1. Introduction
1.1 Purpose and Scope
This manual provides detailed instructions for the assembly, installation, operation, and troubleshooting of your SUMRY ECO Hybrid Solar Inverter. Please read this manual carefully before installation and operation, and keep it for future reference. It includes safety and installation guidelines, as well as information on necessary tools and wiring.
1.2 Key Features
The SUMRY ECO Hybrid Solar Inverter is a multi-function inverter/charger that combines the capabilities of an inverter, solar charger, and battery charger to provide uninterruptible power support. Its compact size and comprehensive LCD display allow for user-configurable and easily accessible button operations.
- Pure sine wave output for sensitive electronics.
- Configurable input voltage range for home appliances and personal computers.
- Configurable battery charging current based on application needs.
- Configurable AC/Solar Charger priority.
- Compatibility with mains voltage or generator power.
- Automatic restart upon AC recovery.
- Protection against overload, over-temperature, and short circuits.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Inverter running without battery.
- High PV input voltage range (60-500VDC).
- Built-in 120A MPPT Solar charge: max 6200W (for 3.6KW/4.2KW) max 6500W (for 6.2KW).
- Built-in 80A MPPT Solar charge: max 6500W (for 3.6KW/48V).
- Dual communication ports for Battery communication and Wifi communication.
- Dual output.
1.3 Basic System Architecture
This inverter/charger is designed to power various appliances in home or office environments, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners. A complete system typically includes the inverter/charger, a generator or utility power source, PV modules, and external battery packs.

2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION - Only qualified personnel can install this device with a battery.
- NEVER charge a frozen battery.
- For optimum operation, follow the required specifications to select appropriate cable sizes.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
- Strictly follow the installation procedure when disconnecting AC or DC terminals. Refer to the INSTALLATION section for details.
- One 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors persist after following the troubleshooting table, send the inverter/charger back to a local dealer or service center for maintenance.
3. Setup and Installation
3.1 Unpacking and Inspection
Upon receiving your inverter, inspect the unit for any damage. Ensure the package contains the unit and the user manual. If any items are missing or damaged, contact your supplier immediately.
3.2 Preparation and Mounting
Before connecting any cables, remove the screws located under the machine and detach the bottom cover plate. When selecting a mounting location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install the inverter at eye level for easy LCD display readability.
- Allow approximately 20 cm clearance to the sides and 50 cm above and below the unit for proper air circulation and heat dissipation.
- Ensure the ambient temperature is between 0°C and 55°C for optimal operation.
- The recommended installation position is vertically adhered to a wall.
- Ensure sufficient space around the machine for adequate heat dissipation and wiring access.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Secure the unit by screwing two M6 screws into the mounting surface.

3.3 Battery Connection
CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Always use appropriate cable sizes as specified below.
WARNING: All wiring must be performed by qualified personnel.
- Remove 18 mm of insulation from positive and negative conductors.
- Use bootlace ferrules on the wire ends with a proper crimping tool.
- Connect all battery packs as shown in the diagram (refer to the PDF manual for detailed diagrams for 3.6KW/4.2KW and 6.2KW models).
- Insert the battery wires flatly into the battery connectors and tighten the bolts to a torque of 2 Nm in a clockwise direction. Ensure correct polarity (+ to + and - to -) at both the battery and the inverter/charger.
WARNING: Shock Hazard - Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) is connected to negative (-).
| Model | Wire Size | Cable (mm²) | Torque Value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 2AWG | 25 | 2 Nm |
3.4 AC Input/Output Connection
CAUTION!! Install a separate AC breaker between the inverter and the AC input power source. The recommended AC breaker is 32A for 3.6KW/4.2KW and 50A for 6.2KW. Do NOT mis-connect input and output terminals.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable sizes as specified below.
- Before making AC input/output connections, open the DC protector or disconnector.
- Remove 10mm of insulation for six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities (L=LINE, N=Neutral) and tighten terminal screws.
- WARNING: Ensure AC power source is disconnected before hardwiring.
- Insert AC output wires according to polarities (L=LINE, N=Neutral) and tighten terminal screws.
- Ensure all wires are securely connected.
CAUTION: Appliances like air conditioners require 2-3 minutes to restart. If power fluctuates, the inverter may trigger an overload fault. Check appliance manufacturer for time-delay function.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 3.6KW/4.2KW | 12 AWG | 4 | 1.2 Nm |
| 6.2KW | 10 AWG | 6 | 1.2 Nm |
3.5 PV Connection
CAUTION: Install a DC circuit breaker between the inverter and PV modules.
WARNING: Use appropriate cable sizes for PV module connection.
- Remove 10mm of insulation from positive and negative conductors.
- Use bootlace ferrules on the wire ends with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Connect positive (+) to positive (+) and negative (-) to negative (-).
| Model | Wire Size | Cable (mm²) | Torque Value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
| INVERTER MODEL | 3.6KW/4.2KW | 6.2KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | |
3.6 Final Assembly
After connecting all wirings, replace the bottom cover by screwing the two screws back into place.
3.7 Communication Connection
The inverter supports Wi-Fi and GPRS cloud communication for monitoring. Use the supplied communication cable to connect to the inverter and the respective module (Wi-Fi or GPRS). Download the APP and follow the quick installation guidelines to set up the network and register the device. The inverter status can then be monitored via the mobile phone APP or a computer webpage.
For lithium battery communication, connect an RJ45 cable between the inverter's BMS communication port and the battery's RS485 communication port. Ensure the PIN definitions correspond (refer to the PDF manual for the PIN definition table). If using a lithium battery, set the battery type to "LIB-485" in program 05 and select the matching battery protocol in program 43.
4. Operating Instructions
4.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the side of the case) to power on the unit.
4.2 Operation and Display Panel
The inverter features an operation and display panel on the front, including three indicators, four function keys, and an LCD display. This panel provides real-time operating status and input/output power information.

4.3 LCD Display Icons
The LCD display provides various icons to indicate the inverter's status and operational mode. These include icons for AC input, PV input, configuration programs, fault/warning indicators, output information (voltage, frequency, load), battery information, and overload status. Refer to the PDF manual (section 5.3) for a complete list and description of all LCD display icons.
4.4 LCD Setting
To enter setting mode, press and hold the ENTER button for 3 seconds. Use the UP or DOWN buttons to select setting programs, and ENTER to confirm or ESC to exit. Key settings include:
- Program 00: Exit setting mode (One-button restore setting options: 00 GOE, 00 GOH).
- Program 01: Output source priority (Utility first, Solar first, SBU priority, MKS priority).
- Program 02: Maximum charging current.
- Program 03: AC input voltage range.
- Program 05: Battery type (AGM, Flooded, User-Defined, LIB-485).
- Program 06: Auto restart when overload occurs.
- Program 07: Auto restart when over temperature occurs.
- Program 09: Output frequency.
- Program 10: Output voltage.
- Program 11: Maximum utility charging current.
- Program 12: Setting voltage point back to utility source when selecting "SBU priority" or "Solar first" in program 01.
- Program 13: Setting voltage point back to battery mode when selecting "SBU priority" or "Solar first" in program 01.
- Program 16: Charger source priority.
- Program 18: Alarm control.
- Program 19: Auto return to default display screen.
- Program 20: Backlight control.
- Program 22: Beeps while primary source is interrupted.
- Program 23: Overload bypass.
- Program 25: Record Fault code.
- Program 26: Bulk charging voltage (C.V voltage).
- Program 27: Floating charging voltage.
- Program 29: Low DC cut-off voltage.
- Program 30: Battery equalization.
- Program 31: Battery equalization voltage.
- Program 33: Battery equalized time.
- Program 34: Battery equalized timeout.
- Program 35: Equalization interval.
- Program 36: Equalization activated immediately.
- Program 37: GRID-tie operation.
- Program 38: GRID-tie current.
- Program 39: LED pattern light.
- Program 41: Dual output.
- Program 42: Enter the dual output functional voltage point.
- Program 43: Lithium battery protocol.
- Program 44: Delayed grid access.
- Program 45: Maximum Second Load.
4.5 Operating Mode Description
The inverter operates in various modes, including Standby, Line Mode, Grid-Tie Operation, and Battery Mode. Each mode has specific behaviors regarding power flow and charging. Refer to the PDF manual (section 5.6) for detailed descriptions of each operating mode and their corresponding LCD displays.
4.6 Battery Equalization
The equalization function helps reverse the buildup of negative chemical effects like stratification and removes sulfate crystals from battery plates, optimizing battery performance and longevity. To apply equalization, enable the function in monitoring LCD setting program 30. You can then set the equalization interval in program 35 or activate it immediately in program 36. The controller will enter the Equalize stage when the set interval is reached or immediately if activated.
4.7 Mains and Lithium Battery Activation Function
- After 90 seconds of mains power connection, the machine connects to the mains and starts working.
- If the inverter is in lithium battery mode (item 05 is Llb or Llb-485) and the battery is not connected, the mains activation function is automatically enabled upon mains connection.
5. Maintenance
5.1 Anti-Dust Kit Clearance and Maintenance
The inverter comes with a pre-installed anti-dust kit to protect internal components and maintain optimal temperature. This kit helps increase product reliability in harsh environments.
- Loosen the screw on the top of the inverter in a counterclockwise direction.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case.
- After cleaning, re-assemble the dust-kit back to the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
6. Troubleshooting
This section provides guidance for common issues. For persistent problems, contact a qualified service technician.
6.1 Fault Reference Codes
The inverter's LCD display will show specific fault codes if an error occurs. Refer to the PDF manual (section 5.9) for a complete list of fault codes, their events, and corresponding icon displays.
6.2 Warning Indicators
The inverter provides warning indicators for various conditions. These warnings are accompanied by audible alarms and specific icon flashes on the LCD. Refer to the PDF manual (section 5.10) for a complete list of warning codes, events, audible alarms, and icon displays.
6.3 Troubleshooting Table
If you encounter any issues, consult the table below for possible causes and solutions.
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but the unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS Appliance) |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. The inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. | |
| Output short circuited. | Check if wiring is connected well and remove abnormal load. | ||
| Fault code 05 | Temperature of internal converter component is over 120°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Fault code 02 | Internal temperature of inverter component is over 100°C. | Return to repair center. | |
| Buzzer beeps continuously and red LED is on. | Fault code 03 | Battery is over-charged. The battery voltage is too high. | Check if spec and quantity of batteries are meet requirements. |
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center | |
| Fault code 08/09/53/57 | Internal components failed. | Return to repair center. | |
| Fault code 51 | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 52 | Bus voltage is too low. | ||
| Fault code 55 | Output voltage is unbalanced. |
7. Specifications
The following tables detail the technical specifications for the SUMRY ECO Hybrid Solar Inverter.
7.1 General Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Safety Certification | CE | ||
| Operating Temperature Range | -10°C to 50°C | ||
| Storage temperature | -15°C~60°C | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||
| Dimension (D*W*H), mm | 358×442×116 | ||
| Net Weight, kg | 8.0 | 8.0 | 8.9 |
| Output Current | 10A | ||
| Is Smart Device | Yes | ||
| Output Type | SINGLE | ||
| Communication Interface | RS232 | ||
| Support Battery type | lithium battery, LiFePo4; Lead acid battery | ||
| Control type | MPPT | ||
| Continuous Power | 3000W | ||
| AC output voltage | 110/220V-50Hz/60Hz | ||
| Waveform | Pure Sine Wave | ||
| AC input | 230VAC | ||
| Battery voltage | 24VDC/48VDC | ||
| Max charge current for battery | 60A | ||
| Max charge current for solar | 80A | ||
7.2 Line Mode Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | ||
| Nominal Input Voltage | 230Vac | ||
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | ||
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliance) | ||
| High Loss Voltage | 280Vac±7V | ||
| High Loss Return Voltage | 270Vac±7V | ||
| Max AC Input Voltage | 300Vac | ||
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | ||
| Low Loss Frequency | 40±1Hz | ||
| Low Loss Return Frequency | 42±1Hz | ||
| High Loss Frequency | 65±1Hz | ||
| High Loss Return Frequency | 63±1Hz | ||
| Output Short Circuit Protection | Circuit Breaker | ||
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | ||
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | ||
7.3 Inverter Mode Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Rated Output Power | 3.6KW | 4.2KW | 6.2KW |
| Output Voltage Waveform | Pure Sine Wave | ||
| Output Voltage Regulation | 230Vac±5% | ||
| Output Frequency | 50Hz | ||
| Peak Efficiency | 93% | ||
| Overload Protection | 3s@≥150% load; 5s@101%~150% load | ||
| Surge Capacity | 2* rated power for 5 seconds | ||
| Nominal DC Input Voltage | 24Vdc | 48Vdc | |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc | |
| Low DC Warning Voltage @ load < 50% | 22.0Vdc | 44.0Vdc | |
| Low DC Warning Voltage @ load ≥ 50% | 21.0Vdc | 42.0Vdc | |
| Low DC Warning Return Voltage @ load < 50% | 22.5Vdc | 45.0Vdc | |
| Low DC Warning Return Voltage @ load ≥ 50% | 22.0Vdc | 44.0Vdc | |
| Low DC Cut-off Voltage @ load < 50% | 20.5Vdc | 41.0Vdc | |
| Low DC Cut-off Voltage @ load ≥ 50% | 20.0Vdc | 40.0Vdc | |
| High DC Recovery Voltage | 32Vdc | 62Vdc | |
| High DC Cut-off Voltage | 33Vdc | 63Vdc | |
| No Load Power Consumption | 30W | 35W | 50W |
7.4 Two Load Output Power
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Full Load | 3600W | 4200W | 6200W |
| Maximum Main Load | 3600W | 4200W | 6200W |
| Second Load Range | 720W~2520W | 840W~2940W | 1240W~4340W |
| Main Load Cut Off Voltage | 22VDC | 44VDC | |
| Main Load Return Voltage | 26VDC | 52VDC |
7.5 Charge Mode Specifications
| Utility Charging Mode | |||
|---|---|---|---|
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
| Charging Algorithm | 3-Step | ||
| AC Charging Current (Max) | 100Amp (@VI/P=230Vac) | ||
| Bulk Charging Flooded Battery | 29.2 | 58.4 | |
| Voltage AGM / Gel Battery | 28.2 | 56.4 | |
| Floating Charging Voltage | 27Vdc | 54Vdc | |
| MPPT Solar Charging Mode | |||
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
| Max. PV Array Power | 6200W | 6500W | |
| Nominal PV Voltage | 240Vdc | 360Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc | ||
| Max. PV Array Open Circuit Voltage | 500Vdc | ||
| Max Charging Current (AC charger plus solar charger) | 120Amp | 120Amp | 120Amp |
7.6 Grid-Tie Operation
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Nominal Output Voltage | 220/230/240 VAC | ||
| Feed-in Grid Voltage Range | 195~253VAC | ||
| Feed-in Grid Frequency Range | 50±1Hz/60±1Hz | ||
| Nominal Output Current | 15.7A | 18.2A | 26.9A |
| Power Factor Range | >0.99 | ||
| Maximum Conversion Efficiency (DC/AC) | 97% | ||
7.7 Approximate Back-up Time Table
The following tables provide approximate backup times based on load and battery capacity. Note that actual backup time depends on battery quality, age, and type, and may vary between manufacturers.
| Model | Load (W) | Backup Time @ 24Vdc 100Ah (min) | Backup Time @ 24Vdc 200Ah (min) |
|---|---|---|---|
| 3.6KW/4.2KW | 300 | 449 | 1100 |
| 600 | 222 | 525 | |
| 900 | 124 | 303 | |
| 1200 | 95 | 227 | |
| 1500 | 68 | 164 | |
| 1800 | 56 | 126 | |
| 2100 | 48 | 108 | |
| 2400 | 35 | 94 | |
| 2700 | 31 | 74 | |
| 3200 | 28 | 67 | |
| 3600 | 25 | 60 | |
| 4200 | 22 | 53 |
| Model | Load (W) | Backup Time @ 48Vdc 100Ah (min) | Backup Time @ 48Vdc 200Ah (min) |
|---|---|---|---|
| 6.2KW | 500 | 613 | 1288 |
| 1000 | 268 | 613 | |
| 1500 | 158 | 402 | |
| 2000 | 111 | 271 | |
| 2500 | 90 | 215 | |
| 3200 | 76 | 182 | |
| 3500 | 65 | 141 | |
| 4000 | 50 | 112 | |
| 4500 | 44 | 100 | |
| 5000 | 40 | 90 | |
| 6200 | 36 | 80 |
8. User Tips
- Prioritizing Solar/Battery: The inverter is often configured as a no-break system by default. To prioritize solar power and battery usage, and only use utility grid power as a last resort, you will need to adjust the settings in the LCD menu (refer to section 4.4 LCD Setting, Program 01: Output source priority).
- Terminal Connections: Some users have noted that the terminals, especially for solar panels, can be soft or difficult to tighten. Exercise care during connection to ensure secure and firm wiring.
- Manual Language: The primary manual is in English. If you require instructions in another language, please check for translated versions or consult online resources.
9. Warranty and Support
For detailed warranty information and further support, please refer to the official user manual PDF available at SUMRY ECO Hybrid Inverter User Manual (PDF). This document contains comprehensive details regarding product guarantees and service procedures.