VaneAims FXB-VA5+1

Contents

VaneAims FXB-VA5+1 5-in-1 Digital Voltage Protector User Manual

Model: FXB-VA5+1 / FXB-VA5+1-G

Introduction

The VaneAims FXB-VA5+1 series is a multi-functional intelligent protector designed for Din Rail mounting. It provides comprehensive protection against over-voltage, under-voltage, and over-current conditions, while also offering real-time display of voltage, current, frequency, power, and energy consumption (kWh). This device ensures the safety and stability of your electrical systems.

VaneAims FXB-VA5+1 Digital Voltage Protector in white and dark gray casings
VaneAims FXB-VA5+1 Digital Voltage Protector, available in white and dark gray casings.

Product Advantages

  • Improved button design for easier pressing.
  • Passcode Lock Settings (Factory default: 112) for enhanced security.
  • Higher-resolution screen for clear display.
  • Measures and displays values in real-time on the screen.
  • 35mm Din Rail Mounting with securing clips for easy installation.
Diagram highlighting product advantages including improved buttons, passcode lock, high-resolution screen, real-time display, and 35mm DIN rail mounting.
Key advantages of the VaneAims FXB-VA5+1 device.

Setup and Installation

Wiring Diagram

Ensure all power is disconnected before attempting installation. Connect the device according to the following diagram:

Wiring diagram for the VaneAims FXB-VA5+1 showing IN (N, L) and OUT (N, L) connections, along with display elements and protection features.
Wiring connections and display overview for the device.
  • IN Terminals: Connect the incoming Neutral (N) and Live (L) wires to the 'IN' terminals.
  • OUT Terminals: Connect the load's Neutral (N) and Live (L) wires to the 'OUT' terminals.
  • Ensure all connections are secure and properly insulated.

DIN Rail Mounting

The device is designed for easy installation on a standard 35mm DIN rail, commonly found in household distribution boxes. It is equivalent in size to a regular 2P circuit breaker.

Image showing the VaneAims FXB-VA5+1 installed on a 35mm DIN rail within a household distribution box.
Example of DIN rail installation in a distribution box.

Operating Instructions

Display Functions

The device features a digital display that shows the following parameters:

  • Voltage Display: Shows the current voltage (V).
  • Current Display: Shows the current amperage (A).
  • Frequency Display: Shows the electrical frequency (Hz).
  • kWh Display: Shows accumulated energy consumption (kilowatt-hours).
  • Power Display: Shows the current power consumption (W).

Button Functions

The device has three main buttons for navigation and settings:

  • SET: Press and hold for more than 5 seconds to enter the setting state. Short press to cycle through parameters.
  • Up/Digit+: Increases the value of the selected parameter or moves to the next digit.
  • Down/Digit-: Decreases the value of the selected parameter or moves to the previous digit.
  • ON/OFF: Toggles the output power.

Setup Menu Parameters

To access the setup menu, press and hold the 'SET' button for more than 5 seconds. Use the Up/Down buttons to adjust values and 'SET' to confirm or move to the next parameter. Pressing 'SET' again after adjusting the last parameter will save changes and exit the menu.

Detailed setup menu flow chart showing parameters P-1 to P-13 and their adjustment ranges.
Setup Menu Flow Chart.
ParameterDescriptionRange/Default
P-1Power-on delay time1s-999s
P-2Recovery delay1s-999s
P-3Overvoltage Setting230V-300V
P-4Undervoltage Setting80V-210V
P-5Voltage trip delay0.1s-10s
P-6Voltage Correction-9.5%~+9.5%V
P-7Overcurrent Setting1A-63A (or 80A/100A depending on model)
P-8Overcurrent trip delay0.1s-10s
P-9Overcurrent counter0-20 times
P-10Current adjustment-9.5%~+9.5%A
P-11Preset Power Level0-999
P-12Quick power down protectionon/off
P-13Password setting000-999 (Factory default: 112)

Video Demonstration

Watch this video for a visual guide on setting parameters and testing the device's protection features.

Video demonstrating parameter settings, overvoltage, undervoltage, and overcurrent tests for the I-63A model.

Maintenance

The VaneAims FXB-VA5+1 is designed for reliable, long-term operation with minimal maintenance. To ensure optimal performance:

  • Cleaning: Periodically wipe the device with a dry, soft cloth to remove dust and debris. Do not use liquid cleaners or solvents.
  • Inspection: Regularly inspect the wiring connections to ensure they remain tight and free from corrosion.
  • Environmental Conditions: Ensure the device operates within the specified ambient temperature and humidity ranges to prevent damage.

Troubleshooting

The device is equipped with several protection mechanisms. If the device trips or behaves unexpectedly, consider the following:

  • Over-voltage Protection: If the input voltage exceeds the set overvoltage threshold (P-3), the device will trip to protect connected equipment. Check the power supply voltage.
  • Under-voltage Protection: If the input voltage drops below the set undervoltage threshold (P-4), the device will trip. Check the power supply voltage.
  • Over-current Protection: If the current drawn by the load exceeds the set overcurrent threshold (P-7), the device will trip. Reduce the load or check for short circuits.
  • Automatic Recovery: The device is designed for automatic recovery after a fault condition clears, following the set recovery delay (P-2).
  • No Display/Power: Verify that the input power is connected correctly and is within the rated voltage range.
  • Inaccurate Readings: If readings appear incorrect, consider using the Voltage Correction (P-6) or Current Adjustment (P-10) features, or consult a qualified electrician.

Specifications

FeatureSpecification
Model NumberFXB-VA5+1 / FXB-VA5+1-G
TypeMini Voltage Relay
Supply TerminalsN, L
Rated Supply VoltageAC 220V
Rated Frequency50/60Hz
Overvoltage Setting Range (>V)AC240-300V
Undervoltage Setting Range (<V)AC140-230V
Voltage Hysteresis5V
Overvoltage Trip Delay0.5s
Voltage Accuracy<1%
Max Operating Phase Voltage350V
Max. Operating Current63A (Available in 40A/80A/100A variants)
Altitude≤2000m
Delay Time5-300s
Permissible Relative Humidity≤50% at 40°C (without condensation)
Ambient Temperature-25°C ~ +55°C
Size81*36*66mm
CertificationCE, RoHS
Is Smart DeviceNo
OriginMainland China
Table of technical specifications for the VaneAims FXB-VA5+1 device, including voltage, current, frequency, and environmental conditions.
Technical Specifications.

User Tips

  • Current Detection: Be aware that the device may have limitations in detecting very small currents. For applications requiring precise measurement of low currents, consider supplementary instrumentation.
  • Periodic Checks: For long-term reliability, it is recommended to periodically check the device's settings and functionality, especially after any power fluctuations or system changes.
  • Password Security: Remember your password (factory default: 112) to access advanced settings. If you change it, keep a secure record.

Warranty and Support

For detailed warranty information and technical support, please refer to the official user manual PDF or contact VaneAims customer service.

Official User Manual (PDF): Download User Manual (PDF)

For further assistance, please reach out to your vendor or the manufacturer directly.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.