DH48S-S-2Z Digital Timer Relay User Manual
Model: DH48S-S-2Z
Brand: CERTEON
1. Introduction
The DH48S-S-2Z Digital Cycle Timer Relay is a programmable time-delay control device designed for industrial automation and electrical control systems. It supports cyclic delay operation with dual output contacts, enabling delayed start, delayed stop, and repeat timing control in machinery and process applications. The device features a wide adjustable timing range and a digital display for precise configuration.
2. Safety Information and Precautions
General Precautions
- Ensure that wiring is performed by qualified personnel.
- Disconnect power before installation, wiring, or maintenance.
- Do not exceed the rated contact capacity of 250V AC 5A.
- Operate only within the specified temperature range of -10°C to +60°C.
- Install in a dry environment free from excessive dust, vibration, or corrosive gases.
- Use appropriate circuit protection devices such as fuses or circuit breakers.
Warning Information (EU Market Reference)
WARNING!
- Risk of electric shock. The device operates at hazardous voltages. Always disconnect power before handling.
- Installation must be carried out in accordance with applicable low voltage regulations and electrical safety standards.
- Do not touch live terminals during operation.
- Keep out of reach of children.
- Proper disposal: Follow WEEE directives for electronic waste.
Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.
3. Setup
Preparation
- Verify that the rated operating voltage of the device matches the supply voltage.
- Install the relay securely inside an electrical control cabinet with adequate ventilation.
Wiring Diagram
Ensure correct wiring according to the terminal diagram. Refer to the diagram below for proper connections.
4. Operation
Basic Operation
- Apply power to the device.
- Set the required timing range using the front panel controls.
- Adjust the desired delay time within the 0.1 second to 99 hour range.
- Select the cycle delay mode as required by the application.
Data Reading
- The digital display shows the configured timing value.
- During operation, the display indicates the active timing countdown or cycle status.
- Confirm that output contacts switch according to the programmed cycle sequence.
5. Specifications
| Feature | Description |
|---|---|
| Model Number | DH48S-S-2Z |
| Power Supply Options | AC220V, AC/DC24V, AC/DC12V, AC380V, AC110V, AC36V |
| Rated Frequency | 50/60Hz |
| Operating Temperature | -10°C to +60°C |
| Time Setting Range | 0.1 seconds to 99 hours |
| Timing Mode | Cycle delay |
| Contact Configuration | 2 normally open (NO) contacts and 2 normally closed (NC) contacts |
| Contact Capacity | 250V AC 5A |
| Display Type | Digital LED display |
| EU LVD Voltage | High voltage: Above 50Vac or 75Vdc |
| High-concerned chemical | None |
| Origin | Mainland China |
| Altitude Limit | Less than 2000 meters |
| Package Dimensions (L x W x H) | 12 cm x 8 cm x 8 cm |
| Package Weight | 0.5 kg |
6. Maintenance
Storage
- Store the device in a dry and ventilated environment.
- Avoid exposure to moisture, direct sunlight, and strong electromagnetic interference.
- If the device is not used for an extended period, disconnect it from the power supply and store it in original packaging where possible.
Cleaning
- Clean the surface with a dry soft cloth.
- Do not use solvents or corrosive cleaning agents.
7. Troubleshooting
If you encounter issues with your DH48S-S-2Z Digital Timer Relay, consider the following basic troubleshooting steps:
- Device not powering on: Check the power supply connection and ensure the voltage matches the device's rated voltage. Verify that circuit protection devices (fuses/breakers) are not tripped.
- Incorrect timing or contacts not switching: Review your wiring against the provided diagram. Double-check the time settings and timing mode configured on the front panel. Ensure the load connected does not exceed the contact capacity.
- Intermittent operation: Ensure the device is installed in a dry environment free from excessive vibration or electromagnetic interference.
For persistent issues, refer to the detailed PDF manual or contact support.
8. User Tips
No specific user tips are available from customer reviews or Q&A at this time. Always ensure proper voltage selection and secure wiring for optimal performance.
9. Frequently Asked Questions (FAQ)
No frequently asked questions are available from customer Q&A at this time.
10. Warranty and Support
For detailed information, including a comprehensive user manual, please refer to the official PDF document:
For technical support or inquiries, you may contact CERTEON via:
- WhatsApp: +86 19542723588
- Email: celiachen008@gmail.com