This manual provides detailed instructions for the Diymore 4615N Battery Power Meter, an LED display/strip battery charge indicator board. It is designed to monitor the charge level of various battery types, including 12V/24V/36V/48V Li-ion, Lipo, Lithium, and Lead-acid batteries. Key features include a low voltage alarm, customizable high and low voltage settings, adjustable display backlight time, and a power-off memory function to retain battery level information.
Please read this instruction manual carefully before use. Before using the instrument, ensure that the parameters are set according to your specific battery specifications and voltage requirements. Confirming these settings are correct is crucial for accurate operation.
Safety Information and Warnings
- Operating Voltage: Do not exceed the specified operating voltage range of DC 7-55V (red display: DC 7-40V), as this may cause damage to the product.
- Environment: Use this product in a well-ventilated, rain-free, and moisture-free environment. Failure to do so may result in damage.
- Design Protection: This product is protected by a design patent. Unauthorized imitation is prohibited and may lead to legal action.
Product Overview
The 4615N Battery Power Meter provides a clear LED display of battery voltage and charge level. It is designed for wide compatibility and ease of use.


Setup
Wiring Instructions
Connect the red wire to the positive (+) terminal of your battery and the black wire to the negative (-) terminal. Ensure a secure connection to prevent damage or inaccurate readings.


Initial Power-On
Upon initial power-on, the default voltage setting for ternary lithium batteries is L03 series voltage. You will need to configure the device for your specific battery type as described in the Operating Instructions section.
Operating Instructions
Button Functions

- Short Press: On the normal display page, a brief press of the button will turn the display on or off.
- Long Press (2 seconds): On the normal display page, pressing and holding the button for 2 seconds will enter the settings page.
Mode Settings
To enter the settings page, press and hold the button for 2 seconds from the main display. Once in the settings, short press the button to cycle through different setting modes.

1. Ternary Lithium Battery (L Series) Measurement
- From the settings page, navigate to the ternary lithium battery L03 settings page.
- Press and hold the button for 2 seconds until the battery serial number (e.g., "03") flashes.
- Short press the button to select the desired battery serial number from L03 to L12 series.
- After selecting, press and hold the button for 2 seconds to confirm. The selected serial number will remain lit and saved.
- To exit, press and hold the button for 2 seconds to return to the main page, or short press to proceed to the next settings page.
2. Lithium Iron Phosphate Battery (F Series) Measurement
- From the settings page, short press the button to switch to the F03 lithium iron phosphate battery settings page.
- Press and hold the button for 2 seconds until the battery serial number (e.g., "03") flashes.
- Short press the button to select the desired battery serial number from F03 to F14 series.
- After selecting, press and hold the button for 2 seconds to confirm. The selected serial number will remain lit and saved.
- To exit, press and hold the button for 2 seconds to return to the main page, or short press to proceed to the next settings page.
3. Lead-Acid Battery (P Series) Measurement
- From the settings page, short press the button to switch to the P12 lead-acid battery settings page.
- Press and hold the button for 2 seconds until the battery voltage (e.g., "12") flashes.
- Short press the button to select the desired battery voltage (12V/24V/36V/48V).
- After selecting, press and hold the button for 2 seconds to confirm. The selected voltage parameter will remain lit and saved.
- To exit, press and hold the button for 2 seconds to return to the main page, or short press to proceed to the next settings page.
4. Custom High and Low Voltage Settings

- From the settings page, short press the button to switch to the custom settings page.
- Low-Voltage Setting: Press and hold the button for 2 seconds until the first number on the left flashes. Short press to change the value. Press and hold for 2 seconds to move to the next digit. After setting the low-voltage value, press and hold for 2 seconds to confirm. The value will remain lit and saved.
- High-Voltage Setting: Short press the button to switch to the high-voltage settings page. Repeat the process: press and hold for 2 seconds until the first number flashes, short press to change, long press to move, and long press to confirm.
- To exit, press and hold the button for 2 seconds to return to the main page, or short press to proceed to the next settings page.
5. Display Backlight Time Setting
- From the settings page, short press the button to switch to the backlight B-0 settings page.
- Press and hold the button for 2 seconds until the numbers flash.
- Short press the button to set the backlight duration from 0 to 6.
- After selecting the parameter, press and hold the button for 2 seconds to confirm. The value will remain lit and saved.
- To exit, press and hold the button for 2 seconds to return to the main page, or short press to proceed to the next settings page.
| Setting | Description |
|---|---|
| B-0 | Backlight always on, requires manual button press to turn off. |
| B-1 | Backlight on for 10 seconds, then turns off and enters low power mode (Factory default). |
| B-2 | Backlight on for 20 seconds, then turns off and enters low power mode. |
| B-3 | Backlight on for 30 seconds, then turns off and enters low power mode. |
| B-4 | Backlight on for 40 seconds, then turns off and enters low power mode. |
| B-5 | Backlight on for 50 seconds, then turns off and enters low power mode. |
| B-6 | Backlight on for 60 seconds, then turns off and enters low power mode. |
Advanced Settings: Voltage Calibration
Important: This product has been calibrated before leaving the factory. Please use this function with caution, as incorrect calibration can lead to inaccurate readings.
- From the main screen, press and hold the button for 2 seconds to enter the settings page.
- Short press the button to switch to the CAL page (voltage calibration).
- To begin calibration, press and hold the button for 2 seconds until "CAL" flashes.
- Calibrate using an external high-precision 30.00V voltage source.
- Calibration Success: The battery indicator will show a green light at 100%.
- Calibration Failure: The battery indicator will show a red light at 20%. This is usually caused by an inaccurate external calibration voltage.
- If calibration fails, try calibrating multiple times or replace the external high-precision calibration power supply.
- Once calibration is successful, press and hold the button for 2 seconds to return to the main screen, or short press the button to enter the next settings page.
Troubleshooting
- Inaccurate Readings: If readings are inaccurate, ensure the correct battery type and voltage parameters are set. Consider performing a voltage calibration if necessary, using a precise 30.00V reference.
- Low Voltage Alarm: When the battery level is equal to or lower than 10%, the red battery indicator will flash. This is a normal function to alert you to low battery status.
- Display Not Turning On/Off: Ensure the button is pressed correctly (short press for toggle, long press for settings). Check power connections.
- Power-Off Memory: The device has a power-off memory function, so settings should be retained even after power loss. If settings are not retained, contact support.
Maintenance
The 4615N Battery Power Meter requires minimal maintenance. Keep the device clean and free from dust and moisture. Avoid exposing it to extreme temperatures or direct sunlight for prolonged periods. Do not attempt to disassemble the device, as this may void any potential warranty and cause damage.
User Tips
Based on user feedback, this product is generally well-regarded for its appearance and quality. No specific operational tips were highlighted in the available reviews.
Specifications
| Feature | Description |
|---|---|
| Model Number | 4615N (Battery Charge Indicator Board) |
| Brand Name | Diymore |
| Voltage Measurement Range | DC 7-55V (Red display: DC 7-40V) |
| Operating Current | ≤ 20mA |
| Display Method | LED screen (Digital Only) |
| Display Colors | Red, Green, Blue, White (optional) |
| Power-Off Memory Function | Yes |
| Low Voltage Alarm | Red battery indicator flashes when level ≤ 10% |
| Battery Included | No |
| Data Record | No |
| High-Concerned Chemical | None |
| Certification | NONE |
| Origin | Mainland China |
| DIY Supplies | Electrical |
| Accuracy Class | 0.01 |
| Power Supply / Source | DC |
Battery Type Compatibility
- Ternary Lithium Battery (L): L03 to L12 series (Default L03S on first power-on)
- Lithium Iron Phosphate Battery (F): F03 to F14 series
- Lead-Acid Battery (P): 12V, 24V, 36V, 48V
Product Dimensions


Product size: 40 x 15 x 3mm (earless model)
Warranty and Support