1. Introduction
This manual provides essential information for the safe and efficient operation of your DIXSG Wideband Power Amplifier (PA) Module. Please read this manual thoroughly before installation and use, and keep it for future reference.
2. Safety Information
- Ensure proper power supply voltage and current as specified for your module variant to prevent damage.
- Avoid operating the module without a proper load (antenna or dummy load) connected to the RF OUT port.
- Do not exceed the maximum input RF power to prevent damage to the amplifier.
- Ensure adequate heat dissipation, especially for higher power modules. Consider additional heatsinking if operating in high ambient temperatures or at maximum output power.
- Handle with care to avoid electrostatic discharge (ESD) damage.
- Keep the module away from moisture and extreme temperatures.
3. Package Contents
Upon unpacking, please verify that all items are present and undamaged:
- DIXSG Wideband PA Module (specific power variant)
- (No other accessories explicitly listed, assume module only)
4. Product Overview
The DIXSG Wideband PA Module is designed to amplify RF signals across a broad frequency range (100-7000MHz). It is available in various output power configurations from 5W to 50W.

Figure 1: DIXSG Wideband PA Modules (5W-50W, 100-7000MHz)
Module Layout

Figure 2: Top View - RF Input and Output Ports
- RF IN: SMA-K (Female) connector for RF signal input.
- RF OUT: SMA-K (Female) connector for amplified RF signal output.
- Power Input: Red and Black wires (AWG18) for DC power supply.
- Control Line: Red wire for remote ON/OFF functionality.

Figure 3: Power Input Wires (VCC, GND)

Figure 4: RF Output and Power/Control Wiring
5. Setup Instructions
- Mounting: Securely mount the PA module in a suitable enclosure or on a heatsink (if required, especially for 5W variant or high power operation). Ensure good airflow around the module.
- RF Connections:
- Connect your RF signal source to the RF IN SMA-K (Female) connector.
- Connect your antenna or dummy load to the RF OUT SMA-K (Female) connector. Ensure the load is matched (typically 50 Ohm) and capable of handling the module's output power.
- Power Connection:
- Connect the Red power wire to the positive (+) terminal of your DC power supply.
- Connect the Black power wire to the negative (-) terminal (GND) of your DC power supply.
- Ensure your power supply provides the correct voltage and sufficient current as specified for your module variant (refer to Specifications section).
- Control Line (Optional):
- The separate Red control wire can be connected to a 3-28V (or 3-24V for 20W) DC source to remotely turn the amplifier ON/OFF. If not used, ensure it is properly isolated to prevent accidental activation or shorting.
- Initial Check: Double-check all connections before applying power.
6. Operating Instructions
- Apply Power: Turn on your DC power supply. The LED indicator on the module should illuminate Red, indicating it is operating.
- Apply RF Input: Introduce your RF signal to the RF IN port.
- Monitor Output: Verify the amplified RF signal at the RF OUT port using appropriate test equipment (e.g., spectrum analyzer, power meter).
- Remote ON/OFF (if used): Apply the specified voltage to the control line to enable the amplifier, or remove the voltage to disable it.
- Power Down: First, remove the RF input signal, then turn off the DC power supply.
7. Maintenance
- Cleaning: Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
- Connections: Periodically check all RF and power connections for tightness and corrosion.
- Environment: Ensure the operating environment remains within specified temperature and humidity ranges.
- Heat Dissipation: Regularly check that heatsinks (if used) are free from obstructions and are effectively dissipating heat.
8. Troubleshooting
- No Output Power:
- Check DC power supply voltage and current.
- Ensure power wires are correctly connected (polarity).
- Verify the control line (if used) is correctly activated.
- Check RF input signal presence and level.
- Ensure RF IN/OUT cables are properly connected and not damaged.
- Low Output Power:
- Check RF input signal level.
- Verify load impedance (RF OUT) is 50 Ohm.
- Ensure operating voltage is within specifications.
- Check for excessive heat, which can cause thermal throttling.
- Module Overheating:
- Ensure adequate ventilation and heatsinking.
- Verify load impedance is correct.
- Check for excessive input power.
9. Specifications
Specifications vary by module power variant. Please refer to the specific table for your model.
9.1. 5W PA Module Specifications
| Parameter | Value |
|---|---|
| Output Power (P1dB) | 37 dBm (5 W) |
| Gain (S21) | 35 dB ± 1 |
| Input Return Loss (S11) | ≤ -15 dB |
| RF Input Power Range | -13 dBm to +10 dBm |
| Efficiency | ≥ 45% @ 37dBm |
| Operating Voltage | 22 - 28 V DC |
| Current Consumption | ~0.45 A @ 24V, 37dBm Output |
| LED Indicator | Red (Operating) |
| RF Connectors (Input/Output) | SMA-K (Female) |
| Power Connector | XT-30 with AWG18 20cm Red/Black Wire |
| Control Line | 3-28V 20cm Red Wire (remote on/off) |
| Heatsink | 3mm Aluminum (optional) |
| PCBA Dimensions | 69 x 38 x 4 mm |
| With Heatsink Dimensions | 69 x 38 x 7 mm |
| Net Weight (PCBA only) | 8.7 g |
| Net Weight (with Heatsink) | 38 g |
| Operating Temperature | -30°C ~ +85°C |
| Storage Temperature | -40°C ~ +150°C |
9.2. 10W PA Module Specifications
| Parameter | Value |
|---|---|
| Output Power (P1dB) | 40 dBm (10 W) |
| Gain (S21) | 38 dB ± 1 |
| Input Return Loss (S11) | ≤ -15 dB |
| RF Input Power Range | -13 dBm to +10 dBm |
| Efficiency | ≥ 45% @ 40dBm |
| Operating Voltage | 24 - 28 V DC (Wide range 24-32V supported) |
| Current Consumption | ~0.8 A @ 28V, 40dBm Output |
| LED Indicator | Red (Operating) |
| RF Connectors (Input/Output) | SMA-K |
| Power Connector | AWG18 20cm Red/Black Wire |
| Control Line | 3-28V 20cm Red Wire (for remote on/off) |
| Operating Temperature | -30°C ~ +85°C |
| Storage Temperature | -40°C ~ +150°C |
| Operating Humidity | < 95% RH |
| Dimensions | 90 x 46 x 17 mm |
| Shell Material & Finish | Aluminum, CNC Machined + Nickel Plating + Gilding Process |
| Net Weight | 120 g |
9.3. 20W PA Module Specifications
| Parameter | Value |
|---|---|
| Output Power (P1dB) | 43 dBm (20 W) |
| Gain (S21) | 40 dB ± 1 |
| Input Return Loss (S11) | ≤ -15 dB |
| RF Input Power Range | -13 dBm to +10 dBm |
| Efficiency | ≥ 45% @ 43dBm |
| Operating Voltage | 24 V DC |
| Current Consumption | ~1.8 A @ 24V, 43dBm Output |
| LED Indicator | Red (Operating) |
| RF Connectors (Input/Output) | SMA-K (Female) |
| Power Connector | AWG18 20cm Red/Black Wire |
| Control Line | 3-24V 20cm Red Wire (remote on/off) |
| Operating Temperature | -30°C ~ +85°C |
| Storage Temperature | -40°C ~ +150°C |
| Operating Humidity | < 95% RH |
| Shell Material | Aluminum |
| Shell Dimensions | 132 x 53 x 17 mm |
| Net Weight | 210 g |
9.4. 30W PA Module Specifications
| Parameter | Value |
|---|---|
| Output Power (Psat) | 45 dBm (30 W) |
| Gain (S21) | 40 dB ± 1 |
| Input Return Loss (S11) | ≤ -15 dB |
| RF Input Power Range | -13 dBm to +10 dBm |
| Power Added Efficiency | ≥ 45% @ 45dBm |
| Operating Voltage | 28 V DC |
| Current Consumption | ~2.4 A @ 28V, 45dBm Output |
| LED Indicator | Red (Operating) |
| RF Connectors (Input/Output) | SMA-K (Female) |
| Power Connector | AWG18 20cm Red/Black Wire |
| Control Line | 3-28V 20cm Red Wire (Remote On/Off) |
| Operating Temperature | -30°C ~ +85°C |
| Storage Temperature | -40°C ~ +150°C |
| Ingress Protection | IP54 (Dust & Splash Resistant) |
| Shell Material | Aluminum, Nickel-Plated |
| Shell Dimensions | 132 x 53 x 17 mm |
| Net Weight | 210 g |
9.5. 40W PA Module Specifications
| Parameter | Value |
|---|---|
| Output Power (Psat) | 46 dBm (40 W) |
| Gain (S21) | 40 dB ± 1 |
| Input Return Loss (S11) | ≤ -15 dB |
| RF Input Power Range | -13 dBm to +10 dBm |
| Power Added Efficiency | ≥ 45% @ 46dBm |
| Operating Voltage | 28 V DC |
| Current Consumption | ~3.2 A @ 28V, 46dBm Output |
| LED Indicator | Red (Operating) |
| RF Connectors (Input/Output) | SMA-K (Female) |
| Power Connector | AWG18 20cm Red/Black Wire |
| Control Line | 3-28V 20cm Red Wire (Remote On/Off) |
| Operating Temperature | -30°C ~ +85°C |
| Storage Temperature | -40°C ~ +150°C |
| Ingress Protection | IP54 (Dust & Splash Resistant) |
| Shell Material | Aluminum, Nickel-Plated |
| Shell Dimensions | 132 x 53 x 17 mm |
| Net Weight | 210 g |
9.6. 50W PA Module Specifications
| Parameter | Value |
|---|---|
| Output Power (Psat) | 47 dBm (50 W) |
| Gain (S21) | 40 dB ± 1 |
| Input Return Loss (S11) | ≤ -15 dB |
| RF Input Power Range | -13 dBm to +10 dBm |
| Power Added Efficiency | ≥ 45% @ 47dBm |
| Operating Voltage | 28 V DC |
| Current Consumption | ~3.8 A @ 28V, 47dBm Output |
| LED Indicator | Red (Operating) |
| RF Connectors (Input/Output) | SMA-K (Female) |
| Power Connector | AWG18 20cm Red/Black Wire |
| Control Line | 3-28V 20cm Red Wire (Remote On/Off) |
| Operating Temperature | -30°C ~ +85°C |
| Storage Temperature | -40°C ~ +150°C |
| Ingress Protection | IP54 (Dust & Splash Resistant) |
| Shell Material | Aluminum, Military-Spec Nickel-Plated |
| Shell Dimensions | 132 x 53 x 17 mm |
| Net Weight | 210 g |
10. User Tips
- Always ensure a proper 50 Ohm load is connected to the RF OUT port before applying power to prevent damage.
- For higher power modules, consider mounting the unit on an external heatsink or within a well-ventilated enclosure to maintain optimal operating temperatures.
- Double-check power supply polarity and voltage to match the module's requirements precisely.
11. Warranty and Support
For detailed product information, technical support, or warranty inquiries, please refer to the official product documentation or contact your vendor.
An additional user manual in PDF format may be available for download: View User Manual (PDF)