ANENJI ANJ-3KW-24V-WIFI

Contents

ANENJI ANJ-3KW-24V-WIFI Hybrid Solar Inverter/Charger User Manual

Model: ANJ-3KW-24V-WIFI

1. Product Overview

The ANENJI ANJ-3KW-24V-WIFI is a multi-functional hybrid inverter/charger, combining the functions of an inverter, solar charger, and battery charger to offer uninterruptible power support in a portable size. Its comprehensive LCD display allows user-configurable and easy-accessible button operations such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

Key Features:

  • Rated Power: 3000W (3KW)
  • Battery Voltage: 24V
  • Output Voltage: 110/120VAC
  • Max. Solar Charge Current: 100A MPPT
  • Max. PV Array Power: 4000W
  • PV Array MPPT Voltage Range: 60VDC~450VDC
  • Max. PV Array Open Circuit Voltage: 500VDC
  • Output Type: Pure Sine Wave
  • Built-in: WiFi for remote monitoring
  • Power Factor: 1.0
  • Compatibility: Compatible with LiFePO4 battery via RS485 communication
  • Environment: Detachable dust cover for harsh environments
  • Functionality: Capable of working without a battery
ANENJI 3KW Hybrid Solar Inverter with key features highlighted

Figure 1.1: ANENJI 3KW Hybrid Solar Inverter with key features.

Product Characteristics of ANENJI Solar Inverter

Figure 1.2: Detailed product characteristics.

Pure Sine Wave output applications

Figure 1.3: Examples of appliances powered by the pure sine wave output.

Inverter Components:

The inverter features a comprehensive layout of ports and indicators for easy setup and monitoring.

Diagram of ANENJI Inverter Ports and Display

Figure 1.4: Front and rear view of the inverter with labeled components.

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Battery input
  7. RS485 communication port
  8. Grounding
  9. WiFi antenna port
  10. AC input
  11. AC output
  12. PV input
  13. Power on/off switch
  14. Dry contact port

2. Setup and Installation

2.1 Unpacking and Inspection

Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain:

  • Inverter Unit x 1
  • User Manual x 1
  • WiFi Antenna x 1

2.2 Preparation

Before connecting any wiring, remove the bottom port cover by unscrewing the two screws located at the bottom of the unit.

2.3 Mounting the Unit

Observe the following guidelines when selecting a mounting location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface (concrete or other non-combustible surface only).
  • Install at eye level for easy reading of the LCD display.
  • Ambient temperature should be between $0^{\circ}C$ and $55^{\circ}C$.
  • Mount vertically on the wall.
  • Ensure adequate clearance (at least 20cm on sides, 50cm top/bottom) for heat dissipation and wiring access.

2.4 Battery Connection

CAUTION: For safety, install a separate DC over-current protector or disconnect device between the battery and inverter.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cables and terminals to reduce injury risk.

Recommended Battery Cable and Terminal Size:

ModelMax. AmperageBattery CapacityWire SizeCable $mm^2$Terminal Torque
3KVA137A200AH2AWG354~6 Nm

Connection Steps:

  1. Prepare battery cables and terminals according to specifications.
  2. Connect all battery packs as required.
  3. Insert battery cables into the inverter's battery connector, ensuring correct polarity (positive to positive, negative to negative), and tighten bolts to 4~6 Nm.

2.5 AC Input/Output Connection

CAUTION: Install a separate AC breaker between the inverter and AC input source. Do not mis-connect input and output connectors.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cables.

Suggested Cable Requirement for AC Wires:

ModelGaugeTorque Value
3KVA10AWG1.4~1.6 Nm

Connection Steps:

  1. Open DC protector/disconnector.
  2. Remove 10mm insulation from conductors.
  3. Insert AC input wires (L, N, PE) according to polarities on the terminal block and tighten screws.
  4. Insert AC output wires (L, N, PE) according to polarities and tighten screws.
  5. Ensure all wires are securely connected.

2.6 PV Connection

CAUTION: Install a DC circuit breaker between the inverter and PV modules.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cables.

PV Module Selection Guidelines:

  • PV array open circuit voltage (Voc) must not exceed 500VDC.
  • PV array Voc must be higher than the minimum battery voltage.
PV Module Selection Diagram and Table

Figure 2.1: PV module connection diagram and key parameters for selection.

PV Connection Steps:

  1. Remove 6mm insulation from positive and negative conductors.
  2. Connect positive PV cable to positive PV input connector, and negative PV cable to negative PV input connector.
  3. Ensure wires are securely connected.

2.7 System Connection Diagram

Overall System Connection Diagram

Figure 2.2: Comprehensive system connection diagram including solar, generator, utility, battery, and home appliances.

2.8 Final Assembly

After all wiring is complete, reinstall the bottom port cover by screwing it back into place.

2.9 Wiring Guide Video

For a visual guide on wiring the inverter, please watch the official video:

Video 2.1: ANENJI Solar Inverter Wiring Guide.

3. Operating Instructions

3.1 Power ON/OFF

Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the side of the unit) to power on the inverter.

3.2 Operation and Display Panel

The front panel features an LCD display, three LED indicators, and four function keys to show operating status and power information.

LED Indicators:

  • AC/INV (Green): Solid On (Output from utility), Flashing (Output from battery/PV).
  • CHG (Green): Solid On (Battery fully charged), Flashing (Battery charging).
  • FAULT (Red): Solid On (Fault occurs), Flashing (Warning condition).

Function Keys:

  • ESC: Exit setting mode.
  • UP: Go to previous selection.
  • DOWN: Go to next selection.
  • ENTER: Confirm selection or enter setting mode.

3.3 LCD Setting

Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN to select programs and ENTER to confirm, or ESC to exit.

Key configurable settings include:

  • Output Source Priority (Program 01): Utility first, Solar first, SBU priority (Solar-Battery-Utility), SUB priority (Solar-Utility-Battery), SUF priority (Solar-Utility-Feed-in).
  • Maximum Charging Current (Program 02): Configure total charging current for solar and utility chargers (e.g., 60A default).
  • AC Input Voltage Range (Program 03): Select for Appliances (70-140VAC), UPS (95-140VAC), or Generator (95-140VAC).
  • Battery Type (Program 05): AGM, Flooded, User-Defined, Lithium (various types).
  • Output Voltage (Program 08): 110V, 115V, 120V.
  • Output Frequency (Program 09): 50Hz, 60Hz.
  • Auto Bypass (Program 10): Manual or Auto.
  • Battery Equalization (Program 33): Enable/Disable.

3.4 Dry Contact Signal

A dry contact (3A/250VAC) is available on the rear panel to deliver a signal to an external device when battery voltage reaches a warning level. This can indicate power status (on/off) and source (utility/battery/solar).

3.5 Battery Equalization

The equalization function helps reverse negative chemical effects like stratification and removes sulfate crystals, extending battery life. It can be applied by setting an equalization interval (Program 37) or activating it immediately (Program 39). During equalization, the inverter charges the battery to a higher voltage for a set period.

3.6 Setting for Lithium Battery

If using a lithium battery, ensure it is compatible. Connect the battery's RS485 port to the inverter's BMS (RS485) communication port. Configure specific LCD settings (Program 05 for battery type, and adjust charging voltage/current, discharge cut-off voltage as per battery BMS specifications).

4. Maintenance

To ensure optimal performance and longevity of your ANENJI Hybrid Solar Inverter, regular maintenance is recommended:

  • Keep Vents Clear: Ensure that the inverter's ventilation openings are free from dust and obstructions to allow for proper airflow and heat dissipation.
  • Dust Cover: Utilize the detachable dust cover, especially in harsh environments, to protect internal components from excessive dust accumulation.
  • Regular Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.
  • Clean Exterior: Keep the exterior of the inverter clean with a dry, soft cloth. Do not use liquid cleaners.

5. Troubleshooting

5.1 Fault Reference Code

The inverter's LCD display will show specific fault codes if an issue occurs. Refer to the table below for common fault codes and their descriptions:

Fault CodeFault Event
01Over temperature of inverter module
02Over temperature of DCDC module
03Battery voltage is too high
04Over temperature of PV module
05Output short circuited.
06Output voltage is too high.
07Overload time out
08Bus voltage is too high
09Bus soft start failed
10PV over current
11PV over voltage
12DCDC over current
13Over current or surge
14Bus voltage is too low
15Inverter failed (Self-checking)
18Op current offset is too high
19Inverter current offset is too high
20DC/DC current offset is too high
21PV current offset is too high
22Output voltage is too low
23Inverter negative power

5.2 Warning Indicator

The inverter provides audible alarms and flashing icons for various warning conditions:

Warning CodeWarning EventAudible Alarm
02Temperature is too HighBeep three times every second
04Low batteryBeep once every second
07OverloadBeep once every 0.5 second
10Output power deratingBeep twice every 3 seconds
14Fan blockedNone
15PV energy is lowBeep twice every 3 seconds
19Lithium Battery communication is failedBeep once every 0.5 second
21Lithium Battery over currentNone
E9Battery equalizationNone
bPBattery is not connectedNone

5.3 General Troubleshooting

If the inverter is not functioning as expected, consult the following table for common issues and solutions:

ProblemExplanation / Possible CauseWhat to do
Unit shuts down automatically during startupBattery voltage is too low1. Re-charge battery. 2. Replace battery.
No response after power on.1. Battery voltage is far too low. 2. Battery polarity is connected reversed.1. Check if batteries and wiring are connected well. 2. Re-charge battery. 3. Replace battery.
Mains exist but unit works in battery mode.Insufficient quality of AC power. (Shore or Generator)1. Check if AC wires are too thin/long. 2. Check if generator works well or if input voltage range setting is correct.
When unit is turned on, internal relay switches on/off repeatedly.Battery is disconnected.Check if battery wires are connected well.
Buzzer beeps continuously and red LED is on.Overload error (Fault code 07)Reduce connected load.
Output short circuited (Fault code 05)Check wiring, remove abnormal load.
Internal temperature over $100^{\circ}C$ (Fault code 02)Check if airflow is blocked or ambient temperature is too high.
Battery is over-charged (Fault code 03)Return to repair center.
Output abnormal (Fault code 06/22)1. Reduce connected load. 2. Return to repair center.
Internal components failed (Fault code 08/09/15)Return to repair center.
Over current or surge (Fault code 13)Restart unit, if error persists, return to repair center.

6. Specifications

6.1 Line Mode Specifications

ParameterValue
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage120Vac
Low Loss Voltage95Vac±7V (UPS); 70Vac±7V (Appliances)
High Loss Voltage140Vac±7V
Max AC Input Voltage150Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

6.2 Inverter Mode Specifications

ParameterValue
Rated Output Power3.0KVA/3.0KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation120Vac±5%
Output Frequency50Hz or 60Hz
Peak Efficiency94%
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage24Vdc
No Load Power Consumption<55W

6.3 Charge Mode Specifications

ParameterValue
Max Charging Current (PV+AC)100Amp
Max Charging Current (AC)60Amp
Bulk Charging Voltage (Flooded)29.2Vdc
Bulk Charging Voltage (AGM / Gel)28.2Vdc
Floating Charging Voltage27Vdc
Overcharge Protection32Vdc
Solar Input Rated Power4000W
Solar Input Max. PV Array Open Circuit Voltage500Vdc
Solar Input PV Array MPPT Voltage Range60Vdc~500Vdc
Solar Input Max. Input Current27A
Solar Input Max. Charging Current(PV)100A

6.4 General Specifications

ParameterValue
Operating Temperature Range-10°C to 55°C
Storage temperature-15°C~60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm350x312x110
Net Weight, kg6.9

7. Wi-Fi Setup Guide

The ANENJI ANJ-3KW-24V-WIFI inverter includes built-in Wi-Fi for remote monitoring. Follow these steps to set up the Wi-Fi connection:

7.1 Install Wireless Antenna

Locate the Wi-Fi antenna port on the inverter (refer to Figure 1.4, component 9) and securely screw in the provided wireless antenna.

7.2 Download the SmartESS App

  1. Scan the QR code provided in the app's quick guide or search for

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.