1. Product Overview
The ANENJI ANJ-3KW-24V-WIFI is a multi-functional hybrid inverter/charger, combining the functions of an inverter, solar charger, and battery charger to offer uninterruptible power support in a portable size. Its comprehensive LCD display allows user-configurable and easy-accessible button operations such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Key Features:
- Rated Power: 3000W (3KW)
- Battery Voltage: 24V
- Output Voltage: 110/120VAC
- Max. Solar Charge Current: 100A MPPT
- Max. PV Array Power: 4000W
- PV Array MPPT Voltage Range: 60VDC~450VDC
- Max. PV Array Open Circuit Voltage: 500VDC
- Output Type: Pure Sine Wave
- Built-in: WiFi for remote monitoring
- Power Factor: 1.0
- Compatibility: Compatible with LiFePO4 battery via RS485 communication
- Environment: Detachable dust cover for harsh environments
- Functionality: Capable of working without a battery

Figure 1.1: ANENJI 3KW Hybrid Solar Inverter with key features.

Figure 1.2: Detailed product characteristics.

Figure 1.3: Examples of appliances powered by the pure sine wave output.
Inverter Components:
The inverter features a comprehensive layout of ports and indicators for easy setup and monitoring.

Figure 1.4: Front and rear view of the inverter with labeled components.
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Battery input
- RS485 communication port
- Grounding
- WiFi antenna port
- AC input
- AC output
- PV input
- Power on/off switch
- Dry contact port
2. Setup and Installation
2.1 Unpacking and Inspection
Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain:
- Inverter Unit x 1
- User Manual x 1
- WiFi Antenna x 1
2.2 Preparation
Before connecting any wiring, remove the bottom port cover by unscrewing the two screws located at the bottom of the unit.
2.3 Mounting the Unit
Observe the following guidelines when selecting a mounting location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface (concrete or other non-combustible surface only).
- Install at eye level for easy reading of the LCD display.
- Ambient temperature should be between $0^{\circ}C$ and $55^{\circ}C$.
- Mount vertically on the wall.
- Ensure adequate clearance (at least 20cm on sides, 50cm top/bottom) for heat dissipation and wiring access.
2.4 Battery Connection
CAUTION: For safety, install a separate DC over-current protector or disconnect device between the battery and inverter.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cables and terminals to reduce injury risk.
Recommended Battery Cable and Terminal Size:
| Model | Max. Amperage | Battery Capacity | Wire Size | Cable $mm^2$ | Terminal Torque |
|---|---|---|---|---|---|
| 3KVA | 137A | 200AH | 2AWG | 35 | 4~6 Nm |
Connection Steps:
- Prepare battery cables and terminals according to specifications.
- Connect all battery packs as required.
- Insert battery cables into the inverter's battery connector, ensuring correct polarity (positive to positive, negative to negative), and tighten bolts to 4~6 Nm.
2.5 AC Input/Output Connection
CAUTION: Install a separate AC breaker between the inverter and AC input source. Do not mis-connect input and output connectors.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cables.
Suggested Cable Requirement for AC Wires:
| Model | Gauge | Torque Value |
|---|---|---|
| 3KVA | 10AWG | 1.4~1.6 Nm |
Connection Steps:
- Open DC protector/disconnector.
- Remove 10mm insulation from conductors.
- Insert AC input wires (L, N, PE) according to polarities on the terminal block and tighten screws.
- Insert AC output wires (L, N, PE) according to polarities and tighten screws.
- Ensure all wires are securely connected.
2.6 PV Connection
CAUTION: Install a DC circuit breaker between the inverter and PV modules.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cables.
PV Module Selection Guidelines:
- PV array open circuit voltage (Voc) must not exceed 500VDC.
- PV array Voc must be higher than the minimum battery voltage.

Figure 2.1: PV module connection diagram and key parameters for selection.
PV Connection Steps:
- Remove 6mm insulation from positive and negative conductors.
- Connect positive PV cable to positive PV input connector, and negative PV cable to negative PV input connector.
- Ensure wires are securely connected.
2.7 System Connection Diagram

Figure 2.2: Comprehensive system connection diagram including solar, generator, utility, battery, and home appliances.
2.8 Final Assembly
After all wiring is complete, reinstall the bottom port cover by screwing it back into place.
2.9 Wiring Guide Video
For a visual guide on wiring the inverter, please watch the official video:
Video 2.1: ANENJI Solar Inverter Wiring Guide.
3. Operating Instructions
3.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the side of the unit) to power on the inverter.
3.2 Operation and Display Panel
The front panel features an LCD display, three LED indicators, and four function keys to show operating status and power information.
LED Indicators:
- AC/INV (Green): Solid On (Output from utility), Flashing (Output from battery/PV).
- CHG (Green): Solid On (Battery fully charged), Flashing (Battery charging).
- FAULT (Red): Solid On (Fault occurs), Flashing (Warning condition).
Function Keys:
- ESC: Exit setting mode.
- UP: Go to previous selection.
- DOWN: Go to next selection.
- ENTER: Confirm selection or enter setting mode.
3.3 LCD Setting
Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN to select programs and ENTER to confirm, or ESC to exit.
Key configurable settings include:
- Output Source Priority (Program 01): Utility first, Solar first, SBU priority (Solar-Battery-Utility), SUB priority (Solar-Utility-Battery), SUF priority (Solar-Utility-Feed-in).
- Maximum Charging Current (Program 02): Configure total charging current for solar and utility chargers (e.g., 60A default).
- AC Input Voltage Range (Program 03): Select for Appliances (70-140VAC), UPS (95-140VAC), or Generator (95-140VAC).
- Battery Type (Program 05): AGM, Flooded, User-Defined, Lithium (various types).
- Output Voltage (Program 08): 110V, 115V, 120V.
- Output Frequency (Program 09): 50Hz, 60Hz.
- Auto Bypass (Program 10): Manual or Auto.
- Battery Equalization (Program 33): Enable/Disable.
3.4 Dry Contact Signal
A dry contact (3A/250VAC) is available on the rear panel to deliver a signal to an external device when battery voltage reaches a warning level. This can indicate power status (on/off) and source (utility/battery/solar).
3.5 Battery Equalization
The equalization function helps reverse negative chemical effects like stratification and removes sulfate crystals, extending battery life. It can be applied by setting an equalization interval (Program 37) or activating it immediately (Program 39). During equalization, the inverter charges the battery to a higher voltage for a set period.
3.6 Setting for Lithium Battery
If using a lithium battery, ensure it is compatible. Connect the battery's RS485 port to the inverter's BMS (RS485) communication port. Configure specific LCD settings (Program 05 for battery type, and adjust charging voltage/current, discharge cut-off voltage as per battery BMS specifications).
4. Maintenance
To ensure optimal performance and longevity of your ANENJI Hybrid Solar Inverter, regular maintenance is recommended:
- Keep Vents Clear: Ensure that the inverter's ventilation openings are free from dust and obstructions to allow for proper airflow and heat dissipation.
- Dust Cover: Utilize the detachable dust cover, especially in harsh environments, to protect internal components from excessive dust accumulation.
- Regular Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.
- Clean Exterior: Keep the exterior of the inverter clean with a dry, soft cloth. Do not use liquid cleaners.
5. Troubleshooting
5.1 Fault Reference Code
The inverter's LCD display will show specific fault codes if an issue occurs. Refer to the table below for common fault codes and their descriptions:
| Fault Code | Fault Event |
|---|---|
| 01 | Over temperature of inverter module |
| 02 | Over temperature of DCDC module |
| 03 | Battery voltage is too high |
| 04 | Over temperature of PV module |
| 05 | Output short circuited. |
| 06 | Output voltage is too high. |
| 07 | Overload time out |
| 08 | Bus voltage is too high |
| 09 | Bus soft start failed |
| 10 | PV over current |
| 11 | PV over voltage |
| 12 | DCDC over current |
| 13 | Over current or surge |
| 14 | Bus voltage is too low |
| 15 | Inverter failed (Self-checking) |
| 18 | Op current offset is too high |
| 19 | Inverter current offset is too high |
| 20 | DC/DC current offset is too high |
| 21 | PV current offset is too high |
| 22 | Output voltage is too low |
| 23 | Inverter negative power |
5.2 Warning Indicator
The inverter provides audible alarms and flashing icons for various warning conditions:
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 02 | Temperature is too High | Beep three times every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 14 | Fan blocked | None |
| 15 | PV energy is low | Beep twice every 3 seconds |
| 19 | Lithium Battery communication is failed | Beep once every 0.5 second |
| 21 | Lithium Battery over current | None |
| E9 | Battery equalization | None |
| bP | Battery is not connected | None |
5.3 General Troubleshooting
If the inverter is not functioning as expected, consult the following table for common issues and solutions:
| Problem | Explanation / Possible Cause | What to do |
|---|---|---|
| Unit shuts down automatically during startup | Battery voltage is too low | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | 1. Battery voltage is far too low. 2. Battery polarity is connected reversed. | 1. Check if batteries and wiring are connected well. 2. Re-charge battery. 3. Replace battery. |
| Mains exist but unit works in battery mode. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin/long. 2. Check if generator works well or if input voltage range setting is correct. |
| When unit is turned on, internal relay switches on/off repeatedly. | Battery is disconnected. | Check if battery wires are connected well. |
| Buzzer beeps continuously and red LED is on. | Overload error (Fault code 07) | Reduce connected load. |
| Output short circuited (Fault code 05) | Check wiring, remove abnormal load. | |
| Internal temperature over $100^{\circ}C$ (Fault code 02) | Check if airflow is blocked or ambient temperature is too high. | |
| Battery is over-charged (Fault code 03) | Return to repair center. | |
| Output abnormal (Fault code 06/22) | 1. Reduce connected load. 2. Return to repair center. | |
| Internal components failed (Fault code 08/09/15) | Return to repair center. | |
| Over current or surge (Fault code 13) | Restart unit, if error persists, return to repair center. |
6. Specifications
6.1 Line Mode Specifications
| Parameter | Value |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 120Vac |
| Low Loss Voltage | 95Vac±7V (UPS); 70Vac±7V (Appliances) |
| High Loss Voltage | 140Vac±7V |
| Max AC Input Voltage | 150Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
6.2 Inverter Mode Specifications
| Parameter | Value |
|---|---|
| Rated Output Power | 3.0KVA/3.0KW |
| Output Voltage Waveform | Pure Sine Wave |
| Output Voltage Regulation | 120Vac±5% |
| Output Frequency | 50Hz or 60Hz |
| Peak Efficiency | 94% |
| Surge Capacity | 2* rated power for 5 seconds |
| Nominal DC Input Voltage | 24Vdc |
| No Load Power Consumption | <55W |
6.3 Charge Mode Specifications
| Parameter | Value |
|---|---|
| Max Charging Current (PV+AC) | 100Amp |
| Max Charging Current (AC) | 60Amp |
| Bulk Charging Voltage (Flooded) | 29.2Vdc |
| Bulk Charging Voltage (AGM / Gel) | 28.2Vdc |
| Floating Charging Voltage | 27Vdc |
| Overcharge Protection | 32Vdc |
| Solar Input Rated Power | 4000W |
| Solar Input Max. PV Array Open Circuit Voltage | 500Vdc |
| Solar Input PV Array MPPT Voltage Range | 60Vdc~500Vdc |
| Solar Input Max. Input Current | 27A |
| Solar Input Max. Charging Current(PV) | 100A |
6.4 General Specifications
| Parameter | Value |
|---|---|
| Operating Temperature Range | -10°C to 55°C |
| Storage temperature | -15°C~60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Dimension (D*W*H), mm | 350x312x110 |
| Net Weight, kg | 6.9 |
7. Wi-Fi Setup Guide
The ANENJI ANJ-3KW-24V-WIFI inverter includes built-in Wi-Fi for remote monitoring. Follow these steps to set up the Wi-Fi connection:
7.1 Install Wireless Antenna
Locate the Wi-Fi antenna port on the inverter (refer to Figure 1.4, component 9) and securely screw in the provided wireless antenna.
7.2 Download the SmartESS App
- Scan the QR code provided in the app's quick guide or search for