholds
You can set custom upper and lower water level thresholds within the MOES App to enable smart overflow and dry-run prevention. The app will send alerts when these thresholds are met.
App interface for setting liquid level thresholds.
Setting Parameters:
- Installation height (A): Set the distance from the sensor to the tank bottom.
- Liquid maximum depth (B): Enter the maximum height of liquid the tank can hold.
- Set Max: Define the percentage for a high-level alarm (based on actual liquid level value C).
- Set Min: Define the percentage for a low-level alarm.
Example Calculation:
If Installation height (A) = 4m, Liquid maximum depth (B) = 3m, Actual liquid level value (C) = 2m.
Set Max = 60%, Set Min = 20%.
Level Status: Full alarm (C/B * 100% = 2/3 * 100% = 67%).
7.4. Smart Linkage
The sensor supports smart linkage with other smart home devices. For example, you can configure an automation where if the liquid level status is a "Lower alarm", a smart wall socket connected to a water pump automatically turns on to refill the tank.
Example of smart automation with the liquid level sensor.
7.5. Water Curve & History Records
The MOES App allows you to track your tank's water usage over time with intuitive water curves and detailed history logs, providing full insight into liquid level changes.
View historical data and water level trends in the app.
8. Maintenance
The MOES Smart Ultrasonic Liquid Level Sensor features an IP65 waterproof rating, ensuring reliable performance in various weather conditions, both indoors and outdoors. Regular cleaning of the sensor surface to remove any debris or buildup is recommended to maintain optimal accuracy. Do not use harsh chemicals or abrasive materials for cleaning.
The IP65 rating ensures durability in wet environments.
9. Troubleshooting
If you encounter problems installing or operating your device, please review the product data sheet for detailed guidance. The data sheet can be found at: https://www.moastech.com/blogs/news/wss-lm01
Common issues and their potential solutions:
- Inaccurate Readings: Check sensor placement (perpendicular to liquid, away from inlet/bulkhead), ensure no obstacles in the reflective area. If mounting surface is curved, adjust screw tightness.
- No App Connection (WiFi version): Ensure your phone is on a 2.4GHz WiFi network (not 5G). Press the Touch Key for 5 seconds to enter WiFi config mode (LED flashes rapidly).
- No App Connection (Zigbee version): Verify that your Zigbee gateway is properly set up and connected to the MOES App. Ensure the sensor is within range of the gateway. Press the Touch Key for 5 seconds to enter pairing mode.
- No Alerts: Check app settings for customizable thresholds and ensure notifications are enabled for the MOES App on your smartphone.
10. User Tips
- For optimal performance, ensure the sensor is installed in a location free from physical obstructions that could interfere with the ultrasonic beam.
- Regularly check the MOES App for firmware updates to ensure you have the latest features and improvements.
- Utilize the smart linkage feature to automate actions, such as turning on a pump when the water level is low, for enhanced convenience and safety.
- Review the water curve and history records in the app to understand your liquid consumption patterns and optimize usage.
11. Warranty and Support
11.1. Warranty Instructions
Your MOES product is covered by a 24-month warranty, effective from the date of purchase by a retail customer. To exercise your warranty rights, you must present a warranty card and proof of purchase (e.g., VAT invoice, financial receipt, or other document confirming the actual purchase date).
If product quality problems occur within 24 months from the date of receipt, please prepare the product and its original packaging and contact your place of purchase for after-sales maintenance. If the product is damaged due to personal reasons, a maintenance fee may be charged.
The warranty does not cover:
- Mechanical damage caused by user fault or product defects resulting from such damage.
- Damage caused by improper use of the product.
- Defects due to natural wear and tear during use.
- Removal of the warranty seal or serial number from the product.
- Attempts to eliminate physical defects outside of authorized service.
- Use of non-original parts and consumables.
For warranty claims, reported defects will be considered immediately and no later than 14 days from the date of delivery to the Guarantor. Repairs will be completed within a reasonable time, not exceeding 30 days from the date of delivery to the Guarantor. This deadline may be extended if hard-to-find spare parts are required.
11.2. Contact Information
For after-sales service and support, please contact:
- Manufacturer: WENZHOU NOVA NEW ENERGY CO., LTD
- Address: Power Science and Technology Innovation Center, NO.238, Wei 11 Road, Yueqing Economic Development Zone, Yueqing, Zhejiang, China
- Tel: +86-577-57186815
- After Service Email: service@moeshouse.com
UK Representative: EVATOST CONSULTING LTD
Address: Suite 11, First Floor, Moy Road Business Centre, Taffs Well, Cardiff, Wales, CF15 7QR
Tel: +44-292-1680945
Email: contact@evatost.com
EC Representative: AMZLAB GmbH
Address: Laubenhof 23, ESSEN 45326
Email: info@amz-lab.de
Tel: +491745298066
12. Recycling Information
All products marked with the symbol for separate collection of waste electrical and electronic equipment (WEEE Directive 2012/19/EU) must be disposed of separately from unsorted municipal waste. To protect your health and the environment, this equipment must be disposed of at designated collection points for electrical and electronic equipment designated by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences for the environment and human health. To find out where these collection points are and how they work, contact the installer or your local authority.
13. Declaration of Conformity
Hereby, WENZHOU NOVA NEW ENERGY CO., LTD declares that the radio equipment type ME201W/ME201WZ is in compliance with Directives 2014/53/EU, 2014/35/EU, 2014/30/EU, and 2011/65/EU.